| Description | Product Introduction:At present, the conventional proteome sample pretreatment process has many problems, such as poor reproducibility, poor method stability, low sensitivity, being very time-consuming, and inability to be automated. To address the above issues, Aladdin has launched a new generationProduct Introduction:At present, the conventional proteome sample pretreatment process has many problems, such as poor reproducibility, poor method stability, low sensitivity, being very time-consuming, and inability to be automated. To address the above issues, Aladdin has launched a new generation of "All In One Tube" innovative products. This product is mainly designed for the processing of trace proteins (5-100µg). Even researchers without omics background can quickly prepare pretreated samples, which can be used for subsequent mass spectrometry analysis.Experimental Flowchart of Proteomics Pretreatment Kit (P1456469)Product Components and Storage Conditions:P1456469Component12 T24T48TStorageP1456469ALysis Buffer1.25 mL2.5 mL5 mL-20℃. Store in the dark.P1456469BDigest0.05 mL0.1 mL0.2 mL-20℃P1456469CBalance Buffer3 mL6 mL12 mL2-8℃P1456469DStop Buffer0.375 mL0.75 mL1.5 mLRTP1456469EWash Buffer I5 mL10 mL20 mLRTP1456469FWash Buffer II3.75 mL7.5 mL15 mLRTP1456469GWash Buffer III3.75 mL7.5 mL15 mLRTP1456469HElution Buffer6.25 mL12.5 mL25 mLRT. Store in the dark.P1456469ILoading Buffer0.25 mL0.5 mL1 mLRTP1456469JTip pillar12 T24T48TRTTrace proteins: Designed for the pretreatment of 5-100µg proteins.Simple operation: Enables rapid preparation of pretreated samples, requiring only a metal bath and a conventional centrifuge.High stability: Strict quality inspection for each batch ensures high reproducibility of experimental results.Operating Procedure:Lysis① Add 50µL of Lysis buffer to the EP tube containing the sample and mix by shaking.② Place the EP tube with Lysis buffer in a 95°C water bath for 10 minutes, then take it out and cool to room temperature.Enzymatic Digestion① Add 225µL of Balance buffer to the EP tube that has cooled to room temperature.② Add 3µL of Digest, mix well, and perform enzymatic digestion with shaking at 37°C and 1200rpm overnight (16 hours is recommended).Desalting (at room temperature)① Add 25µL of Stop buffer to the sample and vortex to mix.② Add 320µL of Wash buffer 1, shake vigorously for 3 minutes, centrifuge at 15000rpm for 3 minutes, and remove the supernatant.③ Transfer the lower layer sample into the Tip column, centrifuge at 2500rpm for 3-5 minutes until all liquid is centrifuged down. If the liquid flow rate is slow, the speed can be increased.④ Add 200µL of Wash buffer 2 (shake for 10-20 seconds before use) to the desalting column, centrifuge at 2500rpm for 3-5 minutes until all liquid is centrifuged down.⑤ Add 200µL of Wash buffer 3 to the desalting column, centrifuge at 2500rpm for 3-5 minutes until all liquid is centrifuged down.⑥ Put the desalting column into a new EP tube, add 200µL of Elution buffer to the desalting column, centrifuge at 2000rpm for 3-5 minutes until all liquid is centrifuged down.⑦ Repeat step ⑥, collect the eluates from both times, and freeze-dry them.⑧ Add 10µL of Loading buffer, vortex vigorously for 3 minutes, centrifuge at 20000g for 10 minutes, take an appropriate amount of sample, and then mass spectrometry detection can be performed. Taking the HF-X instrument as an example, 0.5-1µg of sample is sufficient for loading.Precautions:After aliquoting, Digest should be stored at -20°C.After aliquoting, Lysis Buffer should be stored at -20°C and avoid repeated freezing and thawing.This product is limited to scientific research use by professionals, and must not be used for clinical diagnosis or treatment, nor for food or drugs... Read More | Product introduction:This kit uses uniqcell lysis and heme / protein precipitation technology, combined with DNA preparation membrane to selectively adsorb DNA to achieve the purpose of purifying genomic DNA.Scope of application:Nucleic acid extraction and purification | Products B669892Component50 