| Description | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export | EndoFree Plasmid Midi Kit Cat No. Component Size(50T) Storage E665631A Buffer P1 30 mL RT E665631B Buffer P2 30 mL RT E665631C Buffer E3 30 mL RT E665631D Buffer PS 15 mL RT E665631E Buffer PW (concentrate) 10 mL RT E665631F Endo-free Buffer EB 10 mL RTEndoFree Plasmid Midi Kit Cat No. Component Size(50T) Storage E665631A Buffer P1 30 mL RT E665631B Buffer P2 30 mL RT E665631C Buffer E3 30 mL RT E665631D Buffer PS 15 mL RT E665631E Buffer PW (concentrate) 10 mL RT E665631F Endo-free Buffer EB 10 mL RT E665631G RNase A (10 mg/mL) 600 µL RT E665631H Buffer ER 8 mL RT E665631I CWBlue 300 µL RT E665631J Spin Columns DL with Collection Tubes 50 EA RT E665631K Endo-Remover FM with Collection 50 EA RTProduct Introduction:Endotoxins are a common pollutant in plasmid extraction. Due to the high sensitivity of eukaryotic cells to endotoxins, the presence of endotoxins in plasmids can greatly reduce the transfection efficiency of eukaryotic cells. This reagent kit provides a simple, fast, and efficient new method for extracting endotoxin free plasmids. The extracted plasmids can remove endotoxins to the maximum extent possible and effectively remove contamination of genomic DNA, RNA, proteins, and other substances. This reagent kit is suitable for extracting 5-15mL of bacterial solution. On the basis of alkaline lysis of cells, it efficiently and specifically binds plasmid DNA through a new silicon-based membrane. Each adsorption column can adsorb up to 100 µ The plasmid DNA of g is effectively removed using a special buffer system and endotoxin removal filter column, effectively removing impurities such as endotoxins and proteins. The plasmid obtained from this kit has high purity and stable quality, making it particularly suitable for cell transfection. It can also be used for downstream experiments such as DNA sequencing, PCR, PCR based mutations, in vitro transcription, transformed bacteria, and endonuclease digestion.Self prepared reagents: anhydrous ethanol, isopropanol.Preparation and important precautions before the experiment:1. All components can be stably stored in a dry, room temperature (15-30 ℃) environment for 1 year, and can be stored at 2-8 ℃ for longer periods of time. Buffer P1 with RNase A added can be stably stored at 2-8 ℃ for 6 months.2. Before the first use, add all RNase A solution to Buffer P1, mix well, and store at 2-8 ℃. Before use, let it sit at room temperature for a period of time. After returning to room temperature, use.3.Before the first use, anhydrous ethanol should be added to the Buffer PW according to the instructions on the reagent bottle label.4. Before use, please check if there is any crystallization or precipitation in Buffer P2 and Buffer E3. If there is any crystallization or precipitation, you can take a water bath at 37 ℃ for a few minutes to restore clarity.5. Be careful not to come into direct contact with Buffer P2 and Buffer E3, and immediately cover them tightly after use.6.The amount and purity of plasmid extraction are related to factors such as bacterial culture concentration, strain type, plasmid size, and plasmid copy number.Operation steps:1. Take 5-15 mL of overnight cultured bacterial solution and add it to a centrifuge tube (self provided). Centrifuge at 13000 rpm (~16200 × g) for 1 minute to collect bacteria, and try to discard all the supernatant as much as possible.2. Add 500 to the centrifuge tube containing bacterial sediment µ L Buffer P1 (please check if RNase A has been added first), mix thoroughly with a pipette or vortex oscillator, and suspend bacterial precipitation. Attention: If the bacterial blocks are not thoroughly mixed, it will affect the cracking effect, resulting in low extraction amount and purity.3. Add 500 to the centrifuge tube µ L Buffer P2, gently invert and mix 8-10 times, allowing the bacterial cells to fully lyse. Leave at room temperature for 3-5 minutes. At this point, the solution should become clear and viscous. Attention: Mix gently and do not shake vigorously to avoid interrupting genomic DNA and mixing genomic DNA fragments in the extracted plasmid. If the solution does not become clear, it indicates that the bacterial count may be too high and the lysis may not be complete. The bacterial count should be reduced.4. Add 500 to the centrifuge tube µ L Buffer E3, immediately invert and mix 8-10 times until white flocculent precipitates appear. Let it stand at room temperature for 5 minutes. Centrifuge at 13000 rpm for 5 minutes, extract the supernatant, and add it to the filter column (Endo Remove FM) (already loaded into the collection tube). Centrifuge at 13000 rpm for 1 minute to filter, then transfer the filtrate from the collection tube to the centrifuge tube (self provided). Attention: 1) After adding Buffer E3, it should be immediately mixed to avoid local precipitation. 