| Description | Inquire | Products content Box 1: Circularization reagentC666001Component16 TStorageC666001ASplint Oligo20 µL-20℃.Avoid freeze/thaw cycle. C666001B5×Splint Buffer T4250 µL-20℃.Avoid freeze/thaw cycle. C666001CDNA Ligase50 µL-20℃.Avoid freeze/thaw cycle. C666001DDigestion Products content Box 1: Circularization reagentC666001Component16 TStorageC666001ASplint Oligo20 µL-20℃.Avoid freeze/thaw cycle. C666001B5×Splint Buffer T4250 µL-20℃.Avoid freeze/thaw cycle. C666001CDNA Ligase50 µL-20℃.Avoid freeze/thaw cycle. C666001DDigestion Buffer20 µL-20℃.Avoid freeze/thaw cycle. C666001EDigestion Enzyme I70 µL-20℃.Avoid freeze/thaw cycle. C666001FDigestion Enzyme III25 µL-20℃.Avoid freeze/thaw cycle. Box 2: Magnetic Beads for DNA Purification and RecoveryC666001Component16 TStorageC666001GCMPure4×1.5 mL2-8℃Products IntroductionThe Cyclization Kit is a modular kit tailored for the MGI high-throughput sequencing platform. With this kit, PCR products after junction ligation can be prepared into single-stranded circular DNA libraries suitable for MGI sequencers. All reagents provided in the kit have been subjected to stringent quality control and functional validation to maximize the stability and reproducibility of library construction. Provide your own instruments, reagents and consumables1. Magnetic frame: DynaMagTM-2 (Cat. No. 12321D) is recommended.2. "Qubit" 3.0 Fluorescence Quantimeter (ThermoFisher, Cat. No. Q33216)3. Qubit" ssDNA Assay Kit (Invitrogen, Cat. No. Q10212)4. Anhydrous ethanol, EB (10 mM Tris-HCl, pH 8.0), NF Water (pH between 7.0 and 8.0).5. reaction tubes: low adsorption PCR tubes with 1.5 mIEP tubes are recommended: 5.Tip: It is recommended to use a high quality filter tip to prevent contamination of kits and libraries. Pre-experiment Preparation and Important Notes 1. Sample preparation.PCR product: 2330 ng total (total amount when multiple PCR products are mixed) in a volume of 49 pL (if the volume of PCR product is insufficient, add NF Water to bring the total volume to 49 pl). -PCR product: Fragment size: The fragment peak is between 200-500 bp. -PCR product fragment size: Fragment peaks between 200-500 bp. -PCR product modification: Fixed sequences (with Index) for MGISEQ-2000, MGISEQ-200 and BGISEQ-500 sequencing platforms were added.2. Reagent preparation-Remove the corresponding reagents from the kit, centrifuge briefly, and place the enzyme mixture on ice until ready to use: buffers need to be dissolved at room temperature before use, then centrifuged with shaking and placed on ice until ready to use, and NF Water and EB are placed at room temperature until ready to use: "Please make up the mixture on ice:Precipitation may appear after the buffer in the kit is dissolved, the precipitation does not affect the function of the reagent, please shake and mix well until the precipitation disappears and then use. Schematic diagram of the cyclization process procedurecyclize 1. 1 wl of Splint Oligo was added to the 49JI PCR product. The product was denatured and incubated on a PCR instrument at 95°C for 3 min, then immediately transferred to an ice bath and allowed to stand for 2 min. 2. The reaction mixture was prepared on ice according to the following system. 3. Add 15ul of the above reaction mixture to 50µl of denatured DNA.4. Place the above PCR tubes on the PCR instrument under the following conditions Reaction. digest 1. Prepare the digestion reaction solution on ice according to the following system. 2. After the cyclization reaction, add 8l of digestion reaction solution directly to the cyclization system, mix well, centrifuge briefly and then place the PCR tube on the PCR instrument and react under the following conditions. 3. Purification was carried out immediately after the reaction.Purification of digestive products1. Remove CMPure at room temperature 30 minutes prior to use and mix well with shaking.2. Transfer the digested product to a 1.5 mIEP tube, pipette 340 pICMPure into the digested product, mix well by gently blowing 10 times with a pipette and incubate for 10 minutes at room temperature.3. Instantaneous centrifugation, place the EP tube on a magnetic rack and let stand for 5 minutes until the liquid is clear, pipette and discard the supernatant.4. Keep the EP tube fixed on a magnetic rack, add 250ul of freshly prepared 80% ethanol, let it stand at room temperature for 1 minute, then carefully discard the supernatant.5. Repeat step 4 once, try to suck up the liquid at the bottom of the tube: Note: Do not suck up the magnetic beads, so as not to affect the yield.6. Keep the EP tube fixed on the magnetic rack, open the cap and dry it at room temperature for 5-10 minutes.7. Remove the EP tube from the magnetic rack, add 35ul of EB or NF Water for DNA elution, pipette blow to mix and dissolve