| Description | Inquire | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export | DescriptionGreen LED Array for Photo KitAlysis high-throughput screening platform. For use with Photo KitAlysis Starter Kit (Z742612). User guide is provided in the below hyperlink.Photo KitAlysis Operating InstructionsFeatures:Designed and tested by synthetic chemists.Controller provides repeatableDescriptionGreen LED Array for Photo KitAlysis high-throughput screening platform. For use with Photo KitAlysis Starter Kit (Z742612). User guide is provided in the below hyperlink.Photo KitAlysis Operating InstructionsFeatures:Designed and tested by synthetic chemists.Controller provides repeatable milliamp selection for photon intensity (sold seperately)527 nm wavelength0-30 mA variable LED outputNon-magnetic LED baseChemically resistant LED coverPTFE coated cablingPhoto Kitalysis Starter Kitrequired for operation (sold separately). Best when used withKitAlysis Benchtop Inertion Box(sold separately)... Read More | Product introduction:PMA qPCR live bacteria detection kit provides an effective means to detect bacterial activity. This kit provides a mixture of PMA dye and SYBR green dye based qPCR. The optimal amount of dye and the number of samples that can be processed may vary depending on the type ofProduct introduction:PMA qPCR live bacteria detection kit provides an effective means to detect bacterial activity. This kit provides a mixture of PMA dye and SYBR green dye based qPCR. The optimal amount of dye and the number of samples that can be processed may vary depending on the type of sample. PMA is a DNA binding dye with high affinity, especially with double stranded DNA. The dye itself has weak fluorescence, but it can emit brighter fluorescence after binding with nucleic acids. PMA is impermeable to the cell membrane, so it can selectively modify the DNA of dead cells with damaged membrane. After bllight (~464 nm) photolysis of PMA modified DNA, the photoreactive azido group on PMA is converted into highly reactive azene radical, which reacts with any hydrocarbon moiety near the DNA binding site to form a stable covalent nitrogen carbon bond, resulting in permanent DNA modification. This modification process will make the DNA insoluble, and it will be lost together with cell debris in the later genomic DNA extraction process. The unbound PMA remaining in the solution reacts with water molecules under strong light irradiation and decomposes into hydroxylamine compounds without cross-linking activity, so that it can no longer covalently bind DNA. Based on this characteristic of PMA, our company combines PMA and qPCR technology to form a new detection method - PMA qPCR, which is used for the screening of live bacteria. At present, the method has been validated in a variety of bacterial strains as well as yeast, fungi, viruses and parasites. The treatment of complex samples, such as feces or soil, may require optimization of sample dilution, dye concentration, and light treatment time. Treatment of diluted samples, such as water testing, may require filtration or concentration prior to dye treatment. Component: Instruction: Precautions before use:1.This live bacteria detection kit distinguishes dead bacteria and live bacteria according to cell membrane permeability. Many methods of killing bacteria cause damage to the cell membrane and are therefore compatible with this kit. But some methods, such as ultraviolet irradiation, may not immediately cause cell membrane rupture. Therefore, before selecting this kit, it is necessary to carry out literature search and pre-experiment to determine whether the kit is suitable for the bacterial type and killing method you choose. 2.After PMA treatment, the bacteria need to be photolyzed to covalently bind the dye to dead cell DNA. Photolysis operations can use blue or white light sources. Generally speaking, the brighter the lamp, the higher the efficiency of the photolysis step. Non-LED lamps ( such as halogen lamps ) may heat your sample and have a negative impact on the analysis. Ice is required to cool the sample during irradiation. 3.Sample can be cryopreservation after photolysis. Frozen samples before PMA treatment photolysis may damage the cell membrane and produce false negative results. If the sample needs to be frozen before detection, it is recommended to perform a pre-experiment first. 