| Description | Annexins are a family of calcium-dependent phospholipid-binding proteins that preferentially bind phosphatidylserine (PS). Under normal physiologic conditions, PS is predominantly located in the inner leaflet of the plasma membrane. Upon initiation of apoptosis, PS loses its asymmetric Annexins are a family of calcium-dependent phospholipid-binding proteins that preferentially bind phosphatidylserine (PS). Under normal physiologic conditions, PS is predominantly located in the inner leaflet of the plasma membrane. Upon initiation of apoptosis, PS loses its asymmetric distribution across the phospholipid bilayer and is translocated to the extracellular membrane leaflet marking cells as targets of phagocytosis. Once on the outer surface of the membrane, PS can be detected by fluorescently labeled Annexin V in a calcium-dependent manner. In early-stage apoptosis, the plasma membrane excludes viability dyes such as propidium iodide (PI), 7-AAD. These cells will stain with Annexin V but not a viability dye, thus distinguishing cells in early apoptosis. However, in late stage apoptosis, the cell membrane loses integrity thereby allowing Annexin V to also access PS in the interior of the cell. A viability dye can be used to resolve these late-stage apoptotic and necrotic cells (Annexin V, viability dye-positive) from the early-stage apoptotic cells (Annexin V positive, viability dye-negative). This kit is suitable for the identification and enumeration of dead cells, such as apoptotic or necrotic cells, by flow cytometry. Kit ContentsA1372402Components20T50T100TStorageQuantity Per TestA1372402A10X Annexin V Binding Buffer5 mL10 mL20 mL2-8℃200 µL per 0.5–1.0 × 10⁵ cells.A1372402BAnnexin V (PE)40 µL100 µL200 µL2-8℃. Store in the dark.2 µL per 0.5–1.0 × 10⁵ cells.A1372402C7-AAD Staining Solution400 µL1 mL2 mL2-8℃. Store in the dark.20 µL per 0.5–1.0 × 10⁵ cells.Note: The recommended number of cells to stain per test is per 0.5–1.0 × 10⁵ cells.Instruction for use1. Dilute 10x Binding Buffer to 1x using distilled water (1 mL 10x Binding Buffer + 9 mL ddH2O).2. Wash cells twice with cold PBS and then resuspend the desired amount of cells in Annexin V Binding Buffer at a concentration of 0.5-1.0x 10⁶/mL.3. Add 2 µl of Annexin V (PE) and 20 µl 7-AAD to 200 µL of the cell suspension.4. Gently vortex the cells and incubate for 10 min at RT (25°C) in the dark.5. Analyze by flow cytometry within 1 hr... Read More | Inquire | Inquire | Product content: M665559Component50 TStorageM665559ABuffer GTT15 mLRTM665559BBuffer GL15 mLRTM665559CBuffer GW1(concentrate)13 mLRTM665559DBuffer GW2(concentrate)15 mLRTM665559EBuffer GE15 mLRTM665559FProteinase K1.25 mLRTM665559GSpin CoLumns DM with CoLLection Tubes50 Product content: M665559Component50 TStorageM665559ABuffer GTT15 mLRTM665559BBuffer GL15 mLRTM665559CBuffer GW1(concentrate)13 mLRTM665559DBuffer GW2(concentrate)15 mLRTM665559EBuffer GE15 mLRTM665559FProteinase K1.25 mLRTM665559GSpin CoLumns DM with CoLLection Tubes50 EART Product Introduction:This reagent kit is suitable for extracting high-purity total DNA from fresh or frozen mouse or rat tails. The method provided by this reagent kit is simple and feasible, and the purification process does not require phenol or chloroform extraction. It can obtain DNA fragments up to 50 kb, and can also effectively recover fragments of 100 bp. This reagent kit uses a unique lysis solution to effectively lyse mouse tail samples. The optimized buffer system efficiently binds the DNA generated after the lysis of mouse tail to the silica matrix adsorption column, while other pollutants can flow through the membrane; Inhibitors of PCR and other enzymatic reactions can be effectively removed through a two-step washing process, followed by washing with low salt buffer or water to obtain high-purity DNA. The purified DNA can be directly used for downstream experiments such as enzyme digestion, PCR, ReaL Time PCR, library construction, Southern BLot, and molecular labeling.Self prepared reagent: anhydrous ethanol.Preparation and important precautions before the experiment:1. Samples should avoid repeated freeze-thaw cycles, otherwise it may result in smaller extracted DNA fragments and a decrease in extraction volume.2.Before the first use, anhydrous ethanol should be added to BufferGW1 and BufferGW2 according to the instructions on the reagent bottle label.3. Before use, please check if there is any crystallization or precipitation in the Buffer GL. If there is any crystallization or precipitation, please dissolve the Buffer GL again in a 56 ℃ water bath.Operation