| Description | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export | CFDASE cell proliferation and tracking detection kit is a kit for cell proliferation and tracking detection based on CFDA se. This kit is composed of CFDASE powder, solvent and staining buffer. CFDASE is a derivative of fluorescein diacetate (FDA), which has cell membrane permeability and CFDASE cell proliferation and tracking detection kit is a kit for cell proliferation and tracking detection based on CFDA se. This kit is composed of CFDASE powder, solvent and staining buffer. CFDASE is a derivative of fluorescein diacetate (FDA), which has cell membrane permeability and does not have fluorescence luminescence. When CFDASE penetrates the cell membrane into living cells, it can be catalysed by esterases in the cytosol to produce carboxyfluorescein succinimidyl ester (CFSE), which can emit strong green fluorescence, cannot penetrate the cell membrane, and can remain intact in the cell. CFSE can also spontaneously and irreversibly covalently bind to intracellular amino groups to couple to cellular proteins. Meanwhile, the excess and uncoupled CFDASE returned to the extracellular medium by passive diffusion and was cleared by subsequent washing steps. The fluorescence of non dividing cells labeled by CFDASE is very stable, and the stable labeling time can reach several months, so it is very suitable for cell community analysis. The fluorescence of CFDASE labeled cells is very homogeneous, which is superior to other cell tracking fluorescent probes used previously, such as PKH26, and the fluorescence distribution of the divided progeny cells is also very uniform. In the process of cell division and proliferation, CFSE labeled fluorescence can be evenly distributed to the two progeny cells, and the fluorescence intensity becomes half of the parental cells. According to the fluorescence intensity, flow cytometer (FL1 channel) can detect undivided cells, cells that divide once (1 / 2 of the fluorescence intensity), twice (1 / 4 of the fluorescence intensity), three times (1 / 8 of the fluorescence intensity), and cells that divide more times. CFDASE can detect up to eight or more cleavages. CFDASE labeled cells can be used for proliferation studies in vitro and in vivo, and have the function of not staining adjacent cells. CFDASE is most commonly used to detect the proliferation of lymphocytes, and can also be used to detect the proliferation of fibroblasts, NK cells and other cells. CFDASE labeled cells showed green fluorescence. In addition to flow cytometry to detect cell proliferation, fluorescence microscopy can also be used for homogeneous staining of cell tracking observation.Components:ComponentsC598182-20TC598182-500TA. CFDA SE1 tube1 tubex5B.CFDA SE solvent20 µL500 µLC.10x CFDA SE Buffer1 mL x250 mLMatters needing attention:1. please centrifuge the product to the bottom of the tube immediately before use, and then conduct subsequent experiments. 2. CFDA and Se are easily hydrolyzed and will deteriorate quickly in aqueous solution. Please avoid contact with water during use. Contact with water during the process of labeling cells is within the permitted range. 3. CFDA se solvent will solidify at lower temperatures such as 4 º C and ice bath and stick to the bottom, wall or cover of the centrifugal tube. It can be used after incubating in a 20-25 º C water bath for a while until it is completely dissolved. 4. this kit optimizes the CFDA se staining system, but users are advised to explore the optimal working concentration and staining time according to their own cell type, culture conditions and application direction. Different cells have different lactonase activities, so the staining effect is different. 5. fluorescent dyes have quenching problems. Please avoid light during operation to slow down fluorescence quenching. 6. for your safety and health, please wear experimental clothes and disposable gloves.Usage method:1. Preparation of reagents(1) Preparation of CFDA SE storage solution: Take one tube of CFDA SE provided in the reagent kit and restore it to room temperature. Instantly centrifuge to allow the powder to fully settle to the bottom of the tube. Add 100 µ L CFDA SE solvent (add 20 µ L CFDA SE solvent) to it and dissolve it thoroughly to prepare CFDA SE storage solution (1000 ×). Prepared CFDA SE storage solution, stored at -20 ℃ in the dark, with a shelf life of two months- Storing at 70 ℃ in the dark can extend the usage time appropriately.