2) The maximum volume of the adsorption column is 750 µ L. So please filter the supernatant twice and mix it in the same self provided centrifuge tube.5. Add 450 to the filtrate µ Mix L isopropanol upside down.6. Column balance: Add 200 to the spin columns DL that have been loaded into the collection tube µ L Buffer PS, centrifuge at 13000 rpm for 2 minutes, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.7. Transfer the mixed solution of filtrate and isopropanol from step 5 to an equilibrium adsorption column (already loaded into a collection tube). 8.13000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube. Attention: The maximum volume of the adsorption column is 750 µ L. So the solution obtained in step 5 is divided multiple times and passed through the column. 9. Add 750 to the adsorption column µ L Buffer PW (please check if anhydrous ethanol has been added first), centrifuge at 13000 rpm for 1 minute, and discard the waste liquid in the collection tube.10. Place the adsorption column back into the recovery manifold and centrifuge at 13000 rpm for 1 minute.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).11. Place the adsorption column in a new centrifuge tube (self provided)... Read More | Inquire | Products contentProducts IntroductionThis product uses the principle that the difference between the concentration of salt ions inside and outside the cell can cause the cell membrane to burst to lyses the cell and releases the genomic DNA, without the need of extracting and purifying the genomic Products contentProducts IntroductionThis product uses the principle that the difference between the concentration of salt ions inside and outside the cell can cause the cell membrane to burst to lyses the cell and releases the genomic DNA, without the need of extracting and purifying the genomic DNA.This product is suitable for a variety of sources of samples, and can be used as a template for PCR and qPCR experiments after sample processing, and can achieve the effect of the purified DNA used as a template for PCR and qPCR experiments. Usage1. Depending on the type of sample, prepare the appropriate sample size according to the table below.2. Add the sample to a 1.5-mi centrifuge tube and add the recommended volume of Solution A as shown in the table below. Vortex for 20 s and allow to stand at room temperature for 3-5 min or incubate in a metal bath at 95°C for 3-5 min as recommended in the table below.3. After the sample has been sufficiently lysed (samples incubated in a metal bath at 95°C should be brought to room temperature), add the recommended volume of Solution B as shown in the table below and vortex for 30s.4. Store processed samples at 4°C if the next test is to be performed within 2 hours, or at -20°C if the next test cannot be performed immediately.take note of1) Depending on the requirements of the experimental conditions, the amount of samples can be expanded or reduced, and the amount of Solution A and Solution B can be increased in equal proportions.2) For blood and cell samples, the temperature of room temperature lysis is required to be around 25C. If the ambient temperature does not reach 25°, the lysis time can be extended appropriately, or the vortex shaking time can be extended to ensure that the samples are fully lysed. If there is no relevant professional instrument, the centrifuge tube can be shaken vigorously to ensure adequate lysis.3) After the tissue sample is made into tissue homogenate by adding 10 times the volume of saline, it can be processed in the same way as blood samples.4) Strictly prohibit the use of expired products, please do not mix different reagents.5) laboratory supplies should be regularly cleaned and 10% of the 84 disinfectant solution or ultraviolet lamp for anti-pollution treatment, special areas dedicated to prohibit cross use, so as to avoid contamination, the end of the test, the bench should be cleaned immediately... Read More | This reagent kit is based on TRIzon's improved columnar total RNA extraction kit. This product can be extracted from animal groupsExtract total RNA from samples such as textiles, plant materials, various microorganisms, and cultured cells. Firstly, the cracking solution is fully cracked This reagent kit is based on TRIzon's improved columnar total RNA extraction kit. This product can be extracted from animal groupsExtract total RNA from samples such as textiles, plant materials, various microorganisms, and cultured cells. Firstly, the cracking solution is fully cracked andHomogenized samples, in their unique high salt state, RNA specifically binds to silicon matrix membranes, greatly reducingEffectively removing organic solvent contamination while removing protein contamination, resulting in higher purity and quality of RNA. bookThe product can quickly extract total RNA from various cells or tissues, and can process 30-50 mg of tissue or 5 × 10 ⁶ cells each time,Can handle multiple different samples simultaneously. If it is an RNA experiment that is very sensitive