4.Part of the mechanism of PMA is to remove PMA covalently modified DNA from the sample by precipitation ; therefore, when extracting genomic DNA, it is necessary to use the same volume of genomic DNA eluent for volume normalization. The positive control can use the genomic DNA of living cells. 5.In order to verify the effectiveness of PMA in the test sample, the Ct ( dCt ) changes between- / + PMA can be compared. Experimental materials ( self-provided ):①Light source ( used for the photolysis step after PMA modified DNA ) ;② Bacterial genomic DNA extraction kit ; Experimental procedure: 1.Suck 10 µL of E.coli bacterial solution in liquid LB medium, and culture E.coli in the bacterial incubator overnight or longer to the logarithmic growth phase ( OD600 ≈ 1.0 ) ; Note : The culture time is adjusted according to the experiment. 2.Two portions of live E.coli, 400 µL each, were placed in a clean centrifuge tube ; 3. ( Recommended ) Preparation of dead E.coli. If the dead E.coli is needed as a control, the dead E.coli can be obtained by heating the living E.coli in a water bath at 95 °C for 5 min, or at 58 °C for 3 h. the subsequent operation of the dead E. coli is the same as that of the living E. coli ; 4.Two copies of live E.coli, one without PMA treatment, and one with 25 µM PMA treatment ( the optimal PMA concentration for treating different types or different sources of bacteria needs to be consulted in the relevant literature ) ; 5.The PMA-treated samples were placed on a shaker at room temperature and incubated in the dark for 10 min to fully mix the dye with the sample ; 6.Exposure of the sample, you can use blue or white light source, irradiation time to explore their own. For example, a 60 W blue light can be used for 15 min. Note : 1 If a halogen lamp is used, we recommend that the PMA-treated sample tube be placed on an ice block 20 cm away from the light source. Ice should be placed in a transparent tray. Adjust the light source to point directly to the sample, photolysis for 5-15 min ; if the bacteria obtained from the environment are directly used for experiments, due to the complexity or turbidity of the environmental samples, the photolysis time needs to be prolonged appropriately. 7.Treated and untreated live E.coli 5000 × g, centrifuged for 10 min, remove the supernatant ; 8.Select the appropriate genomic DNA extraction kit according to the sample type, and use the same elution volume for each group of samples when elution DNA. Note : DNA extraction steps refer to the instructions of the kit used. Part of the mechanism of action of PMA is to remove PMA-bound DNA from the sample by precipitation ; therefore, when extracting genomic DNA, each group should use the same volume of genomic DNA eluent for volume normalization ( the amount of genomic DNA extracted from dead bacteria and live bacteria is inconsistent, so the concentration of the two is significantly different ). 9.Preparation of reaction mixture according to the following system : Note : 1 For the DNA extracted by commercial DNA extraction kit, the qPCR template was optimized with 2 µL as the initial volume ; 2 The template volume should not exceed 10 % of the final reaction volume ; 3 Template concentration : gDNA as template, usually 1-10 ng ; the final concentration of PCR primers is usually 0.4µM, which can get better results. When the reaction performance is poor, the primer concentration can be adjusted in the range of 0.2-1µM. 10.Slightly vortex the reaction mixture, transfer the fixed volume to the PCR tube. 11. Test procedureNote : 1 The extension time is adjusted according to the instrument ; the Taq enzyme in mix can be activated within 2 min, but the genomic DNA may require longer denaturation time, which can be increased at this time, and the specific denaturation time can be adjusted according to the sample type. 12. ( Optional ) Data analysis Using live bacteria and dead bacteria as controls, the number of live cells in the sample was analyzed and calculated. It is recommended to verify the suitability of primers and PCR procedures before starting PMA qPCR detection of live