| Description | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export | Inquire | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export | Product DescriptionAcetyl esterase (sialate-O-acetylesterase) is a recombinant protein from Tannerella forsythia, ATCC 43037 strain, expressed in Escherichia coli. The enzyme removes acetyl groups attached via an O- group, mainly 9-, 8- and 7-. It can be used for monitoring of diacetylation of Product DescriptionAcetyl esterase (sialate-O-acetylesterase) is a recombinant protein from Tannerella forsythia, ATCC 43037 strain, expressed in Escherichia coli. The enzyme removes acetyl groups attached via an O- group, mainly 9-, 8- and 7-. It can be used for monitoring of diacetylation of sialic acids on products such as erythropoietin (EPO).The Zyme Acetyl Esterase Kit removes 9-, 8- and 7-O-acetyl groups from released sialic acids, released glycans or glycoproteins. It is commonly used for the characterization of highly-sialylated biotherapeutics such as EPO, FSH and blood clotting factors.Molecular Weight76.3 kDContentsAcetyl esterase – PBS pH7.5 buffer containing 10 mM Tris-HClReaction Buffer – 500 mM sodium acetate pH5.5Number of SamplesSufficient for up to 50 samples.Amount of SampleUp to 10 µg glycoprotein, up to 2.5 µg released glycans and up to 1 µg free sialic acid per digestion.Suitable SamplesAcetyl esterase (sialate-O-acetylesterase) can act upon complex glycoprotein samples, such as erythropoietin (EPO), bovine submaxillary mucin and oral epithelial cell-bound glycans, and on N- and O-glycans released from a glycoprotein. Either fluorescently labelled or unlabelled glycans are suitable. It can also be used on released sialic acids.Unit DefinitionOne unit (U) of acetyl esterase is defined as the amount of enzyme required to produce 300 µmole of 4-nitrophenol and acetate in 1 minute at 30°C in a buffer containing 50 mM Tris-HCl, 140 mM NaCl, pH 8.5, from 4-nitrophenyl acetate, a chromogenic esterase substrateStorageProtect from sources of heat and light. When stored correctly, the enzyme should be stable for 24 months from date of purchase. Exposure to ambient temperatures (20 – 26°C) over 3 days does not result in a reduction of enzymatic activity.ShippingThe product should be shipped at 4°C.HandlingEnsure that any glass, plastic ware or solvents used with this item are free of environmental carbohydrates. Use powder-free gloves for all sample handling procedures and avoid contamination with environmental carbohydrate.SafetyPlease read the Safety Data Sheets (SDSs) for all chemicals used. All processes involving labelling reagents should be performed using appropriate personal safety protection – safety glasses, chemically resistant gloves (e.g. nitrile), lab coat, and when appropriate, in a laboratory fume cupboard.For research use only. Not for human or drug use ApplicationAcetyl esterase (sialate-O-acetylesterase) can be used to remove 9-, 8- and 7-O-acetyl groups from released sialic acids, released glycans or glycoproteins... Read More | Product contentU665751Component100 TStorageU665751A2×UltraSYBR One Step Buffer1.4 mL-20℃. Avoid freeze/ Thaw cycle. Protect from light.U665751BUltraSYBR One Step EnzymeMix50 µL-20℃. Avoid freeze/ Thaw cycle. Protect from light.U665751C50×High ROX50 µL-20℃. AvoidProduct contentU665751Component100 TStorageU665751A2×UltraSYBR One Step Buffer1.4 mL-20℃. Avoid freeze/ Thaw cycle. Protect from light.U665751BUltraSYBR One Step EnzymeMix50 µL-20℃. Avoid freeze/ Thaw cycle. Protect from light.U665751C50×High ROX50 µL-20℃. Avoid freeze/ Thaw cycle. Protect from light.U665751DRNase-Free Water1.5 mL-20℃. Avoid freeze/ Thaw cycle. Product Introduction This product is a specialized kit for one-step Real-Time RT-qPCR. The SYBR Green I fluorescent dye contained can bind to all double-stranded DNA, allowing this product to be used for the detection of many different target sequences without the need to synthesize specific labeling probes. Real Time RT-qPCR reaction using this product, reverse transcription and quantitative PCR are carried out in the same reaction system, there is no need to add reagents during the reaction, no need to open the cap of the tube, avoiding contamination while improving the efficiency of the experiment. The new high-efficiency reverse transcriptase RNase H is activity-deficient, which reduces the degradation of RNA in the reverse transcription reaction. The enzyme has high reverse transcription efficiency and can perform a good reverse transcription reaction on a small amount of RNA template. It has high affinity to RNA and can read through RNA templates with high GC content and complex secondary structure. New efficient hot start enzyme, the enzyme activity is closed at room temperature, thus effectively avoiding non-specific amplification caused by non-specific binding of primers and templates or primer dimerization at room temperature, which greatly improves the accuracy of fluorescence quantitative PCR reaction. The included buffer system maximizes the efficacy of both enzymes at the same time and improves efficiency. This product has high sensitivity, high specificity, wide linear range, and more accurate quantification of target genes.