| Description | Product Introduction:Due to the low stoichiometry of phosphorylation, the concentration of phosphopeptides is a key step for the successful implementation of phosphoproteomics experiments. PolyMAC provides an effective and significantly improved method to achieve more complete enrichment of Product Introduction:Due to the low stoichiometry of phosphorylation, the concentration of phosphopeptides is a key step for the successful implementation of phosphoproteomics experiments. PolyMAC provides an effective and significantly improved method to achieve more complete enrichment of phosphopeptides. This highly selective enrichment method can be used for most complex samples because it offers optimal specificity and recovery rate. PolyMAC is a polymer-based immobilized metal ion affinity capture method with excellent phosphoproteome coverage and recovery rate. It is a soluble nanopolymer designed to interact with phosphopeptides in solution, and then be captured on a solid-phase carrier for washing and phosphopeptide elution. Compared with the commonly used titanium dioxide and immobilized metal ion affinity capture methods, PolyMAC has better reproducibility and enrichment of phosphorylated peptides, with the selectivity of phosphorylated peptides close to 95% and the recovery rate > 90%. Importantly, PolyMAC has very good recovery rate and selectivity for samples with low total protein phosphorylation levels.Experimental Flowchart of Phosphopeptide Protein (Peptide Fragment) Extraction Kit (P1456460)Product Components and Storage Conditions:P1456460Component24T48T96TStorageP1456460APolyMAC Beads0.75 mL1.5 mL3 mL4℃P1456460BPolyMAC Loading Buffer25 mL50 mL100 mLRTP1456460CPolyMAC Washing Buffer I25 mL50 mL100 mLRTP1456460DPolyMAC Washing Buffer II25 mL50 mL100 mLRTP1456460EPolyMAC Elution Buffer3.75 mL7.5 mL15 mLRTP1456460FPolyMAC Tips24T48T96TRTProduct Features:Easy to operate: Phosphopeptides can be prepared quickly, requiring only a metal bath and a conventional centrifuge.High stability: Strict quality inspection is conducted for each batch, ensuring high reproducibility of experimental results.Operating Procedure:1.Add 200 µL of Loading Buffer to the dried sample (50 µg - 100 µg) after enzymatic hydrolysis and desalting, and fully resuspend the sample.2.Vortex the PolyMAC Beads thoroughly (for 10 - 20 seconds), then take 25 µL into a 1.5 mL centrifuge tube, centrifuge instantaneously for 2 - 3 seconds, and then remove the upper storage solution. (The Beads settle quickly, so the operation should be fast when taking them.)3.Add the resuspended sample to the centrifuge tube containing PolyMAC Beads, then place it on a mixer, and shake vigorously at 26°C, >1200 rpm for 25 minutes.4.Add the sample to PolyMAC - Tips, first centrifuge at 20 g for 2 minutes, then centrifuge at 100 g for 1 minute to ensure that the sample solution flows out from the tip of the Tips into the centrifuge tube. (The rotation speed should not be too high, and the operation should be fast.)5.Wash once with 200 µL of Loading Buffer: first centrifuge at 20 g for 2 minutes, then centrifuge at 100 g for 1 minute, and discard the filtrate. Repeat this step 3 times. (The rotation speed should not be too high, and the operation should be fast.)6.Wash once with 200 µL of Washing Buffer I: first centrifuge at 20 g for 2 minutes, then centrifuge at 100 g for 1 minute, and discard the filtrate. Repeat this step 3 times. (The rotation speed should not be too high, and the operation should be fast.)7.Wash once with 200 µL of Washing Buffer II: first centrifuge at 20 g for 2 minutes, then centrifuge at 100 g for 1 minute, and discard the filtrate. Repeat this step 3 times. (The rotation speed should not be too high, and the operation should be fast.)8.Put the Tips into a new centrifuge tube to collect the eluted phosphopeptides. Add 50 µL of Elution Buffer to the Tips, centrifuge at 20 g for 2 minutes, then add another 50 µL of Elution Buffer, first centrifuge at 20 g for 2 minutes, then centrifuge at 100 g for 1 minute, and collect the filtrate. (The rotation speed should not be too high, and the operation should be fast.)Note: In steps 4 - 8, if the liquid flows down slowly, the rotation speed can be increased appropriately, gradually increasing to 50 g, and do not