| Description | Glycogen is a macromolecular polysaccharide composed of glucose and serves as one of the primary storage forms of sugar. It is mainly stored in the liver and muscles as reserve energy, referred to as liver glycogen and muscle glycogen, respectively. Liver glycogen regulates blood glucose Glycogen is a macromolecular polysaccharide composed of glucose and serves as one of the primary storage forms of sugar. It is mainly stored in the liver and muscles as reserve energy, referred to as liver glycogen and muscle glycogen, respectively. Liver glycogen regulates blood glucose concentration; when blood sugar rises, glycogen can be synthesized in the liver, and when blood sugar decreases, liver glycogen is broken down into glucose to supplement blood sugar. Therefore, liver glycogen is crucial for maintaining the relative balance of blood glucose. Muscle glycogen is the storage form of sugar in muscles. During strenuous exercise that consumes large amounts of blood sugar, muscle glycogen cannot be directly broken down into blood sugar but must first decompose to produce lactic acid, which circulates to the liver via the bloodstream and is converted into liver glycogen and glucose through gluconeogenesis. Detection Principle: Glycogen is extracted using a strong alkaline extraction buffer. Under strong acidic conditions, it forms a blue compound with the anthrone chromogen, which has a characteristic absorption peak at 620 nm. Within a certain concentration range, the glycogen content is linearly related to the absorbance at 620 nm. The glycogen content in the sample can be calculated based on the standard curve. Detection Range: 0.003125 - 0.25 mg/mL Sensitivity: 0.003125 mg/mL Applicable Samples: Animal tissues, bacteria, cellsG1501748Component96TStorageG1501748AExtraction Buffer120 mL2-8℃G1501748BChromogen1EA2-8℃. Store in the dark.G1501748CStandard1 mL2-8℃Note: It is recommended to perform preliminary experiments using 2-3 samples expected to have significant differences before formal testing.User-Provided Instruments and Consumables1.Microplate reader or visible spectrophotometer (capable of measuring absorbance at 620 nm)2.Low-temperature centrifuge, Water bath3.96-well plate or micro glass cuvettes, Adjustable pipettes and tips, EP tubes4.Deionized water, Concentrated sulfuric acidExperimental Procedure1. Reagent PreparationReagent NameReagent PreparationPrecautionsExtraction BufferReady-to-use; equilibrate to room temperature before use.Store at 4°C. Corrosive; please take protective measures during handling.ChromogenFirst, dissolve the powder in 7.2 mL of deionized water. Then slowly add 28.8 mL of concentrated sulfuric acid. Mix thoroughly after complete dissolution.Store at 4°C protected from light; valid for one week. Toxic; please take protective measures during handling.StandardStore at 4°C.2. Standard Curve SetupDilute the 1 mg/mL standard with deionized water to prepare standard solutions of 0.25, 0.1, 0.05, 0.025, 0.0125, 0.00625, and 0.003125 mg/mL as shown in the table below.No.Standard VolumeDeionized Water Volume (µL)Concentration (mg/mL)Std.1100µL of 1mg/mL3000.25Std.2160µL of Std.12400.1Std.3200µL of Std.22000.05Std.4200µL of Std.32000.025Std.5200µL of Std.42000.0125Std.6200µL of Std.52000.00625Std.7200µL of Std.62000.003125Note: A standard curve must be prepared for each experiment. Diluted standard solutions are unstable and must be used within 4 hours.3. Sample PreparationNote: Fresh samples are recommended. If not used immediately, samples can be stored at -80°C for up to 1 month.3.1 TissuesWeigh 0.1 g of tissue and place it in a 10 mL test tube. Add 0.75 mL of Extraction Buffer. Boil in a water bath for 20 minutes (stopper the tube tightly to prevent water evaporation). Shake the tube every 5 minutes to mix thoroughly. After the tissue is completely dissolved, remove the tube and let it cool. Dilute to 5 mL with deionized water, mix well. Centrifuge at 8,000 g, 25°C for 10 minutes. Collect the supernatant for detection.3.2 Cells or BacteriaCollect 5 million bacteria or cells into an EP tube. Centrifuge and discard the supernatant. Add 0.75 mL of Extraction Buffer and disrupt the bacteria or cells by ultrasonication (power 200 W, ultrasonicate for 3 s, interval 10 s, repeat 30 times). Transfer to a 10 mL test tube. Boil in a water bath for 20 minutes (stopper the tube tightly to prevent water evaporation). Shake the tube every 5 minutes to mix thoroughly. Remove the tube and let it cool. Dilute to 5 mL with deionized water, mix well. Centrifuge at 8,000 g, 25°C for 10 minutes. Collect the supernatant for detection.Note: For protein concentration determination, Aladdin BCA Protein Quantification Kit (B665595) or Ready-to-Use BCA Protein Quantification Kit (R1491648) are recommended.4. Assay