| Description | Glycogen is a macromolecular polysaccharide composed of glucose and serves as one of the primary storage forms of sugar. It is mainly stored in the liver and muscles as reserve energy, referred to as liver glycogen and muscle glycogen, respectively. Liver glycogen regulates blood glucose Glycogen is a macromolecular polysaccharide composed of glucose and serves as one of the primary storage forms of sugar. It is mainly stored in the liver and muscles as reserve energy, referred to as liver glycogen and muscle glycogen, respectively. Liver glycogen regulates blood glucose concentration; when blood sugar rises, glycogen can be synthesized in the liver, and when blood sugar decreases, liver glycogen is broken down into glucose to supplement blood sugar. Therefore, liver glycogen is crucial for maintaining the relative balance of blood glucose. Muscle glycogen is the storage form of sugar in muscles. During strenuous exercise that consumes large amounts of blood sugar, muscle glycogen cannot be directly broken down into blood sugar but must first decompose to produce lactic acid, which circulates to the liver via the bloodstream and is converted into liver glycogen and glucose through gluconeogenesis. Detection Principle: Glycogen is extracted using a strong alkaline extraction buffer. Under strong acidic conditions, it forms a blue compound with the anthrone chromogen, which has a characteristic absorption peak at 620 nm. Within a certain concentration range, the glycogen content is linearly related to the absorbance at 620 nm. The glycogen content in the sample can be calculated based on the standard curve. Detection Range: 0.003125 - 0.25 mg/mL Sensitivity: 0.003125 mg/mL Applicable Samples: Animal tissues, bacteria, cellsG1501748Component96TStorageG1501748AExtraction Buffer120 mL2-8℃G1501748BChromogen1EA2-8℃. Store in the dark.G1501748CStandard1 mL2-8℃Note: It is recommended to perform preliminary experiments using 2-3 samples expected to have significant differences before formal testing.User-Provided Instruments and Consumables1.Microplate reader or visible spectrophotometer (capable of measuring absorbance at 620 nm)2.Low-temperature centrifuge, Water bath3.96-well plate or micro glass cuvettes, Adjustable pipettes and tips, EP tubes4.Deionized water, Concentrated sulfuric acidExperimental Procedure1. Reagent PreparationReagent NameReagent PreparationPrecautionsExtraction BufferReady-to-use; equilibrate to room temperature before use.Store at 4°C. Corrosive; please take protective measures during handling.ChromogenFirst, dissolve the powder in 7.2 mL of deionized water. Then slowly add 28.8 mL of concentrated sulfuric acid. Mix thoroughly after complete dissolution.Store at 4°C protected from light; valid for one week. Toxic; please take protective measures during handling.StandardStore at 4°C.2. Standard Curve SetupDilute the 1 mg/mL standard with deionized water to prepare standard solutions of 0.25, 0.1, 0.05, 0.025, 0.0125, 0.00625, and 0.003125 mg/mL as shown in the table below.No.Standard VolumeDeionized Water Volume (µL)Concentration (mg/mL)Std.1100µL of 1mg/mL3000.25Std.2160µL of Std.12400.1Std.3200µL of Std.22000.05Std.4200µL of Std.32000.025Std.5200µL of Std.42000.0125Std.6200µL of Std.52000.00625Std.7200µL of Std.62000.003125Note: A standard curve must be prepared for each experiment. Diluted standard solutions are unstable and must be used within 4 hours.3. Sample PreparationNote: Fresh samples are recommended. If not used immediately, samples can be stored at -80°C for up to 1 month.3.1 TissuesWeigh 0.1 g of tissue and place it in a 10 mL test tube. Add 0.75 mL of Extraction Buffer. Boil in a water bath for 20 minutes (stopper the tube tightly to prevent water evaporation). Shake the tube every 5 minutes to mix thoroughly. After the tissue is completely dissolved, remove the tube and let it cool. Dilute to 5 mL with deionized water, mix well. Centrifuge at 8,000 g, 25°C for 10 minutes. Collect the supernatant for detection.3.2 Cells or BacteriaCollect 5 million bacteria or cells into an EP tube. Centrifuge and discard the supernatant. Add 0.75 mL of Extraction Buffer and disrupt the bacteria or cells by ultrasonication (power 200 W, ultrasonicate for 3 s, interval 10 s, repeat 30 times). Transfer to a 10 mL test tube. Boil in a water bath for 20 minutes (stopper the tube tightly to prevent water evaporation). Shake the tube every 5 minutes to mix thoroughly. Remove the tube and let it cool. Dilute to 5 mL with deionized