increase too much at one time!9.If there is any solution remaining in the pipette tip, push it out into the collection tube with a pipette, lyophilize it, and store it at -80°C for mass spectrometry detection.Precautions:This product is only for scientific research use by professionals, and shall not be used for clinical diagnosis or treatment, nor for food or drugs... Read More | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export | Products contentN665954Component24 T96 TStorageN665954ATPS V136 µL144 µL-20℃. Avoid freeze/thaw cycle.N665954B5×FA Reaction Buffer96 µL384 µL-20℃. Avoid freeze/thaw cycle.N665954CTS Buffer72 µL288 µL-20℃. Avoid freeze/thaw cycle.N665954D2× Products contentN665954Component24 T96 TStorageN665954ATPS V136 µL144 µL-20℃. Avoid freeze/thaw cycle.N665954B5×FA Reaction Buffer96 µL384 µL-20℃. Avoid freeze/thaw cycle.N665954CTS Buffer72 µL288 µL-20℃. Avoid freeze/thaw cycle.N665954D2× PCR Mix600 µL2×1.2 mL-20℃. Avoid freeze/thaw cycle. * This kit is suitable for human genomic DNA library construction, the starting template DNA input amount is 1 ng, our company also has 50 ng and 5 ng of human genomic DNA starting transposase method library construction kit, in order to get a higher quality library, different starting amount of DNA is recommended to use different kits. Products IntroductionThis kit is developed for Illumina's high-throughput sequencing platform and provides the enzyme premix system and reaction buffer for genomic DNA library construction, including all components except PCR primers. Compared with the traditional library construction kits, this kit adopts the new transposase method for library construction, which can complete DNA fragmentation, end repair and junction reaction in one simple enzymatic reaction, significantly reducing the amount of template, reducing the number of experimental steps, and shortening the time of library construction; it adopts the high-fidelity DNA polymerase for library enrichment, and the preference-free PCR amplification can expand the coverage area of the sequence, which can be used for efficient and effective sequencing. The use of high-fidelity DNA polymerase for library enrichment and preference-free PCR amplification broadens the coverage area of the sequence and enables efficient preparation of DNA libraries for Illumina's second-generation sequencing platform. The kit is suitable for use with 1 ng of starting template DNA, and all reagents in the kit have been subjected to stringent quality control and functional validation to maximize the stability and reproducibility of library construction.Product Features● DNA fragmentation and junction ligation in one step.● Ultra-fidelity amplification minimizes amplification preference.Provide your own instruments, kits and consumables1. Magnetic frame: DynaMagTM-2 is recommended.2. DNA purification and recovery kit: It is recommended to use Kangwei DNA purification and recovery kit by magnetic bead method.3. Library PCR primer kit: It is recommended to use Kangwei transposase method for second generation sequencing multi-sample primer kit.4. Anhydrous ethanol, deionized water (pH between 7.0 and 8.0).5. Reaction tubes: It is recommended to use low adsorption PCR tubes with 1.5 ml centrifuge tubes.Tip: It is recommended to use a high quality filter tip to prevent contamination of kits and library samples. Pre-experiment Preparation and Important Notes1. Avoid repeated freezing and thawing of reagents.2. PCR products are easily contaminated due to improper operation, resulting in inaccurate results. It is recommended to isolate the PCR reaction system preparation area from the PCR product purification area, and to use special pipettes to clean the experimental areas at regular intervals.3. Bead purification: the beads should be equilibrated to room temperature before use, all operations on the beads should be carried out at room temperature, 80% ethanol should be dispensed freshly, the beads should be rinsed and dried until the surface is free of liquid reflections and has a frosted appearance, insufficient drying of the beads will cause ethanol residue that will affect the subsequent experiments, and over-drying of the beads will affect the efficiency of DNA recovery.4. The kit is suitable for human genomic DNA library