| Description | Glycogen is a macromolecular polysaccharide composed of glucose and serves as one of the primary storage forms of sugar. It is mainly stored in the liver and muscles as reserve energy, referred to as liver glycogen and muscle glycogen, respectively. Liver glycogen regulates blood glucose Glycogen is a macromolecular polysaccharide composed of glucose and serves as one of the primary storage forms of sugar. It is mainly stored in the liver and muscles as reserve energy, referred to as liver glycogen and muscle glycogen, respectively. Liver glycogen regulates blood glucose concentration; when blood sugar rises, glycogen can be synthesized in the liver, and when blood sugar decreases, liver glycogen is broken down into glucose to supplement blood sugar. Therefore, liver glycogen is crucial for maintaining the relative balance of blood glucose. Muscle glycogen is the storage form of sugar in muscles. During strenuous exercise that consumes large amounts of blood sugar, muscle glycogen cannot be directly broken down into blood sugar but must first decompose to produce lactic acid, which circulates to the liver via the bloodstream and is converted into liver glycogen and glucose through gluconeogenesis. Detection Principle: Glycogen is extracted using a strong alkaline extraction buffer. Under strong acidic conditions, it forms a blue compound with the anthrone chromogen, which has a characteristic absorption peak at 620 nm. Within a certain concentration range, the glycogen content is linearly related to the absorbance at 620 nm. The glycogen content in the sample can be calculated based on the standard curve. Detection Range: 0.003125 - 0.25 mg/mL Sensitivity: 0.003125 mg/mL Applicable Samples: Animal tissues, bacteria, cellsG1501748Component96TStorageG1501748AExtraction Buffer120 mL2-8℃G1501748BChromogen1EA2-8℃. Store in the dark.G1501748CStandard1 mL2-8℃Note: It is recommended to perform preliminary experiments using 2-3 samples expected to have significant differences before formal testing.User-Provided Instruments and Consumables1.Microplate reader or visible spectrophotometer (capable of measuring absorbance at 620 nm)2.Low-temperature centrifuge, Water bath3.96-well plate or micro glass cuvettes, Adjustable pipettes and tips, EP tubes4.Deionized water, Concentrated sulfuric acidExperimental Procedure1. Reagent PreparationReagent NameReagent PreparationPrecautionsExtraction BufferReady-to-use; equilibrate to room temperature before use.Store at 4°C. Corrosive; please take protective measures during handling.ChromogenFirst, dissolve the powder in 7.2 mL of deionized water. Then slowly add 28.8 mL of concentrated sulfuric acid. Mix thoroughly after complete dissolution.Store at 4°C protected from light; valid for one week. Toxic; please take protective measures during handling.StandardStore at 4°C.2. Standard Curve SetupDilute the 1 mg/mL standard with deionized water to prepare standard solutions of 0.25, 0.1, 0.05, 0.025, 0.0125, 0.00625, and 0.003125 mg/mL as shown in the table below.No.Standard VolumeDeionized Water Volume (µL)Concentration (mg/mL)Std.1100µL of 1mg/mL3000.25Std.2160µL of Std.12400.1Std.3200µL of Std.22000.05Std.4200µL of Std.32000.025Std.5200µL of Std.42000.0125Std.6200µL of Std.52000.00625Std.7200µL of Std.62000.003125Note: A standard curve must be prepared for each experiment. Diluted standard solutions are unstable and must be used within 4 hours.3. Sample PreparationNote: Fresh samples are recommended. If not used immediately, samples can be stored at -80°C for up to 1 month.3.1 TissuesWeigh 0.1 g of tissue and place it in a 10 mL test tube. Add 0.75 mL of Extraction Buffer. Boil in a water bath for 20 minutes (stopper the tube tightly to prevent water evaporation). Shake the tube every 5 minutes to mix thoroughly. After the tissue is completely dissolved, remove the tube and let it cool. Dilute to 5 mL with deionized water, mix well. Centrifuge at 8,000 g, 25°C for 10 minutes. Collect the supernatant for detection.3.2 Cells or BacteriaCollect 5 million bacteria or cells into an EP tube. Centrifuge and discard the supernatant. Add 0.75 mL of Extraction Buffer and