water, mix well. Centrifuge at 8,000 g, 25°C for 10 minutes. Collect the supernatant for detection.Note: For protein concentration determination, Aladdin BCA Protein Quantification Kit (B665595) or Ready-to-Use BCA Protein Quantification Kit (R1491648) are recommended.4. Assay Steps4.1 Instrument Preparation: Preheat the microplate reader or visible spectrophotometer for at least 30 minutes. Set the wavelength to 620 nm. For visible spectrophotometers, zero the instrument with deionized water.4.2 Sample Assay: Add reagents sequentially to EP tubes as follows:ReagentBlank Tube (µL)Standard Tube (µL)Test Tube (µL)Sample0060Standard0600Deionized Water6000Chromogen2402402404.3 Mix well. Incubate in a 95°C water bath for 10 minutes (cap tightly to prevent evaporation). Cool. Transfer 200 µL to a 96-well plate or micro glass cuvette. Measure the absorbance at 620 nm, recorded as A blank, A standard, and A test. Calculate ΔA test = A test - A blank and ΔA standard = A standard - A blank. Note: It is recommended to perform preliminary experiments with 2-3 samples expected to have significant differences before formal testing. If ΔA test is less than 0.001, appropriately increase the sample amount. If ΔA test is greater than 1.5, dilute the sample further with deionized water (multiply the result by the dilution factor) or reduce the amount of sample used for extraction. 5. Result Calculation Note: We provide both derived and simplified calculation formulas, which are equivalent. The simplified formulas in bold are recommended as the final calculation formulas. 5.1 Standard Curve Plotting Plot the standard curve with standard concentration as the y-axis and ΔA standard as the x-axis (using concentration as the y-axis facilitates calculation). Substitute ΔA test into x to calculate y (mg/mL). 5.2 Sample Glycogen Content Calculation (1) Based on sample mass: Glycogen (mg/g) = 1.11 × (y × V sample ) ÷ (W × V sample ÷ V total ) × n = 5.55 × y ÷ W × n (2) Based on sample protein concentration: Glycogen (mg/mg prot) = 1.11 × (y × V sample ) ÷ (V sample × Cpr) × n = 1.11 × y ÷ Cpr × n (3) Based on bacterial or cell count: Glycogen (mg/10⁴) = 1.11 × (y × V sample ) ÷ (Bacterial or Cell Count × V sample ÷ V total ) × n = 5.55 × y ÷ Bacterial or Cell Count × n Parameter Description: 1.11: Constant for converting glucose content measured by this method to glycogen content (i.e., 100 µg glucose color developed with anthrone reagent is equivalent to that of 111 µg glycogen). V sample : Volume of test sample added to the reaction system, 0.06 mL. W: Sample mass, g. V total : Total volume of the sample extract, 5 mL. n: Dilution factor. Cpr: Sample protein concentration, mg/mL. Bacterial or Cell Count: In units of 10⁴ (ten thousands)6. Result PresentationTypical Standard Curve: y = 0.1746x + 0.0027, R² = 0.9961(The following data and curve are for reference only; users must establish their own standard curve based on their experiment.)Precautions1. It is recommended to perform preliminary experiments using 2-3 samples expected to have significant differences before formal testing.2. This product is for scientific research use only and is not intended for clinical diagnosis. For your safety and health, please wear a lab coat and disposable gloves during operation... Read More | DescriptionTakasago (R)-Ru Cymene Kit I comprises of ruthenium-based biphenyl phosphine cymene catalysts containing either BINAP and SEGPHOS®ligands. These highly reactive and selective catalysts are useful in a variety of asymmetric reactions, mainly asymmetric hydrogenation | This reagent kit is based on TRIzon's improved columnar total RNA extraction kit. This product can be extracted from animal groupsExtract total RNA from samples such as textiles, plant materials, various microorganisms, and cultured cells. Firstly, the cracking solution is fully cracked This reagent kit is based on TRIzon's improved columnar total RNA extraction kit. This product can be extracted from animal groupsExtract total RNA from samples such as textiles, plant materials, various microorganisms, and cultured cells. Firstly, the cracking solution is fully cracked andHomogenized samples, in their unique high salt state, RNA specifically binds to silicon matrix membranes, greatly reducingEffectively removing organic solvent contamination while removing protein contamination, resulting in higher purity and quality of RNA. bookThe product can quickly extract total RNA from various cells or tissues, and can process 30-50 mg of