| Description | Inquire | Product content:E665636Component50 TStorageE665636ABuffer P115 mLRTE665636BBuffer P215 mLRTE665636CBuffer E315 mLRTE665636DBuffer PS15 mLRTE665636EBuffer PW (concentrate)10 mLRTE665636FEndo-Free Buffer EB10 mLRTE665636GRNase A (10 mg/mL)150 µLRTE665636HEndo-Remover FMwith Collection Tubes50 Product content:E665636Component50 TStorageE665636ABuffer P115 mLRTE665636BBuffer P215 mLRTE665636CBuffer E315 mLRTE665636DBuffer PS15 mLRTE665636EBuffer PW (concentrate)10 mLRTE665636FEndo-Free Buffer EB10 mLRTE665636GRNase A (10 mg/mL)150 µLRTE665636HEndo-Remover FMwith Collection Tubes50 EARTE665636ISpin Columns DMwith Collection Tubes50 EART Product Introduction:Endotoxins are a common pollutant in plasmid extraction. Due to the high sensitivity of eukaryotic cells to endotoxins, the presence of endotoxins in plasmids can greatly reduce the transfection efficiency of eukaryotic cells. This reagent kit provides a simple, fast, and efficient new method for extracting endotoxin free plasmids. The extracted plasmids remove endotoxins to the maximum extent possible and can effectively remove contamination of genomic DNA, RNA, proteins, etc. The operation is simple and convenient. This reagent kit is suitable for extracting 1-5mL of bacterial solution. On the basis of alkaline lysis of cells, it efficiently and specifically binds plasmid DNA through a new silicon-based membrane. Each adsorption column can adsorb up to 40% µ The plasmid DNA of g is effectively removed using a special buffer system and endotoxin removal filter column, effectively removing impurities such as endotoxins and proteins. The plasmid obtained from this kit has high purity and stable quality, making it particularly suitable for cell transfection. It can also be used for downstream experiments such as DNA sequencing, PCR, PCR based mutations, in vitro transcription, transformed bacteria, and endonuclease digestion.Self prepared reagents: anhydrous ethanol, isopropanol.Preparation and important precautions before the experiment:1. All components can be stably stored for 1 year in a dry, room temperature (15-30 ℃) environment. The adsorption column can be stored for a longer time at 2-8 ℃. Buffer P1 with RNase A added can be stably stored for 6 months at 2-8 ℃. 2. Before the first use, add all RNase A solution to Buffer P1, mix well, and store at 2-8 ℃. Before use, let it sit at room temperature for a period of time. After returning to room temperature, use.3.Before the first use, anhydrous ethanol should be added to the Buffer PW according to the instructions on the reagent bottle label.4. Before use, please check if there is any crystallization or precipitation in Buffer P2 and Buffer E3. If there is any crystallization or precipitation, you can take a water bath at 37 ℃ for a few minutes to restore clarity.5. Be careful not to come into direct contact with Buffer P2 and Buffer E3, and immediately cover them tightly after use.6.The amount and purity of plasmid extraction are related to factors such as bacterial culture concentration, strain type, plasmid size, and plasmid copy number.Operation steps:1. Take 1-5 mL of overnight cultured bacterial solution and add it to a centrifuge tube (provided). Centrifuge at 13000 rpm (~16200 × g) for 30 seconds to collect bacteria, and try to discard all the supernatant as much as possible.2. Add 250 to the centrifuge tube containing bacterial sediment µ L Buffer P1 (please check if RNase A has been added first), mix thoroughly with a pipette or vortex oscillator, and suspend bacterial precipitation.Attention: If the bacterial blocks are not thoroughly mixed, it will affect the cracking effect, resulting in low extraction amount and purity.3. Add 250 to the centrifuge tube µ L Buffer P2, gently invert and mix 8-10 times, allowing the bacterial cells to fully lyse. Leave at room temperature for 3-5 minutes. At this point, the solution should become clear and viscous.Attention: Mix gently and do not shake vigorously to avoid interrupting