| Description | Inquire | B665530 Component 50 T 200 T Storage B665530A Buffer RCL 125 mL 2×260 mL 2-8℃ B665530B Buffer GR 15 mL 50 mL RT B665530C Buffer GL 15 mL 50 mL RT B665530D Buffer GW1 (concentrate) 13 mL 52 mL RT B665530E Buffer GW2 (concentrate) 15 mL 50 mL RT B665530F Buffer GE 15 mL 60 mL RT B665530G B665530 Component 50 T 200 T Storage B665530A Buffer RCL 125 mL 2×260 mL 2-8℃ B665530B Buffer GR 15 mL 50 mL RT B665530C Buffer GL 15 mL 50 mL RT B665530D Buffer GW1 (concentrate) 13 mL 52 mL RT B665530E Buffer GW2 (concentrate) 15 mL 50 mL RT B665530F Buffer GE 15 mL 60 mL RT B665530G Proteinase K 1.25 mL 4×1.25 mL RT B665530H Spin Columns DM with Collection Tubes 50 sets 200 sets RTProduct IntroductionThis reagent kit is suitable for extracting total DNA, including genomic DNA, mitochondrial DNA, and viral DNA, from fresh or frozen whole blood (blood samples treated with anticoagulants such as citrate, EDTA, or heparin), plasma, serum, erythrocyte sedimentation rate brown layer, lymphocytes, cell-free body fluids, and other samples. This product can process 0.1-1 mL of whole blood with a maximum yield of 30% µ g. It can purify DNA with sizes ranging from 100 bp to 50 kb. The purified DNA has high yield and good quality, and can remove protein, pigment, lipid, and other inhibitory impurities to the maximum extent. It can be directly used for PCR, fluorescence quantitative PCR, enzyme digestion, and Southern Blot experiments.Self prepared reagent: anhydrous ethanol.Preparation and important precautions before the experiment:1. The sample should avoid repeated freeze-thaw cycles, otherwise it may result in smaller extracted DNA fragments and a decrease in extraction volume.2. This reagent kit can extract up to 0.1-1 mL of whole blood samples or 1 × 107 white blood cells.3.Before the first use, anhydrous ethanol should be added to Buffer GW1 and Buffer GW2 according to the instructions on the reagent bottle label.4. Before use, please check if there is any crystallization or precipitation in the Buffer GL. If there is any crystallization or precipitation, please incubate the Buffer GL in a 56 ℃ water bath and dissolve it again.5. The Buffer RCL in the reagent kit cannot be used again after being turbid.Operation steps:1. Sample processing: 1a When extracting 200 uL of blood sample, add the sample to the centrifuge tube (provided) and proceed directly to the next step of the experiment. 1b When the blood sample size is less than 200 µ When L, add Buffer GR to make up for 200 µ L. Proceed to the next step of the experiment. 1c When the blood sample size exceeds 200 µ When L is reached, add 1-2 times the volume of Buffer RCL, gently vortex or invert and mix well. Centrifuge at 12000 rpm (~13400 × g) for 1 minute and carefully discard the supernatant. If there is still red in the sediment, repeat the above steps once. Then add 200 to the precipitate µ Shake the buffer GR until thoroughly mixed before proceeding to the next step of the experiment. 1d If the processed blood sample is anticoagulant from poultry, birds, amphibians, or lower level organisms, its red blood cells are nucleated cells, and the blood sample size is 5-20 µ L. Can be added to Buffer GR to make up to 200 µ Follow up experiments will be conducted afterwards. Note: If downstream experiments are sensitive to RNA, 4 can be added µ L RNase A (100mg/mL) solution, shake for 15 seconds, and leave at room temperature for 5 minutes. RNase A reagent kit is not provided. If needed, you can order it separately from our company, item number: CW0601S.2. Add 20 to the above solution µ L Protein K, mix well.3. Add 200 µ Shake with L Buffer GL until thoroughly mixed. Note: Do not pre mix Protein K and Buffer GL.4.Incubate at 4.56 ℃ for 10 minutes, invert and mix several times during this time. Attention: The DNA production has reached its maximum after 10 minutes of incubation, and further extension of incubation time has no effect on DNA production and purity.5. Add 200 µ L anhydrous ethanol, invert and mix several times. Short centrifugation causes the liquid on the tube wall and wall cover to concentrate at the bottom of the tube.6. Add all the solution obtained in step 5 to the spin columns DM that have been loaded into the collection tube. If the solution cannot be added at once, it can be transferred multiple times. Centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.7. Add 500 to the adsorption column µ L Buffer GW1 (check if anhydrous ethanol is added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube. Note: If the extracted sample is the blood genome of species such as mice or monkeys that are difficult to remove heme, it is recommended to repeat step 7.8. Add 500 to the adsorption column µ L Buffer GW2 (check if anhydrous ethanol is added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube. Note: To further improve DNA purity, repeat step 8.9.Centrifuge at 9.12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry. Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.)10. Place the adsorption column in a new centrifuge tube (provided by oneself) and add 50-200 to the middle of the adsorption column in the air µ L Buffer GE or sterilized water, leave at room temperature for 2-5 minutes, centrifuge at 12000 rpm for 1 minute, collect DNA solution, and store DNA at -20 ℃. Note: 1) If downstream experiments are sensitive to pH or EDTA, they can be washed off with sterilized water. The pH value of the eluent has a significant impact on the elution efficiency. If water is used as the eluent, its pH value should be ensured to be between 7.0-8.5 (NaOH can be used to adjust the pH value of the water to this range). When the pH value is below 7.0, the elution efficiency is not high. 2) If the final concentration of DNA needs to be increased, the obtained DNA eluent can be added back to the adsorption membrane, left at room temperature for 2-5 minutes, and centrifuged at 12000 rpm for 1 minute. 3) Because DNA stored in water is affected by acidic hydrolysis, if long-term storage is required, it is recommended to elute with Buffer GE and store at -20 ℃... Read More | DescriptionUse in combination with the KitAlysis Bench Top Inertion Box (Z742064) or a glove box/glove bag to provide inert atmosphere for kit set-up.Designed to be used with KitAlysis High-Throughput Screening Kits.Components:24-Well Reaction BlockTorque ScrewdriverSmall screwdriver to easily DescriptionUse in combination with the KitAlysis Bench Top Inertion Box (Z742064) or a glove box/glove bag to provide inert atmosphere for kit set-up.Designed to be used with KitAlysis High-Throughput Screening Kits.Components:24-Well Reaction BlockTorque ScrewdriverSmall screwdriver to easily remove torqued screws after reaction is complete.10 Reaction Block Replacement Screws... Read More | Products content Products IntroductionThis kit is a dedicated sample preparation solution for microbiome analysis and is suitable for the purification and enrichment of genomic DNA of pathogenic microorganisms such as bacteria and fungi from mixed samples such as swabs, blood, sputum, alveolar Products content Products IntroductionThis kit is a dedicated sample preparation solution for microbiome analysis and is suitable for the purification and enrichment of genomic DNA of pathogenic microorganisms such as bacteria and fungi from mixed samples such as swabs, blood, sputum, alveolar lavage, etc. During the purification process, differential lysis of the host cells and subsequent enzymatic digestion can effectively remove most of the host DNA while providing a comprehensive coverage of the bacterial and fungal DNA loci to a higher level. By differential lysis of host cells and subsequent enzymatic digestion, this kit can effectively remove most of the host DNA while maximizing the full coverage of bacterial, fungal and other pathogenic microbial DNA sites, thus obtaining microbiome DNA enrichment products with a higher coverage. Microbial DNA purified with this kit is suitable for a variety of downstream applications, including whole genome sequencing analysis, 16S rDNA-based high sensitivity microbiome analysis, and macrogenomic birdshot sequencing analysis. Self-contained reagents and consumablesSterile pipette tips with aerosol barrier to prevent cross-contamination anhydrous ethanol Microcentrifuge tubes (2 ml/1.5 ml) PBS buffer (required for some samples only)Pre-experiment Preparation and Important Notes1. Add 1.25 ml Proteinase K Storage Buffer to Proteinase K and store at -20℃. Do not leave the prepared Proteinase K (20 mg/ml) at room temperature for a long time, and avoid repeated freezing and thawing to avoid affecting its activity.2. Dissolve Lysozyme (100 mg) in 10 ml Enzymatic Lysis Buffer to a final concentration of 10 mg/ml, dispense into sterile tubes and store at -20℃. Do not leave the prepared Lysozyme (10 mg/ml) at room temperature for a long time and avoid repeated freezing and thawing to avoid affecting its activity.3. Thaw Buffer GB1 and Buffer GB2 at room temperature or 2-8°C before use and mix thoroughly. Thawed Buffer GB1 and Buffer GB2 can be left at 2-8°C for 1-2 weeks without affecting their activity, and should be stored at -20°C for long term storage. To ensure optimal performance, do not freeze or thaw more than three times. If less than one bottle of Buffer GB1 and Buffer GB2 is required