at room temperature for 10 min.8. Centrifuge instantaneously, place the EP tube on a magnetic rack and let stand for 2 minutes until the liquid is clarified, transfer the supernatant to a new EP tube. -Store at 20C and leave to prepare DNB... Read More | Product content C665709Component50 TStorageC665709ABuffer CL45 mLRTC665709BBuffer CB (concentrate)60 mLRTC665709CBuffer GW1 (concentrate)13 mLRTC665709DBuffer GW2 (concentrate)15 mLRTC665709EBuffer EBL10 mLRTC665709FProteinase K100 mgRTC665709GProteinase K Storage Buffer5 mLRTC665709HSpin Columns DFProduct content C665709Component50 TStorageC665709ABuffer CL45 mLRTC665709BBuffer CB (concentrate)60 mLRTC665709CBuffer GW1 (concentrate)13 mLRTC665709DBuffer GW2 (concentrate)15 mLRTC665709EBuffer EBL10 mLRTC665709FProteinase K100 mgRTC665709GProteinase K Storage Buffer5 mLRTC665709HSpin Columns DF with Collection Tubes50 EA2-8℃C665709ICentrifuge Tubes (L-1.5 mL)50 EART Product IntroductionThis kit is suitable for the extraction of free DNA from fresh or frozen serum, plasma, lymph fluid and other cell-free body fluids.This kit adopts centrifugal adsorption columns that can specifically bind nucleic acids and a unique buffer system.After the sample is lysed, the free DNA binds to the silica gel membrane under high salt conditions, and the free DNA elutes from the silica gel membrane at low salt and high pH. The product can handle liquid samples of 0.1-1 ml, and the elution volume of the configured high-efficiency micro adsorption column can be as low as 20 µl. The purified DNA is of high yield and quality, with maximum removal of proteins, pigments, lipids, and other inhibitors, and the rate of free DNA yield is highly dependent on the type of samples, storage conditions, time, and inter-individual variations. The quality of free DNA obtained from purification is stable and reliable, and can be directly used in molecular biology experiments such as PCR, fluorescence quantitative PCR and second generation sequencing.Self-contained reagents: anhydrous ethanol, isopropanol.Pre-experiment Preparation and Important NotesAdd 5 ml of Proteinase K Storage Buffer to Proteinase K to dissolve it and store it at -20℃. Do not leave the prepared Proteinase K at room temperature for a long time.Repeated freezing and thawing of the sample should be avoided, as this can lead to a decrease in extraction.This kit can extract 0.1-1 ml of liquid samples.Before use, please check Buffer CL, Buffer CB for crystallization or precipitation, if there is any crystallization or precipitation, please re-dissolve Buffer CL, Buffer CB by incubation at 56℃ in a water bath.Before first use isopropyl alcohol should be added to Buffer CB according to the instructions on the reagent bottle label, mixed well, and labeled on the reagent bottle label.Before the first use, anhydrous ethanol should be added to Buffer GW1 and Buffer GW2 according to the instructions on the label of the reagent bottle, mixed well, and labeled on the label of the reagent bottle.Preheat the water bath to 60°C before starting the experiment.The elution buffer Buffer EBL can be preheated to 60°C and used.Operation stepsAdd 20 µl of Proteinase K to the centrifuge tube (supplied).Add 200 µl of serum/plasma sample.Note: When the sample volume exceeds 200 µl, please increase the amount of Proteinase K, Buffer CL and Buffer CB reagents in equal proportions, and the specific amount of reagents added can be referred to the attached table.3. Add 160 µl Buffer CL, mix upside down and shake vigorously for at least 30 seconds.4. Incubate at 60°C for 30 minutes, during which time mixing was inverted several times.Note: Incubation of 200µl serum/plasma samples at 60°C for 10-15 minutes is sufficient.Add 360 µl of Buffer CB (check for addition of isopropanol before use) and shake until thoroughly mixed.Ice bath for 5 minutes and centrifuge briefly to concentrate the liquid on the walls and wall caps to the bottom of the tube.Add all of the solution obtained in step 6 to the adsorption columns (Spin Columns DF) that have been loaded into the collection tubes, and if the solution cannot be added all at once, it can be transferred in several times. centrifuge the columns at 12,000 rpm for 1 minute, pour off the waste solution from the collection tubes, and put the columns back into the collection tubes.Add 500µl of Buffer GW1 to the adsorbent column (check that anhydrous ethanol is added before use),centrifuge the column at 12,000rpm for 30 seconds, pour off the waste liquid in the collection tube, and put the adsorbent column back into the collection tube.Add 750 µl Buffer GW2 to the adsorbent column (check that anhydrous ethanol is added before use), centrifuge at 12,000 rpm for 30 seconds, pour off the waste liquid in the collection tube, and put the adsorbent column back into the collection tube.10. Add 750 µl of anhydrous ethanol to the adsorbent column and centrifuge at 12,000 rpm for 30 s. Pour off the waste liquid in the collection tube and put the adsorbent column back into the collection tube.11. Centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Leave the adsorption column at room temperature for several minutes to dry thoroughly.