genomic DNA and mixing genomic DNA fragments in the extracted plasmid. If the solution does not become clear, it indicates that the bacterial count may be too high and the lysis may not be complete. The bacterial count should be reduced.4. Add 250 to the centrifuge tube µ L Buffer E3, immediately invert and mix 8-10 times until white flocculent precipitates appear. Let it stand at room temperature for 5 minutes. Centrifuge at 13000 rpm for 5 minutes, extract the supernatant, and add it to a filter column (Endo Remove FM). Centrifuge at 13000 rpm for 1 minute to filter, and collect the filtrate in a centrifuge tube (self provided).Attention: After adding Buffer E3, it should be mixed evenly immediately to avoid local precipitation. 5. Add 225 to the filtrate µ Mix L isopropanol upside down.6. Column balance: Add 200 to the spin columns DM that have been loaded into the collection tube µ L Buffer PS, centrifuge at 13000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.7. Transfer the mixed solution of filtrate and isopropanol from step 5 to an equilibrium adsorption column (already loaded into a collection tube).8.13000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.Attention: The maximum volume of the adsorption column is 750 µ L. If the sample volume is greater than 750 µ L can be added in batches. 9. Add 750 to the adsorption column µ L Buffer PW (please check if anhydrous ethanol has been added first), centrifuge at 13000 rpm for 1 minute, and discard the waste liquid in the collection tube.10. Place the adsorption column back into the recovery manifold and centrifuge at 13000 rpm for 1 minute. Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).11. Place the adsorption column in a new collection tube and add 50-100 to the middle of the adsorption membrane µ L Endo Free Buffer EB, let it stand at room temperature for 2-5 minutes, centrifuge at 13000 rpm for 2 minutes, and collect the plasmid solution into a centrifuge tube- Store the plasmid at 20 ℃.Note: 1) To increase the efficiency of plasmid recovery, the obtained solution can be added back to the adsorption column, left at room temperature for 2-5 minutes, centrifuged at 13000 rpm for 2 minutes, and collected into a centrifuge tube.2) When the plasmid copy number is low or>10 kb, preheating the Endo Free Buffer EB in a water bath at 65-70 ℃ can increase the extraction efficiency... Read More | O665690 Component 50T Storage O665690A DNase I 1000 U -20℃.Avoid freeze/thaw cycle. O665690B 10×Reaction Buffer 1000 µL -20℃.Avoid freeze/thaw cycle. O665690C Buffer RLS 40 mL RT O665690D Buffer RW1 40 mL RT O665690E Buffer RW2 (concentrate) 11 mL RT O665690F RNase-Free Water O665690 Component 50T Storage O665690A DNase I 1000 U -20℃.Avoid freeze/thaw cycle. O665690B 10×Reaction Buffer 1000 µL -20℃.Avoid freeze/thaw cycle. O665690C Buffer RLS 40 mL RT O665690D Buffer RW1 40 mL RT O665690E Buffer RW2 (concentrate) 11 mL RT O665690F RNase-Free Water 10 mL RT O665690G Spin Columns FS with Collection Tubes 50 EA RT O665690H Spin Columns RM with Collection Tubes 50 EA RT O665690I RNase-Free Centrifuge Tubes (1.5 mL) 50 EA RTProduct IntroductionThis kit is suitable for extracting RNA from a wide range of plants, even from plants rich in polysaccharides and polyphenols, high quality RNA can be successfully extracted, such as rice leaves, wheat leaves, corn leaves, tobacco leaves, pine needles, ginkgo leaves, poplar leaves, pomegranate leaves, holly leaves, apples, peaches, pears, tomatoes, cherries, apricots, bananas, grapes, loquats, cinnamon rinds, cinnamon pulp, lychee fruit rinds, lychee pulp, soybean, peanut, corn, potato tuber, moonflower petal, pomegranate petal, shiitake mushroom, flat mushroom and other samples. The unique lysate formula can rapidly inactivate the RNA enzyme in the cell, effectively remove the effect of polysaccharide and polyphenol on RNA extraction, without the need for phenol, chloroform and other reagents, while using silicon matrix membrane adsorption of RNA for purification, the total RNA extracted is highly pure, without the contamination of genomes, proteins and other impurities, and can be used for Real Time RT-PCR, RT-PCR, It can be used for Real Time RT-PCR, RT-PCR, Northern Blot, Dot Blot, in vitro translation and other downstream experiments.RNA yieldSelf-contained reagents: β-mercaptoethanol, anhydrous ethanol (freshly opened or for RNA extraction)Pre-experiment Preparation and Important Notes1. To prevent RNase contamination, attention should be paid to the following aspects:1) Use RNase-free plastics and tips.