(2) Preparation of CFDA SE Buffer: Dilute 10 x CFDA SE Buffer to 1 x with sterile cell culture grade water as needed. The prepared 1 × CFDA SE Buffer can be stored at 4 ℃ and can be stored at -20 ℃ if not in use for a long time.2. Marking and detection(1) Centrifuge the collected cells, use 1 mL 1 × CFDA SE Buffer to re suspend the cells in a 15 mL centrifuge tube, and adjust the cell concentration to 1-5 × 106 cells/mL.(2) Preparation of CFDA SE working solution: Dilute the CFDA SE storage solution (1000 ×) with 1 × CFDA SE Buffer to 2 ×.(3) Staining: Add 1 mL of CFDA SE working solution (2 x) to 1 mL of cell suspension to be labeled, invert and mix well, and incubate at 37 ℃ for 10 minutes.(4) Immediately add 5 times the volume of preheated complete culture medium (including serum) to the centrifuge tube, invert and mix well to terminate the labeling reaction.(5) Centrifuge at 1000 rpm for 5 minutes at room temperature to remove the supernatant, then wash once with 5-10 mL of complete culture medium.(6) Add 5-10 mL of complete culture medium and incubate at 37 ℃ for 5 minutes to promote the residence of CFDA SE in the cells and the entry of unreacted CFDA SE into the complete cell culture medium. Centrifuge at 1000 rpm for 5 minutes at room temperature to remove the supernatant and complete the final wash.(7) Subsequently, the cells can be cultured using the normal cultivation method. The labeling effect can be directly observed under a fluorescence microscope, or cell proliferation can be detected by flow cytometry after appropriate cultivation time, showing green fluorescence. The labeled cells can also be used for transplantation in live animals and for fluorescence tracing.Note: a If cell fixation is required, use aldehyde fixatives such as 4% paraformaldehyde to fix at room temperature for 15 minutes; If additional labeling such as antibody labeling is required afterwards, please permeabilize the cells with ice acetone for 10 minutes. b. The optimal labeling concentration and incubation time for CFDA SE vary for different cells. The initial experiment can be conducted according to the experimental steps. If the effect is not satisfactory, it is recommended to adjust the staining concentration and incubation time to achieve the best labeling effect.Scope of application:Cell proliferation assay... Read More | Ketone bodies, 3-hydroxybutyric acid (BOH) and acetoacetic acid (AcAc), are produced in the liver primarily from oxidation of fatty acids, and are normally present at low concentrations in urine and blood. Increased ketone concentrations in the blood may lead to metabolic acidosis, which has been Ketone bodies, 3-hydroxybutyric acid (BOH) and acetoacetic acid (AcAc), are produced in the liver primarily from oxidation of fatty acids, and are normally present at low concentrations in urine and blood. Increased ketone concentrations in the blood may lead to metabolic acidosis, which has been associated with diabetes, childhood hypoglycemia, growth hormone deficiency, alcohol or salicylate intoxication, and inborn errors of metabolism.Ketone Body Assay has been used to measure the release of ketone bodies in the human liver cancer cell line HepG2 culture medium... Read More | Product content N665859Component50 TStorageN665859ABuffer DS30 mLRTN665859BBuffer GTL15 mLRTN665859CBuffer GL15 mLRTN665859DBuffer GW1 (concentrate)13 mLRTN665859EBuffer GW2 (concentrate)15 mLRTN665859FBuffer TE10 mLRTN665859GProteinase K2×1.25 mLRTN665859HRNase A (100 mg/mL)0.4 Product content N665859Component50 TStorageN665859ABuffer DS30 mLRTN665859BBuffer GTL15 mLRTN665859CBuffer GL15 mLRTN665859DBuffer GW1 (concentrate)13 mLRTN665859EBuffer GW2 (concentrate)15 mLRTN665859FBuffer TE10 mLRTN665859GProteinase K2×1.25 mLRTN665859HRNase A (100 mg/mL)0.4 mLRTN665859ISpin Columns DF With Collection Tubes50 EA2-8℃N665859JCentrifuge Tubes (L-1.5 mL)50 EART Product IntroductionThis kit is suitable for the effective purification of genomic DNA from formalin-fixed, paraffin-embedded tissues.The product uses specially optimized dewaxing agent and lysis solution to release DNA from formalin-fixed or tissue sectioned samples, which does not involve the organic reagent xylene and does not need to be operated overnight; the digested samples are incubated at higher temperatures to remove formalin cross-linking of the free DNA, which can effectively improve the yield and purity of DNA; the optimized buffer system allows the inhibitors in the lysis solution to be specifically bound to the adsorbent membrane, which can be effectively removed by a two-step rinsing step. The optimized buffer system enables the DNA in the lysate to specifically bind to the adsorbent membrane, and the