disrupt the bacteria or cells by ultrasonication (power 200 W, ultrasonicate for 3 s, interval 10 s, repeat 30 times). Transfer to a 10 mL test tube. Boil in a water bath for 20 minutes (stopper the tube tightly to prevent water evaporation). Shake the tube every 5 minutes to mix thoroughly. Remove the tube and let it cool. Dilute to 5 mL with deionized water, mix well. Centrifuge at 8,000 g, 25°C for 10 minutes. Collect the supernatant for detection.Note: For protein concentration determination, Aladdin BCA Protein Quantification Kit (B665595) or Ready-to-Use BCA Protein Quantification Kit (R1491648) are recommended.4. Assay Steps4.1 Instrument Preparation: Preheat the microplate reader or visible spectrophotometer for at least 30 minutes. Set the wavelength to 620 nm. For visible spectrophotometers, zero the instrument with deionized water.4.2 Sample Assay: Add reagents sequentially to EP tubes as follows:ReagentBlank Tube (µL)Standard Tube (µL)Test Tube (µL)Sample0060Standard0600Deionized Water6000Chromogen2402402404.3 Mix well. Incubate in a 95°C water bath for 10 minutes (cap tightly to prevent evaporation). Cool. Transfer 200 µL to a 96-well plate or micro glass cuvette. Measure the absorbance at 620 nm, recorded as A blank, A standard, and A test. Calculate ΔA test = A test - A blank and ΔA standard = A standard - A blank. Note: It is recommended to perform preliminary experiments with 2-3 samples expected to have significant differences before formal testing. If ΔA test is less than 0.001, appropriately increase the sample amount. If ΔA test is greater than 1.5, dilute the sample further with deionized water (multiply the result by the dilution factor) or reduce the amount of sample used for extraction. 5. Result Calculation Note: We provide both derived and simplified calculation formulas, which are equivalent. The simplified formulas in bold are recommended as the final calculation formulas. 5.1 Standard Curve Plotting Plot the standard curve with standard concentration as the y-axis and ΔA standard as the x-axis (using concentration as the y-axis facilitates calculation). Substitute ΔA test into x to calculate y (mg/mL). 5.2 Sample Glycogen Content Calculation (1) Based on sample mass: Glycogen (mg/g) = 1.11 × (y × V sample ) ÷ (W × V sample ÷ V total ) × n = 5.55 × y ÷ W × n (2) Based on sample protein concentration: Glycogen (mg/mg prot) = 1.11 × (y × V sample ) ÷ (V sample × Cpr) × n = 1.11 × y ÷ Cpr × n (3) Based on bacterial or cell count: Glycogen (mg/10⁴) = 1.11 × (y × V sample ) ÷ (Bacterial or Cell Count × V sample ÷ V total ) × n = 5.55 × y ÷ Bacterial or Cell Count × n Parameter Description: 1.11: Constant for converting glucose content measured by this method to glycogen content (i.e., 100 µg glucose color developed with anthrone reagent is equivalent to that of 111 µg glycogen). V sample : Volume of test sample added to the reaction system, 0.06 mL. W: Sample mass, g. V total : Total volume of the sample extract, 5 mL. n: Dilution factor. Cpr: Sample protein concentration, mg/mL. Bacterial or Cell Count: In units of 10⁴ (ten thousands)6. Result PresentationTypical Standard Curve: y = 0.1746x + 0.0027, R² = 0.9961(The following data and curve are for reference only; users must establish their own standard curve based on their experiment.)Precautions1. It is recommended to perform preliminary experiments using 2-3 samples expected to have significant differences before formal testing.2. This product is for scientific research use only and is not intended for clinical diagnosis. For your safety and health, please wear a lab coat and disposable gloves during operation... Read More | Product Descriptionalpha-L-fucoside fucohydrolase, alpha-L-fucosidase, alpha-(1-3,4) fucosidaseAlpha (1-3,4) Fucosidase The enzyme is very efficient and recognises α1-3,4 fucosylated glycans (e.g. Lewis X/A epitopes, including their sialylated counterparts) and hydrolyses terminal α1-3 andProduct Descriptionalpha-L-fucoside fucohydrolase, alpha-L-fucosidase, alpha-(1-3,4) fucosidaseAlpha (1-3,4) Fucosidase The enzyme is very efficient and recognises α1-3,4 fucosylated glycans (e.g. Lewis X/A epitopes, including their sialylated counterparts) and hydrolyses terminal α1-3 and α1-4 fucosyl linkages in these substrates without the need to remove sialic acid moieties.For removing core fucose linked α-(1-6) to the core GlcNAc of a GlcNAc-GlcNAc disaccharide structure we recommend our Alpha-(1-6) Fucosidase.