(2) Operators wear disposable masks and gloves, and change gloves diligently during the experiment.2. Avoid repeated freezing and thawing of the extracted samples, otherwise it will affect the rate and quality of RNA extraction.3. If Buffer RLS produces a precipitate, heat to dissolve it and leave at room temperature.4. Please add β-mercaptoethanol to Buffer RLS before use, add 20µl β-mercaptoethanol to 1ml Buffer RLS. Buffer RLS with β-mercaptoethanol can be stored for 1 month at room temperature.5. Anhydrous ethanol should be added according to the instructions on the reagent bottle label before using Buffer RW2 for the first time. Operation steps1. Homogenization: Take 50-100mg of plant tissue and quickly grind it into powder in liquid nitrogen, add 500µl of Buffer RLS (please check whether β-mercaptoethanol is added before use), and immediately mix it by vortexing with vigorous shaking.Note: For materials that are extremely rich in water content, such as watermelon pulp, tomato, pear pulp, etc., more material can be added appropriately, up to 200 mg; for starch-rich samples or mature leaves, the amount of Buffer RLS can be increased appropriately, up to 700 µl.2. Centrifuge at 12,000 rpm (~13,400 x g) for 2 min at 4°C.3. Transfer the supernatant into the filter columns (Spin Columns FS) that have been loaded into the collection tubes, centrifuge at 12,000 rpm at 4°C for 1 minute, carefully aspirate the supernatant in the collection tubes and transfer it to new RNase-Free centrifugation tubes (self-provided), avoiding the tip of the gun from touching the cell debris precipitation in the collection tubes as much as possible.4. Slowly add 0.5 times the volume of the supernatant in anhydrous ethanol, mix well (a precipitate may appear), and transfer the resulting solution together with the precipitate to a Spin Columns RM in a collection tube, or in two batches if you cannot add all of the solution at once. centrifuge the column for 1 minute at 12,000 rpm at 4°C. Dispose of the spent solution and place the column back into the collection tube. Centrifuge at 12,000 rpm for 1 minute at 4°C, discard the spent solution and return the column to the collection tube.5. Add 350 µl of Buffer RW1 to the adsorbent column RM, centrifuge at 12,000 rpm at 4°C for 1 min, discard the waste solution and put the adsorbent column back into the collection tube.6. Preparation of DNase I mixture: Take 52µl of RNase-Free Water, add 8µl of 10×Reaction Buffer and 20µl of DNase I (1U/µl) to it, mix well, and prepare a final volume of 80µl of reaction solution.7. Add 80µl of DNase I mixture directly to the adsorption column and incubate at 20-30°C for 15 minutes.8. Add 350 µl of Buffer RW1 to the adsorbent column RM, centrifuge at 12,000 rpm at 4°C for 1 min, discard the waste solution and put the adsorbent column back into the collection tube.9. Add 500 µl of Buffer RW2 to the adsorbent column RM (check that anhydrous ethanol is added before use), centrifuge at 12,000 rpm for 1 minute at 4°C, discard the waste solution and put the adsorbent column back into the collection tube.10. Repeat step 9.11. Centrifuge at 12,000 rpm for 2 minutes at 4°C.Note: The purpose of this step is to remove residual ethanol from the adsorption column; ethanol residue can interfere with subsequent enzymatic reactions (zymography, PCR, etc.).12. Load the adsorption column RM into new RNase-Free Centrifuge Tubes (1.5 ml), add 30-50 µl of RNase-Free