inhibitor is effectively removed by a two-step rinsing step, and finally eluted with low-salt buffer or water to obtain high-purity DNA.Meanwhile, configured with a high-efficiency microsorbent column, the elution volume can be as low as 20 µL.The purified DNA can be directly used for PCR, Real-time PCR, SNP Genotyping, STR genotyping, second-generation sequencing and pharmacogenomics research.The molecular weight of DNA isolated from formalin-fixed, paraffin-embedded samples is usually lower than that of DNA from fresh or frozen samples.The degree of DNA fragmentation depends on the type of sample, the duration of storage, and the conditions of fixation.Self-contained reagent: anhydrous ethanolPre-experiment Preparation and Important Notes1. After obtaining the sample, fix the sample in 4%-10% formalin as soon as possible, the fixation time should be 14-24 hours, too long a period of time will easily lead to genome breakage, affecting the downstream experiments. If the formaldehyde fixation time is too long or the sample has been stored for too long (> 1 year), it will easily lead to DNA integrity damage and unable to amplify long fragments.2. Ensure that the sample is thoroughly dehydrated before embedding; residual formalin will inhibit Proteinase K.3. Anhydrous ethanol should be added to Buffer GW1 and Buffer GW2 according to the instructions on the label of the reagent bottle before first use.4. Before use, please check Buffer GTL, Buffer GL and Buffer DS for any crystallization or precipitation. If there is any crystallization or precipitation, please re-dissolve Buffer GTL, Buffer GL and Buffer DS at 56℃ in a water bath.5. Preheat the water bath or thermostatic mixer to 56°C and keep the centrifuge at 25°C before starting the experiment.6. If downstream experiments are needed to reduce the low frequency of C>T:G>A transitions (artificial mutations) that occur to minimize the risk of false positives, 7 µL of UNG (1 U/uL) can be added after 1 hour of incubation at 90°C.Operation steps1. Sample processing:1a. Paraffin-embedded samples: Trim off excess paraffin from the tissue block with a scalpel to expose the tissue and then cut into 5-10µm slices. Take about 1×1cm2 slices (about 4-5 slices in total) and place them in a centrifuge tube (provided), add 160µL Buffer DS, vortex and shake for 10 seconds, then add 180µL Buffer GTL and 20µL Proteinase K, vortex and shake for 10 seconds. centrifuge the samples at 12,000rpm for 1 minute at 25℃.Note: 1) If the surface of the sample has been exposed to air, discard the 2-3 pieces that have been exposed to air and do not use them.2) DS will solidify below 18°C, and if it does it does not affect the following experiments.1b. Sample in formalin and other fixative: take about 20mg of sample, cut it into small pieces, place it in a centrifuge tube, add 500µL of 10mM PBS (PH7.4), vortex shaking, centrifuge at 12,000rpm for 1minute, discard the supernatant, and repeat 3 times. Add 180 µL Buffer GTL, 20 µL Proteinase K, vortex shaking to mix.2.56°C for 1 hour until the sample is completely dissolved. incubate at 90°C for 1 hour. centrifuge at 12,000 rpm, 25°C for 1 minute, and carefully pipette the lower aqueous phase (~180 µL) along the wall of the tube into a new centrifuge tube, trying to avoid aspirating the bottom precipitate and the upper layer of the wax solution.Note: 1) Samples can be left at room temperature after incubation at 56°C until the temperature of the water or dry bath reaches 90°C before placing the samples at 90°CIncubation.2) Optional step: add 7µL UNG (1U/µL), 50°C, 5min, no shaking. The purpose of this step is to minimize the risk of false positives by reducing the low-frequency occurrence of C>T:G>A transitions (artificial mutations) while effectively retaining the true occurrence of mutations.3. Optional step: If you need to remove RNA, you can lower the temperature of the sample to room temperature, then add 2µL of RNase A solution at a concentration of 100mg/mL, shake and mix well, and leave it at room temperature for 2 minutes.4. Add 20µL Proteinase K and incubate at 65℃, 450rpm for 15min.5. Add 200 µL of Buffer GL, mix well by vortexing and shaking, then add 200 µL of anhydrous ethanol and mix thoroughly by vortexing and shaking. Centrifuge briefly so that the solution on the wall of the tube collects at the bottom of the tube.Note: 1) Mix well immediately after adding Buffer GL and anhydrous ethanol.2) The addition of Buffer GL and anhydrous ethanol may produce a white precipitate that will not affect subsequent experiments.3) If more than one sample needs to be