• Non-sialidase dependant hydrolysis of antennary fucose moieties• Effective on both glycopeptides and free glycans• Highly specific (α1-3,4 fucosylated glycans)• Kit includes enzyme plus reaction buffer.• Sufficient for up to 50 samplesα(1-3,4) Fucosidase is useful for:nbsp;nbsp;Fucose linkage determinationnbsp;nbsp;Deglycosylating glycoproteins with Lewis structuresContentsAlpha-(1-3,4)-Fucosidase – 200 mM citrate buffer pH 6 containing 250 mM NaCl5x Reaction Buffer – 250 mM sodium phosphate pH 6... Read More | Alanine Aminotransferase (ALT), also known as serum glutamic-pyruvic transaminase (SGPT), is a pyridoxal-phosphate-dependent enzyme that catalyzes the reversible transfer of an amino group from alanine to α-ketoglutarate, generating pyruvate and glutamate. ALT is found primarily in liver and Alanine Aminotransferase (ALT), also known as serum glutamic-pyruvic transaminase (SGPT), is a pyridoxal-phosphate-dependent enzyme that catalyzes the reversible transfer of an amino group from alanine to α-ketoglutarate, generating pyruvate and glutamate. ALT is found primarily in liver and serum, but occurs in other tissues as well. Hepatocellular injury often results in an increase of serum ALT levels and serum ALT levels can be used as a marker for liver injury.ALT Activity Assay kit has been used to determine the activity of alanine aminotransferase (ALT) in serum samples... Read More | This product is a cDNA first strand synthesis kit specially prepared for the first step experiment of two-step RT-PCR. This product contains all the reagents required for reverse transcription from RNA templates to cDNA first strand, including HiFi MMLV reverse transcriptase, reaction buffer, This product is a cDNA first strand synthesis kit specially prepared for the first step experiment of two-step RT-PCR. This product contains all the reagents required for reverse transcription from RNA templates to cDNA first strand, including HiFi MMLV reverse transcriptase, reaction buffer, primers, dNTP, etc. The mutated HiFi MMLV reverse transcriptase RNase H activity is deficient, reducing RNA degradation in reverse transcription reactions and making it easier to obtain full-length cDNA. HiFi MMLV reverse transcriptase has strong thermal stability and can yield high yields of cDNA, making it simple and convenient to use. This system has high compatibility with subsequent PCR and quantitative PCR experiments, and is suitable for various DNA polymerase reactions. H665693 Component 100 T Storage H665693A HiFi-MMLV, 200 U/µL 100 µL -20℃. Avoid freeze/thaw cycle. H665693B 5×RT Buffer 500 µL -20℃. Avoid freeze/thaw cycle. H665693C Primer Mix 240 µL -20℃. Avoid freeze/thaw cycle. H665693D dNTP Mix, 2.5 mM Each 500 µL -20℃. Avoid freeze/thaw cycle. H665693E DTT, 0.1 M 240 µL -20℃. Avoid freeze/thaw cycle. H665693F RNase-Free Water 1 mL -20℃. Avoid freeze/thaw cycle. Product features:·RNase H -: Mutated HiFi MMLv reverse transcriptase with reduced RNase H activity, making it easier to obtain full-length cDNA.·Easy to use: The reagent kit contains all the reagents required for reverse transcription, except for RNA templates.Notes:1. During the operation process, RNase contamination should be avoided to prevent RNA degradation or cross contamination during experiments. It is recommended to perform RNA operations in specialized areas, use specialized instruments and consumables, and have operators wear masks and disposable gloves, and frequently change gloves.2. Disposable plastic containers should be used as much as possible for experiments. If glass containers are used, they should be treated with a 0.1% DEPC (diethyl pyrocarbonate) aqueous solution at 37 ℃ for 12 hours, and sterilized under high pressure at 120 ℃ for 30 minutes before use. Alternatively, glass containers should be sterilized under dry heat at 180 ℃ for 60 minutes before use. The