| Description | Inquire | Product introduction:Dualucif The firefly & Renilla assay kit (dual luciferase reporter assay kit) provides an effective means to detect the expression of genes. In DLR detection, the activities of firefly luciferase and Renilla luciferase can be detected in a single sample in turn. FirstProduct introduction:Dualucif The firefly & Renilla assay kit (dual luciferase reporter assay kit) provides an effective means to detect the expression of genes. In DLR detection, the activities of firefly luciferase and Renilla luciferase can be detected in a single sample in turn. First, luciferin was used as substrate to detect the activity of firefly luciferase, then substances inhibiting the catalysis of firefly luciferase were added, and coelenterazine was added to detect the activity of Renilla luciferase to achieve dual luciferase reporter gene detection. The bioluminescence system of luciferase and its substrate can detect gene expression very sensitively and efficiently. Usually, the transcriptional regulatory element or 5'promoter region of the gene of interest is cloned upstream of luciferase, or the 3'-utr region is cloned downstream of luciferase to construct a reporter gene plasmid, and then transfect the cells. After the cells are treated with appropriate drugs, the cells are lysed, and the transcriptional regulation effect of drug treatment on the target gene is judged by detecting the luciferase activity. Renilla luciferase is more often used as an internal reference for detecting transfection efficiency to eliminate the difference in cell number and transfection efficiency. Firefly luciferase is a protein with a molecular weight of about 61 kDa. In the presence of ATP, magnesium ions and oxygen, it can catalyze the production of oxyluciferin from luciferin. In the process of luciferin oxidation, it will produce a light signal. Renilla luciferase is a protein with a molecular weight of about 36 kDa. In the presence of oxygen, it can catalyze the oxidation of coelenteramide to coelenteramide, and also produce light signals in the process of coelenteramide oxidation. The optical signal of this kit can be measured by chemiluminescence instrument, microplate reader or liquid scintillation tester. The kit has the characteristics of rapid detection, high sensitivity, wide detection range and no interference of cell endogenous activity.Instruction:1.Cell lysis ( 1 ) Remove the medium and gently wash twice with PBS ( adherent cells can be operated directly, suspension cells need to be centrifuged to collect cells ). Add 1 × Lysis Buffer ( diluted component A with sterile water at 4 : 1 ) according to the following scheme, and then place the culture plate on a micro-oscillator at room temperature for 15 min to fully lyse the cells. Note : The pyrolysis products can be stored at room temperature for 6 h, and can be stored at − 70 °C for a long time ( the pyrolysis products cannot be repeatedly frozen and thawed ). ( 2 ) The pyrolysis products were centrifuged at 10000-15000 rpm for 3-5 min. After centrifugation, the supernatant was transferred into a new EP tube for subsequent detection. Note : Cells can be detected immediately after lysis, or frozen, and re-detected when needed. The frozen samples need to be thawed to room temperature for detection. 2. Preparation of working fluid ( 1 ) Restore all components to room temperature. ( 2 ) Dilute component C with component B to 0.2 mg / mL firefly luciferase working solution. Note : The firefly luciferase working solution cannot be repeatedly frozen and thawed. If the amount of a single experiment is small, it is recommended to be subpackaged into small specifications according to a single amount of use. ( 3 ) The E component was diluted into the renilla luciferase working solution with the D component, and the dilution method was 1 µL E component was added to the 49 µL D component. Note : Renilla luciferase working solution needs to be prepared now. 3.chemiluminescence value detection ( 1 ) According to the operation instructions of the instrument, the instrument with chemiluminescence detection function was opened, such as multifunctional microplate reader. The parameters were set, the determination time was 10 s, and the determination interval was 2 s. ( 2 ) each sample determination, take the sample 20-100 µL ( if the sample volume is enough, please add 100 µL ; if the sample amount is insufficient, the amount can be appropriately reduced, but the amount of detection holes needs to be consistent ). 