bacteria. Calculation of dead and living bacteria control dCt ( 1 ) After the end of qPCR, the Ct value of each sample was calculated by instrument software ; ( 2 ) By calculating the dCt of each control bacteria, it was judged whether PMA successfully inhibited the amplification of dead bacterial DNA. The calculation is as follows : dCt live = Ct ( live, PMA treated ) -Ct ( live, PMA untreated ) dCt die = Ct ( die, PMA treated ) -Ct ( die, PMA untreated ) ( 3 ) The dCt expectation of living bacteria is close to 0 ± 1, which indicates that PMA does not affect the amplification of living cell DNA ; ( 4 ) The expected value of dCt of dead bacteria is greater than 4 ( dCt is 4 means that it is reduced by about 16 times, that is, 94 % of dead bacterial DNA is removed ; a dCt of 8 indicated a decrease of about 250 times, that is, 99.6 % of the dead bacterial DNA was removed ).( 5 ) The dCt of dead bacteria depends on many factors, including : strain / cell type ; the way bacteria are killed ; the concentration of PMA used ; amplified sequence length. 3. Calculation of the proportion of viable ( optional ) bacteria If the control results of dead and live bacteria are normal, the proportion of live bacteria in the sample can be calculated.( 1 ) Calculate the dCt value of the sample : dCt sample = Ct ( sample, PMA treated ) -Ct ( sample, PMA untreated ) ( 2 ) Conversion of dCt value to live bacteria ratio : PMA inhibition multiple = 2 ( sample dCt ) Viable bacteria % = 100 / PMA inhibition multiple 14. ( Optional ) Calculate the absolute number of live bacteria If you want to calculate the absolute number of viable bacteria in the sample, you need to use a known number of target bacteria genomic DNA to make a standard curve. It is recommended that the diluted concentrations of several groups of genomes are within the range of the qPCR analysis system. ( 1 ) qPCR was performed with the appropriate genome, and the Ct value was used as the ordinate, and the number of cells was used as the abscissa. The R2 value is calculated to determine the linearity, and the slope and y-axis intercept are displayed.( 2 ) Calculate the copy number of the experimental samples : Ct = slope * cell number + y axis intercept ( y = mx + b ) Bacterial count sample = ( Ct-y axis intercept ) / slope Note : The live bacterial DNA was not lost during the purification process. Examples : Product parameters:Pma: ex = 464 nm; Ex/em = 510/610 nm (following photolysis and reaction with dna/rna)Scope of application:Live bacteria detection Matters needing attention:1.Please instantaneously centrifuge the product to the bottom of the tube before use, and then carry out subsequent experiments ; 2.the kit components contain fluorescent dyes, and attention should be paid to avoiding light during use and preservation ; 3.For your safety and health, please wear experimental clothes and disposable gloves... Read More | V669947 Component 50T Storage V669947A Buffer GL 15 mL RT V669947B Buffer GW1 (concentrate) 13 mL RT V669947C Buffer GW2 (concentrate) 15 mL RT V669947D Buffer RE 10 mL RT V669947E Proteinase K 12.5 mg RT V669947F Proteinase K Storage Buffer 1.25 mL RT V669947G Spin Columns RS with Collection Tubes V669947 Component 50T Storage V669947A Buffer GL 15 mL RT V669947B Buffer GW1 (concentrate) 13 mL RT V669947C Buffer GW2 (concentrate) 15 mL RT V669947D Buffer RE 10 mL RT V669947E Proteinase K 12.5 mg RT V669947F Proteinase K Storage Buffer 1.25 mL RT V669947G Spin Columns RS with Collection Tubes 50 RT V669947H RNase-Free Centrifuge Tubes (1.5 mL) 50 RTProductsThis kit is suitable for the extraction of viral RNA and DNA from fresh or frozen plasma, serum and cell-free body fluids. It is easy to operate as it does not require the use of organic solvents such as phenol and chloroform for extraction. The kit uses a unique buffer system to enable efficient and specific binding of viral nucleic acids in lysate to silica gel centrifugal adsorption columns. Inhibitors of PCR and enzyme reactions as well as residual impurities can be efficiently removed in a two-step effective rinsing step, and finally high purity viral nucleic acids can be obtained by using a low-salt buffer or water for elution. The purified viral nucleic acid is free of