| Description | Inquire | Cell proliferation detection is a basic experimental method to evaluate the health of cells, genotoxicity and the effect of antitumor drugs. The most accurate method to detect cell proliferation is the BrdU method. Edu detection kit is a revolutionary breakthrough of BrdU method. Edu (5-Cell proliferation detection is a basic experimental method to evaluate the health of cells, genotoxicity and the effect of antitumor drugs. The most accurate method to detect cell proliferation is the BrdU method. Edu detection kit is a revolutionary breakthrough of BrdU method. Edu (5-ethynyl-2 '- deoxyuridine) is a pyrimidine analog that integrates into the DNA duplex during DNA synthesis. Edu detection is based on the "click" reaction. A copper catalyzed azide reacts covalently with alkynes to form covalent bonds. In this kit, edu contains alkynes, Aladdin ® 488 / 555/594/647a azide dyes contain azide compounds. The edu labeling proliferation of click method is rapid and effective, and easy to use. BrdU method requires DNA denaturation (such as acid denaturation, thermal denaturation or digestion with DNase) to expose BrdU, so as to facilitate BrdU antibody binding; The edu method only needs paraformaldehyde fixation and Triton X-100 penetration to make the detection reagent enter the cells, and only a small amount of azide dye is needed to label the integrated edu very effectively. This kit contains all components required for edu method detection, and can be used for proliferation detection of cultured cells in vitro.Component:Product parameters:555/565 nm;Instruction: Experimental materials (self provided). 10 mM PBS, pH 7.2-7.6. 4% paraformaldehyde fixing solution (in PBS)Propensive reagent (0.5% Triton X -100 in PBS). 2 mg/mL glycine solution (in ddH2O). 3% BSA in PBS, pH 7.2-7.6. 1% BSA in PBS, pH 7.2-7.6. ddH2O. 96/24/12/6 well culture plate or dishFluorescence microscopy detection method1. Cell cultureTake logarithmic growth stage cells and inoculate them into a 96 well plate with 4 × 103-1 × 105 cells per well (the number and density of cells can be adjusted according to cell size, growth rate, and specific requirements of experimental treatment), and culture until normal growth stage.2. Drug treatmentPerform various drug treatments according to experimental needs.3. EdU marking(1) Dilute EdU solution (component A) in a certain proportion with complete cell culture medium to an appropriate concentration, then add it to the cells and mix well; Set up a negative control group without EdU treatment.Note: The labeling concentration of EdU needs to be adjusted according to cell type, and it is recommended to explore with an initial concentration of 10 µ M. In the pre experiment, it is recommended to set an EdU concentration gradient, which can be referred to in Tables 2 and 3.(2) Incubate in a cell culture incubator for 2 hours.Note: The optimal incubation time is related to the cell cycle. Most tumor cell lines can use a 2-hour incubation time, as shown in Appendix 2. The concentration of EdU is related to the incubation time, and high concentrations, such as 10-50, should be used for short-term incubation (<2 hours) µ M; Long term incubation (>24 hours) should use low concentrations, such as 1-10 µ M; You can also refer to Appendix 3.4. Cell fixation and permeation promotionNote: For experiments that require cell surface antigen labeling, it can be considered to wash the cells twice with a 3% BSA washing solution after completing EdU incubation, before cell fixation and permeation promotion.(1) After incubation, remove the culture medium. Wash cells twice with 1X PBS for 5 minutes each time to remove EdU residues that have not been incorporated into DNA. Cells with weak adhesion can reduce cleaning intensity. Join 50 µ After incubating at room temperature for 20 minutes with 4% paraformaldehyde fixative, remove the fixative.(2) Add 50 to each hole µ L 2 mg/mL glycine solution, incubate at room temperature for 5 minutes, and neutralize the remaining fixed solution.(3) At a rate of 100 per hole µ Wash cells twice with 3% BSA.(4) Remove the washing solution and add 100 µ L 0.5% Triton X -100, incubate at room temperature for 10 minutes.5. EdU detectionNote: Each sample in this reference step uses 100 µ The working fluid of L can be adjusted by users according to their own sample situation.