1 × Lysis Buffer was blank control. ( 3 ) 100 µL firefly luciferase working solution was added to determine the RLU ( relative light unit ) value ( it is recommended that the microplate reader set up the Shaking mixing function ). Note : Since the luminescence is instantaneous, it is recommended to detect immediately after adding the firefly luciferase working solution. ( 4 ) 100 µL renilla luciferase working solution was added to determine the RLU ( relative light unit ) value ( Shaking mixing function is recommended for microplate reader ). ( 5 ) In the case of renilla luciferase as an internal reference, the RLU value measured by firefly luciferase was divided by the RLU value measured by renilla luciferase. According to the obtained ratio, the activation degree of the target reporter gene between different samples was compared. If firefly luciferase is used as an internal reference, similar calculations can also be performed.Component:Recommendation:It is recommended to use component B in advance to prepare 2 mg / mL storage solution, component B, component D and component C prepared as storage solution, and to carry out small batch packing according to the experimental requirements. All test working fluids are recommended to be used now to avoid repeated freezing and thawing.Matters needing attention:1. please centrifuge the product to the bottom of the tube immediately before use, and then conduct subsequent experiments. 2. in order to obtain the best determination effect, when using a single tube chemiluminescence instrument for determination, the time from the mixing of sample and determination reagent to the pre determination should be controlled as much as possible; When using a multi-functional fluorescent microplate reader with chemiluminescence detection function, it is advisable to add all samples first, and then uniformly add firefly luciferase detection reagent. 3. the strongest wavelength of firefly luciferase catalyzed bioluminescence is 560 nm, and the strongest wavelength of Renilla luciferase catalyzed bioluminescence is 480 nm. 4. to prevent interference between holes, it is recommended to use white opaque orifice plate. 5. due to the influence of temperature on enzyme reaction, the sample and reagent should be measured after reaching room temperature. 6. for your safety and health, please wear experimental clothes and disposable gloves.Scope of application:Study on gene expression regulation and promoter... Read More | M666110 Component 96 T Storage M666110A Buffer WSL 40 mL RT M666110B Buffer MSL 40 mL RT M666110C Buffer CW1 (concentrate) 90 mL RT M666110D Buffer GW1 (concentrate) 40 mL RT M666110E Buffer GW2 (concentrate) 50 mL RT M666110F Buffer EB 30 mL RT M666110G Proteinase K 4×1.25 mL RT M666110H M666110 Component 96 T Storage M666110A Buffer WSL 40 mL RT M666110B Buffer MSL 40 mL RT M666110C Buffer CW1 (concentrate) 90 mL RT M666110D Buffer GW1 (concentrate) 40 mL RT M666110E Buffer GW2 (concentrate) 50 mL RT M666110F Buffer EB 30 mL RT M666110G Proteinase K 4×1.25 mL RT M666110H Magbeads V3 2×1 mL RTProduct Introduction:The reagent kit provides a simple, fast, and efficient method for extracting genomic DNA from blood samples. In the presence of high salt, DNA binds to the surface of silica coated Magheads. After rinsing, high-purity DNA is eluted in Buffer EB or deionized water. The purified DNA has good purity (A260/280 ratio between 1.7-1.9) and high integrity (>15 kb), and can be used for downstream experiments such as second-generation sequencing, quantitative PCR, and chip detection.Self provided instruments and reagents1) Constant temperature mixer2) 2/15 ml magnetic frame3) 32 channel nucleic acid extractor4) 96 channel nucleic acid extractor5) 96 DW Plate6) 8 channel Comb7) Spin tips pack8) Anhydrous ethanolPreparation and important precautions before the experiment1.Before the first use, add anhydrous ethanol to Buffer CW1, Buffer GW1, and Buffer GW2 according to the label of the reagent bottle and mark them properly.2.Magheads are strictly prohibited from freezing or centrifugation. Freezing and centrifugation may cause irreversible damage to Magheads.Operation