construction, if the DNA sample is a PCR product, it should be ensured that its length>.500 bp, since transposases do not work on DNA ends, it is recommended to extend the PCR product by 50-100 bp at each end of the PCR product to avoid low coverage of the ends for sequencing. Sample PreparationDNA purity requirement: A260/A280 = 1.8-2.0. Sample DNA: dissolved in ultrapure water.DNA quantification: Too much or too little DNA will affect the quality of the library. It is recommended to use Nano to test the purity of the genomic DNA and then use Qubit to test the concentration of the genome (do not use any absorbance-based assay for template quantification). Schematic diagram of DNA banking process procedureDNA fragmentation, junction reaction 1. Add the following reagents to a 200 µl PCR tube:2. Mix by gently blowing with a pipette and centrifuge briefly so that all components are collected at the bottom of the tube.3. Place the above PCR tubes in the PCR instrument with the hot cap on and program the reaction as follows:inactivation reactionAfter the DNA is fragmented, the enzyme is still in a high active state, so it should be removed from the PCR instrument immediately and terminated by adding the Reaction Termination Buffer, in order to prevent the DNA from being fragmented too much and resulting in smaller library fragments.1. Add 3 µl of TS Buffer to the PCR tube containing the fragmentation product.2. Mix by gently blowing with a pipette and centrifuge briefly so that all components are collected at the bottom of the tube.3. Incubate at room temperature for 5 min, or if the room temperature is too low, place the reaction on a PCR instrument at 25°C with the thermal cover closed.PCR amplification1. Add the following reagents to a 200 µl PCR tube.2. Mix by gently blowing with a pipette and centrifuge briefly so that all components are collected at the bottom of the tube. 3. Place the above PCR tubes in the PCR instrument with the thermal cap open, and the reaction program is as follows:Selective recovery of library DNA fragmentsIt is recommended to use CombiVision Magnetic Beads DNA Purification and Recovery Kit for selective recovery of DNA fragments. When different sizes of DNA fragments are required, the amount of magnetic beads used is different, please refer to the attached table for the specific amount of magnetic beads used.(If using other brands of magnetic beads, you need to figure out the optimal amount of magnetic beads by yourself).Note: Amplification products can also be fragment length sorted and purified using the Gum Recovery Kit. If there is no special requirement for library length distribution, amplification products can also be purified directly from DNA fragments without selective recovery of DNA fragments as described on page 4 of the manual.1. CMPure should be equilibrated at room temperature for 30 min after shaking and mixing before use.2. Transfer the PCR products to a 1.5 ml centrifuge tube, rehydrate to 100 µl, add several volumes of magnetic beads equilibrated to room temperature, vortex for 5 seconds, and let stand at room temperature for 5 minutes.3. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant until the solution is clear, and carefully aspirate the supernatant and transfer it to a new 1.5 ml centrifuge tube.Note: Do not discard the top clear.4. Add several volumes of magnetic beads to the supernatant, vortex and shake for 5 seconds, then let stand at room temperature for 5 minutes.5. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant until the solution is clear, carefully aspirate the supernatant and discard it, avoiding contact with the beads that have bound the target DNA.Note: Do not discard the beads.6. Continue to keep the centrifuge tube fixed on a magnetic rack and add 200 µl of freshly prepared 80% ethanol to the tube and allow to stand at room temperature for 30 seconds, carefully discarding the supernatant.Note: When adding ethanol, the liquid must not be blown directly onto the beads.7. Repeat step 6 once.8. Keep the centrifuge tube fixed on a magnetic rack and leave to dry at room temperature until the surface of the beads is slightly cracked, add 20 µl of ddH2O to solubilize.Note: Do not over-dry the beads as this may affect the elution efficiency.9. Remove the tube from the magnetic rack, vortex to completely resuspend the beads, and allow to stand at room temperature for 5 minutes. Centrifuge briefly, place the tube on the magnetic rack until the solution is clear, and transfer the supernatant solution to a new tube. Table: Suggested amount of magnetic beads for different segment selection recoveryLibrary DNA fragment purificationWe recommend the use of the Kangwei Century Magnetic Bead Method DNA Purification and Recovery Kit.1. CMPure should be equilibrated at room temperature for 30 min after shaking and mixing before use.2. 