| Description | Inquire | Description:Acetylcholinesterases (AChEs) are enzymes that hydrolyze the neurotransmitter acetylcholine (ACh) to acetate and choline. AChE is located at the synaptic cleft and functions to terminate synaptic transmission by catalyzing the breakdown of ACh allowing cholinergic neurons to Description:Acetylcholinesterases (AChEs) are enzymes that hydrolyze the neurotransmitter acetylcholine (ACh) to acetate and choline. AChE is located at the synaptic cleft and functions to terminate synaptic transmission by catalyzing the breakdown of ACh allowing cholinergic neurons to return to a resting state after activation. It is also found in membranes of red blood cells, motor and sensory fibers, muscles, nerves and central and peripheral tissues. Changes in AChE activity may result from exposure to certain insecticides, which act as cholinesterase inhibitors. Inhibitors of AChE are also used to treat certain conditions such as dementia.Acetylcholinesterase activity assay kit has been used to determine the activity of acetylcholinesterase in a rat organophosphate model and in brain tissue homogenates.Principle:Acetylcholinesterase can catalyze the hydrolysis of acetylcholine to choline, and the reaction of choline with disulfide p-nitrobenzoic acid to produce 5-merhydryl-nitrobenzoic acid (TNB). The product has a characteristic absorption peak at 412 nm, and the activity of acetylcholinesterase can be characterized by the change of light absorption valueThe Dilution Calculator EquationConcentration (start)xVolume (start)= Concentration (final)× Volume (final)This equation is commonly abbreviated as: C1V1 = C2V2... Read More | The bacterial viability / toxicity detection kit contains two fluorescent dyes. Nucgreen is a green nucleic acid dye that can stain live and dead bacteria; Ethd III is a red nucleic acid dye that only stains dead bacteria with damaged cell membranes. When nucgreen and ethd III are properly mixed, The bacterial viability / toxicity detection kit contains two fluorescent dyes. Nucgreen is a green nucleic acid dye that can stain live and dead bacteria; Ethd III is a red nucleic acid dye that only stains dead bacteria with damaged cell membranes. When nucgreen and ethd III are properly mixed, the bacteria with intact cell membrane appear green, while the bacteria with damaged cell membrane can appear green and red under different channels, respectively. A common criterion for bacterial viability is the ability to propagate in a suitable nutrient medium, known as a growth assay. This kit is generally in good agreement with the growth assay results in liquid or solid medium. However, under certain conditions, membrane damaged bacteria may recover and propagate in nutrient medium, and such bacteria will be identified as dead bacteria in this assay. On the contrary, some bacteria with intact membranes may not be able to propagate in nutrient medium, but will be recognized as viable bacteria in this assay. Therefore, if there is a large difference between the test results of this kit and the bacterial growth assay, the above possibilities should be considered. Component: Product parameters: NucGreen: Ex/Em = 503/530 nm (结合 DNA);EthD-III: Ex/Em = 530/620 nm (结合 DNA)。Usage:1 Preparation of control samples for live and dead bacteria (optional)1. Cultivate 4 mL of bacteria in liquid medium until late logarithmic phase.2. Prepare two 1 mL bacterial solutions in an EP tube and centrifuge for 10-15 minutes under 5000-10000 g conditions.3. Remove the supernatant and add 0.3 mL of 0.85% NaCl resuspended bacteria to one of the EP tubes, and 1 mL of 0.85% NaCl resuspended bacteria to the other tube.4. Add 0.7 mL of isopropanol to a tube containing 0.3 mL of 0.85% NaCl, and mix thoroughly (with a final concentration of 70% isopropanol) to prepare a dead bacterial sample.5. Incubate the two samples at room temperature for 1 hour and mix every 15 minutes.6. Centrifuge the two samples at 5000-10000 g for 10-15 minutes.7. Remove the supernatant, add 1 mL of 0.85% NaCl to resuspend the bacteria in both samples, and centrifuge again as in step 6.8. Use a spectrophotometer to measure the absorbance values (OD670) of two bacterial suspensions at 670 nm.9. Adjust the density of the two bacterial suspensions (live and dead) to 108 bacteria/mL (OD670 ≈ 0.3), and then dilute with 0.85% NaCl at 1:100 to achieve a final density of 106 bacteria/mL.10. Mix two bacterial suspensions as shown in the table below to obtain the required