stepsI. Manual single tube operation1. Use punching forceps to take 1 blood spot with a diameter of 6 mm or 4 blood spots with a diameter of 3 mm (depending on the actual situation) from the blood spot and place them in a 2.0 mL centrifuge tube.2. Add 40 to the centrifuge tube µ L Protein K and 300 µ L Buffer WSL, then place the centrifuge tube on a constant temperature mixer at 75 ℃ and 1200 rpm, shake and crack for 45 minutes to form Lysate. Remove the centrifuge tube from the constant temperature mixer, centrifuge briefly, and take the supernatant.Attention: If there is no constant temperature mixer, vortex the centrifuge tube for 10 seconds and incubate it in a 75 ℃ water bath for 30 minutes. During this period, vortex every 10 minutes for 10 seconds.3. Suck the supernatant into a new 2.0 mL centrifuge tube and add 300 µ L Buffer MSL, 300 µ L isopropanol and 20 µ L Magheads V3. Afterwards, place the centrifuge tube on a constant temperature mixer at 25 ℃ and 1600 rpm, shake and crack for 15 minutes, or invert the centrifuge tube and mix continuously for 15 minutes.4. Place the centrifuge tube on a magnetic stand and let it stand for 1 minute. After Magheads are completely adsorbed on the side wall of the centrifuge tube, discard the solution thoroughly (keep the centrifuge tube fixed on the magnetic stand).5. Remove the centrifuge tube from the magnetic frame and add 900 µ L Buffer CW1 (please check if anhydrous ethanol has been added before use), vortex point shake for 1 minute or vortex shake for 5 seconds, and then place it on a constant temperature mixer at 25 ℃ and 1600 rpm to shake and mix for 2 minutes (ensure that Magheads are in a mixed state during the shaking process). Afterwards, place the centrifuge tube on a magnetic stand and let it stand for 1 minute. After Magheads are completely adsorbed on the side wall of the centrifuge tube, gently invert the magnetic stand and wash the impurities on the centrifuge tube cover to completely discard the solution (keep the centrifuge tube fixed on the magnetic stand).6. Remove the centrifuge tube from the magnetic frame and add 500 µ L Buffer GW1 (please check if anhydrous ethanol has been added before use), vortex point shake for 1 minute or vortex shake for 5 seconds, and then place it on a constant temperature mixer at 25 ℃ and 1600 rpm to shake and mix for 2 minutes (ensure that Magheads are in a mixed state during the shaking process). Afterwards, place the centrifuge tube on a magnetic stand and let it stand for 1 minute. After Magheads are completely adsorbed on the side wall of the centrifuge tube, gently invert the magnetic stand and wash the impurities on the centrifuge tube cover to completely discard the solution (keep the centrifuge tube fixed on the magnetic stand).7. Remove the centrifuge tube from the magnetic frame and add 900 µ L Buffer GW2 (please check if anhydrous ethanol has been added before use), vortex point shake for 1 minute or vortex shake for 5 seconds, then place it on a constant temperature mixer at 25 ℃ and 1600 rpm, shake and mix for 2 minutes (ensure that Magheads are in a mixed state during the shaking process). Afterwards, place the centrifuge tube on a magnetic stand and let it stand for 1 minute. After Magheads are completely adsorbed on the side wall of the centrifuge tube, gently invert the magnetic stand and wash the impurities on the centrifuge tube cover to completely discard the solution (keep the centrifuge tube fixed on the magnetic stand).8. Remove the centrifuge tube from the magnetic frame and add 300 µ After shaking with 75% ethanol for 1 minute or 5 seconds, place the mixture on a constant temperature mixer at 25 ℃ and 1600 rpm for 2 minutes (ensure that the Magheads are in a mixed state during the shaking process). Afterwards, place the centrifuge tube on a magnetic stand and let it stand for 1 minute. After Magheads are completely adsorbed on the side wall of the centrifuge tube, gently invert the magnetic stand and wash the impurities on the centrifuge tube cover to completely discard the solution (keep the centrifuge tube fixed on the magnetic stand).9. Keep the centrifuge tube fixed on the magnetic frame, use a pipette to further remove the solution from the bottom and cover of the centrifuge tube, and then leave it at room temperature for 5-10 minutes to allow