tissue or 5 × 10 ⁶ cells each time,Can handle multiple different samples simultaneously. If it is an RNA experiment that is very sensitive to trace amounts of DNA, the residual DNA can be utilizedUsing DNase without RNase for digestion and removal on the column, the extracted RNA can be directly applied to RT-PCR Experiments such as Northern Blot, Dot Blot, and in vitro translation. U665516 Component 50 T Storage U665516A DNase I 1000 U -20℃. Avoid freeze/thaw cycle. U665516B 10×Reaction Buffer 1000 µL -20℃. Avoid freeze/thaw cycle. U665516C TRIzon Reagent 60 mL 2-8℃. Protect from light. U665516D TRIzon PaI™ 10 mL 2-8℃. Protect from light. U665516E Buffer RW1 40 mL RT U665516F Buffer RW2 (concentrate) 11 mL RT U665516G RNase-Free Water 10 mL RT U665516H Spin Columns RM with Collection Tubes 50 sets RT U665516I RNase-Free Centrifuge Tubes (1.5 mL) 50 EA RTPreparation and important precautions before the experiment:1.To prevent RNase pollution, attention should be paid to the following aspects:1) RNase's plastic products and gun heads to avoid cross contamination.2) Prepare the solution using water without RNase.3) Operators should wear disposable masks and gloves, and change gloves frequently during the experiment.2. The sample should avoid repeated freezing and thawing, otherwise it will affect the yield and quality of RNA extraction.3. If TRIzon Reagent is found to have precipitates before use, it can be dissolved in a water bath at 56 ℃ for a few minutes.Before the first use, anhydrous ethanol should be added to Buffer RW2 according to the instructions on the reagent bottle label.5. All centrifugation steps should be carried out at room temperature unless otherwise specified, and all operation steps should be carried out quickly.Usage:1. Sample processing1a. Organization: 30-50 mg of tissue is thoroughly ground in liquid nitrogen and 1 mL of TRIzon Reagent is added, or 1 mL of TRIzon Reagent is added to the tissue sample and homogenized. Attention: The sample volume should not exceed 10% of the volume of TRIzon Reagent.2a. Single layer cell culture: Remove the culture medium and add an appropriate amount every 10 cm ² Add 1 mL of TRIzon Reagent.3a. Cell suspension: Collect cells by centrifugation. Add 1 mL of TRIzon Reagent to every 5 × 10 µ m cell.2. After adding TRIzon Reagent, repeatedly blow a few times to fully crack the sample. Leave at room temperature for 5 minutes to completely separate the protein nucleic acid complex.3. Add 200 to every 1 mL of TRIzon Reagent µ LTRIzon PaI ™, Cover the tube tightly, vigorously shake for 15 seconds, and let it sit at room temperature for 2 minutes.4. Centrifuge at 4 ℃ 12000 rpm (~13400 × g) for 10 minutes. At this time, the sample is divided into three layers: the red organic phase, the middle layer, and the upper colorless aqueous phase. RNA is mainly in the upper aqueous phase. Move the upper aqueous phase to a new RNase Free centrifuge tube (provided).5. Add an equal volume of 70% ethanol (prepared without RNase water) to the obtained aqueous solution, invert and mix well.6. Add all the solutions obtained in the previous step to the spin columns RM that have been loaded into the collection tube. If the solution cannot be added at once, it can be transferred in multiple batches. Centrifuge at 12000 rpm for 20 seconds, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.7. Add 350 to the adsorption column µ L Buffer RW1, centrifuge at 12000 rpm for 20 seconds, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.8. Preparation of DNase I mixture: Take 52 µ LRNase Free Water, add 8 to it µ L 10 x Reaction Buffer and 20 µ L DNase I (1 U/ µ L) Mix well and prepare to a final volume of 80 µ The reaction solution of L.9. Directly add 80 µ L DNase I mixture to the adsorption column and incubate at 20-30 ℃ for 15 minutes.10. Add 350 to the adsorption column µ L Buffer RW1, centrifuge at 12000 rpm for 1 minute, discard the waste liquid, and place the adsorption column back into the recovery manifold.11. Add 500 to the adsorption column µ L Buffer RW2 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 20 seconds, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.12. Repeat step 11.Centrifuge at 12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes and thoroughly air dry. Attention: The purpose of this step is to remove residual ethanol from the adsorption column, which will affect subsequent enzymatic reactions (enzyme digestion,. )PCR, etc.14. Place the adsorption column in a new RNase free centrifuge tube