live cell ratio: dead cell ratio.Table 1 Mix live and dead bacterial suspensions by a certain volume to achieve the required ratio of live and dead cellsLive cells: Dead cellsVolume of viable bacterial suspension(mL)Volume of dead bacterial suspension(mL)0:10001.010:900.10.920:800.20.830:700.30.750:500.50.5100:01.00II Staining methods for fluorescence microscopy observation1. Mix 1 volume of component A, NucGreen, and 2 volumes of component B, EthD-III, in a microcentrifuge tube. After thorough mixing, add 8 volumes of 0.85% NaCl solution to obtain a 100 x dye solution.2. Every 100 µ L bacterial suspension, add 1 µ 100 x dye solution of L.3. Mix thoroughly and incubate at room temperature in the dark for 15 minutes.4. Take 5 µ The bacterial suspension after L staining was dropped onto a glass slide with an 18 mm square cover glass.5. Observe under a fluorescence microscope. The fluorescence of live and dead bacteria can be observed simultaneously under any standard FITC long-acting filter. Alternatively, live (green fluorescent) and dead (red fluorescent) bacteria can be observed using FITC and Cy3 (or Texas Red) channels, respectively.Attention: (1) Before staining bacteria, attention must be paid to removing residues of growth media. Nucleic acid and other media components can bind to NucGreen and EthD-III dyes in some way, resulting in unacceptable staining changes. A simple washing step is usually sufficient to remove interfering media components from bacterial suspension. It is not recommended to use phosphate buffer solutions as they can reduce staining efficiency. (2) Before starting the formal experiment, the dye concentration should be adjusted to distinguish between NucGreen labeling live bacteria and EthD-III labeling dead bacteria. The optimal concentration may vary depending on the bacterial strain. It is generally best to use the lowest dye concentration that can provide sufficient signal. The above conditions have been optimized for staining live/dead cells of Escherichia coli.III Before starting the staining method experiment of flow cytometry, please read the precautions under the fluorescence microscope staining steps.According to Table 1, add 11 different proportions of live and dead bacteria to the EP tube. Each of the 11 samples has a volume of 1 mL.2. Add 12 µ The A component of L, NucGreen, and 24 µ The B component EthD-III of L was mixed in a microcentrifuge tube. Add 3 to each of the 11 samples µ Mix the mixed dyes of L thoroughly by blowing them up and down several times. (Note: Additional control bacterial samples need to be prepared for separate NucGreen and EthD-III staining)3. Incubate at room temperature in the dark for 15 minutes.4. Analyze each sample using a flow cytometer, detect NucGreen positive cells using FITC channels, and detect EthD-III positive cells using PI or PE channels.Matters needing attention:1. please centrifuge the product to the bottom of the tube immediately before use, and then conduct subsequent experiments. 2. if the orifice plate is used for detection, a small amount of bacterial liquid can be left for imaging after standing for 10 min, which can effectively reduce the background. 3. in order to be closer to the real results, it is recommended to keep the brightness of red fluorescence consistent with that of green fluorescence in merge pictures. 4. fluorescent dyes have quenching problems. Please try to avoid light during experimental operation to slow down fluorescence quenching. 5. for your safety and health, please wear experimental clothes and disposable gloves.Scope of application:Staining of dead and live bacteria... Read More | Product content N665859Component50 TStorageN665859ABuffer DS30 mLRTN665859BBuffer GTL15 mLRTN665859CBuffer GL15 mLRTN665859DBuffer GW1 (concentrate)13 mLRTN665859EBuffer GW2 (concentrate)15 mLRTN665859FBuffer TE10 mLRTN665859GProteinase K2×1.25 mLRTN665859HRNase A (100 mg/mL)0.4 Product content N665859Component50 TStorageN665859ABuffer DS30 mLRTN665859BBuffer GTL15 mLRTN665859CBuffer GL15 mLRTN665859DBuffer GW1 (concentrate)13 mLRTN665859EBuffer GW2 (concentrate)15 mLRTN665859FBuffer TE10 mLRTN665859GProteinase K2×1.25 mLRTN665859HRNase A (100 mg/mL)0.4 mLRTN665859ISpin Columns DF With Collection Tubes50 EA2-8℃N665859JCentrifuge Tubes (L-1.5 mL)50 EART Product IntroductionThis kit is suitable for the effective purification of genomic DNA from formalin-fixed, paraffin-embedded tissues.The product uses specially optimized dewaxing agent and