the ethanol to evaporate completely.10. Remove the centrifuge tube from the magnetic frame and add 50-200 µ L Buffer EB. Vortex oscillation causes the magnetic beads to completely suspend in the eluent and then place them on a constant temperature mixer at 56 ℃ and 1600 rpm for 10 minutes of shaking and elution, or incubate the centrifuge tube in a 56 ℃ water bath for 10 minutes, with vortex oscillation every 3 minutes for 10 seconds.11. Place the centrifuge tube on a magnetic stand and let it stand for 2 minutes. After Magheads are completely adsorbed on the side wall of the centrifuge tube, transfer the eluent to a new centrifuge tube using a pipette and store at -20 ℃ for later use.II. Matching with CWE21001. Use punching forceps to take 1 blood spot with a diameter of 6 mm or 4 blood spots with a diameter of 3 mm (depending on the actual situation) from the blood spot and place them in a 2.0 mL centrifuge tube.2. Add 40 to the centrifuge tube µ L Protein K and 300 µ L Buffer WSL, then place the centrifuge tube on a constant temperature mixer at 75 ℃ and 1200 rpm, shake and crack for 45 minutes to form Lysate.3. Add the corresponding reagents to the 96DW deep well plate according to the table below. Position Reagent 1&7 Colume Lysate: All Buffer MSL: 300 µL isopropanol:300 µL Magbeads V3: 20 µL 2&8 Colume Buffer CW1: 900 µL 3&9 Colume Buffer GW1: 500 µL 4& 10 Colume Buffer GW2: 900 µL 5& 11 Colume 75%ethanol: 300 µL 6& 12 Colume Buffer EB: 70 µL4.Place the deep well plate and magnetic sleeve that have been added to the reagent at the corresponding positions of CWE2100/CWE3200, run the blood slide extraction program, and after about 40 minutes, the program ends. Remove the deep well plate and magnetic sleeve.5.Transfer the elution products from columns 6 and 12 of the deep well plate to a 1.5 mL centrifuge tube for low-temperature storage.III. Matching with CWE9601. Use punching forceps to take 1 blood spot with a diameter of 6 mm or 4 blood spots with a diameter of 3 mm (depending on the actual situation) from the blood spot and place them in a 2.0 mL centrifuge tube.2. Add 40 to the centrifuge tube µ L Protein K and 300 µ L Buffer WSL, then place the centrifuge tube on a constant temperature mixer at 75 ℃ and 1200 rpm, shake and crack for 45 minutes to form Lysate.3. Add the corresponding reagents to the 96DW deep well plate according to the table below Position Reagent Plate 1 Lysate: All Buffer MSL: 300 µL isopropanol :300 µL Magbeads V3: 20 µL Plate 2 Buffer CW1: 900 µL Plate 3 Buffer GW1: 500 µL Plate 4 Buffer GW2: 900 µL Plate 5 75% ethanol : 300 µL Plate 6 Buffer EB: 70 µL4. Place the deep well plate and magnetic sleeve that have been added to the reagent at the corresponding positions on CWE960, run the blood slide extraction program, and after about 40 minutes, the program ends. Remove the deep well plate and magnetic sleeve.5. Transfer the elution products from Plate 6 to a 1.5 mL centrifuge tube for low-temperature storage... Read More | Products contentN665737Component24 T96 TStorageN665737ATPS V50 168 µL672 µL-20℃. Avoid freeze/thaw cycle.N665737B5×FA Reaction Buffer96 µL384 µL-20℃. Avoid freeze/thaw cycle.N665737CTS Buffer72 µL288 µL-20℃. Avoid freeze/thaw cycle.N665737D2×Products contentN665737Component24 T96 TStorageN665737ATPS V50 168 µL672 µL-20℃. Avoid freeze/thaw cycle.N665737B5×FA Reaction Buffer96 µL384 µL-20℃. Avoid freeze/thaw cycle.N665737CTS Buffer72 µL288 µL-20℃. Avoid freeze/thaw cycle.N665737D2×PCR Mix600 µL2×1.2 mL-20℃. Avoid freeze/thaw cycle. * This kit is suitable for human genomic DNA library construction, the starting template DNA input is 5 ng. We also have transposase library construction kits for 50 ng and 1 ng of human genomic DNA starting, in order to get a higher quality library, it is recommended to use different kits for different starting amount of DNA. Products IntroductionThis kit is developed for Illumina's high-throughput sequencing platform and provides the enzyme premix system and reaction buffer for genomic DNA library construction, including all components except PCR primers. Compared with the traditional library construction kits, this kit adopts the new transposase method for library construction, which can complete DNA fragmentation, end repair and junction reaction in one simple enzymatic reaction, significantly reducing