| Description | Inquire | Inquire | Product content Q665687Component100 TStorageQ665687AQuick T4 DNA Ligase (15 U/µL)100 µL-20℃. Avoid freeze/thaw cycle.Q665687B2×Quick Ligation Reaction Buffer5×200 µL-20℃. Avoid freeze/thaw cycle. Product IntroductionThe Quick Ligation Reaction Kit allows ligationProduct content Q665687Component100 TStorageQ665687AQuick T4 DNA Ligase (15 U/µL)100 µL-20℃. Avoid freeze/thaw cycle.Q665687B2×Quick Ligation Reaction Buffer5×200 µL-20℃. Avoid freeze/thaw cycle. Product IntroductionThe Quick Ligation Reaction Kit allows ligation of DNA sticky or flush ends in 5 minutes at room temperature (25°C). The kit contains Quick T4 DNA Ligase and 2×Quick Ligation Reaction Buffer optimized for fast and efficient DNA ligation.The ligation efficiency of Quick Ligation is equivalent to 1 hour of conventional ligation with T4 DNA Ligase. The Quick Ligation products can be used directly in routine bacterial transformation experiments.matters needing attention1. This kit enables most of the linkage reactions to reach the reaction endpoint within 5 minutes or less at 25°C. Increasing the reaction time will not enhance the reaction efficiency. If you use the rapid connection reaction after 1 hour, the conversion efficiency will be significantly reduced; if the rapid connection reaction at 25 ℃ overnight, the conversion efficiency will drop to 75%.2. 2×Quick Ligation Reaction Buffer contains ATP, which should be thawed on ice and mixed thoroughly before use. It is recommended to freeze the buffer in small tubes for the first time, so as to avoid repeated freezing and thawing, which will affect the efficiency of DNA ligation.3. Since T4 DNA Ligase contains glycerol, which is sticky and easy to hang on the wall, it is recommended to collect the liquid to the bottom of the tube by centrifugation for a short period of time before use, and the tip of the lance should not go too deep into the liquid surface when taking samples to avoid sticking to the tip of the lance and causing losses.4. If the quick ligation product is used for electrotransformation, the PEG in the quick ligation reaction system will affect the efficiency of electrotransformation, and it is recommended to use a centrifugal column to purify the ligation product from DNA before electrotransformation.Usage1. The reaction solution was prepared according to the following system:*The amount of Insert DNA used: the molar ratio of Vector DNA and Insert DNA is generally 1:3-1:8, and the appropriate molar ratio of Vector DNA and Insert DNA can be selected according to the experimental situation.Calculation of DNA molar number: DNA molar number (nmol)=DNA mass (ng)/( 660daltons x number of inserted DNA bases bp).2. mix gently and centrifuge briefly. react at 25°C for 5 minutes.Note: The reaction time should not exceed 15 minutes, otherwise the connection efficiency will be reduced.3. Do not perform heat inactivation reactions. Centrifuge instantly and collect the solution from the wall to the bottom of the tube.Note: Heat inactivation significantly reduces transformation efficiency due to the presence of PEG in the buffer.4. After the reaction, store the DNA ligation product at 0-4℃, and then carry out transformation experiments; you can also store the DNA ligation product at -20℃.Note: When transforming by chemical method, do not add more than 10% of the volume of the receptor cell for the ligation product.5. Heat shock the ligation product to transform 50 µl of receptor cells or take 1-2 µl of ligation product to electroshock transform 50 µl of receptor cells.Note: 1) When transforming by chemical method, do not add more than 10% of the volume of the receptor cell for the ligation product.(2) If the quick ligation product is used for electrotransformation, it is recommended to use a centrifugal column to purify the ligation product from DNA before electrotransformation because the PEG in the quick ligation reaction system will affect the efficiency of electrotransformation... Read More | RAFT Agent Kit for controlling polymerizations at the molecular level detailed list of products: Catalog Number Product Name Component Catalog Number Component Name Component CAS Specification&Purity R396714 RAFT Agent Kit for controlling polymerizations at the molecular level C139356-500mg 4-RAFT Agent Kit for controlling polymerizations at the molecular level detailed list of products: Catalog Number Product Name Component Catalog Number Component Name Component CAS Specification&Purity R396714 RAFT Agent Kit for controlling polymerizations at the molecular level C139356-500mg 4-Cyano-4-(dodecylsulfanylthiocarbonyl)sulfanylpentanoic acid 870196-80-8 See Component Catalog Number R396714 RAFT Agent Kit for controlling polymerizations at the molecular level C396701-500mg Cyanomethyl dodecyl trithiocarbonate 796045-97-1 See Component Catalog Number R396714 RAFT Agent Kit for controlling polymerizations at the molecular level C396703-500mg Cyanomethyl methyl(phenyl)carbamodithioate 76926-16-4 See Component Catalog Number R396714 RAFT Agent Kit for controlling polymerizations at the molecular level C168358-500mg 2-Cyano-2-propyl benzodithioate 201611-85-0 See Component Catalog Number R396714 RAFT Agent Kit for controlling polymerizations at the molecular level C396706-500mg 2-(2-Cyanoprop-2-yl)-S-dodecyltrithiocarbonate 870196-83-1 See Component Catalog Number R396714 RAFT Agent Kit for controlling polymerizations at the molecular level C132316-500mg 4-Cyano-4-(phenylcarbonothioylthio)pentanoic Acid 201611-92-9 See Component Catalog Number R396714 RAFT Agent Kit for controlling polymerizations at the molecular level S396708-500mg S,S-Dibenzyl trithiocarbonate 26504-29-0 See Component Catalog