(1) Prepare 1 x Click iT EdU reaction buffer (component C): Dilute component C 10 times with ddH2O.(2) Configure 5 x Click iT EdU buffer additives (component E): add 300 µ Mix L of ddH2O into a 30 mg E component tube (final concentration of 100 mg/mL) until completely dissolved. After use, the remaining storage solution is stored at -20 ℃ and can be stored for one year. Once the solution turns brown, it indicates that the active ingredients have degraded and cannot be reused.Note: Different specifications of component E are dissolved in ddH2O according to this ratio, and prepared into a 5 x storage solution for future use.(3) Prepare 1 x Click iT EdU buffer additive: Dilute 5 x Click iT EdU buffer additive with ddH2O to 1 x, and the solution should be prepared and used immediately.(4) Prepare Click it working solution according to Table 1.Table 1 Click it working fluidReaction componentsTaking the sample size of 10 holes as an example1×Click-iT EdU Reaction buffer855 µLCuSO4 (Component D)40 µLYF® 488/555/594/647A Azide(Component B)5 µL1×Click-iT EdU Buffer additives100 µLTotal volume1 mL(5) Remove penetration enhancer, 100 per well µ Wash twice with 3% BSA washing solution of L.(6) Add 100 to each hole µ L Click iT working solution, evenly covering cells.(7) Incubate at room temperature in dark for 30 minutes.(8) Remove Click-iT working fluid and add 100 µ After washing cells twice with 3% BSA, remove the washing solution and add 100 µ L PBS keeps cells moist. If there are no other special requirements, photography analysis can be carried out.6. DNA re staining (optional)(1) Using 100 µ Wash the cells once with PBS and remove the washing solution.(2) Dilute Hoechst 33342 (component F) 2000 times with PBS.(3) Add 100 to each hole µ Incubate L 1 x Hoechst 33342 solution at room temperature in dark for 15-30 minutes.(4) Remove Hoechst 33342 solution and use 100 µ Wash cells twice with PBS.7. Imaging and analysisIt is recommended to take fluorescence microscopy photos immediately after staining is completed for observation; If conditions permit, please store in a dark and moist environment at 4 ° C for 3 days before taking photos. Flow cytometry detection method1. Cell cultureInoculate 1 × 105~3 × 106 cells per well into a 6-well plate.2. Drug treatmentPerform various drug treatments according to experimental needs.3. EdU labeled cells(1) Dilute EdU solution (component A) in a certain proportion with complete cell culture medium to an appropriate concentration, then add it to the cells and mix well; Set up a negative control group without EdU treatment.Note: The labeling concentration of EdU needs to be adjusted according to cell type, and it is recommended to explore with an initial concentration of 10 µ M. In the pre experiment, it is recommended to set an EdU concentration gradient, which can be referred to in Tables 2 and 3.(2) Incubate in a cell culture incubator for 2 hours. The time of EdU incubation of cells can be directly used as an indicator for measuring cell DNA synthesis, and the choice of time point and incubation time depend on the cell growth rate. Pulse labeled cells incubated with brief EdU can be used to study cell cycle dynamics.Note: The optimal incubation time is related to the cell cycle. Most tumor cell lines can use a 2-hour incubation time, as shown in Appendix 2. The concentration of EdU is related to the incubation time, and high concentrations such as 10-50 should be used for short-term incubation (<2 hours) µ M; Long term incubation (>24 hours) should use low concentrations, such as 1-10 µ M; You can also refer to Appendix 3.4. Cell fixation and permeation promotionNote: For experiments that require cell surface antigen labeling, it can be considered to wash cells twice with 1% BSA after completing EdU incubation, before cell fixation and permeation promotion.(1) After incubation, collect cells, add 1 mL of PBS to each tube to clean the cells, centrifuge at 1000 rpm for 5 minutes, and discard the supernatant to remove EdU residue that has not been added to DNA.(2) Add 1 mL of 4% paraformaldehyde fixative to each tube to resuspend cells.(3) Incubate at room temperature for 20 minutes, centrifuge at 1000 rpm for 5 minutes, and discard the supernatant.