the amount of template, reducing the number of experimental steps, and shortening the time of library construction; it adopts the high-fidelity DNA polymerase for library enrichment, and the preference-free PCR amplification can expand the coverage area of the sequence, which can be used for efficient and effective sequencing. The use of high-fidelity DNA polymerase for library enrichment and preference-free PCR amplification broadens the coverage area of the sequence and enables efficient preparation of DNA libraries for Illumina's second-generation sequencing platform. The kit is suitable for use with a starting template DNA input of 5 ng, and all reagents in the kit have been subjected to stringent quality control and functional validation to maximize the stability and reproducibility of library construction. Product Features● DNA fragmentation and junction ligation in one step.● Ultra-fidelity amplification minimizes amplification preference.Provide your own instruments, kits and consumables1. Magnetic frame: DynaMagTM-2 is recommended.2. DNA purification and recovery kit: It is recommended to use DNA purification and recovery kit by magnetic bead method.3. Library PCR primer kit: It is recommended to use transposase method for second generation sequencing multi-sample primer kit.4. Anhydrous ethanol, deionized water (pH between 7.0 and 8.0).5. Reaction tubes: It is recommended to use low adsorption PCR tubes and 1.5 ml centrifuge tubes. Tips: It is recommended to use high quality filter tips to prevent contamination of kits and library samples. Pre-experiment Preparation and Important Notes1. Avoid repeated freezing and thawing of reagents.2. PCR products are easily contaminated due to improper operation, resulting in inaccurate results. It is recommended to isolate the PCR reaction system preparation area from the PCR product purification area, and to use special pipettes to clean the experimental areas at regular intervals.3. Bead purification: the beads should be equilibrated to room temperature before use, all operations on the beads should be carried out at room temperature, 80% ethanol should be dispensed freshly, the beads should be rinsed and dried until the surface is free of liquid reflections and has a frosted appearance, insufficient drying of the beads will cause ethanol residue that will affect the subsequent experiments, and over-drying of the beads will affect the efficiency of DNA recovery.4. The kit is suitable for human genomic DNA library construction, if the DNA sample is a PCR product, it should be ensured that its length>.500 bp, since transposases do not work on DNA ends, it is recommended to extend the PCR product by 50-100 bp at each end of the PCR product to avoid low coverage of the ends for sequencing. Sample PreparationDNA purity requirements: A260/A280 = 1.8-2.0. Sample DNA: dissolve in ultrapure water. DNA Quantification: Too much or too little DNA will affect the quality of the library. It is recommended to use Nano to test the purity of the genomic DNA and then use Qubit to test the concentration of the genome (do not use any absorbance-based assay for template quantification). Schematic diagram of DNA banking processprocedureDNA fragmentation, junction reaction 1. Add the following reagents to a 200 µl PCR tube: 2. Mix by gently blowing with a pipette and centrifuge briefly so that all components are collected at the bottom of the tube.3. Place the above PCR tubes in the PCR instrument with the hot cap on and program the reaction as follows: inactivation reactionAfter the DNA is fragmented, the enzyme is still in a high active state, so it should be removed from the PCR instrument immediately and terminated by adding the Reaction Termination Buffer, in order to prevent the DNA from being fragmented too much and resulting in smaller library fragments.1. Add 3 µl of TS Buffer to the PCR tube containing the fragmentation product.2. Mix by gently blowing with a pipette and centrifuge briefly so that all components are collected at the bottom of the tube.3. Incubate at room temperature for 5 min, or if the room temperature is too low, place the reaction on a PCR instrument at 25°C with the thermal cover closed.1. Add the following reagents to a 200 µl PCR tube.2. Mix by gently blowing with a pipette and centrifuge briefly so that all components are collected at the bottom of the tube.3. Place the above PCR tubes in the PCR instrument with the hot cap on and program the reaction as follows Selective recovery of library DNA fragmentsIt is recommended to use CombiVision Magnetic Beads DNA Purification and Recovery Kit for selective recovery of DNA fragments. When different sizes of DNA fragments are required, the amount of magnetic beads used is different, please refer to the attached table for the specific amount of magnetic beads used.