and add 30-50 to the middle of the adsorption column µ Place RNase Free Water at room temperature for 1 minute, centrifuge at 12000 rpm for 1 minute, collect RNA solution, and store RNA at -70 ℃ to prevent degradation.Attention:1) The volume of RNase Free Water should not be less than 30 µ L. Small volume affects the recovery rate.2) If you want to increase RNA production, you can use 30-50 µ Repeat step 14 for the new RNase Free Water.3) If you want to increase the RNA concentration, you can add the obtained solution back to the adsorption column and repeat step 14... Read More | Product contentU665751Component100 TStorageU665751A2×UltraSYBR One Step Buffer1.4 mL-20℃. Avoid freeze/ Thaw cycle. Protect from light.U665751BUltraSYBR One Step EnzymeMix50 µL-20℃. Avoid freeze/ Thaw cycle. Protect from light.U665751C50×High ROX50 µL-20℃. AvoidProduct contentU665751Component100 TStorageU665751A2×UltraSYBR One Step Buffer1.4 mL-20℃. Avoid freeze/ Thaw cycle. Protect from light.U665751BUltraSYBR One Step EnzymeMix50 µL-20℃. Avoid freeze/ Thaw cycle. Protect from light.U665751C50×High ROX50 µL-20℃. Avoid freeze/ Thaw cycle. Protect from light.U665751DRNase-Free Water1.5 mL-20℃. Avoid freeze/ Thaw cycle. Product Introduction This product is a specialized kit for one-step Real-Time RT-qPCR. The SYBR Green I fluorescent dye contained can bind to all double-stranded DNA, allowing this product to be used for the detection of many different target sequences without the need to synthesize specific labeling probes. Real Time RT-qPCR reaction using this product, reverse transcription and quantitative PCR are carried out in the same reaction system, there is no need to add reagents during the reaction, no need to open the cap of the tube, avoiding contamination while improving the efficiency of the experiment. The new high-efficiency reverse transcriptase RNase H is activity-deficient, which reduces the degradation of RNA in the reverse transcription reaction. The enzyme has high reverse transcription efficiency and can perform a good reverse transcription reaction on a small amount of RNA template. It has high affinity to RNA and can read through RNA templates with high GC content and complex secondary structure. New efficient hot start enzyme, the enzyme activity is closed at room temperature, thus effectively avoiding non-specific amplification caused by non-specific binding of primers and templates or primer dimerization at room temperature, which greatly improves the accuracy of fluorescence quantitative PCR reaction. The included buffer system maximizes the efficacy of both enzymes at the same time and improves efficiency. This product has high sensitivity, high specificity, wide linear range, and more accurate quantification of target genes.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used with Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument. Instruments that do not require ROX calibration (U665567) Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96 and others. Instruments that require High ROX calibration (U665751) ABI Prism 7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, and others.matters needing attention1. Before using the reagents in this kit, please mix them gently by turning them up and down to avoid foaming as much as possible, and use them after brief centrifugation.2. This product uses RNA as the template for one-step RT-PCR experiment, RNase contamination should be avoided during operation, it is recommended to operate RNA in a special area, use special instruments and consumables, the operator with a mask and disposable gloves and often change the gloves, the experiment-related consumables should be processed with 0.1% DEPC (diethyl ether of pyrocarbonate) aqueous solution at 37℃ for 12 hours and autoclaved for 30 minutes before use. Sterilize for 30 minutes before use.3. UltraSYBR One Step RT-qPCR Buffer contains SYBR Green I fluorescent dye. Avoid bright light when storing this product or preparing PCR reaction solutions.4. Repeated freezing and thawing of each reagent in this kit should be avoided; repeated freezing and thawing may degrade the product performance. This product can be stored for a long time at -20℃, protected from light. If frequent use is required in the short term, it can be stored at 2-8℃.5. This kit must use specific primers, the choice of primers can be selected according to specific experiments, the good or bad primer design directly affects the results of RT-PCR reaction, the design of primers