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can interfere with the subsequent enzymatic reaction.12. Place the adsorption column in a new centrifuge tube, add 20-100 µl Buffer EBL or sterilized water to the middle part of the adsorption column overhanging the column, leave it at room temperature for 2-5 minutes, centrifuge at 12,000 rpm for 1 minute, collect the DNA solution, and store the DNA at -20℃.Note: 1) If the downstream experiment is sensitive to pH, you can use sterilized water for elution. The pH value of the eluent has a great influence on the elution efficiency, if water is used as the eluent should ensure that its pH value is 7.0-8.5 (you can use NaOH to adjust the pH value of water to this range), and the elution efficiency is not high when the pH value is lower than 7.0.2) Preheat the elution buffer BufferEBL to 60℃ and use it, and incubate it at room temperature for 5 minutes before centrifugation to increase the yield.3) If the final concentration of DNA is to be increased, the resulting solution can be reintroduced into the adsorption column and left at room temperature for 2-5 minutes and centrifuged at 12,000 rpm for 1 minute.4) Because DNA preserved in water will be affected by acidic hydrolysis, for long-term storage, it is recommended to elute it with Buffer EBL and store it at -20℃.Table: Recommended reagent additions for different sample sizes... Read More | Product content:D665967Component200 TStorageD665967ABuffer PB120 mLRTD665967BBuffer PS60 mLRTD665967CBuffer PW (concentrate)25 mLRTD665967DBuffer EB30 mLRTD665967ESpin Columns DM with Collection Tubes200 EART Product Introduction: This reagent kit adopts a new silicon-based membrane technology and Product content:D665967Component200 TStorageD665967ABuffer PB120 mLRTD665967BBuffer PS60 mLRTD665967CBuffer PW (concentrate)25 mLRTD665967DBuffer EB30 mLRTD665967ESpin Columns DM with Collection Tubes200 EART Product Introduction: This reagent kit adopts a new silicon-based membrane technology and reagent formula. Through a rapid and simple three-step process of binding, washing, and elution, 100 bp-10 kb DNA fragments can be purified and recovered from PCR products or enzyme reaction solutions (enzyme cutting, linking, probe labeling, etc.). Each adsorption column can adsorb up to 10 kb of DNA fragments µ G DNA, while minimizing impurities such as primers, oligonucleotides, enzymes, etc. The purified and recovered DNA has high purity and concentration, good integrity, and high recovery rate, and can be directly used for molecular biology experiments such as sequencing, linking and transformation, labeling, and in vitro transcription.Self prepared reagent: anhydrous ethanol.Preparation and important precautions before the experiment:1. All components can be stably stored in a dry, room temperature (15-30 ℃) environment for 1 year, and can be stored at 2-8 ℃ for longer periods of time. When the solution is stored at low temperature, it should be left at room temperature for a period of time before use, and then restored to room temperature before use.2. This reagent kit can selectively recover all DNA fragments from the solution. If you need to selectively recover specific fragments while removing other fragments of different sizes, please choose our company's gel recovery reagent kit.3.Before the first use, anhydrous ethanol should be added to the Buffer PW according to the instructions on the reagent bottle label.4. Before use, please check if there is any crystallization or precipitation in the Buffer PB. If there is any crystallization or precipitation, you can take a water bath at 37 ℃ for a few minutes to restore clarity.5. The recovery efficiency is related to the initial amount of DNA and the elution volume. The smaller the initial amount, the smaller the elution volume, and the lower the recovery rate.6. All centrifugation steps can be performed at room temperature.Operation steps:1. Estimate the volume of DNA reaction solution, add 5 times the volume of Buffer PB, and mix thoroughly (without removing paraffin or mineral oil).Note: 1) If the DNA reaction system is 50 µ l (excluding paraffin oil volume), add 250 µ l Buffer PB.2) After adding Buffer PB, check the pH value of the solution. If the pH value is greater than 7.5, add 10-30 to it µ 3 M sodium acetate (pH 5.0) was used to adjust the pH value to 5-7.2. Column balance: Add 200 to the spin columns DM that have been loaded