(If using other brands of magnetic beads, you need to figure out the optimal amount of magnetic beads by yourself).Note: Amplification products can also be fragment length sorted and purified using the Gum Recovery Kit. If there is no special requirement for library length distribution, amplification products can also be purified directly from DNA fragments without selective recovery of DNA fragments as described on page 4 of the manual.1. CMPure should be equilibrated at room temperature for 30 min after shaking and mixing before use.2. Transfer the PCR products to a 1.5 ml centrifuge tube, rehydrate to 100 µl, add several volumes of magnetic beads equilibrated to room temperature, vortex for 5 seconds, and let stand at room temperature for 5 minutes.3. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant until the solution is clear, and carefully aspirate the supernatant and transfer it to a new 1.5 ml centrifuge tube.Note: Do not discard the top clear.4. Add several volumes of magnetic beads to the supernatant, vortex and shake for 5 seconds, then let stand at room temperature for 5 minutes.5. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant until the solution is clear, carefully aspirate the supernatant and discard it, avoiding contact with the beads that have bound the target DNA.Note: Do not discard the beads.6. Continue to keep the centrifuge tube fixed on a magnetic rack and add 200 µl of freshly prepared 80% ethanol to the tube and allow to stand at room temperature for 30 seconds, carefully discarding the supernatant.Note: When adding ethanol, the liquid must not be blown directly onto the beads.7. Repeat step 6 once.8. Keep the centrifuge tube fixed on a magnetic rack and leave to dry at room temperature until the surface of the beads is slightly cracked, add 20 µl of ddH2O to solubilize.Note: Do not over-dry the beads as this may affect the elution efficiency.9. Remove the centrifuge tube from the magnetic rack, vortex to completely resuspend the beads, and allow to stand at room temperature for 5 minutes. Centrifuge briefly, place the tube on the magnetic rack until the solution is clear, and transfer the supernatant solution to a new centrifuge tube. Table: Suggested amount of magnetic beads for different segment selection recovery Library DNA fragment purificationWe recommend the use of the Century Magnetic Bead Method DNA Purification and Recovery Kit.1. CMPure should be equilibrated at room temperature for 30 min after shaking and mixing before use.2. 50 µl of magnetic beads equilibrated to room temperature were added to the PCR product, vortexed and shaken for 5 seconds, and then left to stand at room temperature for 5 minutes.3. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant solution until the solution is clear (approximately 3-5 minutes), carefully aspirate the supernatant and discard it, avoiding contact with the beads that have bound the target DNA. Note: Do not discard the beads.4. Continue to keep the centrifuge tube fixed on a magnetic rack and add 200 µl of freshly prepared 80% ethanol to the centrifuge tube and allow to stand at room temperature for 30 seconds, carefully discarding the supernatant.Note: When adding ethanol, the liquid must not be blown directly onto the beads.5. Repeat step 4.6. Keep the centrifuge tube fixed on a magnetic rack and leave to dry at room temperature until the surface of the beads is slightly cracked, add 25 µl of ddH O to solubilize.Note: Do not over-dry the beads as this may affect the elution efficiency.7. Remove the tube from the magnetic rack, vortex to completely resuspend the beads, and allow to stand at room temperature for 5 minutes. Centrifuge briefly, place the tube on the magnetic rack until the solution is clear, and transfer the supernatant solution to a new tube. Library quality controlDetermination of