to trace amounts of DNA, the residual DNA can be utilizedUsing DNase without RNase for digestion and removal on the column, the extracted RNA can be directly applied to RT-PCR Experiments such as Northern Blot, Dot Blot, and in vitro translation. U665516 Component 50 T Storage U665516A DNase I 1000 U -20℃. Avoid freeze/thaw cycle. U665516B 10×Reaction Buffer 1000 µL -20℃. Avoid freeze/thaw cycle. U665516C TRIzon Reagent 60 mL 2-8℃. Protect from light. U665516D TRIzon PaI™ 10 mL 2-8℃. Protect from light. U665516E Buffer RW1 40 mL RT U665516F Buffer RW2 (concentrate) 11 mL RT U665516G RNase-Free Water 10 mL RT U665516H Spin Columns RM with Collection Tubes 50 sets RT U665516I RNase-Free Centrifuge Tubes (1.5 mL) 50 EA RTPreparation and important precautions before the experiment:1.To prevent RNase pollution, attention should be paid to the following aspects:1) RNase's plastic products and gun heads to avoid cross contamination.2) Prepare the solution using water without RNase.3) Operators should wear disposable masks and gloves, and change gloves frequently during the experiment.2. The sample should avoid repeated freezing and thawing, otherwise it will affect the yield and quality of RNA extraction.3. If TRIzon Reagent is found to have precipitates before use, it can be dissolved in a water bath at 56 ℃ for a few minutes.Before the first use, anhydrous ethanol should be added to Buffer RW2 according to the instructions on the reagent bottle label.5. All centrifugation steps should be carried out at room temperature unless otherwise specified, and all operation steps should be carried out quickly.Usage:1. Sample processing1a. Organization: 30-50 mg of tissue is thoroughly ground in liquid nitrogen and 1 mL of TRIzon Reagent is added, or 1 mL of TRIzon Reagent is added to the tissue sample and homogenized. Attention: The sample volume should not exceed 10% of the volume of TRIzon Reagent.2a. Single layer cell culture: Remove the culture medium and add an appropriate amount every 10 cm ² Add 1 mL of TRIzon Reagent.3a. Cell suspension: Collect cells by centrifugation. Add 1 mL of TRIzon Reagent to every 5 × 10 µ m cell.2. After adding TRIzon Reagent, repeatedly blow a few times to fully crack the sample. Leave at room temperature for 5 minutes to completely separate the protein nucleic acid complex.3. Add 200 to every 1 mL of TRIzon Reagent µ LTRIzon PaI ™, Cover the tube tightly, vigorously shake for 15 seconds, and let it sit at room temperature for 2 minutes.4. Centrifuge at 4 ℃ 12000 rpm (~13400 × g) for 10 minutes. At this time, the sample is divided into three layers: the red organic phase, the middle layer, and the upper colorless aqueous phase. RNA is mainly in the upper aqueous phase. Move the upper aqueous phase to a new RNase Free centrifuge tube (provided).5. Add an equal volume of 70% ethanol (prepared without RNase water) to the obtained aqueous solution, invert and mix well.6. Add all the solutions obtained in the previous step to the spin columns RM that have been loaded into the collection tube. If the solution cannot be added at once, it can be transferred in multiple batches. Centrifuge at 12000 rpm for 20 seconds, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.7. Add 350 to the adsorption column µ L Buffer RW1, centrifuge at 12000 rpm for 20 seconds, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.8. Preparation of DNase I mixture: Take 52 µ LRNase Free Water, add 8 to it µ L 10 x Reaction Buffer and 20 µ L DNase I (1 U/ µ L) Mix well and prepare to a final volume of 80 µ The reaction solution of L.9. Directly add 80 µ L DNase I mixture to the adsorption column and incubate at 20-30 ℃ for 15 minutes.10. Add 350 to the adsorption column µ L Buffer RW1, centrifuge at 12000 rpm for 1 minute, discard the waste liquid, and place the adsorption column back into the recovery manifold.11. Add 500 to the adsorption column µ L Buffer RW2 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 20 seconds, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.12. Repeat step 11.Centrifuge at 12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes and thoroughly air dry. Attention: The purpose of this step is to remove residual ethanol from the adsorption column, which will affect subsequent enzymatic reactions (enzyme digestion,. )PCR, etc.14. Place the adsorption column in a new RNase free centrifuge tube and add 30-50 to the middle of the adsorption column µ Place RNase Free Water at room temperature for 1 minute, centrifuge at 12000 rpm for 1 minute, collect RNA solution, and store RNA at -70 ℃ to prevent degradation.Attention:1) The volume of RNase Free Water should not be less than 30 µ L. Small volume affects the recovery rate.2) If you want to increase RNA production, you can use 30-50 µ Repeat step 14 for the new RNase Free Water.3) If you want to increase the RNA concentration, you can add the obtained solution back to the adsorption column and repeat step 14... Read More |