for a single extraction, ensure that it is used under sterile conditions such as an ultra-clean bench and avoid microbial contamination and growth in the remaining buffer.4. Before first use, anhydrous ethanol should be added to Buffer GW1 and Buffer GW2 according to the instructions on the vial label and labeled.5. Check Buffer GL for crystallization or precipitation before use, and if crystallization or precipitation occurs, redissolve Buffer GL in a 56°C water bath.6. If the downstream experiments are sensitive to RNA contamination, 4 µl of DNase-Free RNase A (100 mg/ml) can be added before adding Buffer GL. RNase A is not provided in the kit, but can be ordered separately from CW0601S.7. This kit is designed for the isolation of DNA from intact microbial cells. To ensure optimal recovery of microbial DNA, samples should be fresh. If storage or transportation is required, this should preferably be done at 2-8°C and not frozen or thawed, as freezing and thawing can damage the integrity of the microbial cells and therefore result in the loss of exposed microbial DNA during host DNA removal.8. To avoid false results due to contamination, keep the work area clean, wear protective clothing, and set up controls for quality control. Use appropriate measures to handle sample materials to minimize the risk of cross-contamination. During the extraction process, use DNA-free pipette tips and consumables, and cap reagents immediately after use to prevent contamination. procedure1. Sample pre-treatment: 1a: For swab samples, swirl the swab portion of the swab in 0.5 ml PBS for at least 20 s. Squeeze the swab several times against the wall of the tube before removing it so that as much of the bacterial fluid as possible can be squeezed out of the swab to minimize sample loss. 1b: For viscous samples, e.g. sputum, take ~500 µl of sample, add 1.5 times the volume (~750 µl) of Buffer GB1 and incubate at 37°C, 600 rpm for 15-30 min until the sample is completely liquefied.Note: The sample volume can be increased or decreased appropriately and the amount of Buffer GB1 added adjusted accordingly.1c: For alveolar lavage fluid containing a small amount of viscous sputum, centrifuge as much of the alveolar lavage fluid as possible, carefully remove the supernatant, and retain the lower viscous fraction (containing sputum, cells, and organisms), add 1.5 times the volume of Buffer GB1, and incubate for 15-30 min at 37°C, 600 rpm until the sample is completely liquefied.1d: For non-viscous body fluid samples such as blood and cerebrospinal fluid, liquefaction treatment is not required, and an appropriate amount of sample is taken directly, the operation of step 2 is carried out, and the cell precipitate is collected by centrifugation.2. Centrifuge at 10000 rpm for 5-10 min at room temperature and carefully discard the supernatant.Note: Do not disturb the lower cell sediment to avoid sample loss.3. Add 500 µl Buffer GB2, vortex to mix, and incubate at room temperature, 600 rpm for 10 min. 4. Centrifuge at 12000 rpm for 2 min and carefully remove the supernatant.Note: Do not disturb the bacterial precipitate when removing the supernatant to avoid sample loss.5. Add 200 µl of Buffer GB2 to the precipitate, add 2 µl of Benzonase and incubate for 30 min at 37°C, 600 rpm. 6. Centrifuge at 12000 rpm for 2 min, discard the supernatant, add 500 µl of Buffer GB2, vortex and wash the precipitate. Repeat the procedure once.7. Centrifuge at 12000 rpm for 2 min, discard the supernatant, and finally aspirate the residual Buffer GB2 with a small-volume tip. 8. Add 180 µl Lysozyme (10 mg/ml), resuspend the bacterial precipitate and transfer the bacterial resuspension to a Lysis Tube.9. The Lysis Tube is incubated at 37°C, 600 rpm for 20-30 min, then vortexed for 10 min or processed on a thermostatic homogenizer for 10 min at maximum vibration speed (2500-2900 rpm).10. Centrifuge briefly, add 20 µl proteinase K, vortex to mix, add 200 µl buffer GL, vortex to mix, and incubate for 30 min at 56°C, 600 rpm. Note: 1) Do not add Proteinase K directly to Buffer GL.2)For RNA removal, add 4 µl DNase-Free RNase A (100 mg/ml) before adding Buffer GL, shake to mix, and let stand at room temperature for 5-10 minutes.11. Centrifuge at 12000 rpm for 1 min and carefully aspirate the supernatant into a new centrifuge tube. Note: Do not aspirate the glass beads.12. Add 200 µl of anhydrous ethanol, vortex to mix, and centrifuge momentarily to collect the solution to the bottom of the tube. Note: The addition of anhydrous ethanol may produce a white precipitate that will not affect subsequent experiments.13. Add all of the solution from step 12, including the precipitate, to