lysis solution to release DNA from formalin-fixed or tissue sectioned samples, which does not involve the organic reagent xylene and does not need to be operated overnight; the digested samples are incubated at higher temperatures to remove formalin cross-linking of the free DNA, which can effectively improve the yield and purity of DNA; the optimized buffer system allows the inhibitors in the lysis solution to be specifically bound to the adsorbent membrane, which can be effectively removed by a two-step rinsing step. The optimized buffer system enables the DNA in the lysate to specifically bind to the adsorbent membrane, and the inhibitor is effectively removed by a two-step rinsing step, and finally eluted with low-salt buffer or water to obtain high-purity DNA.Meanwhile, configured with a high-efficiency microsorbent column, the elution volume can be as low as 20 µL.The purified DNA can be directly used for PCR, Real-time PCR, SNP Genotyping, STR genotyping, second-generation sequencing and pharmacogenomics research.The molecular weight of DNA isolated from formalin-fixed, paraffin-embedded samples is usually lower than that of DNA from fresh or frozen samples.The degree of DNA fragmentation depends on the type of sample, the duration of storage, and the conditions of fixation.Self-contained reagent: anhydrous ethanolPre-experiment Preparation and Important Notes1. After obtaining the sample, fix the sample in 4%-10% formalin as soon as possible, the fixation time should be 14-24 hours, too long a period of time will easily lead to genome breakage, affecting the downstream experiments. If the formaldehyde fixation time is too long or the sample has been stored for too long (> 1 year), it will easily lead to DNA integrity damage and unable to amplify long fragments.2. Ensure that the sample is thoroughly dehydrated before embedding; residual formalin will inhibit Proteinase K.3. Anhydrous ethanol should be added to Buffer GW1 and Buffer GW2 according to the instructions on the label of the reagent bottle before first use.4. Before use, please check Buffer GTL, Buffer GL and Buffer DS for any crystallization or precipitation. If there is any crystallization or precipitation, please re-dissolve Buffer GTL, Buffer GL and Buffer DS at 56℃ in a water bath.5. Preheat the water bath or thermostatic mixer to 56°C and keep the centrifuge at 25°C before starting the experiment.6. If downstream experiments are needed to reduce the low frequency of C>T:G>A transitions (artificial mutations) that occur to minimize the risk of false positives, 7 µL of UNG (1 U/uL) can be added after 1 hour of incubation at 90°C.Operation steps1. Sample processing:1a. Paraffin-embedded samples: Trim off excess paraffin from the tissue block with a scalpel to expose the tissue and then cut into 5-10µm slices. Take about 1×1cm2 slices (about 4-5 slices in total) and place them in a centrifuge tube (provided), add 160µL Buffer DS, vortex and shake for 10 seconds, then add 180µL Buffer GTL and 20µL Proteinase K, vortex and shake for 10 seconds. centrifuge the samples at 12,000rpm for 1 minute at 25℃.Note: 1) If the surface of the sample has been exposed to air, discard the 2-3 pieces that have been exposed to air and do not use them.2) DS will solidify below 18°C, and if it does it does not affect the following experiments.1b. Sample in formalin and other fixative: take about 20mg of sample, cut it into small pieces, place it in a centrifuge tube, add 500µL of 10mM PBS (PH7.4), vortex shaking, centrifuge at 12,000rpm for 1minute, discard the supernatant, and repeat 3 times. Add 180 µL Buffer GTL, 20 µL Proteinase K, vortex shaking to mix.2.56°C for 1 hour until the sample is completely dissolved. incubate at 90°C for 1 hour. centrifuge at 12,000 rpm, 25°C for 1 minute, and carefully pipette the lower aqueous phase (~180 µL) along the wall of the tube into a new centrifuge tube, trying to avoid aspirating the bottom precipitate and the upper layer of the wax solution.Note: 1) Samples can be left at room temperature after incubation at 56°C until the temperature of the water or dry bath reaches 90°C before placing the samples at 90°CIncubation.2) Optional step: add 7µL UNG (1U/µL), 50°C, 5min, no shaking. The purpose of this step is to minimize the risk of false positives by reducing the low-frequency occurrence of C>T:G>A transitions (artificial mutations) while effectively retaining the true occurrence of mutations.3. Optional step: If you need to remove RNA, you