50 µl of magnetic beads equilibrated to room temperature were added to the PCR product, vortexed and shaken for 5 seconds, and then left to stand at room temperature for 5 minutes.3. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant solution until the solution is clear (approximately 3-5 minutes), carefully aspirate the supernatant and discard it, avoiding contact with the beads that have bound the target DNA. Note: Do not discard the beads.4. Continue to keep the centrifuge tube fixed on a magnetic rack and add 200 µl of freshly prepared 80% ethanol to the centrifuge tube and allow to stand at room temperature for 30 seconds, carefully discarding the supernatant.Note: When adding ethanol, the liquid must not be blown directly onto the beads.5. Repeat step 4.6. Keep the centrifuge tube fixed on a magnetic rack and leave to dry at room temperature until the surface of the beads is slightly cracked, add 25 µl of ddH2O to solubilize.Note: Do not over-dry the beads as this may affect the elution efficiency.7. Remove the tube from the magnetic rack, vortex to completely resuspend the beads, and allow to stand at room temperature for 5 minutes. Centrifuge briefly, place the tube on the magnetic rack until the solution is clear, and transfer the supernatant solution to a new tube. Library quality controlDetermination of library concentrationIn order to obtain high-quality sequencing results, accurate quantification of DNA libraries is required, and the first recommendation is to use Real-timePCR methods are used for absolute quantification of DNA libraries. Additionally, fluorescent dye methods such as the Qubit method or the fluorescent dye picogreen method can be used; do not use quantification methods based on absorbance measurements here. The following approximate formula can be used to convert the molar concentration of the DNA library.Library fragment distributionThe prepared DNA libraries can be detected by agarose gel electrophoresis or Agilent 2100 Bioanalyzer.Range of segment length distributions... Read More | Product contentN666081Component50 TStorageN666081ANc-Buffer A50 mL2-8℃N666081BNc-Buffer B3 mL2-8℃N666081CNc-Buffer C25 mL2-8℃N666081DProtease Inhibitor Cocktail750 µL-20℃. Avoid freeze/thaw cycle.ProductsThe Nc-Nucleus/Plasma Protein Extraction Kit is a simple and rapid Product contentN666081Component50 TStorageN666081ANc-Buffer A50 mL2-8℃N666081BNc-Buffer B3 mL2-8℃N666081CNc-Buffer C25 mL2-8℃N666081DProtease Inhibitor Cocktail750 µL-20℃. Avoid freeze/thaw cycle.ProductsThe Nc-Nucleus/Plasma Protein Extraction Kit is a simple and rapid method for extracting nucleus and plasma proteins from mammalian cells and tissues, and the extracted proteins remain biologically active. The kit first cleaves the cell membrane and releases plasma proteins using the plasma protein extraction reagent, and then centrifuges the nucleus to obtain a nucleus precipitate. Finally, the nuclear proteins are extracted by the nuclear protein extraction reagent. The extracted nuclear and plasma proteins are of high purity, effectively avoiding cross-contamination of nuclear and plasma proteins, and can be used for subsequent operations such as Western, Gel Shift, reporter gene detection and enzyme activity determination.Caveat1. If phosphorylated proteins are to be extracted, add a phosphatase inhibitor to the extraction reagent.2. All sample handling should be done on ice.3. The amount of reagents can be adjusted according to the specific experimental situation to ensure that the ratio of each reagent used is Nc-Buffer A:Nc-Buffer B:Nc-Buffer C = 100:5.5:50.4. Higher speeds can be used for centrifugation.ProcedureI Extraction of cytoplasmic and cytosolic proteins from cells1. Please remove the extraction reagents Nc-Buffer A and Nc-Buffer C for pre-cooling before protein extraction.2. Collect the cells and count them. Centrifuge to remove supernatant.3. 