sterile water used in the experiment should be treated with 0.1% DEPC and then subjected to high-pressure sterilization.3. All reagents in this reagent kit should be gently mixed upside down before use, avoiding foaming as much as possible, and used after brief centrifugation. The enzymes involved should be returned to -20 ℃ as soon as possible after use to avoid repeated freeze-thaw cycles.If the initial amount of RNA is less than 50 ng, it is recommended to add RNA enzyme inhibitors (RNAsin). This kit is not provided.Usage:Attention: 10 ng-5 µ G Total RNA can establish 20 µ Reaction system, if the total RNA content is greater than 5 µ g. Please expand the reaction system proportionallyi Steps for reverse transcription:1. Dissolve RNA templates, primers, dNTP Mix, DTT, RT Buffer, HiFi MMLV, and RNase Free Water and place on ice for later use.2. Prepare a reaction system according to the following table, with a total volume of 20 µ L. Reagent 20 µlReaction system Final concentration dNTP Mix,2.5 mM Each 4 µl 500 µM Each Primer Mix 2 µl / RNA Template X µl 1 ng-5 µg 5×RT Buffer 4 µl 1× DTT,0.1 M 2 µl 10 mM HiFi-MMLV,200 U/µl 1 µl / RNase-Free Water up to 20 µl / Attention:1) If the initial amount of RNA is less than 50 ng, it is recommended to add RNA enzyme inhibitors (RNAsin). This kit is not provided.2) Primer Mix is formulated from Oligo (dT) and Random Primer3. Vortex shake and mix well, briefly centrifuge to collect the solution on the pipe wall to the bottom of the pipe. 4. Incubate at 42 ℃ for 30-50 minutes and 85 ℃ for 5 minutes. After the reaction is complete, centrifuge briefly and cool on ice.5. Reverse transcripts can be directly used for PCR reactions and fluorescence quantitative PCR reactions, or stored at -20 ℃ for a long time.ii If the reverse transcription efficiency is low, or the RNA template secondary structure is complex and the GC content is high, the following steps are recommended:1. Dissolve RNA templates, primers, dNTP Mix, DTT, RT Buffer, HiFi MMLV, and RNase Free Water and place on ice for later use.2. Prepare the reaction system according to the following table, with a total volume of 13 µ L. Reagent 20 µlReaction system Final concentration dNTP Mix,2.5 mM Each 4 µl 500 µM Each Primer Mix 2 µl / RNA Template X µl 1 ng-5 µg RNase-Free Water up to 13 µl / 3. Incubate at 70 ℃ for 10 minutes and quickly ice bath for 2 minutes.4. Centrifuge briefly to collect the solution on the tube wall to the bottom of the tube.5. Continue to add the following reagents to the above reaction solution: Reagent 20 µlReaction system Final concentration 5×RT Buffer 4 µl 1× DTT,0.1 M 2 µl 10 mM HiFi-MMLV,200 U/µl 1 µl / Attention:1) If the initial amount of RNA is less than 50 ng, it is recommended to add RNA enzyme inhibitors (RNAsin). This kit is not provided.2) Primer Mix is formulated from Oligo (dT) and Random primer.6. Gently blow and mix well, incubate at 42 ℃ for 50 minutes, and incubate at 85 ℃ for 5 minutes.7. After the reaction is complete, centrifuge briefly and cool on ice.8. Reverse transcripts can be directly used for PCR reactions and fluorescence quantitative PCR reactions, or stored at -20 ℃ for a long time... Read More | Products content Products IntroductionThis kit is a dedicated sample preparation solution for microbiome analysis and is suitable for the purification and enrichment of genomic DNA of pathogenic microorganisms such as bacteria and fungi from mixed samples such as swabs, blood, sputum, alveolar Products content Products IntroductionThis kit is a dedicated sample preparation solution for microbiome analysis and is suitable for the purification and enrichment of genomic DNA of pathogenic microorganisms such as bacteria and fungi from mixed samples such as swabs, blood, sputum, alveolar lavage, etc. During the purification process, differential lysis of the host cells and subsequent enzymatic digestion can effectively remove most of the host DNA while providing a comprehensive coverage of the bacterial and fungal DNA loci to a higher level. By differential lysis of host cells and subsequent enzymatic digestion, this kit can effectively remove most of the host DNA while