can lower the temperature of the sample to room temperature, then add 2µL of RNase A solution at a concentration of 100mg/mL, shake and mix well, and leave it at room temperature for 2 minutes.4. Add 20µL Proteinase K and incubate at 65℃, 450rpm for 15min.5. Add 200 µL of Buffer GL, mix well by vortexing and shaking, then add 200 µL of anhydrous ethanol and mix thoroughly by vortexing and shaking. Centrifuge briefly so that the solution on the wall of the tube collects at the bottom of the tube.Note: 1) Mix well immediately after adding Buffer GL and anhydrous ethanol.2) The addition of Buffer GL and anhydrous ethanol may produce a white precipitate that will not affect subsequent experiments.3) If more than one sample needs to be manipulated, the Buffer GL and anhydrous ethanol can be pre-mixed and spiked.6. Add all the solution obtained in step 5 to the adsorption columns (Spin Columns DF) that have been loaded into the collection tube, centrifuge at 25℃, 12000rpm for 2 minutes, pour out the waste liquid in the collection tube, and put the adsorption columns back into the collection tube.7. Add 500µL of Buffer GW1 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12,000rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorption column back into the collection tube.8. Add 500µL of Buffer GW2 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12000rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorption column back into the collection tube.Note: Step 8 can be repeated if further DNA purity is required.9.12 Centrifuge at 2000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Leave the adsorption column at room temperature for several minutes to dry thoroughly.Note: The purpose of this step is to remove residual ethanol from the adsorption column; ethanol residue can interfere with subsequent enzymatic reactions.10. Place the adsorption column in a new 1.5 mL collection tube, add 20-100 µL of Buffer TE or sterilized water to the middle of the adsorption column overhanging the column, let it stand at room temperature for 2-5 minutes, centrifuge it at 12,000 rpm for 1 minute, and collect the DNA solution.-20°C to preserve DNA.Note: 1) The pH value of the eluent has a great influence on the elution efficiency, if water is used as the eluent should ensure that its pH value is 7.0-8.5, the pH value is lower than 7.0 when the elution efficiency is not high.2) If the final concentration of DNA is to be increased, the DNA eluate obtained in step 10 can be re-spiked onto the adsorbent membrane and left at room temperature for 2 minutes and centrifuged at 12,000 rpm for 1 minute... Read More | Product content: U665923Component50 T200 TStorageU665923ABuffer GTL15 mL60 mLRTU665923BBuffer GL15 mL50 mLRTU665923CBuffer GW1 (concentrate)13 mL52 mLRTU665923DBuffer GW2 (concentrate)15 mL70 mLRTU665923EBuffer GE15 mL60 mLRTU665923FProteinase K1.25 mL4×1.25 mLRTU665923GSpin Columns DM with Product content: U665923Component50 T200 TStorageU665923ABuffer GTL15 mL60 mLRTU665923BBuffer GL15 mL50 mLRTU665923CBuffer GW1 (concentrate)13 mL52 mLRTU665923DBuffer GW2 (concentrate)15 mL70 mLRTU665923EBuffer GE15 mL60 mLRTU665923FProteinase K1.25 mL4×1.25 mLRTU665923GSpin Columns DM with Collection Tubes50 EA200 EART Product Introduction:This reagent kit is suitable for extracting high-purity total DNA from various samples such as fresh or frozen animal tissues, cells, blood, bacteria, etc. This product can purify DNA fragments with a maximum molecular weight of 50 kb. The purification process does not require the use of toxic solvents such as phenol or chloroform, nor does it require ethanol precipitation. This reagent kit adopts an optimized buffer system to efficiently and specifically bind DNA from the lysis solution to the silica matrix centrifuge adsorption column. Inhibitors of PCR and other enzymatic reactions can be effectively removed through a two-step washing step. Finally, high-purity DNA can be obtained by washing with low salt buffer or water. The purified DNA can be directly used for downstream experiments such as enzyme digestion, PCR, Real Time PCR, library construction, Southern Blot, and molecular labeling.Self prepared reagent: anhydrous ethanolEnzymatic Lysis Buffer (preparation required for extracting genomic DNA from Gram positive bacteria).Self prepared reagent: Enzymatic Lysis Buffer Formula: 20 mM Tris, pH 8.0; 2 mM Na2 EDTA; 1.2% Triton self prepared reagent: X-100; Lysozyme with a final concentration of 20 mg/mL.Preparation