| Description | Annexins are a family of calcium-dependent phospholipid-binding proteins that preferentially bind phosphatidylserine (PS). Under normal physiologic conditions, PS is predominantly located in the inner leaflet of the plasma membrane. Upon initiation of apoptosis, PS loses its asymmetric distribution Annexins are a family of calcium-dependent phospholipid-binding proteins that preferentially bind phosphatidylserine (PS). Under normal physiologic conditions, PS is predominantly located in the inner leaflet of the plasma membrane. Upon initiation of apoptosis, PS loses its asymmetric distribution across the phospholipid bilayer and is translocated to the extracellular membrane leaflet marking cells as targets of phagocytosis. Once on the outer surface of the membrane, PS can be detected by fluorescently labeled Annexin V in a calcium-dependent manner. In early-stage apoptosis, the plasma membrane excludes viability dyes such as propidium iodide (PI), 7-AAD. These cells will stain with Annexin V but not a viability dye, thus distinguishing cells in early apoptosis. However, in late stage apoptosis, the cell membrane loses integrity thereby allowing Annexin V to also access PS in the interior of the cell. A viability dye can be used to resolve these late-stage apoptotic and necrotic cells (Annexin V, viability dye-positive) from the early-stage apoptotic cells (Annexin V positive, viability dye-negative). This kit is suitable for the identification and enumeration of dead cells, such as apoptotic or necrotic cells, by flow cytometry. A1456536Components20T50T100TStorageQuantity Per TestA1456536A10X Annexin V Binding Buffer5 mL10 mL20 mL2-8℃200 µL per 0.5-1.0x10⁵ cellsA1456536BAnnexin V-AF48840 µL100 µL200 µL2-8℃. Store in the dark.2 µL per 0.5-1.0x10⁵ cellsA1456536C7-AAD Staining Solution100 µL 250 µL500 µL2-8℃. Store in the dark.5 µL per 0.5-1.0x10⁵ cellsNote: The recommended number of cells to stain per test is 0.5-1.0x10⁵ cells.Precautions 1. Please try to avoid light when using to slow down the quenching of fluorescence. 2. 7-AAD Staining Solution is toxigenic and mutagenic; handle with care. 3. Due to the calcium dependence of the Annexin V:PS interaction, it is critical to avoid buffers containing EDTA or other calcium chelators during Annexin V experiments. Instruction for use 1. Dilute 10x Binding Buffer to 1x using distilled water (1 mL 10x Binding Buffer + 9 mL ddH2O). 2. Wash cells twice with cold PBS and then resuspend the desired amount of cells in Annexin V Binding Buffer at a concentration of 0.5-1.0x10⁶ cells /mL . 3. Add 2 µL Annexin V-AF488 and 5 µL 7-AAD to 100 µL of the cell suspension. 4. Add 100 µLof 1x Binding Buffer to each assay. Gently vortex the cells and incubate for 10 min at RT (25°C) in the dark. 5. Analyze by flow cytometry within 1 hr... Read More | Product contentN666081Component50 TStorageN666081ANc-Buffer A50 mL2-8℃N666081BNc-Buffer B3 mL2-8℃N666081CNc-Buffer C25 mL2-8℃N666081DProtease Inhibitor Cocktail750 µL-20℃. Avoid freeze/thaw cycle.ProductsThe Nc-Nucleus/Plasma Protein Extraction Kit is a simple and rapid Product contentN666081Component50 TStorageN666081ANc-Buffer A50 mL2-8℃N666081BNc-Buffer B3 mL2-8℃N666081CNc-Buffer C25 mL2-8℃N666081DProtease Inhibitor Cocktail750 µL-20℃. Avoid freeze/thaw cycle.ProductsThe Nc-Nucleus/Plasma Protein Extraction Kit is a simple and rapid method for extracting nucleus and plasma proteins from mammalian cells and tissues, and the extracted proteins remain biologically active. The kit first cleaves the cell membrane and releases plasma proteins using the plasma protein extraction reagent, and then centrifuges the nucleus to obtain a nucleus precipitate. Finally, the nuclear proteins are extracted by the nuclear protein extraction reagent. The extracted nuclear and plasma proteins are of high purity, effectively avoiding cross-contamination of nuclear and plasma proteins, and can be used for subsequent operations such as Western, Gel Shift, reporter gene detection and enzyme activity determination.Caveat1. If phosphorylated proteins are to be extracted, add a phosphatase inhibitor to the extraction reagent.2. All sample handling should be done on ice.3. The amount of reagents can be adjusted according to the specific experimental situation to ensure that the ratio of each reagent used is Nc-Buffer A:Nc-Buffer B:Nc-Buffer C = 100:5.5:50.4. Higher speeds can be used for centrifugation.ProcedureI Extraction of cytoplasmic and cytosolic proteins from cells1. Please remove the extraction reagents Nc-Buffer A and Nc-Buffer C for pre-cooling before protein extraction.2. Collect the cells and count them. Centrifuge to remove supernatant.3. 