Water dropwise to the middle part of the adsorption membrane overhang, leave it at room temperature for 2 min, and centrifuge at 12,000 rpm at 4°C for 1 min, and store the resulting RNA solution at -70°C to prevent degradation.Note: 1) The volume of RNase-Free Water should not be less than 30 µl, too small volume affects the recovery rate.2) If you want to increase the RNA yield, repeat step 12 with 30-50 µl of fresh RNase-Free Water.3) If the RNA concentration is to be increased, the resulting solution can be reintroduced into the adsorption column and step 12 repeated... Read More | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export | Products contentProducts IntroductionThis kit is suitable for simple, rapid and efficient isolation and purification of DNA/RNA from whole blood, tissue homogenates, swabs, serum, plasma and other cell-free body fluids, etc. The unique buffer system enables the viral nucleic acids in the lysate to Products contentProducts IntroductionThis kit is suitable for simple, rapid and efficient isolation and purification of DNA/RNA from whole blood, tissue homogenates, swabs, serum, plasma and other cell-free body fluids, etc. The unique buffer system enables the viral nucleic acids in the lysate to bind to the silica gel centrifugal adsorbent columns in a highly efficient manner, and the viral nucleic acids obtained are of high purity and stable quality, free of protein, nuclease and other impurities, and can be used in a variety of routine operations, including PCR, fluorescence quantitative PCR and other experiments. It can be used for a variety of routine operations, including PCR, fluorescence quantitative PCR and other experiments.Bring your own instrumentsThermostatic mixer.Pre-experiment Preparation and Important Notes1. Read these instructions carefully before experimenting.2. If Proteinase K is to be stored for a long period of time, please keep it at -20℃.3. Check Buffer RLC for crystallization or precipitation prior to use, and if crystallization or precipitation occurs, redissolve Buffer RLC in a 56°C water bath.4. Pre-treatment of tissue samples: Take 20 mg of tissue samples into 1.5 mL centrifuge tubes (self-provided), add 500 µL of Buffer RLC, and after the tissue homogenizer breaks up, centrifuge the samples for 1 minute at 12,000 rpm (~13,400×g), and take 200 µL of supernatant as samples. procedure1. Take a 1.5 mL centrifuge tube (provided), add 500 µL of Buffer RLC, 200 µL of sample, 20 µL of Proteinase K, vortex for 5 s, and then place it in a thermostatic mixer at 1200 rpm for 10 min at room temperature. Note: For wet swab samples, 200 µL of sample was taken after sufficiently shaking and mixing. Note: For wet swabs, 200 µL was taken from the sample after it was soaked in 400 µL of saline, shaken and mixed thoroughly for 5 minutes, and then centrifuged at 12,000 rpm for 1 minute, and 200 µL was taken for extraction.2. Instantly remove the centrifuge tube and add the solution from step 1 to the Spin Columns DM in the collection tube. centrifuge at 12,000 rpm (~13,400 x g) for 1 minute, pour off the waste liquid from the collection tube, and return the column to the collection tube.3. Add 500 µL of Buffer PGWT to the adsorbent column, centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid from the collection tube, and return the column to the collection tube.4. Add 500 µL of Buffer GWT2 to the adsorbent column, centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid from the collection tube, and return the column to the collection tube.5. Centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Place the adsorption column at room temperature for 2 minutes and allow to dry.6. Place the column in a new collection tube (RNase-Free Centrifuge Tube), add 40-100 µL of RNase-Free Water to the center of the column membrane, let it stand at room temperature for 2 minutes, and then centrifuge at 12,000 rpm for 1 minute to collect the nucleic acid solution. Store at -80℃ for a long time... Read More |