and important precautions before the experiment:1. Samples should avoid repeated freeze-thaw cycles, otherwise it may result in smaller extracted DNA fragments and a decrease in extraction volume.2.If extracting the genome of bacterial cultures with a large accumulation of secondary metabolites or thick cell walls, it is recommended to collect samples early in the logarithmic growth phase.3.Before the first use, anhydrous ethanol should be added to Buffer GW1 and Buffer GW2 according to the instructions on the reagent bottle label.4. Before use, please check if there is any crystallization or precipitation in Buffer GTL and Buffer GL. If there is any crystallization or precipitation, please dissolve Buffer GL and Buffer GTL again in a 56 ℃ water bath.5. If downstream experiments are sensitive to RNA contamination, 4 can be added before adding Buffer GL µ RNase A of L DNase Free (100 mg/mL) was not provided in this kit.Operation steps:Genome extraction from blood and cell samples1. Material processing1a If the extracted material is mammalian anticoagulant blood (non nucleated red blood cells), it can be directly directed to 50-200 µ Add Buffer GTL to fresh or frozen anticoagulant blood samples to supplement up to 200 µ L;1b If the extracted material is anticoagulant blood from poultry, birds, amphibians, or lower level organisms, and their red blood cells are nucleated cells, take 5-10 µ L fresh or frozen anticoagulant blood samples, add Buffer GTL to supplement up to 200 µ L;1c The cells cultured on the wall should be first processed into a cell suspension (with a maximum extraction amount of 5 × 10 cells), centrifuged at 2000 rpm (400 × g) for 5 minutes, discarded from the supernatant, and added with 200 µ L GTL, oscillate until the sample is completely suspended;Note: To remove RNA, add 4 after completing the above steps µ RNase A solution with a concentration of 100 mg/mL was vortexed for 15 seconds and left at room temperature for 2 minutes.2. Add 20 µ L Protein K.3. Add 200 µ L Buffer GL, vortex oscillation thoroughly mixed, 56 ℃ water bath for 10 minutes.4. Temporarily centrifuge to remove water droplets from the inner wall of the tube cover. Join 200 µ L anhydrous ethanol, vortex and shake thoroughly to mix well. Short centrifugation.Attention: 1) After adding Bu ff er GL and anhydrous ethanol, immediately vortex shake and mix well.2) The addition of Bu ff er GL and anhydrous ethanol may produce white precipitates, which will not affect subsequent experiments. Some organizations may form sol-gel products after adding Bu ff er GL and anhydrous ethanol, and it is recommended to perform severe shaking or vortex treatment at this time.5. Add all the solutions obtained in the previous step to the spin columns DM that have been loaded into the collection tube. If the solution cannot be added at once, it can be transferred multiple times. Centrifuge at 12000 rpm (~13400 × g) for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.6. Add 500 to the adsorption column µ L Buffer GW1 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.7. Add 500 to the adsorption column µ L Buffer GW2 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.Note: To further improve DNA purity, repeat step 7.8.12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).9. Place the adsorption column in a new centrifuge tube (provided by oneself) and add 50-200 to the middle of the adsorption column in the air µ L Buffer GE or sterilized water, leave at room temperature for 2-5 minutes, centrifuge at 12000 rpm for 1 minute, collect DNA solution, and store DNA at -20 ℃.Attention:1) If downstream experiments are sensitive to pH or EDTA, they can be washed off with sterilized water. The pH value of the eluent has a significant impact on the elution efficiency. If water is used as the eluent, its pH value should be ensured to be between 7.0-8.5 (NaOH can be used to adjust the pH value of the water to this range). When the pH value is below 7.0, the elution efficiency is not high.2) Preheating the GE in a water bath at 65-70 ℃ and incubating it at room temperature for 5 minutes before centrifugation can increase yield; Use an additional 50-200 µ Re washing with GE or sterilized water can increase yield.3) If the final concentration of DNA needs to be increased, the obtained solution can be re added to the adsorption column, left at room temperature for 2-5 minutes, and centrifuged at 12000 rpm for 1 minute; If the elution volume is less than 200 µ L. It is