(4) Add 1 mL of 2 mg/mL glycine to each tube and incubate for 5 minutes. Neutralize the remaining fixed solution, centrifuge at 1000 rpm for 5 minutes, and discard the supernatant. Add 1 mL of PBS to each tube for cleaning once, centrifuge at 1000 rpm for 5 minutes, and discard the supernatant.(5) Add 1mL of 0.5% Triton X-100 osmotic enhancer to each tube and resuspend cells. Incubate at room temperature for 10 minutes.5. EdU detectionNote: For 6-well plate samples, reference can be made to 1 mL of working solution per well. Users can adjust the dosage according to their own sample situation.(1) Prepare 1 x Click iT EdU reaction buffer: Dilute component C 10 times with ddH2O.(2) Prepare 5 x Click iT EdU buffer additives (component E): Add 300 µ L ddH2O to 30 mg of component E in a test tube (final concentration 100 mg/mL), mix well until completely dissolved. After use, the remaining storage solution is stored at -20 ℃ and can be stored for one year. Once the solution turns brown, it indicates that the active ingredients have degraded and cannot be reused.Note: Different specifications of component E are dissolved in ddH2O according to this ratio to form 5 x storage solution for future use.(3) Prepare 1 x Click iT EdU buffer additive: Dilute 5 x Click iT EdU buffer additive storage solution with ddH2O to 1 x, and the solution should be prepared and used immediately.(4) Prepare Click it working solution according to Table 2.Table 2 Click it working fluidReaction componentsVolume of liquid required for a single reaction1×Click-iT EdU Reaction buffer875 µLCuSO4 (Component D)20 µLYF® 488/555/594/647A Azide(Component B)5 µL1×Click-iT EdU Buffer additives100 µLTotal volume1 mL(5) Soak at 1000 rpm for 5 minutes, discard the supernatant, remove the enhancer, add 1mL of 1% BSA washing solution to each tube and wash twice. Soak at 1000 rpm for 5 minutes, discard the supernatant.(6) Add 1 mL of Click iT working solution to each tube and mix well.(7) Incubate at room temperature in dark for 30 minutes.(8) Soak at 1000 rpm for 5 minutes, discard the staining reaction solution, add 1% BSA to each tube to wash the cells twice, centrifuge at 1000 rpm for 5 minutes, discard the supernatant, and resuspend the cells again with 1 mL of 1% BSA (the volume of resuspend cells can be adjusted according to the number of cells), and detect with a flow cytometer.Note: If other biomarker tests are required, please refer to step 4.6. Intracellular antigen labeling (optional steps)(1) Add antibody working solution and mix well.(2) Under dark conditions, incubate antibodies at appropriate temperature and time.7. Flow detection and analysis:(1) It is recommended to conduct flow cytometry testing immediately after dyeing is completed; If conditions are limited, please store in a dark place at 4 ℃ for testing, but it should not exceed 3 days.(2) It is recommended to test the number of cells up to one million levels as much as possible. If the number of cells is small, the number of cells tested can be adjusted to 100000 levels starting from the experiment. For cases where the cell yield is too low (just to the level of ten thousand), it may not be conducive to making a flow chart. Therefore, the cleaning frequency in step 5 (8) can be appropriately reduced.Matters needing attention:1. please centrifuge the product to the bottom of the tube immediately before use, and then conduct subsequent experiments. 2. fluorescent dyes have quenching problems. Please try to avoid light during experimental operation to slow down fluorescence quenching. 3. click it edu buffer additive solution should be prepared and used immediately to ensure the best results. 4. for your safety and health, please wear experimental clothes and disposable gloves.Scope of application:Cell proliferation detection (cell imaging flow universal)... Read More | B669951 Component 50T Storage B669951A Buffer ATL 15 mL RT B669951B Buffer AL 15 mL RT B669951C Buffer AW1 (concentrate) 13 mL RT B669951D Buffer AW2 (concentrate) 15 mL RT B669951E Buffer EB 15 mL RT B669951F Proteinase K 1.25 mL RT B669951G Spin Columns DM with Collection Tubes 50 sets B669951 Component 50T Storage B669951A Buffer ATL 15 mL RT B669951B Buffer AL 15 mL RT B669951C Buffer AW1 (concentrate) 13 mL RT B669951D Buffer AW2 (concentrate) 15 mL RT B669951E Buffer EB 15 mL RT B669951F Proteinase K 1.25 mL RT B669951G Spin Columns DM with Collection Tubes 50 sets RTProductsThis kit is suitable for extracting high purity total DNA from Gram-negative and Gram-positive bacteria. 