1×107 cells were added with 1 ml of Nc-Buffer A (added to Protease Inhibitor Cocktail at a ratio of 1:99 within 2-3 minutes prior to protein pumping), vortexed for 5 seconds to mix well, and incubated on ice for 20 minutes.Note: The characteristics of various cells are different, and the amount of Nc-Buffer A needs to be adjusted according to the characteristics of different cells. If the protein concentration is small, reduce the amount of Nc-Buffer A and subsequent Nc-Buffer B and Nc-Buffer C proportionally.4. Add 55 µl of Nc-Buffer B, vortex for 5 seconds to mix thoroughly, and incubate on ice for 1 minute.5. Centrifuge at 12,000 rpm (~13,400 x g) for 15 minutes at 4°C, collect the supernatant (as clean as possible) into a new centrifuge tube and store at -20°C (this extract is cytoplasmic protein).6. Add 500 µl of Nc-Buffer C (add Protease Inhibitor Cocktail at a ratio of 1:99 before use) to the precipitate obtained in the previous step, vortex for 5 seconds to mix thoroughly, resuspend the precipitate and incubate on ice for 40 minutes, vortexing and mixing at 10-minute intervals for about 15-30 seconds each time.7. Centrifuge at 12,000 rpm for 15 minutes at 4°C, collect the supernatant (as clean as possible) into a new centrifuge tube and store at -20°C (this extract is for cytosolic proteins).II Extraction of cytoplasmic and cytosolic proteins from tissues1. Sampling and preservation of tissues.2. Remove the extraction reagents Nc-Buffer A and Nc-Buffer C for pre-cooling before protein extraction.3. Weigh the tissue and add 1 ml of Nc-Buffer A per 100 mg of tissue (add Protease Inhibitor Cocktail 2-3 minutes before protein extraction at a ratio of 1:99), homogenize well on ice with a homogenizer, and incubate on ice for 20 minutes.Note: The characteristics of various tissues are different, and the amount of Nc-Buffer A needs to be adjusted according to different tissues. If the protein concentration is small, reduce the amount of Nc-Buffer A and subsequent Nc-Buffer B and Nc-Buffer C proportionally.4. Add 55 µl of Nc-Buffer B, vortex for 5 seconds to mix thoroughly, and place on ice for 1 minute of incubation.5. Centrifuge at 12,000 rpm for 15 minutes at 4°C, collect the supernatant (as clean as possible) into a new centrifuge tube and store at -20°C (this extract is cytoplasmic protein).6. Add 500 µl of Nc-Buffer C (add Protease Inhibitor Cocktail at a ratio of 1:99 before use) to the precipitate obtained in the previous step, vortex for 5 seconds to mix thoroughly, resuspend the precipitate and incubate on ice for 40 minutes, vortexing and mixing at 10-minute intervals at, each time for about 15-30 seconds.7. Centrifuge at 12,000 rpm for 15 minutes at 4°C, collect the supernatant (as clean as possible) into a new centrifuge tube and store at -20°C (this extract is cytosolic protein)... Read More | Q665720 Component 200T Storage Q665720A Buffer L2 25 mL RT Q665720B Buffer N3 80 mL RT Q665720C Buffer PB 35 mL RT Q665720D Buffer PW (concentrate) 25 mL RT Q665720E Buffer EB 30 mL RT Q665720F RNase A (10 mg/mL) 800 渭L RT Q665720G Spin Columns DM with Collection Tubes 200 EA RTProduct Q665720 Component 200T Storage Q665720A Buffer L2 25 mL RT Q665720B Buffer N3 80 mL RT Q665720C Buffer PB 35 mL RT Q665720D Buffer PW (concentrate) 25 mL RT Q665720E Buffer EB 30 mL RT Q665720F RNase A (10 mg/mL) 800 渭L RT Q665720G Spin Columns DM with Collection Tubes 200 EA RTProduct IntroductionThe biggest feature of this kit: simple and fast, high extraction volume. The whole extraction process does not take more than 10 minutes, without centrifugation to collect bacteria and resuspend the bacterium, directly add the unique super lysate Buffer L2 to the cultured bacterial solution, followed by neutralization, centrifugation and passing through the column, and the extracted plasmid can be as high as 30 µg, and maximize the removal of proteins, genomes and other impurities. The extracted plasmid DNA can be directly used for bacterial transformation, digestion, PCR, in vitro transcription, sequencing and other downstream experiments.Self-contained reagent: anhydrous ethanol.Pre-experiment