into the collection tube µ Centrifuge at 13000 rpm (~16200 × g) for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.3. Add the solution obtained in step 1 to the adsorption column that has been loaded into the collection tube, let it stand at room temperature for 1 minute, centrifuge at 13000 rpm for 30-60 seconds, discard the waste liquid in the collection tube, and place the adsorption column in the collection tube.Attention: The volume of the adsorption column is 750 µ l. If the sample volume is greater than 750 µ l, it can be added in batches.4. Add 500 µ l of Buffer PW to the adsorption column (please check if anhydrous ethanol has been added before use), centrifuge at 13000 rpm for 30-60 seconds, discard the waste liquid in the collection tube, and place the adsorption column in the recovery tube.Note: If purified DNA is used for salt sensitivity experiments (such as flat end ligation experiments or direct sequencing), it is recommended to add Buffer PW and let it stand for 2-5 minutes before centrifugation.5.13000 rpm for 1 minute and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.). To ensure that downstream experiments are not affected by residual ethanol, it is recommended to open the cover of the adsorption column and place it at room temperature for a few minutes to thoroughly dry the residual ethanol in the adsorbent material at the bottom.6. Place the adsorption column into a new centrifuge tube (provided by oneself), add 30-50 µ l Buffer EB to the middle position of the adsorption membrane by hanging droplets, and let it stand at room temperature for 1 minute. Centrifuge at 13000 rpm for 1 minute and collect DNA solution- Store DNA at 20 ℃.Attention:1) The pH value of the eluent has a significant impact on the elution efficiency. If water is used as the eluent, its pH value should be ensured to be between 7.0-8.5 (the pH value of water can be adjusted to this range using NaOH).2) To improve the recovery of DNA, the solution obtained by centrifugation can be added back to the adsorption column, left at room temperature for 2 minutes, and centrifuged at 13000 rpm for 1 minute.3) The elution volume should not be less than 30 µ l. A small volume will affect the recovery efficiency... Read More | Product Characteristics Effect Diluents, Animal-free are effective buffers free of any animal components. They can be used for the dilution of serum, plasma, blood, stool or urine samples, as well as the dilution of primary and secondary antibodies. Effect Diluents, Animal-free efficiently minimize Product Characteristics Effect Diluents, Animal-free are effective buffers free of any animal components. They can be used for the dilution of serum, plasma, blood, stool or urine samples, as well as the dilution of primary and secondary antibodies. Effect Diluents, Animal-free efficiently minimize matrix effects, cross-reactions and unspecific binding in immunoassays like ELISA, Western blotting, Immunohistochemistry, protein arrays and immuno-PCR.The Effect Diluents, Animal-free are used alternatively to the standard sample or antibody dilution buffers: In ELISA for the dilution of specimen and detection antibodies. In Western Blotting for the dilution of primary and secondary antibodies. In Protein arrays for the dilution of specimen and detection antibodies. In immuno-PCR as a washing buffer.Three versions of the diluent are offered: Low, Medium and High for optimal discrimination between specific and unspecific reaction and for minimizing strong interference effects e.g., by RF (rheumatoid factors), HAMAs (human-a-mouse Abs) or by endogenous components that bind and mask the analyte.Composition & Properties The Effect Diluents, Animal free contain no animal components and are free of phosphates.Working Procedure 1.Mix thoroughly prior to use. 2.Dilution recommendations a.Dilute antibodies according to the instruction of the antibody b.Dilution of the specimen is recommended at 1:2 or higherTips & TricksEffect Diluents must not be considered as blocking buffers. Recommended blocking buffers are: Synthetic Blocking Buffer, ELISA (cat. no. S494401), Synthetic Blocking Buffer, Blotting (cat. no. S494457) and WellChampion (cat. no. W494467) for plate blocking and stabilization (preparation of pre-coated plates). Complex sample matrices, such as serum and plasma, may contain interfering factors that affect the ability of the assay to accurately quantify the target analyte. Strong interferences are often caused by RFs and HAMAs. This matrix effect can cause high background in the negative control or false negatives in the sample measurement. To reduce this effect the samples can be diluted in the Effect Diluents, Animalfree.Handling & Storage Store solution 2-8°C or -15 to -30°C (tolerates freezing and thawing cycles)... Read More |