106-108 cells can be processed at a time, and up to 20 µg of total DNA can be obtained within one hour without the need for toxic solvents such as phenol or chloroform, and without the need for ethanol precipitation. The optimized buffer system enables the DNA in the lysate to be efficiently and specifically bound to the silica matrix centrifugal adsorption column, while other contaminants can flow through the membrane, and the inhibitors of PCR and other enzymatic reactions can be effectively removed through a two-step washing step, and finally washed off with low-salt buffer or water, so that high-purity DNA can be obtained.The purified DNA can be used for downstream experiments such as digestion, PCR, Real-Time PCR, library construction, Southern Blot and molecular labeling, molecular labeling and other downstream experiments. Self-contained reagents: anhydrous ethanol; Enzymatic Lysis Buffer is required for extraction of Gram-positive bacteria.Enzymatic Lysis Buffer was prepared by 20 mM Tris, pH 8.0; 2 mM Na2-EDTA, pH 8.0; and 1.2% Triton X-100. 121°C sterilization for 20 minutes, and the appropriate amount of Lysozyme was added at a final concentration of 20 mg/ml. Pre-experiment Preparation and Important Notes1. Add 1.25ml Proteinase K Storage Buffer to Proteinase K to dissolve it and store it at -20℃. Do not leave the prepared Proteinase K at room temperature for a long time, and avoid repeated freezing and thawing to avoid affecting its activity.2. Repeated freezing and thawing of the sample should be avoided, as this may result in smaller DNA fragments and a decrease in the amount of extracted DNA.3. If extracting genomes from bacterial cultures with high accumulation of secondary metabolites or thick cell walls, it is recommended that samples be collected early in the logarithmic phase.4. Anhydrous ethanol should be added to Buffer GW1 and Buffer GW2 according to the instructions on the label of the reagent bottle before first use.5. Before use, please check Buffer GTL and Buffer GL for crystallization or precipitation. If crystallization or precipitation occurs, please re-dissolve Buffer GL and Buffer GTL in a 56℃ water bath.6. If the downstream experiments are sensitive to RNA contamination, 4µl of DNase-Free RNase A (100mg/ml) can be added before adding Buffer GL. RNase A is not provided in this kit.If the extracted samples are Gram-positive bacteria, customers need to prepare their own Enzymatic Lysis Buffer to treat the bacteria, which requires the use of Lysozyme (lysozyme) at a concentration of 20 mg/ml, which is not provided in this kit.Procedurei Extraction of genomic DNA from Gram-negative bacteria1. Take 1-5 ml of bacterial culture (106-108 cells, maximum 2×109 cells) and put it into a centrifuge tube (provided), centrifuge it at 12,000 rpm (~13,400×g) for 1 minute, and aspirate the supernatant as much as possible.2. Add 180 µl Buffer GTL to the precipitate and shake to resuspend the bacteria.3. Add 20 µl of Proteinase K, vortex and mix well, incubate at 56°C until the solution becomes clear, and invert or shake the centrifuge tube at intervals during the incubation to disperse the sample.Note: If RNA removal is required, add 4 µl of RNase A solution at a concentration of 100 mg/ml after the above steps are completed, shake to mix, and leave for 5-10 minutes at room temperature.4. Add 200µl Buffer GL and mix well with vortexing and shaking. Add 200µl of anhydrous ethanol and mix well with vortexing and shaking.Centrifuge briefly so that the solution on the walls of the tube collects at the bottom.Note: 1) If multiple samples are manipulated together, Buffer GL and anhydrous ethanol can be mixed in equal proportions and then added together, shaking to mix.2) The addition of Buffer GL and anhydrous ethanol may produce a white precipitate that will not affect subsequent experiments.5. Add all of the solution obtained in step 4 (including the precipitate formed) to the Spin Columns DM in the collection tube, or if the solution cannot be added all at once, transfer it several times. centrifuge at 12,000 rpm for 1 minute, discard the waste solution, and