Steps4.1 Instrument Preparation: Preheat the microplate reader or visible spectrophotometer for at least 30 minutes. Set the wavelength to 620 nm. For visible spectrophotometers, zero the instrument with deionized water.4.2 Sample Assay: Add reagents sequentially to EP tubes as follows:ReagentBlank Tube (µL)Standard Tube (µL)Test Tube (µL)Sample0060Standard0600Deionized Water6000Chromogen2402402404.3 Mix well. Incubate in a 95°C water bath for 10 minutes (cap tightly to prevent evaporation). Cool. Transfer 200 µL to a 96-well plate or micro glass cuvette. Measure the absorbance at 620 nm, recorded as A blank, A standard, and A test. Calculate ΔA test = A test - A blank and ΔA standard = A standard - A blank. Note: It is recommended to perform preliminary experiments with 2-3 samples expected to have significant differences before formal testing. If ΔA test is less than 0.001, appropriately increase the sample amount. If ΔA test is greater than 1.5, dilute the sample further with deionized water (multiply the result by the dilution factor) or reduce the amount of sample used for extraction. 5. Result Calculation Note: We provide both derived and simplified calculation formulas, which are equivalent. The simplified formulas in bold are recommended as the final calculation formulas. 5.1 Standard Curve Plotting Plot the standard curve with standard concentration as the y-axis and ΔA standard as the x-axis (using concentration as the y-axis facilitates calculation). Substitute ΔA test into x to calculate y (mg/mL). 5.2 Sample Glycogen Content Calculation (1) Based on sample mass: Glycogen (mg/g) = 1.11 × (y × V sample ) ÷ (W × V sample ÷ V total ) × n = 5.55 × y ÷ W × n (2) Based on sample protein concentration: Glycogen (mg/mg prot) = 1.11 × (y × V sample ) ÷ (V sample × Cpr) × n = 1.11 × y ÷ Cpr × n (3) Based on bacterial or cell count: Glycogen (mg/10⁴) = 1.11 × (y × V sample ) ÷ (Bacterial or Cell Count × V sample ÷ V total ) × n = 5.55 × y ÷ Bacterial or Cell Count × n Parameter Description: 1.11: Constant for converting glucose content measured by this method to glycogen content (i.e., 100 µg glucose color developed with anthrone reagent is equivalent to that of 111 µg glycogen). V sample : Volume of test sample added to the reaction system, 0.06 mL. W: Sample mass, g. V total : Total volume of the sample extract, 5 mL. n: Dilution factor. Cpr: Sample protein concentration, mg/mL. Bacterial or Cell Count: In units of 10⁴ (ten thousands)6. Result PresentationTypical Standard Curve: y = 0.1746x + 0.0027, R² = 0.9961(The following data and curve are for reference only; users must establish their own standard curve based on their experiment.)Precautions1. It is recommended to perform preliminary experiments using 2-3 samples expected to have significant differences before formal testing.2. This product is for scientific research use only and is not intended for clinical diagnosis. For your safety and health, please wear a lab coat and disposable gloves during operation... Read More | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export | Inquire | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export | Product content: G665990Component200 TStorageG665990ABuffer PG100 mLRTG665990BBuffer PS60 mLRTG665990CBuffer PW (concentrate)50 mLRTG665990DBuffer EB30 mLRTG665990ESpin Columns DM with Collection Tubes200 EART Product Introduction:This kit uses a new silicon-based plasma membrane technology and Product content: G665990Component200 TStorageG665990ABuffer PG100 mLRTG665990BBuffer PS60 mLRTG665990CBuffer PW (concentrate)50 mLRTG665990DBuffer EB30 mLRTG665990ESpin Columns DM with Collection Tubes200 EART Product Introduction:This kit uses a new silicon-based plasma membrane technology and reagent formulation. Through the unique centrifugal adsorption column and the DNA washing elution step, 100 bp-10 kb DNA fragments can be recovered and purified from ordinary or low melting point agarose gel. The sol speed is fast and the recovery rate is high. The sol solution contains a pH indicator, which can be used to determine whether the sol recovery has reached the optimal state based on its color. Each adsorption column can adsorb up to 10 µ G DNA, while effectively removing impurities such as primers, enzymes, mineral oil, and agarose. The purified and recovered DNA has high purity and concentration, good integrity, and can be directly used for molecular biology experiments such as sequencing, linking and transformation, labeling, and in vitro transcription.Self prepared reagents: anhydrous ethanol, isopropanol.Preparation and important precautions before the experiment:1.Before the first use, anhydrous ethanol should be added to the Buffer PW according to the instructions on the reagent bottle label.2. Before use, please