TStorageB669892ABuffer RCL3×260 mL2-8℃B669892BBuffer GR25 mLRTB669892CBuffer GL25 mLRTB669892DBuffer GW1 (concentrate)13 mLRTB669892EBuffer GW2 (concentrate)15 mLRTB669892FBuffer GE15 mLRTB669892GProteinase K50 mgRTB669892HProteinase K Storage Buffer5 Products B669892Component50 TStorageB669892ABuffer RCL3×260 mL2-8℃B669892BBuffer GR25 mLRTB669892CBuffer GL25 mLRTB669892DBuffer GW1 (concentrate)13 mLRTB669892EBuffer GW2 (concentrate)15 mLRTB669892FBuffer GE15 mLRTB669892GProteinase K50 mgRTB669892HProteinase K Storage Buffer5 mLRTB669892ISpin Columns DL with Collection Tubes50 setsRTProductsThis kit is suitable for the extraction of total DNA, including genomic DNA, mitochondrial DNA and viral DNA, from fresh or frozen whole blood (blood samplestreated with anticoagulants such as citrate, EDTA or heparin), plasma, serum, haematocrit brown and yellow layers, bone marrow, cell-free body fluids, etc. Theproduct can process 1-5 ml of whole blood, and can be purified to obtain sizes rangingfrom 100bp to 50kb. The purified DNA is of high yield and good quality, with maximumremoval of proteins, pigments, lipids and other inhibitory impurities, and can bedirectly used in PCR, fluorescence quantitative PCR, enzyme digestion and SouthernBlot.Self-contained reagent: anhydrous ethanol.Pre-experiment Preparation and Important Notes1. Add 5ml Proteinase K Storage Buffer to Proteinase K to dissolve it, and storeit at -20℃. Do not leave the prepared Proteinase K at room temperature for a longtime, and avoid repeated freezing and thawing to avoid affecting its activity.2. Repeated freezing and thawing of the sample should be avoided, as this may resultin smaller DNA fragments and a decrease in the amount of extracted DNA. 3.This kit can extract up to 1-5 ml of whole blood samples, if you need to extracta large number of blood samples, please use the blood genome non-column extractionkit. 4. Anhydrous ethanol should be added to Buffer GW1 and Buffer GW2 according to theinstructions on the label of the reagent bottle before first use.5. Please check Buffer GL for crystallization or precipitation before use, if thereis any crystallization or precipitation, please put it in 56℃water bath to re-dissolve.6. If the downstream experiments are sensitive to RNA contamination, 4µl of DNaseFree RNase A (100mg/ml) can be added, RNase A is not provided in the kit, and canbe ordered separately from our company if needed.7. The Buffer RCL in the kit cannot be used further after turbidity.procedure1. Add 1-5 ml of blood sample to a centrifuge tube (supplied) and add 3 times thevolume of Buffer RCL and gently vortex or invert to mix.2. Centrifuge at 3000 rpm (~900 x g) for 10 minutes and carefully aspirate thesupernatant.3. Add 400 µl Buffer GR to the precipitate and resuspend the precipitate. Note: If the downstream assay is sensitive to RNA, add 4 µl of RNase A (100 mg/ml)solution, shake for 15 seconds, and leave at room temperature for 5 minutes.4. For 1-2 ml blood sample extraction, add 40µl Proteinase K to the above solutionand mix well; for 2-5 ml blood sample extraction, add 100µl Proteinase K to theabove solution and mix well.5. Add 400 µl of Buffer GL, mix upside down 15 times, and vigorously vortex andshake for at least 1 minute. Note: Do not add Proteinase K directly to Buffer GL.6. Incubate at 70°C for 10 minutes, during which time mixing was inverted severaltimes.Note: 1) If the solution is not completely clear, add appropriate amount of Proteinase K and incubate. Extend the incubation time until the solution is completely clear. 