return the column to the collection tube.6. Add 500 µl of Buffer GW1 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and return the adsorption column to the collection tube.7. Add 500 µl of Buffer GW2 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorption column back into the collection tube.Note: Step 7 can be repeated if further DNA purity is required.8. Centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Leave the adsorbent column at room temperature for several minutes to dry thoroughly. Note: The purpose of this step is to remove residual ethanol from the adsorbent column; ethanol residue can interfere with subsequent enzymatic reactions (digestion, PCR, etc.).9. Place the adsorption column in a new centrifuge tube, add 50-200 µl Buffer GE to the middle part of the adsorption column overhanging the center of the adsorption column, leave it at room temperature for 2-5 minutes, centrifuge it at 12,000 rpm for 1 minute, collect the DNA solution, and store the DNA at -20 ℃. note: 1) If the downstream experiments are sensitive to the pH or EDTA, the elution can be done with sterilized water. The pH of the elution solution has a great influence on the elution efficiency. If water is used as the elution solution it should be ensured that its pH is 7.0-8.5 (the pH of water can be adjusted to this range with NaOH), and the elution efficiency is not high when the pH is lower than 7.0.2) Incubation at room temperature for 5 minutes prior to centrifugation increases yield.3) Re-elution with an additional 50-200 µl Buffer GE or sterilized water can increase the yield.4) If the final concentration of DNA is to be increased, the DNA eluate obtained in step 9 can be re-spiked onto the adsorbent membrane and step 9 repeated; if the elution volume is less than 200 µl, the final concentration of DNA can be increased, but the total yield may be reduced. If the amount of DNA is less than 1 µg, elution with 50 µl Buffer GE or sterilized water is recommended.(5) DNA stored in water will be affected by acidic hydrolysis. For long-term storage, it is recommended to elute with Buffer GE and store at -20℃.i. Extraction of genomic DNA from Gram-positive bacteria1. Take 1-5 ml of bacterial culture (106-108 cells, maximum 2×109 cells) and put it into a centrifuge tube (provided), centrifuge it at 12,000 rpm (~13,400×g) for 1 minute, and aspirate the supernatant as much as possible.2. Add 180µl Enzymatic Lysis Buffer (self-provided) to resuspend the bacteria.Enzymatic Lysis Buffer is prepared as described in the Self-Prepared Reagents section in the front of the manual.3. Incubate at 37°C for 30 minutes.4. Add 20µl Proteinase K and mix well. Add 200µl of Buffer GL and mix well with vortexing and shaking.Note: Do not add Proteinase K directly to Buffer GL.Incubate at 5.56°C for 30 minutes.Note: 1) If desired, incubation at 95°C for 15 minutes will inactivate the pathogen, but 95°C incubation will cause some DNA degradation.(2) If RNA removal is required, add 4µl of RNase A solution at a concentration of 100mg/ml after the above steps are completed, shake and mix well, and leave for 5-10 minutes at room temperature.6. Add 200µl of anhydrous ethanol and mix well with vortex shaking.Note: The addition of anhydrous ethanol may produce a white precipitate that will not affect subsequent experiments.7. Add all of the solution obtained in step 6 (including the precipitate formed) to the Spin Columns DM that have been loaded into the collection tube, and if the solution cannot be added all at once, it can be transferred in several times. centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid from the collection tube, and put the column back into the collection tube.8. Add 500 µl of Buffer GW1 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorption column back into the collection tube.9. Add 500 µl Buffer GW2 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge the column at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the column back into the collection tube.Note: Step 9 can be repeated if further DNA purity is required.10. Centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Leave the adsorption column at room temperature for several minutes to dry thoroughly.Note: The purpose of this step is to remove residual ethanol from the adsorption