1×107 cells were added with 1 ml of Nc-Buffer A (added to Protease Inhibitor Cocktail at a ratio of 1:99 within 2-3 minutes prior to protein pumping), vortexed for 5 seconds to mix well, and incubated on ice for 20 minutes.Note: The characteristics of various cells are different, and the amount of Nc-Buffer A needs to be adjusted according to the characteristics of different cells. If the protein concentration is small, reduce the amount of Nc-Buffer A and subsequent Nc-Buffer B and Nc-Buffer C proportionally.4. Add 55 µl of Nc-Buffer B, vortex for 5 seconds to mix thoroughly, and incubate on ice for 1 minute.5. Centrifuge at 12,000 rpm (~13,400 x g) for 15 minutes at 4°C, collect the supernatant (as clean as possible) into a new centrifuge tube and store at -20°C (this extract is cytoplasmic protein).6. Add 500 µl of Nc-Buffer C (add Protease Inhibitor Cocktail at a ratio of 1:99 before use) to the precipitate obtained in the previous step, vortex for 5 seconds to mix thoroughly, resuspend the precipitate and incubate on ice for 40 minutes, vortexing and mixing at 10-minute intervals for about 15-30 seconds each time.7. Centrifuge at 12,000 rpm for 15 minutes at 4°C, collect the supernatant (as clean as possible) into a new centrifuge tube and store at -20°C (this extract is for cytosolic proteins).II Extraction of cytoplasmic and cytosolic proteins from tissues1. Sampling and preservation of tissues.2. Remove the extraction reagents Nc-Buffer A and Nc-Buffer C for pre-cooling before protein extraction.3. Weigh the tissue and add 1 ml of Nc-Buffer A per 100 mg of tissue (add Protease Inhibitor Cocktail 2-3 minutes before protein extraction at a ratio of 1:99), homogenize well on ice with a homogenizer, and incubate on ice for 20 minutes.Note: The characteristics of various tissues are different, and the amount of Nc-Buffer A needs to be adjusted according to different tissues. If the protein concentration is small, reduce the amount of Nc-Buffer A and subsequent Nc-Buffer B and Nc-Buffer C proportionally.4. Add 55 µl of Nc-Buffer B, vortex for 5 seconds to mix thoroughly, and place on ice for 1 minute of incubation.5. Centrifuge at 12,000 rpm for 15 minutes at 4°C, collect the supernatant (as clean as possible) into a new centrifuge tube and store at -20°C (this extract is cytoplasmic protein).6. Add 500 µl of Nc-Buffer C (add Protease Inhibitor Cocktail at a ratio of 1:99 before use) to the precipitate obtained in the previous step, vortex for 5 seconds to mix thoroughly, resuspend the precipitate and incubate on ice for 40 minutes, vortexing and mixing at 10-minute intervals at, each time for about 15-30 seconds.7. Centrifuge at 12,000 rpm for 15 minutes at 4°C, collect the supernatant (as clean as possible) into a new centrifuge tube and store at -20°C (this extract is cytosolic protein)... Read More | DescriptionPhoto KitAlysis Starter Kit enables screening of 24 micro-scale simultaneous photocatalytic reactions with consistent and reproducible photon intensity. User guide is provided in the below hyperlink.Photo KitAlysis Operating InstructionsComponents:Photo KitAlysis LED ControllerBlue LED DescriptionPhoto KitAlysis Starter Kit enables screening of 24 micro-scale simultaneous photocatalytic reactions with consistent and reproducible photon intensity. User guide is provided in the below hyperlink.Photo KitAlysis Operating InstructionsComponents:Photo KitAlysis LED ControllerBlue LED Array (470 nm)Photo KitAlysis Reaction BlockTorque screwdriverSmall screwdriver to easily remove torqued screws after reaction is completeFeatures:Designed and tested by synthetic chemists.Controller provides repeatable milliamp selection for photon intensity0-30 mA variable LED output3 different LED options: blue (470 nm, included), green (527 nm, sold separately), and white (sold separately)Non-magnetic LED baseChemically resistant LED coverPTFE coated cablingDesigned to be used withPhoto KitAlysis High-Throughput Reaction Screening Kit(sold separately).Best when used withKitAlysis Benchtop Inertion Box(sold separately)... Read More | Product contentS665868Component50 TStorageS665868ABuffer GL25 mLRTS665868BBuffer GW1 (concentrate)13 mLRTS665868CBuffer GW2 (concentrate)15 mLRTS665868DBuffer GE15 mLRTS665868EProteinase K2×1.25 mLRTS665868FSpin Columns DM with Collection Tubes50 setsRTProduct IntroductionThis kit is suitable Product contentS665868Component50 TStorageS665868ABuffer GL25 mLRTS665868BBuffer GW1 (concentrate)13 mLRTS665868CBuffer GW2 (concentrate)15 mLRTS665868DBuffer GE15 mLRTS665868EProteinase K2×1.25 mLRTS665868FSpin Columns DM with Collection Tubes50 setsRTProduct IntroductionThis kit is suitable for the extraction of genomic DNA from fresh saliva or saliva/preservation solution mixture.The purification process of this product does not require the use of toxic solvents such as phenol or chloroform, and ethanol precipitation is not necessary. The optimized buffer system enables DNA to bind heterogeneously to the silica matrix centrifugal adsorption column, and the inhibitors of PCR and other enzymatic reactions can be effectively removed by a two-step washing step, and finally eluted with a low-salt buffer or water to obtain high-purity DNA.The purified obtained can be directly used for enzyme digestion, PCR, Real-Time PCR, library construction, Southern Blot, molecular labeling and other downstream experiments.Self-contained reagent: anhydrous ethanolPre-experiment Preparation and Important Notes1. Repeated freezing and thawing of the sample should be avoided, as this may result in smaller fragments of extracted DNA and a decrease in the amount extracted.2. Anhydrous ethanol should be added to Buffer GW1 and Buffer GW2 according to the instructions on the label of the reagent bottle before first use.3. Before use, please check whether Buffer GL appears to be crystallized or precipitated.Redissolve in a 56°C water bath.4. If the downstream experiments are sensitive to RNA contamination, 4 µL DNase-Free RNase A can be added in step 3(100 mg/mL).5. For prolonged storage of salivary DNA at room temperature, our Salivary DNA Preservation Tubes are recommended.Operation steps1. Add 400 µL of saliva sample or saliva/preservation solution mixture.Note: 1) Saliva mixtures added to the preservation solution require a 50°C water bath for 1 hour or an empty 50°C temperature chamber for 2 hours prior to extraction.2) If an increase in sample volume is required, multiply the volumes of Proteinase K, Buffer GL, and anhydrous ethanol in Steps 2-4, and the liquid can be transferred in multiple times in Step 5.2. Add 40 µL of Proteinase K.3. Add 400µL Buffer GL, vortex and shake to mix thoroughly, and water bath at 56℃ for 15-30 minutes.Note: If RNA removal is required, add 4 µL of RNase A solution at a concentration of 100 mg/mL after the above steps are completed, vortex for 15 seconds, and leave at room temperature for 2 minutes.4. Centrifuge briefly to remove water droplets from the inside of the tube cap. Add 400 µL of anhydrous ethanol and mix well by vortexing and shaking. Centrifuge briefly.Note: 1) Vortex and shake to mix immediately after adding Buffer GL and anhydrous ethanol.The addition of Buffer GL and anhydrous ethanol may produce a white precipitate that will not affect subsequent experiments.2) A sol-gel product may be formed after GL and anhydrous ethanol, in which case vigorous shaking or vortexing is recommended.3) The solution obtained in the previous step is added to the adsorption column in the Collection Tube.5. (Spin Column DM) in the collection tube, and if the solution cannot be added all at once, it can be transferred in several times. centrifuge at 12,000 rpm (∼13,400 × g) for 1 min, pour off the waste solution in the collection tube, and put the adsorption column back into the collection tube.6. Add 500 µL of Buffer GW1 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorption column back into the collection tube.7. Add 500 µL of Buffer GW2 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorption column back into the collection tube.Note: Step 7 can be repeated if further DNA purity is required.8. Centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Leave the adsorption column at room temperature for several minutes to dry thoroughly.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can interfere with subsequent enzymatic reactions (digestion, PCR, etc.).9. Place the adsorption column in a new centrifuge tube (supplied), add 50-200 µL of Buffer GE or sterilized water to the middle of the adsorption column overhanging the column, let it stand at room temperature for 2-5 minutes, and centrifuge at 12,000 rpm for 1 minute to collect the DNA solution.