| Description | Inquire | Format:2-ComponentEnzyme:Horseradish peroxidase | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export | N665917 Component 1 mL 5 mL Storage N665917A 2×SYBR qPCR MasterMix 1 mL 5×1 mL -20℃. Avoid freeze/ Thaw cycle. N665917B qPCR Primer Mix 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917C DNA Standard A 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917 Component 1 mL 5 mL Storage N665917A 2×SYBR qPCR MasterMix 1 mL 5×1 mL -20℃. Avoid freeze/ Thaw cycle. N665917B qPCR Primer Mix 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917C DNA Standard A 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917D DNA Standard B 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917E DNA Standard C 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917F DNA Standard D 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917G DNA Standard E 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917H 50×High ROX 40 µL 200 µL -20℃. Avoid freeze/ Thaw cycle.Product IntroductionThis is a dye-based (SYBR Green I) qPCR NGS library quantification kit for cfDNA, which provides the reaction mixture, DNA primer mixture, standards, and sample dilutions required for the qPCR process, making it a complete reagent system that is easy and convenient to use. The fluorescent dye SYBR Green I contained in the reaction mixture binds to all double-stranded DNA. The kit uses a new chemically modified high-efficiency hot-start polymerase, the activation of the enzyme needs to be incubated at 95 ℃ for 10 min. the product is highly specific, high amplification efficiency, the length of the standard in the kit (about 270bp) is comparable to the average length of the cfDNA NGS libraries (250-300bp), which is able to quickly and accurately quantitate the concentration of the constructed cfDNA libraries. quantification.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used in Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument.Instruments that do not require ROX calibration: Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96, etc.Instruments requiring Low ROX calibration: ABI Prism7500/7500 Fast, QuantStudio®3 System, QuantStudio®5 System, QuantStudio®6 Flex System, QuantStudio®7 Flex System, ViiA7 System, Stratagene Mx3000/Mx3005P, Corbett Rotor Gene 3000, and others.Instruments requiring High ROX calibration: ABI Prism7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, etc.NOTE: High Rox and Low Rox are formulated as described in Method of Use 2.Applicable scopeThis product is designed for the absolute quantification of the concentration of Illumina platform second generation sequencing libraries. The end of the library contains Illumina P5 and P7 microarray binding sequences, the length of which does not exceed 1kb, and the concentration is not less than 0.02pM can be used for quantitative experiments. The qPCR Primer Mix provided in the kit contains the following two primer sequences:Primer 1:5'-AAT GAT ACG GCG ACC ACC GA-3' Primer 2: 5'-CAA GCA GAA GAC GGC ATA CGA-3'The primer sequence can be used in advance to confirm whether the library can be amplified by that primer pair.UsageAmplification template preparationThe library samples to be detected were diluted with TE (10 mM Tris-Cl, pH 8.0, 1 mM EDTA), and the concentration after dilution was as close as possible to the range of 0.01-60 pM. 4°C on ice was set aside.qPCR reaction system preparationThe desired cryopreservation reagent is pre-melted completely and mixed by inverting several times before preparation, then centrifuged briefly and set aside.The base reaction system for 20 µl was as follows:Reagent20 µl Reaction system2×SYBR qPCR MasterMix10 µlqPCR Primer Mix0.8 µlTemplate4 µlddH₂O5.2 µlDescription: High Rox model: 1 µl High Rox per 50 µl of reaction system; Low Rox model: 1 µl High Rox per 500 µl of reaction system.Prepare a sufficient amount of reaction system mixture according to the need, mix well and add to the reaction wells in a volume of 16 µl per well, add the same volume of TE to the blank control, and then add the prepared standards and diluted samples to the corresponding reaction wells in a volume of 4 µl/well. It is recommended to use 20 µl reaction system, if you need to carry out a smaller system reaction, the system components can be reduced in equal proportion.3.qPCR reaction programIf the average length of the library is greater than 700bp, the annealing/extension time should be increased appropriately.Refer to the specific instrument setup program for dissolution curves.data analysisStandard curve productionThe standard curve was plotted according to the data processing Excel sheet. The correlation coefficient R2 of the standard curve should be not less than 0.99, and the slope should be located between -3.1 and -3.6 when the Ct value is the longitudinal coordinate. If the parameters of the standard curve are unreasonable, it is recommended to repeat the experiment.DNA Standard NameDNA Standard ConcentrationDNA Standard A60 pMDNA