column; ethanol residue can interfere with subsequent enzymatic reactions (digestion, PCR, etc.).11. Place the adsorption column in a new centrifuge tube (self-provided), add 50-200 µl of Buffer GE to the center of the adsorption column overhanging the center of the adsorption column, let it stand at room temperature for 2-5 minutes, centrifuge at 12,000 rpm for 1 minute, collect the DNA solution, and store the DNA at -20℃.Note: 1) If the downstream experiment is sensitive to pH or EDTA, you can use sterilized water for elution. The pH of the eluent has a great influence on the elution efficiency, if water is used as the eluent should ensure that its pH is 7.0-8.5 (you can use NaOH to adjust the pH of the water to this range), and the elution efficiency is not high when the pH is lower than 7.0.2) Incubation at room temperature for 5 minutes prior to centrifugation increases yield.3) Re-elution with an additional 50-200 µl Buffer GE or sterilized water can increase the yield.4) If the final concentration of DNA is to be increased, the DNA eluate obtained in step 11 can be re-spiked onto the adsorbent membrane and step 11 repeated; if the elution volume is less than 200 µl, the final concentration of DNA can be increased, but the total yield may be reduced. If the amount of DNA is less than 1 µg, elution with 50 µl Buffer GE or sterilized water is recommended.(5) DNA stored in water will be affected by acidic hydrolysis. For long-term storage, it is recommended to elute with Buffer GE and store at -20℃... Read More | Inquire | R669988 Component 50T Storage R669988A DNase I 1000 U -20℃. Avoid freeze/thaw cycle. R669988B 10×Reaction Buffer 1000 µL -20℃. Avoid freeze/thaw cycle. R669988C Buffer RL 35 mL RT R669988D Buffer RLC 35 mL RT R669988E Buffer RW1 40 mL RT R669988F Buffer RW2 (concentrate) 11 mL R669988 Component 50T Storage R669988A DNase I 1000 U -20℃. Avoid freeze/thaw cycle. R669988B 10×Reaction Buffer 1000 µL -20℃. Avoid freeze/thaw cycle. R669988C Buffer RL 35 mL RT R669988D Buffer RLC 35 mL RT R669988E Buffer RW1 40 mL RT R669988F Buffer RW2 (concentrate) 11 mL RT R669988G RNase-Free Water 10 mL RT R669988H Spin Columns FL with Collection Tubes 50 sets RT R669988I Spin Columns RM with Collection Tubes 50 sets RT R669988J RNase-Free Centrifuge Tubes (1.5 mL) 50 EA RTProductsThis kit is used for the extraction and purification of high-quality total RNA from a variety of plants, and is also suitable for the extraction of fungal mycelial RNA. The unique separation column is used for homogenization and filtration of high viscosity plant or fungal lysates, while the silicon matrix membrane is used to adsorb the RNA for purification, so that various contaminants, such as polysaccharides, are effectively removed by washing, and the eluted RNA can be directly used in various downstream experiments. The molecular weight of RNA extracted by this kit is more than 200 bases, with high purity and almost no DNA residue. For RNA experiments that are very sensitive to trace DNA, the residual DNA can be removed by digestion on a column using RNase-free DNase. The extracted RNA can be used in Northern Blot, Dot Blot, RT-PCR and in vitro translation experiments.Self-contained reagents: β-mercaptoethanol, anhydrous ethanol (freshly opened or for RNA extraction).Pre-experiment Preparation and Important Notes1. To prevent RNase contamination, attention should be paid to the following aspects:1) Use RNase-free plastics and tips to avoid cross-contamination.2) RNase-free water should be used to prepare the solution.(3) Operators wear disposable masks and gloves, and change gloves diligently during the experiment.2. To prevent RNase contamination, attention should be paid to the following aspects:1) Use RNase-free plastics and tips to avoid cross-contamination.(2) Glassware should be dry-roasted at 180°C for 4 hours before use, and plasticware can be soaked in 0.5M NaOH for 10 minutes, rinsed thoroughly with water and autoclaved.3) RNase-free water should be used to prepare the solution.