2) The yield of DNA has been maximized by 10 minutes of incubation, and continuedprolongation of the incubation time has no effect on DNA yield or purity.7. Add 400 µl of anhydrous ethanol and mix upside down 10 times. Centrifuge brieflyto concentrate the liquid on the walls and cap to the bottom of the tube.8. Add all of the solution obtained in the previous step to the Spin Columns DL inthe collection tube. If the solution cannot be added all at once, transfer it severaltimes. centrifuge at 12,000 rpm (~13,400 x g) for 1 minute, pour off the waste liquidfrom the collection tube, and put the column back into the collection tube.9. Add 500 µl of Buffer GW1 to the adsorption column (check that anhydrous ethanolis added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquidin the collection tube, and put the adsorption column back into the collection tube.Note: It is recommended that step 9 be repeated if the sample being extracted isthe blood genome of a species such as mice or monkeys from which hemoglobin isdifficult to remove.10. Add 500 µl Buffer GW2 to the adsorption column (check that anhydrous ethanolis added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquidin the collection tube, and put the adsorption column back into the collection tube.Note: Step 10 can be repeated if further DNA purity is required.11. Centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in thecollection tube. Leave the adsorption column at room temperature for several minutesto dry thoroughly. Note: The purpose of this step is to remove residual ethanol from the adsorptioncolumn, which can interfere with subsequent enzymatic reactions (digestion, PCR,etc.)12. Place the adsorption column in a new centrifuge tube, add 50-200 µl of BufferGE or sterilized water to the middle of the adsorption column overhanging the column,leave it at room temperature for 2-5 minutes, centrifuge at 12,000 rpm for 1 minute,collect the DNA solution, and store the DNA at -20℃.Note: 1) If the downstream experiment is sensitive to pH or EDTA, you can use sterilized water for elution. The pH of the eluent has a great influence on theelution efficiency, if water is used as the eluent should ensure that its pH is7.0-8.5 (you can use NaOH to adjust the pH of the water to this range), and the elutionefficiency is not high when the pH is lower than 7.0.2) Incubation at room temperature for 5 minutes prior to centrifugation increasesyield.3) Re-elution with an additional 50-200 µl Buffer GE or sterilized water can increase the yield.4) If the final concentration of DNA is to be increased, the DNA eluate obtainedin step 12 can be re-spiked onto the adsorbent membrane and centrifuged at 12,000rpm. 1min; if the elution volume is less than 200µl, the final concentration of DNA canbe increased, but the total yield may be reduced. If the amount of DNA is less than1 µg, elution with 50 µl Buffer GE or sterilized water is recommended.5) Because DNA preserved in water is subject to acidic hydrolysis, for long-termstorage, it is recommended that it be eluted with Buffer GE and stored at -20℃... Read More | This reagent kit uses an adsorption column that can specifically bind to viral RNA and a unique buffer system, suitable for isolating viral RNA from cell-free body fluids such as serum, plasma, urine, cerebrospinal fluid, and cell culture supernatants. The viral RNA specifically binds to the siliconThis reagent kit uses an adsorption column that can specifically bind to viral RNA and a unique buffer system, suitable for isolating viral RNA from cell-free body fluids such as serum, plasma, urine, cerebrospinal fluid, and cell culture supernatants. The viral RNA specifically binds to the silicon substrate membrane, and pollutants flow through the membrane. Completely remove impurities such as proteins through two efficient washes, and then wash high-purity viral RNA with RNase free water or RNase Free Water provided by the reagent kit. The virus RNA extracted by this kit can be directly used for experiments such as RT-PCR, Real time RT-PCR, and Western blot analysis. R666005Component50 TStorageR666005ABuffer GL15 mLRTR666005BBuffer RW140 mLRTR666005CBuffer RW2(concentrate)11 mLRTR666005DProteinase K12.5 mgRTR666005EProteinase K Storage Buffer1.25 mLRTR666005FRNase-Free Water10 mLRTR666005GSpin Columns RS with Collection Tubes50 setsRTR666005HRNase-Free Centrifuge Tubes(1.5 mL)50 EART Self prepared reagent: anhydrous ethanol, 0.9% NaCl.Preparation and important precautions before the experiment1. Add 1.25 ml of Protein K Storage Buffer to Protein