Number R396714 RAFT Agent Kit for controlling polymerizations at the molecular level D396711-500mg 2-(Dodecylthiocarbonothioylthio)-2-methylpropionic acid 461642-78-4 See Component Catalog Number... Read More | This reagent kit uses an adsorption column that can specifically bind to viral RNA and a unique buffer system, suitable for isolating viral RNA from cell-free body fluids such as serum, plasma, urine, cerebrospinal fluid, and cell culture supernatants. The viral RNA specifically binds to the siliconThis reagent kit uses an adsorption column that can specifically bind to viral RNA and a unique buffer system, suitable for isolating viral RNA from cell-free body fluids such as serum, plasma, urine, cerebrospinal fluid, and cell culture supernatants. The viral RNA specifically binds to the silicon substrate membrane, and pollutants flow through the membrane. Completely remove impurities such as proteins through two efficient washes, and then wash high-purity viral RNA with RNase free water or RNase Free Water provided by the reagent kit. The virus RNA extracted by this kit can be directly used for experiments such as RT-PCR, Real time RT-PCR, and Western blot analysis. R666005Component50 TStorageR666005ABuffer GL15 mLRTR666005BBuffer RW140 mLRTR666005CBuffer RW2(concentrate)11 mLRTR666005DProteinase K12.5 mgRTR666005EProteinase K Storage Buffer1.25 mLRTR666005FRNase-Free Water10 mLRTR666005GSpin Columns RS with Collection Tubes50 setsRTR666005HRNase-Free Centrifuge Tubes(1.5 mL)50 EART Self prepared reagent: anhydrous ethanol, 0.9% NaCl.Preparation and important precautions before the experiment1. Add 1.25 ml of Protein K Storage Buffer to Protein K to dissolve it and store at -20 ℃. The prepared Protein K should not be left at room temperature for a long time to avoid repeated freeze-thaw cycles, which may affect its activity.2. To prevent RNase pollution, attention should be paid to the following aspects:1) Use RNase free plastic products and gun heads to avoid cross contamination.2) Glassware should be dry baked at a high temperature of 180 ℃ for 4 hours before use, while plastic containers can be soaked in 0.5 M NaOH for 10 minutes, thoroughly rinsed with water, and then sterilized under high pressure.3) Prepare the solution using water without RNase.4) Operators should wear disposable masks and gloves, and change gloves frequently during the experiment.3. Serum or plasma should avoid repeated freeze-thaw cycles that may cause protein denaturation or precipitation, reduce viral titers, and thus affect the yield of extracted viral nucleic acids.4. Before the first use, anhydrous ethanol should be added to Buffer RW2 according to the instructions on the reagent bottle label.5. If buffer GL precipitates, it can be heated at 56 ℃ to dissolve and then placed at room temperature.6. All centrifugation steps should be carried out at room temperature unless otherwise specified, and all operation steps should be carried out quickly.Operation steps1. Take 200 at room temperature µ Add serum or plasma to a 1.5 ml centrifuge tube (self provided). Attention: Less than 200 µ 0.9% NaCl (provided by the customer) can be added to make up for it.2. Add 20 to the solution in the previous step µ Protein K, mix well.3. Add 200 µ L Buffer GL, vortex oscillation for 15 seconds. Note: Do not directly add Protein K to Buffer GL. 4. Incubate at 56 ℃ for 15 minutes, briefly centrifuge, and collect the solution on the tube wall to the bottom of the tube.5. Add 250 µ Anhydrous ethanol, vortex for 15 seconds, incubate at room temperature for 5 minutes, briefly centrifuge, and collect the solution from the tube wall to the bottom of the tube.6. Add all the solution obtained in step 5 to the Spin Columns RS that have been loaded into the collection tube. If it is not possible to add all the solution to the adsorption column at once, please transfer it in two batches, centrifuge at 12000 rpm (~13400 × g) for 1 minute, discard the waste liquid in the collection tube, and put the adsorption column back into the collection tube.7. Add 500 to the adsorption column µ Centrifuge at 12000 rpm for 1 minute, discard the waste liquid from the collection tube, and place the adsorption column back into the collection tube.8. Add 500 to the adsorption column µ Buffer RW2 (check if anhydrous ethanol is added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.9. Add 500 to the adsorption column µ Centrifuge anhydrous ethanol at 12000 rpm for 1 minute, discard the waste liquid from the collection tube, and place the adsorption column back into the collection tube. 10. Centrifuge at 12000 rpm for 3 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry.Attention:1) The purpose of this step is to remove residual ethanol from the adsorption column, which will affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).2) Recommended steps: Place the adsorption column into a new 1.5 ml centrifuge tube (provided), open the tube cover, and incubate in a 56 ℃ oven for 3 minutes to thoroughly dry the membrane of the adsorption column.11. Place the adsorption column in a new RNase free centrifuge tube and add 20-50 to the middle of the adsorption column in the air µ Place RNase Free Water at room temperature for 5 minutes, centrifuge at 12000 rpm for 1 minute, collect RNA solution, and store RNA at -70 ℃ to prevent degradation.Attention:1) The volume of RNase Free Water should not be less than 20 µ l. Small volume affects the recovery rate.2) If you want to increase RNA production, you can use 20-50 µ Repeat step 11 for the new RNase Free Water.3) If you want to increase the RNA concentration, you can add the obtained solution back to the adsorption column and repeat step 11... Read More |