check the Buffer PG. If crystallization or precipitation occurs, it can be left in a 37 ℃ water bath for 3-5 minutes to restore clarity.3. It is best to use a new electrophoresis buffer during electrophoresis to avoid affecting the electrophoresis and recovery efficiency; The following experiment requires high requirements, please use TAE electrophoresis buffer as much as possible.4.When cutting glue, the UV irradiation time should be as short as possible to avoid damage to DNA.5. The recovery rate is related to the initial amount of DNA and the elution volume. The smaller the initial amount, the smaller the elution volume, and the lower the recovery rate.6. Preheat the water bath to 50 ℃.7. Buffer PG contains a pH indicator. When the pH is ≤ 7.5, the color of the solution is yellow, and DNA can effectively bind to the membrane. When the pH is too high, the color of the solution turns orange red and purple, which needs to be adjusted.8. All centrifugation steps can be performed at room temperature.Operation steps:1. Cut the single purpose DNA strip from the agarose gel (try to cut the excess), put it into a clean centrifuge tube (self prepared), and weigh and calculate the weight of the gel (record the weight of the centrifuge tube in advance).Attention: If the volume of the adhesive block is too large, it can be cut into small pieces.2. Add one time of the volume of Buffer PG (if the gel weighs 100 mg, its volume can be regarded as 100 µ l. And so on.3.50 ℃ water bath and gently invert the centrifuge tube every 2-3 minutes until the sol turns yellow to ensure full dissolution of the gel block. If there are still unsolved glue blocks, you can add some more sol solution or continue to let it stand for a few minutes until the glue blocks are completely dissolved.Note: 1) After the gel is completely dissolved, the gel solution is yellow, and subsequent operations can be carried out; If the glue solution is orange red or purple, 10-30 can be added to the glue solution µ 3 M sodium acetate (pH 5.0), adjust the color of the solution to yellow before proceeding with subsequent operations.2) After the gel block is completely dissolved, it is best to lower the temperature of the gel solution to room temperature before loading the column. The adsorption column has a weaker ability to bind DNA at higher temperatures.4. (Optional step) When the recovered fragment is less than 300 bp, add 1/2 of the gel volume of isopropanol, and mix it upside down (if the gel weighs 100 mg, add 50 µ Isopropanol of L.5. Column balance: Add 200 to the spin columns DM that have been loaded into the collection tube µ Centrifuge at 13000 rpm (~16200 × g) for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.6. Add the solution obtained from steps 3 or 4 to the adsorption column that has been loaded into the collection tube, let it stand at room temperature for 2 minutes, centrifuge at 13000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column in the collection tube.Attention: The volume of the adsorption column is 750 µ l. If the sample volume is greater than 750 µ L can be added in batches.7. Add 450 to the adsorption column µ LBuffer PW (please check if anhydrous ethanol has been added before use), centrifuge at 13000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column in the collection tube.Note: If purified DNA is used for salt sensitive experiments (such as flat end ligation or direct sequencing), it is recommended to add Buffer PW and let it stand for 2-5 minutes before centrifugation.8. Repeat step 7.9.13000 rpm for 1 minute and discard the waste liquid from the collection tube.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).10. Place the adsorption column into a new 1.5 ml centrifuge tube (provided by oneself), and add 50 drops to the middle position of the adsorption membrane in the air µ L Buffer EB, leave at room temperature for 2 minutes. Centrifuge at 13000 rpm for 1 minute and collect DNA solution- Store DNA at 20 ℃.Attention:1) To improve the recovery of DNA, the solution obtained by centrifugation can be re dropped onto the adsorption column, left at room temperature for 2 minutes, and centrifuged at 13000 rpm for 1 minute.2) The elution volume should not be less than 30 µ l. A small volume will affect the recovery efficiency.3) When recovering DNA fragments larger than 10 kb, Buffer EB should be preheated in a 50 ℃ water bath to increase recovery efficiency.Note: This reagent kit is also suitable for the purification and recovery of PCR products. Add an equal volume of Buffer PG to the PCR reaction solution and mix thoroughly (for small fragments with a recovery of less than 150bp, the solution volume can be increased to three times to improve the recovery rate). Follow step 5 above for further operations... Read More |