Preparation and Important Notes1. The kit can be stored in a dry, room temperature (15-30°C) environment for 1 year. For longer storage, the centrifuge columns can be placed at 2-8°C.2. Before the first use, add all of the RNase A solution to Buffer N3, mix well, and store at 2-8°C.3. Anhydrous ethanol should be added to Buffer PW before the first use according to the instructions on the reagent bottle label.4. If there is any precipitation in Buffer L2 before use, please put it in a 37℃ water bath and keep mixing until the solution becomes clear before use.Operation steps1. Take 600 µl of bacterial culture into a 1.5 ml centrifuge tube (supplied).2. Add 100 µl of Buffer L2 to the above centrifuge tube and gently turn the solution up and down 8 times; the solution should change from turbid to a clear purple color, indicating complete lysis. The cleavage time should not exceed 2 minutes.3. Add 350 µl of Buffer N3 to the above centrifuge tube (please check that RNaseA has been added first) and immediately mix well by turning up and down about 8-10 times, at which point the solution should turn completely yellow and a yellow precipitate should form. centrifuge at 13,000 rpm for 2-3 minutes.4. Slowly pour the supernatant obtained in step 3 into the prepared adsorption columns (Spin Columns DM with Collection Tubes) to avoid sedimentation into the columns.5. Centrifuge at 13,000 rpm for 15 seconds, pour off the waste liquid in the collection tube, and put the adsorption column back into the collection tube.6. Add 150 µl Buffer PB to the adsorption column and centrifuge at 13,000 rpm for 15 seconds.7. Add 400 µl Buffer PW to the adsorption column (please check that anhydrous ethanol has been added first) and centrifuge at 13,000 rpm for 1 minute.8. Place the adsorbent column in a new centrifuge tube (self-provided), add 30-100 µl Buffer EB to the middle part of the adsorbent membrane, centrifuge at 13,000 rpm for 1 min, collect the plasmid DNA, and store at -20°C for long term storage.When the amount of extracted bacterial liquid is >600µl, the following procedure can be used:1. This kit can extract up to 3ml of bacterial solution, if the amount of extracted bacterial solution is more than 600µl, it is necessary to centrifuge the bacterial solution exceeding 600µl at 13,000rpm for 30 seconds (to collect the bacterial body), discard the supernatant and then add 600µl of bacterial solution, and then resuspend the bacterial body at the bottom of the tube thoroughly and then proceed to the following operation.2. Add 100µl Buffer L2 to the above centrifuge tube, gently invert the solution up and down 10 times, if the solution is not clarified, need to continue to invert the mixing until the solution becomes a clear purple color, the lysis time should not be more than 2 minutes. (If the solution is still turbid, the amount of bacteria is too large, and the amount of bacteria should be reduced appropriately.)3. Add 350 µl of Buffer N3 to the above centrifuge tube (please check that RNaseA has been added first) and immediately mix well by turning up and down until the purple solution turns completely yellow and a yellow precipitate is formed before proceeding to the next step. centrifuge at 13,000 rpm for 5 minutes.4. Transfer the supernatant to a new centrifuge tube, add 200 µl of isopropanol, mix up and down several times, mix well and transfer to the adsorbent column (Spin Columns DM with Collection Tubes), due to the amount of solution is too large, this time, it is necessary to centrifuge the column in two separate times, centrifugation at 13,000 rpm for 15 seconds, pour off the waste liquid in the collection tube, and put the adsorbent column back to the The adsorbent column should be placed back into the collection tube.5. Add 150 µl Buffer PB to the adsorption column and centrifuge at 13,000 rpm for 15 seconds.6. Add 400 µl Buffer PW to the adsorption column (please check that anhydrous ethanol has been added first) and centrifuge at 13,000 rpm for 1 minute.7. Place the adsorbent column in a new centrifuge tube (self-provided), add 50-200 µl Buffer EB to the middle part of the adsorbent membrane, leave it at room temperature for 2 min, centrifuge at 13,000 rpm for 1 min, collect the plasmid DNA, and store it at -20°C for a long time... Read More |