possible to increase the final concentration of DNA, but it may reduce the total yield. If the amount of DNA is less than 1 µ g. Recommended 50 µ Wash with GE or sterilized water.4) Because DNA stored in water is affected by acidic hydrolysis, if long-term preservation is required, it is recommended to elute with Bu ff er GE and store at -20 ℃.Genome extraction from animal tissues1. Material processingIf the extracted material is animal tissue, take 25 mg (the amount of spleen tissue should be less than 10 mg); If the material is mouse tail, take a section of rat tail with a length of 0.4-0.6 cm or two sections of mouse tail with a length of 0.4-0.6 cm.1a. After liquid nitrogen grinding or cutting the sample into small pieces, place it in a 1.5 mL centrifuge tube and add 180 mL µ Label different samples with L Buffer GTL.1b If using a homogenizer to process the sample, add no more than 80% of the homogenizer to the sample before homogenization µ L Buffer GTL, add 100 after homogenization µ L Buffer GTL.Attention:1) Ensure that the quantity of each organization does not exceed the recommended range.2) The tissue samples can be ground with liquid nitrogen or homogenized with a homogenizer before adding Bu ff er GTL, which can increase the cracking efficiency.2. Add 20 µ L Protein K, vortex oscillation thoroughly mixes the sample. Take a 56 ℃ water bath until the tissue is completely lysed. During the incubation process, the centrifuge tube can be inverted or shaken periodically to disperse the sample.Attention:1) The digestion time varies for different tissues, usually taking 1-3 hours to complete. The tail of the mouse needs to be digested for 6-8 hours, and if necessary, overnight digestion will not affect subsequent operations.2) If there is still gel like substance after incubation and vortex oscillation, extend the incubation time at 56 ℃ or add another 20 µ L Protein K digestion.3) To remove RNA, add 4 after completing the above steps µ RNase A solution with a concentration of 100 mg/mL, vortex for 15 seconds, and leave at room temperature for 5-10 minutes.3. Add 200 µ L Buffer GL, vortex shake thoroughly and mix well, take a water bath at 70 ℃ for 10 minutes. Add 200 after brief centrifugation µ L anhydrous ethanol, vortex and shake thoroughly to mix well.Attention:1) After adding Bu ff er GL and anhydrous ethanol, immediately vortex and shake to mix well.2) The addition of Bu ff er GL and anhydrous ethanol may produce white precipitates, which will not affect subsequent experiments. Some tissues (such as the spleen and lungs) may form sol-gel products after adding Bu ff er GL and anhydrous ethanol. In this case, it is recommended to perform vigorous shaking or vortex treatment.4. Centrifuge briefly and add all the solution obtained in step 3 to the spin columns DM that have been loaded into the collection tube. If the solution cannot be added at once, it can be transferred multiple times. Centrifuge at 12000 rpm (~13400 × g) for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.5. Add 500 to the adsorption column µ L Buffer GW1 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.6. Add 500 to the adsorption column µ L Buffer GW2 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.Note: To further improve DNA purity, repeat step 6.7.12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).8. Place the adsorption column in a new centrifuge tube (provided by oneself) and add 50-200 to the middle of the adsorption column in the air µ L Buffer GE or sterilized water, leave at room temperature for 2-5 minutes, centrifuge at 12000 rpm for 1 minute, collect DNA solution, and store DNA at -20 ℃.Attention:1) If downstream experiments are sensitive to pH or EDTA, they can be washed off with sterilized water. The pH value of the eluent has a significant impact on the elution efficiency. If water is used as the eluent, its pH value should be ensured to be between 7.0-8.5 (NaOH can be used to adjust the pH value of the water to this range). When the pH value is below 7.0, the elution efficiency is not high.2) Preheating the GE in a water bath at 65-70 ℃ and incubating it at room temperature for 5 minutes before centrifugation can increase yield; Use an additional 50-200 µ Re washing with GE or sterilized water can increase yield.3) If the final concentration of DNA needs to be increased, the obtained solution can be re added to the adsorption column, left at room temperature for 2-5 minutes, and centrifuged at 12000 rpm for 1 minute; If