-20°C to preserve DNA.Note: 1) If the downstream experiment is sensitive to pH or EDTA, you can use sterilized water for elution. The pH of the eluent has a great influence on the elution efficiency, if water is used as the eluent should ensure that its pH is 7.0-8.5 (you can use NaOH to adjust the pH of the water to this range), and the elution efficiency is not high when the pH is lower than 7.0.2) Buffer GE preheated in a 65-70°C water bath and incubated at room temperature for 5 min before centrifugation can increase the yield.3) Because DNA preserved in water is subject to acidic hydrolysis, for long-term storage, elution with Buffer GE and storage at -20°C is recommended... Read More | Products contentProducts IntroductionThe Single Cell Whole Genome Amplification Kit can be used as a template for whole genome amplification of single cells or micro samples. The total time for single-cell amplification is about 3 hours, and 2-5 µg of genomic DNA, with a size of 200-1500 bp, Products contentProducts IntroductionThe Single Cell Whole Genome Amplification Kit can be used as a template for whole genome amplification of single cells or micro samples. The total time for single-cell amplification is about 3 hours, and 2-5 µg of genomic DNA, with a size of 200-1500 bp, can be obtained after lysis, pre-amplification and amplification. The amplified product can be widely used in second-generation sequencing, large fragment copy number variation analysis, SNP typing, qPCR analysis and gene chip analysis.Bring your own instruments and reagentsPCR instrument Reaction tubes: low adsorption tubes recommended Gun Heads: High quality filtered gun heads are recommended Microcentrifuge, vortex mixercaveat The sensitivity of this product is very high, the experimental operation should be completed in a positive pressure ultra-clean bench or clean environment, the concentration of the amplification reaction products is high, should be well isolated to avoid aerosol contamination caused by amplification products.Operation flow diagramprocedurePre-experiment preparationSingle cells were obtained by flow cytometry sorting, buffer dilution, micromanipulation and laser microdissection. It is recommended that the cells be washed prior to the experiments with a 1× PBS solution free of Mg2+ and Ca2+, taking care to ensure that the volume of PBS solution in subsequent experiments does not exceed 2 µl. take note of Since the whole experiment is carried out in the same PCR tube and the reaction volume is small, the pipette tip should not touch the liquid in the tube when adding liquid, so as to avoid taking single cells or DNA out of the reaction system; when pipetting, please add the liquid along the wall of the tube carefully and do not blow the liquid in the PCR tube; before the reaction, please centrifuge briefly to make sure that the liquid in the reaction system is mixed evenly. Thaw the cell lysate, pre-amplifier and amplifier on ice before use.cell lysis 1)Mix Cell Lysis Buffer and Cell Lysis Enzyme according to the number of reactions N, shake to mix, centrifuge briefly and set aside.2)Mix single cells with the cell lysis mix in a PCR tube and run the following program.2. Pre-amplification reaction1)Mix Cell Lysis Buffer and Cell Lysis Enzyme according to the number of reactions N, shake to mix, centrifuge briefly and set aside.2)Add 5 µl of pre-amplification mix to 10 µl of lysis reaction product from the previous step and run the following program. 3. Amplification reaction1)Mix Amplification Buffer and Amp Enzyme Mix according to the number of reactions N, mix with shaking, centrifuge briefly and set aside.2)Add 60 µl of amplification mix to 15 µl of pre-amplification reaction product from the previous step and run the following program.Note: The number of cycles can be adjusted as needed, 14 cycles are recommended for single cells obtained by flow sorting, etc.Amplification product detection 1. Agarose gel electrophoresis 5 µl of the amplified product was subjected to agarose gel electrophoresis (1% agarose gel, 110 V, 25-35 min), and the amplified product was 200-1500 bp in size. 2. Quantitative Amplification products were subjected to magnetic bead or column purification, and purified products were quantified using Qubit with a final yield of 2-5 µg... Read More |