protein, nuclease and other impurities, and can be used directly in PCR, RT-PCR, Real-Time PCR, blotting experiments and so on.Self-contained reagent: anhydrous ethanol.Pre-experiment and Important Notes1. Add 1.25ml Proteinase K Storage Buffer to Proteinase K to dissolve it and store it at -20℃. Do not leave the prepared Proteinase K at room temperature for a long time, and avoid repeated freezing and thawing to avoid affecting its activity. Do not add Proteinase K directly into Buffer GL.2. Repeated freezing and thawing of the sample should be avoided, as this may result in smaller DNA fragments and a decrease in the amount of extracted DNA.3. Avoid repeated freezing and thawing of serum or plasma, which can lead to protein denaturation or precipitation, reducing the viral titer and thus affecting the yield of extracted viral nucleic acids.4. Anhydrous ethanol should be added to Buffer GW1 and Buffer GW2 according to the label instructions of the reagent bottle before first use.5. Check Buffer GL for crystallization or precipitation before use. If crystallization or precipitation occurs, redissolve Buffer GL in a water bath at 56℃.Procedure1. Take a 1.5 ml centrifuge tube (self-provided) and add 20 µl Proteinase K.2. Add 200 µl serum or plasma to the centrifuge tube. Add 200µl Buffer GL and vortex and shake for 15 seconds.Note: 1) Sample volume less than 200 µl can be made up by adding 0.9% NaCl (self-provided). 2) In order to ensure effective lysis of the sample, the sample needs to be mixed well with Buffer GL after adding Buffer GL.3. Incubate at 56°C for 15 minutes, centrifuge briefly, and collect the solution from the wall of the tube to the bottom of the tube.4. 250 µl of anhydrous ethanol was added, vortexed and shaken for 15 seconds, left at room temperature for 5 minutes, centrifuged briefly, and the solution on the wall of the tube was collected at the bottom of the tube.Note: If the ambient temperature exceeds 25°C, anhydrous ethanol should be used after pre-cooling on ice.5. Add the solution obtained in step 4 to the adsorbent column (RNase-Free Columns RS) that has been loaded into the collection tube, and if the solution cannot be added at one time, it can be transferred in several times. centrifuge the column at 12,000 rpm (~13,400 × g) for 1 min, pour off the waste liquid in the collection tube, and put the column back into the collection tube.6. Add 500 µl of Buffer GW1 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorption column back into the collection tube.7. Add 500 µl of Buffer GW2 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorption column back into the collection tube.Note: Step 7 can be repeated if further DNA purity is required.8. Add 500 µl of anhydrous ethanol to the adsorbent column and centrifuge at 12,000 rpm for 1 min. Pour off the waste liquid in the collection tube and put the adsorbent column back into the collection tube.9. Centrifuge at 12,000 rpm for 3 minutes and pour off the waste liquid in the collection tube. Leave the adsorption column at room temperature for several minutes to dry thoroughly.Note: The purpose of this step is the removal of residual ethanol from the adsorbent column; ethanol residue can interfere with subsequent enzymatic reactions (digestion, PCR, etc.).10. Place the adsorption column in a new collection tube (RNase-Free Centrifuge Tube), add 20-150 µl of Buffer RE or sterilized water overhanging the middle of the adsorption column membrane, leave it at room temperature for 2-5 minutes, and then centrifuge it at 12,000 rpm for 1 minute to collect the nucleic acid solution.Note: 1) If the downstream experiment is sensitive to pH or EDTA, you can use sterilized water for elution. The pH of the eluent has a great influence on the elution efficiency, if water is used as the eluent it should be ensured that its pH is 7.0-8.5 (the pH of water can be adjusted to this range with NaOH), and the elution efficiency is not high when the pH is lower than 7.0.(2) For long-term storage, please store the DNA solution at -20℃ and the RNA solution at -70℃.3) If the final concentration of DNA/RNA is to be increased, the DNA/RNA eluate obtained in step 10 can be re-spiked onto the adsorbent membrane and step 10 repeated... Read More |