K to dissolve it and store at -20 ℃. The prepared Protein K should not be left at room temperature for a long time to avoid repeated freeze-thaw cycles, which may affect its activity.2. To prevent RNase pollution, attention should be paid to the following aspects:1) Use RNase free plastic products and gun heads to avoid cross contamination.2) Glassware should be dry baked at a high temperature of 180 ℃ for 4 hours before use, while plastic containers can be soaked in 0.5 M NaOH for 10 minutes, thoroughly rinsed with water, and then sterilized under high pressure.3) Prepare the solution using water without RNase.4) Operators should wear disposable masks and gloves, and change gloves frequently during the experiment.3. Serum or plasma should avoid repeated freeze-thaw cycles that may cause protein denaturation or precipitation, reduce viral titers, and thus affect the yield of extracted viral nucleic acids.4. Before the first use, anhydrous ethanol should be added to Buffer RW2 according to the instructions on the reagent bottle label.5. If buffer GL precipitates, it can be heated at 56 ℃ to dissolve and then placed at room temperature.6. All centrifugation steps should be carried out at room temperature unless otherwise specified, and all operation steps should be carried out quickly.Operation steps1. Take 200 at room temperature µ Add serum or plasma to a 1.5 ml centrifuge tube (self provided). Attention: Less than 200 µ 0.9% NaCl (provided by the customer) can be added to make up for it.2. Add 20 to the solution in the previous step µ Protein K, mix well.3. Add 200 µ L Buffer GL, vortex oscillation for 15 seconds. Note: Do not directly add Protein K to Buffer GL. 4. Incubate at 56 ℃ for 15 minutes, briefly centrifuge, and collect the solution on the tube wall to the bottom of the tube.5. Add 250 µ Anhydrous ethanol, vortex for 15 seconds, incubate at room temperature for 5 minutes, briefly centrifuge, and collect the solution from the tube wall to the bottom of the tube.6. Add all the solution obtained in step 5 to the Spin Columns RS that have been loaded into the collection tube. If it is not possible to add all the solution to the adsorption column at once, please transfer it in two batches, centrifuge at 12000 rpm (~13400 × g) for 1 minute, discard the waste liquid in the collection tube, and put the adsorption column back into the collection tube.7. Add 500 to the adsorption column µ Centrifuge at 12000 rpm for 1 minute, discard the waste liquid from the collection tube, and place the adsorption column back into the collection tube.8. Add 500 to the adsorption column µ Buffer RW2 (check if anhydrous ethanol is added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.9. Add 500 to the adsorption column µ Centrifuge anhydrous ethanol at 12000 rpm for 1 minute, discard the waste liquid from the collection tube, and place the adsorption column back into the collection tube. 10. Centrifuge at 12000 rpm for 3 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry.Attention:1) The purpose of this step is to remove residual ethanol from the adsorption column, which will affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).2) Recommended steps: Place the adsorption column into a new 1.5 ml centrifuge tube (provided), open the tube cover, and incubate in a 56 ℃ oven for 3 minutes to thoroughly dry the membrane of the adsorption column.11. Place the adsorption column in a new RNase free centrifuge tube and add 20-50 to the middle of the adsorption column in the air µ Place RNase Free Water at room temperature for 5 minutes, centrifuge at 12000 rpm for 1 minute, collect RNA solution, and store RNA at -70 ℃ to prevent degradation.Attention:1) The volume of RNase Free Water should not be less than 20 µ l. Small volume affects the recovery rate.2) If you want to increase RNA production, you can use 20-50 µ Repeat step 11 for the new RNase Free Water.3) If you want to increase the RNA concentration, you can add the obtained solution back to the adsorption column and repeat step 11... Read More | Inquire |