library concentrationIn order to obtain high-quality sequencing results, accurate quantification of DNA libraries is required, and the first recommendation is to use Real-timePCR methods are used for absolute quantification of DNA libraries. Additionally, fluorescent dye methods such as the Qubit method or the fluorescent dye picogreen method can be used; do not use quantification methods based on absorbance measurements here. The following approximate formula can be used to convert the molar concentration of the DNA library. Library fragment distributionThe prepared DNA libraries can be detected by agarose gel electrophoresis or Agilent 2100 Bioanalyzer.Range of segment length distributions... Read More | Product content N665859Component50 TStorageN665859ABuffer DS30 mLRTN665859BBuffer GTL15 mLRTN665859CBuffer GL15 mLRTN665859DBuffer GW1 (concentrate)13 mLRTN665859EBuffer GW2 (concentrate)15 mLRTN665859FBuffer TE10 mLRTN665859GProteinase K2×1.25 mLRTN665859HRNase A (100 mg/mL)0.4 Product content N665859Component50 TStorageN665859ABuffer DS30 mLRTN665859BBuffer GTL15 mLRTN665859CBuffer GL15 mLRTN665859DBuffer GW1 (concentrate)13 mLRTN665859EBuffer GW2 (concentrate)15 mLRTN665859FBuffer TE10 mLRTN665859GProteinase K2×1.25 mLRTN665859HRNase A (100 mg/mL)0.4 mLRTN665859ISpin Columns DF With Collection Tubes50 EA2-8℃N665859JCentrifuge Tubes (L-1.5 mL)50 EART Product IntroductionThis kit is suitable for the effective purification of genomic DNA from formalin-fixed, paraffin-embedded tissues.The product uses specially optimized dewaxing agent and lysis solution to release DNA from formalin-fixed or tissue sectioned samples, which does not involve the organic reagent xylene and does not need to be operated overnight; the digested samples are incubated at higher temperatures to remove formalin cross-linking of the free DNA, which can effectively improve the yield and purity of DNA; the optimized buffer system allows the inhibitors in the lysis solution to be specifically bound to the adsorbent membrane, which can be effectively removed by a two-step rinsing step. The optimized buffer system enables the DNA in the lysate to specifically bind to the adsorbent membrane, and the inhibitor is effectively removed by a two-step rinsing step, and finally eluted with low-salt buffer or water to obtain high-purity DNA.Meanwhile, configured with a high-efficiency microsorbent column, the elution volume can be as low as 20 µL.The purified DNA can be directly used for PCR, Real-time PCR, SNP Genotyping, STR genotyping, second-generation sequencing and pharmacogenomics research.The molecular weight of DNA isolated from formalin-fixed, paraffin-embedded samples is usually lower than that of DNA from fresh or frozen samples.The degree of DNA fragmentation depends on the type of sample, the duration of storage, and the conditions of fixation.Self-contained reagent: anhydrous ethanolPre-experiment Preparation and Important Notes1. After obtaining the sample, fix the sample in 4%-10% formalin as soon as possible, the fixation time should be 14-24 hours, too long a period of time will easily lead to genome breakage, affecting the downstream experiments. If the formaldehyde fixation time is too long or the sample has been stored for too long (> 1 year), it will easily lead to DNA integrity damage and unable to amplify long fragments.2. Ensure that the sample is thoroughly dehydrated before embedding; residual formalin will inhibit Proteinase K.3. Anhydrous ethanol should be added to Buffer GW1 and Buffer GW2 according to the instructions on the label of the reagent bottle before first use.4. Before use, please check Buffer GTL, Buffer GL and Buffer DS for any crystallization or precipitation. If there is any crystallization or precipitation, please re-dissolve Buffer GTL, Buffer GL and Buffer DS at 56℃ in a water bath.5. Preheat the water bath or thermostatic mixer to 56°C and keep the centrifuge at 25°C before starting the experiment.6. If downstream experiments are needed to reduce the low frequency of C>T:G>A transitions (artificial mutations) that occur to minimize the risk of false positives, 7 µL of UNG (1 U/uL) can be added after 1 hour of incubation at 90°C.Operation steps1. Sample processing:1a. Paraffin-embedded samples: Trim off excess paraffin from the tissue block with a scalpel to expose the tissue