manipulated, the Buffer GL and anhydrous ethanol can be pre-mixed and spiked.6. Add all the solution obtained in step 5 to the adsorption columns (Spin Columns DF) that have been loaded into the collection tube, centrifuge at 25℃, 12000rpm for 2 minutes, pour out the waste liquid in the collection tube, and put the adsorption columns back into the collection tube.7. Add 500µL of Buffer GW1 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12,000rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorption column back into the collection tube.8. Add 500µL of Buffer GW2 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12000rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorption column back into the collection tube.Note: Step 8 can be repeated if further DNA purity is required.9.12 Centrifuge at 2000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Leave the adsorption column at room temperature for several minutes to dry thoroughly.Note: The purpose of this step is to remove residual ethanol from the adsorption column; ethanol residue can interfere with subsequent enzymatic reactions.10. Place the adsorption column in a new 1.5 mL collection tube, add 20-100 µL of Buffer TE or sterilized water to the middle of the adsorption column overhanging the column, let it stand at room temperature for 2-5 minutes, centrifuge it at 12,000 rpm for 1 minute, and collect the DNA solution.-20°C to preserve DNA.Note: 1) The pH value of the eluent has a great influence on the elution efficiency, if water is used as the eluent should ensure that its pH value is 7.0-8.5, the pH value is lower than 7.0 when the elution efficiency is not high.2) If the final concentration of DNA is to be increased, the DNA eluate obtained in step 10 can be re-spiked onto the adsorbent membrane and left at room temperature for 2 minutes and centrifuged at 12,000 rpm for 1 minute... Read More | Products contentProducts IntroductionThis product uses the principle that the difference between the concentration of salt ions inside and outside the cell can cause the cell membrane to burst to lyses the cell and releases the genomic DNA, without the need of extracting and purifying the genomic Products contentProducts IntroductionThis product uses the principle that the difference between the concentration of salt ions inside and outside the cell can cause the cell membrane to burst to lyses the cell and releases the genomic DNA, without the need of extracting and purifying the genomic DNA.This product is suitable for a variety of sources of samples, and can be used as a template for PCR and qPCR experiments after sample processing, and can achieve the effect of the purified DNA used as a template for PCR and qPCR experiments. Usage1. Depending on the type of sample, prepare the appropriate sample size according to the table below.2. Add the sample to a 1.5-mi centrifuge tube and add the recommended volume of Solution A as shown in the table below. Vortex for 20 s and allow to stand at room temperature for 3-5 min or incubate in a metal bath at 95°C for 3-5 min as recommended in the table below.3. After the sample has been sufficiently lysed (samples incubated in a metal bath at 95°C should be brought to room temperature), add the recommended volume of Solution B as shown in the table below and vortex for 30s.4. Store processed samples at 4°C if the next test is to be performed within 2 hours, or at -20°C if the next test cannot be performed immediately.take note of1) Depending on the requirements of the experimental conditions, the amount of samples can be expanded or reduced, and the amount of Solution A and Solution B can be increased in equal proportions.2) For blood and cell samples, the temperature of room temperature lysis is required to be around 25C. If the ambient temperature does not reach 25°, the lysis time can be extended appropriately, or the vortex shaking time can be extended to ensure that the samples are fully lysed. If there is no relevant professional instrument, the centrifuge tube can be shaken vigorously to ensure adequate lysis.3) After the tissue sample is made into tissue homogenate by adding 10 times the volume of saline, it can be processed in the same way as blood samples.4) Strictly prohibit the use of expired products, please do not mix different reagents.5) laboratory supplies should be regularly cleaned and 10% of the 84 disinfectant solution or ultraviolet lamp for anti-pollution treatment, special areas dedicated to prohibit cross use, so as to avoid contamination, the end of the test, the bench should be cleaned immediately... Read More |