the elution volume is less than 200 µ L. It is possible to increase the final concentration of DNA, but it may reduce the total yield. If the amount of DNA is less than 1 µ g. Recommended 50 µ Wash with GE or sterilized water.4) Because DNA stored in water is affected by acidic hydrolysis, if long-term preservation is required, it is recommended to elute with Bu ff er GE and store at -20 ℃. i ii Genomic extraction of blood and cell samples1. Bacterial sample pretreatment1a Gram negative bacteria(1) Take 1-5mL of bacterial culture (10 ^ -10 ^ cells, up to a maximum of 2 × 10 ^ cells) and place it in a centrifuge tube (self prepared). Centrifuge at 12000 rpm (~13400 × g) for 1 minute and try to aspirate the supernatant as much as possible.(2) Add 180 to the precipitate µ L Buffer GTL, shake to suspend bacterial weight.(3) Join 20 µ L Protein K, vortex mix well, incubate at 56 ° C until the bacterial cell is completely lysed, and during the incubation process, invert or shake the centrifuge tube periodically to disperse the sample.Note: To remove RNA, add 4 after completing the above steps µ L RNase A solution with a concentration of 100 mg/mL, shake well and let stand at room temperature for 5-10 minutes.(4) Join 200 µ L Buffer GL, vortex oscillation mixing.1b Gram positive bacteria(1) Take 1-5 mL of bacterial culture (10 ^ -10 ^ cells, maximum not exceeding 2 x 10 ^ cells) and place it in a centrifuge tube (self prepared). Centrifuge at 12000 rpm for 1 minute and try to aspirate the supernatant as much as possible.(2) Join 180 µ L Enzymatic Lysis Buffer (self provided) suspends the bacterial weight.(3) Incubate at 37 ℃ for 30 minutes.(4) Join 20 µ L Protein K vortex oscillation, thoroughly mixed. Join 200 µ L Buffer GL, vortex oscillation mixing. Incubate at 56 ℃ for 30 minutes.Attention:1) If necessary, incubation at 95 ° C for 15 minutes can inactivate the pathogen, but incubation at 95 ° C can cause some DNA degradation.2) To remove RNA, add 4 after completing the above steps µ L RNase A solution with a concentration of 100 mg/mL, shake well and let stand at room temperature for 5-10 minutes.2. Add 200 µ L anhydrous ethanol, vortex and shake thoroughly to mix well.Attention: Adding anhydrous ethanol may produce white precipitates, which will not affect subsequent experiments.3. Add all the solution obtained from step 2 (including the formed precipitate) to the adsorption column (Spin Columns DM) that has been loaded into the collection tube. If the solution cannot be added at once, it can be transferred multiple times. Centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.4. Add 500 to the adsorption column µ L Buffer GW1 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.5. Add 500 to the adsorption column µ L Buffer GW2 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.Note: To further improve DNA purity, repeat step 5.6.12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).7. Place the adsorption column in a new centrifuge tube (provided by oneself) and add 50-200 to the middle of the adsorption column in the air µ L Buffer GE or sterilized water, leave at room temperature for 2-5 minutes, centrifuge at 12000 rpm for 1 minute, collect DNA solution, and store DNA at -20 ℃.Attention:1) If downstream experiments are sensitive to pH or EDTA, they can be washed off with sterilized water. The pH value of the eluent has a significant impact on the elution efficiency. If water is used as the eluent, its pH value should be ensured to be between 7.0-8.5 (NaOH can be used to adjust the pH value of the water to this range). When the pH value is below 7.0, the elution efficiency is not high.2) Preheating the GE in a water bath at 65-70 ℃ and incubating it at room temperature for 5 minutes before centrifugation can increase yield; Use an additional 50-200 µ Re washing with GE or sterilized water can increase yield.3) If the final concentration of DNA needs to be increased, the obtained solution can be re added to the adsorption column, left at room temperature for 2-5 minutes, and centrifuged at 12000 rpm for 1 minute; If the elution volume is less than 200 µ L. It is possible to increase the final concentration of DNA, but it may reduce the total yield. If the amount of DNA is less than 1 µ g. Recommended 50 µ Wash with GE or sterilized water.4) Because DNA stored in water is affected by acidic hydrolysis, if long-term preservation is required, it is recommended to elute with Bu ff er GE and store at -20 ℃... Read More |