maximizing the full coverage of bacterial, fungal and other pathogenic microbial DNA sites, thus obtaining microbiome DNA enrichment products with a higher coverage. Microbial DNA purified with this kit is suitable for a variety of downstream applications, including whole genome sequencing analysis, 16S rDNA-based high sensitivity microbiome analysis, and macrogenomic birdshot sequencing analysis. Self-contained reagents and consumablesSterile pipette tips with aerosol barrier to prevent cross-contamination anhydrous ethanol Microcentrifuge tubes (2 ml/1.5 ml) PBS buffer (required for some samples only)Pre-experiment Preparation and Important Notes1. Add 1.25 ml Proteinase K Storage Buffer to Proteinase K and store at -20℃. Do not leave the prepared Proteinase K (20 mg/ml) at room temperature for a long time, and avoid repeated freezing and thawing to avoid affecting its activity.2. Dissolve Lysozyme (100 mg) in 10 ml Enzymatic Lysis Buffer to a final concentration of 10 mg/ml, dispense into sterile tubes and store at -20℃. Do not leave the prepared Lysozyme (10 mg/ml) at room temperature for a long time and avoid repeated freezing and thawing to avoid affecting its activity.3. Thaw Buffer GB1 and Buffer GB2 at room temperature or 2-8°C before use and mix thoroughly. Thawed Buffer GB1 and Buffer GB2 can be left at 2-8°C for 1-2 weeks without affecting their activity, and should be stored at -20°C for long term storage. To ensure optimal performance, do not freeze or thaw more than three times. If less than one bottle of Buffer GB1 and Buffer GB2 is required for a single extraction, ensure that it is used under sterile conditions such as an ultra-clean bench and avoid microbial contamination and growth in the remaining buffer.4. Before first use, anhydrous ethanol should be added to Buffer GW1 and Buffer GW2 according to the instructions on the vial label and labeled.5. Check Buffer GL for crystallization or precipitation before use, and if crystallization or precipitation occurs, redissolve Buffer GL in a 56°C water bath.6. If the downstream experiments are sensitive to RNA contamination, 4 µl of DNase-Free RNase A (100 mg/ml) can be added before adding Buffer GL. RNase A is not provided in the kit, but can be ordered separately from CW0601S.7. This kit is designed for the isolation of DNA from intact microbial cells. To ensure optimal recovery of microbial DNA, samples should be fresh. If storage or transportation is required, this should preferably be done at 2-8°C and not frozen or thawed, as freezing and thawing can damage the integrity of the microbial cells and therefore result in the loss of exposed microbial DNA during host DNA removal.8. To avoid false results due to contamination, keep the work area clean, wear protective clothing, and set up controls for quality control. Use appropriate measures to handle sample materials to minimize the risk of cross-contamination. During the extraction process, use DNA-free pipette tips and consumables, and cap reagents immediately after use to prevent contamination. procedure1. Sample pre-treatment: 1a: For swab samples, swirl the swab portion of the swab in 0.5 ml PBS for at least 20 s. Squeeze the swab several times against the wall of the tube before removing it so that as much of the bacterial fluid as possible can be squeezed out of the swab to minimize sample loss. 1b: For viscous samples, e.g. sputum, take ~500 µl of sample, add 1.5 times the volume (~750 µl) of Buffer GB1 and incubate at 37°C, 600 rpm for 15-30 min until the sample is completely liquefied.Note: The sample volume can be increased or decreased appropriately and the amount of Buffer GB1 added adjusted accordingly.1c: For alveolar lavage fluid containing a small amount of viscous sputum, centrifuge as much of the alveolar lavage fluid as possible, carefully remove the supernatant, and retain the lower viscous fraction (containing sputum, cells, and organisms), add 1.5 times the volume of Buffer GB1, and incubate for 15-30 min at 37°C, 600 rpm until the sample is completely liquefied.1d: For non-viscous body fluid samples such as blood and cerebrospinal fluid, liquefaction treatment is not