need to consider the GC content, primer length, primer position, the secondary structure of the PCR product and other factors, it is recommended to use a professional primer design software for design.6. This product cannot be used for fluorescent quantitative PCR by the probe method.Usage1. Dissolve RNA template, primers, 2× UltraSYBR One Step Buffer, UltraSYBR One Step EnzymeMix and RNase-Free Water and set aside on ice.2. PCR reaction system:Reagents25 µl Reaction systemFinal concentration2×UltraSYBR One Step Buffer12.5 µl1×Forward Primer,10 µM0.5 µl0.2 µM¹⁾Reverse Primer,10 µM0.5 µl0.2 µM¹⁾UltraSYBR One Step EnzymeMix0.5 µl RNA TemplateX µl10 pg – 100 ng50×Low ROX or High ROX(optional)2)0.5 µl1×RNase-Free Waterup to 25 µlNote: 1) Usually, the primer concentration of 0.2µM can get better results, and the final concentration of 0.1-0.5µM can be used as a reference for setting the range. If the amplification efficiency is not high, the concentration of primer can be increased; when non-specific reaction occurs, the concentration of primer can be decreased, thus optimizing the reaction system.(2) The excitation optical system varies from instrument to instrument, choose to add 50×Low ROX or 50×High ROX according to the instrument using fluorescence quantification.3. Vortex and shake to mix, centrifuge briefly, and collect the solution at the bottom of the tube.4. RT-qPCR reaction conditions (fluorescence quantitative PCR is a two-step method), this program is based on the ABI 7500 fluorescence quantitative PCR instrument as an exampleNote: 1) It is recommended to use two-step PCR reaction program, if you improve the reaction specificity, you can increase the annealing temperature to 60-64 ℃ as a reference for the setting range; if you do not get good experimental results due to the use of primers with lower Tm values, etc., you can try to carry out three-step PCR amplification.(2) For melting curve analysis, please set up the program recommended by the fluorescence quantitative PCR instrument used, and this program is set up with the ABI 7500 fluorescence quantitative PCR instrument as a reference.RT-qPCR reaction conditions (fluorescence quantitative PCR was a three-step method):Note: 1) For three-step PCR amplification, please use the range of 56℃-64℃ as the setting reference for the annealing temperature.(2) For melting curve analysis, please set up the program recommended by the fluorescence quantitative PCR instrument you are using, this program is ABI750 fluorescent quantitative PCR instrument as a reference setting... Read More | Product contentComponentY665957-1mlY665957-5ml2×GoldStar Probe Mixture1 ml5×1 mlProbe Primer Mix300 µl5×300 µlHuman DNA Standard(100 ng/µl)100 µl5×100 µl50×High ROX40 µl200 µlProduct IntroductionThis product is a real-time Product contentComponentY665957-1mlY665957-5ml2×GoldStar Probe Mixture1 ml5×1 mlProbe Primer Mix300 µl5×300 µlHuman DNA Standard(100 ng/µl)100 µl5×100 µl50×High ROX40 µl200 µlProduct IntroductionThis product is a real-time fluorescence quantitative PCR kit for detecting the concentration of human male Y chromosome, including carefully optimized PCR reaction solution, primer mixture and standards, especially suitable for the quantitative detection of precious and micro DNA samples. The kit adopts a new efficient and fast hot-start amplification enzyme GoldStar Taq DNA Polymerase, which effectively avoids non-specific amplification caused by non-specific binding of primers and templates or primer dimerization at room temperature. This product realizes accurate quantification of Y chromosome and can be applied in various fields such as genetic mapping, species polymorphism research, disease gene localization, paternity testing and forensic analysis.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used in Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument.Instruments that do not require ROX calibration: Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96, etc.Instruments requiring Low ROX calibration: ABI Prism7500/7500 Fast, QuantStudio®3 System, QuantStudio®5 System, QuantStudio®6 Flex System, QuantStudio®7 Flex System, ViiA 7 System, Stratagene Mx3000/Mx3005P, Corbett Rotor Gene 3000, and others.Instruments requiring High ROX calibration: ABI Prism7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, etc.Note: High Rox and Low Rox are formulated as described in Method of Use 3.Scope of applicationThis product is suitable for quantitative testing of male Y chromosome DNA in scientific research, clinical, forensic medicine and paternity testing.Usage1. Amplification template preparationThe library samples to be detected were diluted with TE (10 mM Tris-Cl, pH 8.0, 1 mM EDTA), and the concentration after dilution was as close as possible to the range of 0.05-10 ng/µL. 4°C on ice was set aside.2. Standard dilution: according to the following table, firstly dilute Human DNA Standard (100ng/uL) with TE to make 5 standards of different concentrations according to the table below. 