the Spin Columns DM in the collection tube, or transfer the solution several times if it cannot be added all at once. centrifuge at 12,000 rpm for 1 minute, pour off the waste from the collection tube, and return the column to the collection tube.14. Add 500 µl Buffer GW1 to the adsorbent column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 min, pour off the waste liquid from the collection tube, and put the adsorbent column back into the collection tube.15. Add 500 µl Buffer GW2 to the adsorbent column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorbent column back into the collection tube. Note: Step 15 can be repeated once if further improvement of DNA purity is required.16. Centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Leave the column at room temperature for a few minutes and dry thoroughly. Note: The purpose of this step is to remove residual ethanol from the adsorbent column; ethanol residue can interfere with subsequent enzymatic reactions (digestion, PCR, etc.).17. Place the adsorbent column in a new centrifuge tube (supplied), add 50 µl of Buffer GE to the center of the adsorbent column overhang, let stand at room temperature for 5 minutes, centrifuge at 12,000 rpm for 1 minute, collect the DNA solution, and store the DNA at -20 °C. Attention:1)If the downstream experiments are sensitive to pH or EDTA, sterilized water can be used for elution. The pH value of the eluent has a great influence on the elution efficiency. If the eluent is made of water, the pH value should be 7.0-8.5 (the pH value of water can be adjusted to this range with NaOH), and the elution efficiency is not high when the pH value is lower than 7.0.2)Incubation at room temperature for 5 minutes prior to centrifugation increases yield.3)If the final concentration of DNA is to be increased, the DNA eluate obtained in step 17 can be re-spiked onto the adsorbent membrane and step 17 repeated. 4)DNA stored in water will be affected by acidic hydrolysis. For long-term storage, it is recommended to elute with Buffer GE and store at -20℃... Read More | The Succinic Acid (Succinate) assay kit is suitable for the specific assay of succinic acid in wine, cheese, eggs, sauce and other food products. Succinic acid (or succinate) is found in all plant and animal materials as a result of the central metabolic role played by this dicarboxylic acid in the The Succinic Acid (Succinate) assay kit is suitable for the specific assay of succinic acid in wine, cheese, eggs, sauce and other food products. Succinic acid (or succinate) is found in all plant and animal materials as a result of the central metabolic role played by this dicarboxylic acid in the Citric Acid Cycle. Succinic acid concentrations are monitored in the manufacture of numerous foodstuffs and beverages, including wine, soy sauce, soy bean flour, fruit juice and dairy products (e.g. cheese).Product Description: Succinic acid is found in all plant and animal materials as a result of the central metabolic role played by this dicarboxylic acid in the Citric Acid Cycle. Succinic acid concentrations are monitored in the manufacture of numerous foodstuffs and beverages, including wine, soy sauce, soy bean flour, fruit juice and dairy products (e.g. cheese). The ripening process of apples can be followed by monitoring the falling levels of succinic acid. The occurrence of > 5 mg/kg of this acid in egg and egg products is indicative of microbial contamination. Apart from use as a flavouring agent in the food and beverage industries, succinic acid finds many other non-food applications, such as in the production of dyes, drugs, perfumes, lacquers, photographic chemicals and coolants. Preparation Instructions:Suitable for succinate determination in food, beverage, agricultural products, and other biological samples.Note for Content:The number of manual tests per kit can be doubled if all volumes are halved. This can be readily accommodated using the MegaQuantTM Wave Spectrophotometer (D-MQWAVE).Browse all of our organic acid assay kits.Principle:The Succinate Assay Kit provides a simple, one step assay for measuring succinate. In this assay succinate is converted to pyruvate which reacts with specific reagents and dye to form a colored product. The color intensity at 570 nm or fluorescencAdvantages:Extended cofactors stability. Dissolved cofactors stable for > 1 year at 4oC.Very competitive price (cost per test)All reagents stable for > 2 years as suppliedVery rapid reaction (even at room temperature)Mega-Calc™ software tool is available from our website for hassle-free raw data processingStandard includedSuitable for manual, microplate and auto-analyser formats... Read More |