Standard B6 pMDNA Standard C0.6 pMDNA Standard D0.06 pMDNA Standard E0.006 pMLibrary Concentration CalculationsThe difference in Ct between the three replicate wells of the experiment should be no more than 0.2, otherwise the invalid data should be deleted or the experiment should be repeated. Do not use the Ct outside the valid Ct range of the standard curve to calculate the concentration of the diluted libraries. Please refer to the data processing Excel of this product for the specific library concentration calculation method.matters needing attentionThese instructions should be read in detail before testing. It should be carried out by personnel with specialized experience or qualified by training.Mix gently by turning up and down, avoid foaming as much as possible, and centrifuge for a short time before use.Avoid repeated freezing and thawing of this product; repeated freezing and thawing may degrade product performance.When preparing reaction solutions, use new or non-contaminated tips and centrifuge tubes to prevent contamination as much as possible... Read More | This reagent kit uses highly sensitive silver dye, which can be applied to protein staining of denatured and non denatured gels. It has the advantages of clear target bands, low background, and flexible control of operation time. In addition, this reagent kit has added a short-term sensitization This reagent kit uses highly sensitive silver dye, which can be applied to protein staining of denatured and non denatured gels. It has the advantages of clear target bands, low background, and flexible control of operation time. In addition, this reagent kit has added a short-term sensitization step, which can significantly reduce the background and enhance the brightness of the target band. P665901Component20 TStorageP665901ASilver Stain Sensitizer (500×)2×1 mLRTP665901BSilver Stain Enhancer3 mLRTP665901CSilver Stain2×250 mLRTP665901DSilver Stain Developer4×125 mLRT Matters needing attention1. Please prepare 50 ml of fixed solution (ultrapure water: ethanol: acetic acid=6:3:1), 50 ml of eluent (10% ethanol), and 50 ml of termination solution (5% acetic acid) in advance.2. Please use deionized water and clean glass or plastic containers during operation, and wear disposable gloves for operation.The entire silver dyeing process needs to be carried out on a shaker, with a rotation speed of about 60 rpm.4. Self prepared ethanol and glacial acetic acid are required.Instructions for useThe dosage of each solution in the following operation steps takes the gel with a size of 8.5 × 5.5 cm and a thickness of 1.0 mm as an example. The gel is immersed in the solution completely, and is operated on a shaker, with a general dosage of 25 ml. For large gel, the dosage of each solution should be scaled up according to the gel volume. Please prepare 50 ml of fixed solution (ultrapure water: ethanol: glacial acetic acid=6:3:1), 50 ml of eluent (10% ethanol), and 50 ml of termination solution (5% glacial acetic acid) in advance.1. Water washing: After electrophoresis is completed, wash the gel twice with ultrapure water for 5 minutes each time.2. Fixation: Fix the gel twice with 25 ml of fixative solution for 15 minutes each time.3. Elution: Wash the adhesive twice with eluent, each time for 5 minutes.4. Water washing: Wash the glue twice with ultrapure water, each time for 5 minutes.5. Sensitization: put the gel washed in the previous step into the silver dye sensitization working solution, incubate it accurately for 1 minute at room temperature, and then wash it with ultrapure water for three times, each time for 20 seconds. Preparation of silver staining sensitization working solution: Take 50 µ l Silver Stain Sensitivity (500 x) and add it to 25 ml of ultrapure water, mix well.6. Silver staining: discard ultrapure water and incubate gel in silver staining working solution for 30 minutes. Preparation of silver staining working solution: Take 25ml Silver Stain and add 50 µ l Silver Stain Enhanced to mix well.7. Water washing: Quickly wash the glue twice with ultrapure water, with each washing accurately controlled for 20 seconds.8. Development: Immerse the washed gel in the developer immediately and incubate it at room temperature for 2-3 minutes until the protein strip is clear. Preparation of developer: Take 25ml Silver Stain Developer and add 30 µ l Silver Stain Enhanced to mix well. Attention: Within 30 seconds of development, protein bands begin to appear and continue to develop for 2-3 minutes. If the protein band appears lighter, the development time can be appropriately extended to 5 minutes or more.9. Termination: After washing the developer on the gel with the termination solution, soak the gel in a new termination solution to react for 10 minutes.Experimental imagesSilver staining results of BSA protein samples after 10% SDS-PAGE gel electrophoresisThe molecular weight of BSA protein is about 66 kD, and the loading amounts from left to right are 50 ng, 10 ng, and 5 ng, respectively... Read More |