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used with Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument. Instruments that do not require ROX calibration (U665567) Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96 and others. Instruments that require High ROX calibration (U665751) ABI Prism 7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, and others.matters needing attention1. Before using the reagents in this kit, please mix them gently by turning them up and down to avoid foaming as much as possible, and use them after brief centrifugation.2. This product uses RNA as the template for one-step RT-PCR experiment, RNase contamination should be avoided during operation, it is recommended to operate RNA in a special area, use special instruments and consumables, the operator with a mask and disposable gloves and often change the gloves, the experiment-related consumables should be processed with 0.1% DEPC (diethyl ether of pyrocarbonate) aqueous solution at 37℃ for 12 hours and autoclaved for 30 minutes before use. Sterilize for 30 minutes before use.3. UltraSYBR One Step RT-qPCR Buffer contains SYBR Green I fluorescent dye. Avoid bright light when storing this product or preparing PCR reaction solutions.4. Repeated freezing and thawing of each reagent in this kit should be avoided; repeated freezing and thawing may degrade the product performance. This product can be stored for a long time at -20℃, protected from light. If frequent use is required in the short term, it can be stored at 2-8℃.5. This kit must use specific primers, the choice of primers can be selected according to specific experiments, the good or bad primer design directly affects the results of RT-PCR reaction, the design of primers need to consider the GC content, primer length, primer position, the secondary structure of the PCR product and other factors, it is recommended to use a professional primer design software for design.6. This product cannot be used for fluorescent quantitative PCR by the probe method.Usage1. Dissolve RNA template, primers, 2× UltraSYBR One Step Buffer, UltraSYBR One Step EnzymeMix and RNase-Free Water and set aside on ice.2. PCR reaction system:Reagents25 µl Reaction systemFinal concentration2×UltraSYBR One Step Buffer12.5 µl1×Forward Primer,10 µM0.5 µl0.2 µM¹⁾Reverse Primer,10 µM0.5 µl0.2 µM¹⁾UltraSYBR One Step EnzymeMix0.5 µl RNA TemplateX µl10 pg – 100 ng50×Low ROX or High ROX(optional)2)0.5 µl1×RNase-Free Waterup to 25 µlNote: 1) Usually, the primer concentration of 0.2µM can get better results, and the final concentration of 0.1-0.5µM can be used as a reference for setting the range. If the amplification efficiency is not high, the concentration of primer can be increased; when non-specific reaction occurs, the concentration of primer can be decreased, thus optimizing the reaction system.(2) The excitation optical system varies from instrument to instrument, choose to add 50×Low ROX or 50×High ROX according to the instrument using fluorescence quantification.3. Vortex and shake to mix, centrifuge briefly, and collect the solution at the bottom of the tube.4. RT-qPCR reaction conditions (fluorescence quantitative PCR is a two-step method), this program is based on the ABI 7500 fluorescence quantitative PCR instrument as an exampleNote: 1) It is recommended to use two-step PCR reaction program, if you improve the reaction specificity, you can increase the annealing temperature to 60-64 ℃ as a reference for the setting range; if you do not get good experimental results due to the use of primers with lower Tm values, etc., you can try to carry out three-step PCR amplification.(2) For melting curve analysis, please set up the program recommended by the fluorescence quantitative PCR instrument used, and this program is set up with the ABI 7500 fluorescence quantitative PCR instrument as a reference.RT-qPCR reaction conditions (fluorescence quantitative PCR was a three-step method):Note: 1) For three-step PCR amplification, please use the range of 56℃-64℃ as the setting reference for the annealing temperature.(2) For melting curve analysis, please set up the program recommended by the fluorescence quantitative PCR instrument you are using, this program is ABI750 fluorescent quantitative PCR instrument as a reference setting... Read More |