(4) Operators wear disposable masks and gloves, and change gloves diligently during the experiment.3. Avoid repeated freezing and thawing of the extracted samples, otherwise it will affect the amount and quality of RNA extraction.4. Please add β-mercaptoethanol to Buffer RL before use, add 10µl of β-mercaptoethanol to 1ml of Buffer RL, it can be stored for 1 month at room temperature. Buffer RL with β-mercaptoethanol can be stored at room temperature for 1 month. β-mercaptoethanol is not required for use of Buffer RLC.5. Anhydrous ethanol should be added to Buffer RW2 before first use according to the instructions on the reagent bottle label.6. If precipitation occurs in Buffer RL and Buffer RLC, heat to dissolve and leave at room temperature.7. All centrifugation steps are carried out at room temperature and all steps are performed quickly. Procedure1. 50-100 mg of plant tissue is quickly ground to a powder in liquid nitrogen and added to 600 µl of Buffer RL (check for addition of β-mercaptoethanol before use) or Buffer RLC. vortexing and oscillating to allow for adequate lysis.Note: 1) The main component of Buffer RL is guanidine isothiocyanate, which is suitable for lysis of most plant tissues. However, in some plant tissues (e.g. endosperm of corn), due to the special secondary metabolites, guanidine isothiocyanate causes precipitation of the sample, resulting in poor RNA extraction, in this case, Buffer RLC can be added instead of Buffer RL.2) Incubation at 56°C for 1-3 minutes helps tissue lysis, but do not incubate at high temperatures for plants with high starch content.2. Transfer all the liquid obtained in step 1 to an adsorption column (Spin Columns FL) that has been loaded into a collection tube, centrifuge at 12,000 rpm (~13,400 x g) for 2 minutes, and transfer the supernatant from the collection tube to a new centrifuge tube (supplied).Note: 1) The tip of the tip of the gun can be cut off when aspirating liquids to facilitate sampling.2) Spin Columns FL removes most of the debris, but a small portion will still flow out and a precipitate will form in the collection tube after centrifugation, so be careful to avoid aspirating the precipitate when proceeding to the next step.3. Add 0.5 times the volume of anhydrous ethanol to the clean lysate obtained in step 2 and mix rapidly.Note: Precipitation may occur upon addition of ethanol, but does not affect subsequent tests.4. Transfer the solution obtained in the previous step to the Spin Columns RM in the collection tube. If it is not possible to add all of the solution to the column at one time, centrifuge the column at 12,000 rpm for 15 seconds in two batches, discard the waste solution and put the column back into the collection tube.5. Add 350 µl Buffer RW1 to the adsorbent column, centrifuge at 12,000 rpm for 1 min, discard the waste liquid and put the adsorbent column back into the collection tube.6. Preparation of DNase I mixture: Take 52µl of RNase-Free Water, add 8µl of 10×Reaction Buffer and 20µl of DNase I (1U/µl) to it, mix well, and make a final volume of 80µl of reaction solution.7. Add 80µl of DNase I mixture directly to the adsorption column and incubate at 20-30°C for 15 minutes.8. Add 350 µl of Buffer RW1 to the adsorption column, centrifuge at 12,000 rpm for 1 minute, discard the waste liquid and put the column back into the collection tube.9. Add 500 µl of Buffer RW2 to the column (check that anhydrous ethanol is added before use), centrifuge at 12,000 rpm for 15 seconds, and discard the waste solution.10. Repeat step 9.11. Place the adsorbent column back into the collection tube, centrifuge at 12,000 rpm for 1 minute, and allow the column to come to room temperature for a few minutes to thoroughly dry out the anhydrous ethanol in the adsorbent column.Note: The purpose of this step is to remove residual ethanol from the adsorption column; ethanol residue can interfere with subsequent enzymatic reactions (zymography, PCR, etc.).12. Load the adsorption column into a new centrifuge tube, add 30-50 µl of RNase-Free Water to the middle of the adsorbent membrane, leave it at room temperature for 1 minute, centrifuge at 12,000 rpm for 1 minute, and store the resulting RNA solution at -70°C to prevent degradation.Note: 1) The volume of RNase-Free Water should not be less than 30 µl, too small volume affects the recovery rate.2) If you want to increase the RNA yield, repeat step 12 with 30-50 µl of fresh RNase-Free Water.3) If the RNA concentration is to be increased, the resulting solution can be reintroduced into the adsorption column and step 12 repeated... Read More |