10ng/µL of DNA Standard 1 (Std.1) can be stored stably at -20℃ for 1 month; Std2-5 can only be used on the same day, and should be placed at 4℃ or on ice when not in use for the time being after preparation. When Std2-5 are not used temporarily after preparation, they should be stored at 4℃ or on ice.Standard sampleCorresponding concentration(ng/µl)Minimum Dilution Volume (Unit:µl)Std.11010 [100 ng/µl DNA Standard]+ 90 TEStd.22.520 [Std. 1] +60 TEStd.30.62520 [Std. 2] +60 TEStd.40.1562520 [Std. 3] +60 TEStd.50.039062520 [Std. 4] +60 TE3. qPCR reaction system preparationBefore preparation, the cryopreserved reagents to be used were completely melted and mixed by inverting several times, then centrifuged briefly and prepared. Standards and templates were diluted as described above and prepared.The base reaction system for 20 µL was as follows:Reagent20 µl Reaction system2×GoldStar Probe Mixture10 µlProbe Primer Mix3 µlTemplate4 µlddH₂O3 µlNote: High ROX model: add 1 µL of 50×High ROX per 50 µL of reaction system; Low ROX model: add 1 µL of 50×High ROX per 500 µL of reaction system.A sufficient amount of reaction system mixture was prepared according to the need, and after the reaction system was prepared and mixed thoroughly, it was added to the reaction wells in a volume of 16 µl per well. Then add the prepared standards and diluted samples into the corresponding reaction wells, the amount of addition is 4µL/well. TE was added to the blank control tube, and the same amount was added at 4 µL/well.It is recommended to use 20 µL for the reaction, if you need to perform a smaller system reaction, reduce the system components in equal proportion.4. qPCR reaction programThe PCR mix of this kit contains a FAM fluorescent probe for the target gene and a VIC fluorescent probe with internal reference to Internal PCR Control (IPC). qPCR program with dual fluorescence of hydrolyzed probes needs to be selected for the assay. Please follow the instructions of the instrument used to set up the qPCR program, and the PCR temperature conditions are as follows:1. Standard curve productionThe standard curve was plotted with reference to the Excel sheet for data processing. The correlation coefficient R2 of the standard curve should be not less than 0.98, and the slope should be located between -3.1 and -3.6 when the Ct value is used as the longitudinal coordinate. If the parameters of the standard curve are unreasonable, it is recommended to repeat the experiment.DNA Standard NameDNA Standard Concentration(ng/µL)DNA Standard 110DNA Standard 22.5DNA Standard 30.625DNA Standard 40.15625DNA Standard 50.03906252. Analysis of results and calculation of concentrationsThe Ct difference between experimental replicate wells for FAM signaling of the target gene should be no more than 0.3, otherwise invalid data need to be deleted or the experiment needs to be repeated, do not use Ct outside the valid Ct range of the standard curve to calculate the concentration of the sample.For specific calculations, please refer to the data processing Excel for this product.If the FAM signal is abnormal, the VIC signal of the internal reference Internal PCR Control (IPC) needs to be analyzed to confirm whether the PCR reaction process is abnormal. If the Ct value of the sample null VIC is significantly larger than that of the standard or blank control wells, it means that the sample inhibits the PCR reaction.matters needing attention1. Before testing, these instructions should be read in detail. It should be operated by personnel with professional experience or qualified by training.2. For use, please mix gently by turning up and down, avoid foaming as much as possible, and use it after centrifugation for a short period of time.3. Avoid repeated freezing and thawing of the product, repeated freezing and thawing may degrade the performance of the product.4. When preparing the reaction solution, please use new or non-contaminated tips and centrifuge tubes to prevent contamination as much as possible... Read More |