and then cut into 5-10µm slices. Take about 1×1cm2 slices (about 4-5 slices in total) and place them in a centrifuge tube (provided), add 160µL Buffer DS, vortex and shake for 10 seconds, then add 180µL Buffer GTL and 20µL Proteinase K, vortex and shake for 10 seconds. centrifuge the samples at 12,000rpm for 1 minute at 25℃.Note: 1) If the surface of the sample has been exposed to air, discard the 2-3 pieces that have been exposed to air and do not use them.2) DS will solidify below 18°C, and if it does it does not affect the following experiments.1b. Sample in formalin and other fixative: take about 20mg of sample, cut it into small pieces, place it in a centrifuge tube, add 500µL of 10mM PBS (PH7.4), vortex shaking, centrifuge at 12,000rpm for 1minute, discard the supernatant, and repeat 3 times. Add 180 µL Buffer GTL, 20 µL Proteinase K, vortex shaking to mix.2.56°C for 1 hour until the sample is completely dissolved. incubate at 90°C for 1 hour. centrifuge at 12,000 rpm, 25°C for 1 minute, and carefully pipette the lower aqueous phase (~180 µL) along the wall of the tube into a new centrifuge tube, trying to avoid aspirating the bottom precipitate and the upper layer of the wax solution.Note: 1) Samples can be left at room temperature after incubation at 56°C until the temperature of the water or dry bath reaches 90°C before placing the samples at 90°CIncubation.2) Optional step: add 7µL UNG (1U/µL), 50°C, 5min, no shaking. The purpose of this step is to minimize the risk of false positives by reducing the low-frequency occurrence of C>T:G>A transitions (artificial mutations) while effectively retaining the true occurrence of mutations.3. Optional step: If you need to remove RNA, you can lower the temperature of the sample to room temperature, then add 2µL of RNase A solution at a concentration of 100mg/mL, shake and mix well, and leave it at room temperature for 2 minutes.4. Add 20µL Proteinase K and incubate at 65℃, 450rpm for 15min.5. Add 200 µL of Buffer GL, mix well by vortexing and shaking, then add 200 µL of anhydrous ethanol and mix thoroughly by vortexing and shaking. Centrifuge briefly so that the solution on the wall of the tube collects at the bottom of the tube.Note: 1) Mix well immediately after adding Buffer GL and anhydrous ethanol.2) The addition of Buffer GL and anhydrous ethanol may produce a white precipitate that will not affect subsequent experiments.3) If more than one sample needs to be manipulated, the Buffer GL and anhydrous ethanol can be pre-mixed and spiked.6. Add all the solution obtained in step 5 to the adsorption columns (Spin Columns DF) that have been loaded into the collection tube, centrifuge at 25℃, 12000rpm for 2 minutes, pour out the waste liquid in the collection tube, and put the adsorption columns back into the collection tube.7. Add 500µL of Buffer GW1 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12,000rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorption column back into the collection tube.8. Add 500µL of Buffer GW2 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12000rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorption column back into the collection tube.Note: Step 8 can be repeated if further DNA purity is required.9.12 Centrifuge at 2000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Leave the adsorption column at room temperature for several minutes to dry thoroughly.Note: The purpose of this step is to remove residual ethanol from the adsorption column; ethanol residue can interfere with subsequent enzymatic reactions.10. Place the adsorption column in a new 1.5 mL collection tube, add 20-100 µL of Buffer TE or sterilized water to the middle of the adsorption column overhanging the column, let it stand at room temperature for 2-5 minutes, centrifuge it at 12,000 rpm for 1 minute, and collect the DNA solution.-20°C to preserve DNA.Note: 1) The pH value of the eluent has a great influence on the elution efficiency, if water is used as the eluent should ensure that its pH value is 7.0-8.5, the pH value is lower than 7.0 when the elution efficiency is not high.2) If the final concentration of DNA is to be increased, the DNA eluate obtained in step 10 can be re-spiked onto the adsorbent membrane and left at room temperature for 2 minutes and centrifuged at 12,000 rpm for 1 minute... Read More |