required, and an appropriate amount of sample is taken directly, the operation of step 2 is carried out, and the cell precipitate is collected by centrifugation.2. Centrifuge at 10000 rpm for 5-10 min at room temperature and carefully discard the supernatant.Note: Do not disturb the lower cell sediment to avoid sample loss.3. Add 500 µl Buffer GB2, vortex to mix, and incubate at room temperature, 600 rpm for 10 min. 4. Centrifuge at 12000 rpm for 2 min and carefully remove the supernatant.Note: Do not disturb the bacterial precipitate when removing the supernatant to avoid sample loss.5. Add 200 µl of Buffer GB2 to the precipitate, add 2 µl of Benzonase and incubate for 30 min at 37°C, 600 rpm. 6. Centrifuge at 12000 rpm for 2 min, discard the supernatant, add 500 µl of Buffer GB2, vortex and wash the precipitate. Repeat the procedure once.7. Centrifuge at 12000 rpm for 2 min, discard the supernatant, and finally aspirate the residual Buffer GB2 with a small-volume tip. 8. Add 180 µl Lysozyme (10 mg/ml), resuspend the bacterial precipitate and transfer the bacterial resuspension to a Lysis Tube.9. The Lysis Tube is incubated at 37°C, 600 rpm for 20-30 min, then vortexed for 10 min or processed on a thermostatic homogenizer for 10 min at maximum vibration speed (2500-2900 rpm).10. Centrifuge briefly, add 20 µl proteinase K, vortex to mix, add 200 µl buffer GL, vortex to mix, and incubate for 30 min at 56°C, 600 rpm. Note: 1) Do not add Proteinase K directly to Buffer GL.2)For RNA removal, add 4 µl DNase-Free RNase A (100 mg/ml) before adding Buffer GL, shake to mix, and let stand at room temperature for 5-10 minutes.11. Centrifuge at 12000 rpm for 1 min and carefully aspirate the supernatant into a new centrifuge tube. Note: Do not aspirate the glass beads.12. Add 200 µl of anhydrous ethanol, vortex to mix, and centrifuge momentarily to collect the solution to the bottom of the tube. Note: The addition of anhydrous ethanol may produce a white precipitate that will not affect subsequent experiments.13. Add all of the solution from step 12, including the precipitate, to the Spin Columns DM in the collection tube, or transfer the solution several times if it cannot be added all at once. centrifuge at 12,000 rpm for 1 minute, pour off the waste from the collection tube, and return the column to the collection tube.14. Add 500 µl Buffer GW1 to the adsorbent column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 min, pour off the waste liquid from the collection tube, and put the adsorbent column back into the collection tube.15. Add 500 µl Buffer GW2 to the adsorbent column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorbent column back into the collection tube. Note: Step 15 can be repeated once if further improvement of DNA purity is required.16. Centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Leave the column at room temperature for a few minutes and dry thoroughly. Note: The purpose of this step is to remove residual ethanol from the adsorbent column; ethanol residue can interfere with subsequent enzymatic reactions (digestion, PCR, etc.).17. Place the adsorbent column in a new centrifuge tube (supplied), add 50 µl of Buffer GE to the center of the adsorbent column overhang, let stand at room temperature for 5 minutes, centrifuge at 12,000 rpm for 1 minute, collect the DNA solution, and store the DNA at -20 °C. Attention:1)If the downstream experiments are sensitive to pH or EDTA, sterilized water can be used for elution. The pH value of the eluent has a great influence on the elution efficiency. If the eluent is made of water, the pH value should be 7.0-8.5 (the pH value of water can be adjusted to this range with NaOH), and the elution efficiency is not high when the pH value is lower than 7.0.2)Incubation at room temperature for 5 minutes prior to centrifugation increases yield.3)If the final concentration of DNA is to be increased, the DNA eluate obtained in step 17 can be re-spiked onto the adsorbent membrane and step 17 repeated. 4)DNA stored in water will be affected by acidic hydrolysis. For long-term storage, it is recommended to elute with Buffer GE and store at -20℃... Read More |