steps:1. Take a tail of a rat or two mice with a length of 0.4-0.6 cm, grind it into fine powder in liquid nitrogen or cut it into pieces and place it in a centrifuge tube (provided by oneself). Join 180 µ L Buffer GTT, shake and mix well. Note: Ensure that the starting quantity of the organization does not exceed the recommended range.2. Add 20 µ L Protein K, vortex oscillation, thoroughly mix.3. Place in a 56 ℃ water bath until the tissue solution is completely clear. Generally, digestion is required for 6-8 hours. During the incubation process, vortex oscillation is required to evenly disperse the sample. Note: 1) If there is still gel like substance after incubation and vortex oscillation, digest overnight or add 20 more if necessary µ L Protein K digestion will not affect subsequent operations. 2) To remove RNA, add 4 after completing the above steps µ L 100 mg/mL RNase A solution, shake well and let stand at room temperature for 5-10 minutes.4.12000 rpm (~13400 × g) for 1 minute to remove undigested tissues similar to mouse hair. Transfer the supernatant to a new centrifuge tube (provided by oneself).5. Add 200 µ L Buffer GL, vortex oscillation, thoroughly mixed. Join 200 µ L anhydrous ethanol, vortex and shake, thoroughly mix. Short centrifugation allows the solution on the tube wall to be collected to the bottom of the tube.Attention: 1) After adding Buffer GL and anhydrous ethanol, immediately vortex and shake to mix well.2) If multiple samples are operated together, Buffer GL and anhydrous ethanol can be mixed in equal proportions and added to the samples together.3) The addition of Buffer GL and anhydrous ethanol may produce white precipitates, which will not affect subsequent experiments.6. Add all the solutions obtained in step 5 to the adsorption column (Spin CoLumins DM) that has been loaded into the collection tube. If the solution cannot be added at once, it can be transferred multiple times. Centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.7. Add 500 to the adsorption column µ L Buffer GW1 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.8. Add 500 to the adsorption column µ L Buffer GW2 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.Note: To further improve DNA purity, repeat step 8.9.12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry. Note: The purpose of this step is to remove residual ethanol from the adsorption column, which will affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).10. Place the adsorption column in a new centrifuge tube (provided by oneself) and add 50-200 to the middle of the adsorption column in the air µ L Buffer GE or sterilized water, leave at room temperature for 2-5 minutes, centrifuge at 12000 rpm for 1 minute, collect DNA solution, and store DNA at -20 ℃.Note: 1) If downstream experiments are sensitive to pH or EDTA, they can be washed off with sterilized water. The pH value of the eluent has a significant impact on the elution efficiency. If water is used as the eluent, its pH value should be ensured to be between 7.0-8.5 (NaOH can be used to adjust the pH value of the water to this range). When the pH value is below 7.0, the elution efficiency is not high.2) Incubating at room temperature for 5 minutes before centrifugation can increase yield.3) Use an additional 50-200 µ Re washing with L Buffer GE or sterilized water can increase yield.4) If you want to increase the final concentration of DNA, you can add the DNA eluent obtained in step 10 back onto the adsorption membrane and repeat step 10; If the elution volume is less than 200 µ L. It is possible to increase the final concentration of DNA, but it may reduce the total yield. If the amount of DNA is less than 1 µ g. Recommended 50 µ L Buffer GE or off... Read More | N665917 Component 1 mL 5 mL Storage N665917A 2×SYBR qPCR MasterMix 1 mL 5×1 mL -20℃. Avoid freeze/ Thaw cycle. N665917B qPCR Primer Mix 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917C DNA Standard A 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917 Component 1 mL 5 mL Storage N665917A 2×SYBR qPCR MasterMix 1 mL 5×1 mL -20℃. Avoid freeze/ Thaw cycle. N665917B qPCR Primer Mix 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917C DNA Standard A 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917D DNA Standard B 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917E DNA Standard C 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917F DNA Standard D 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917G DNA Standard E 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917H 50×High ROX 40 µL 200 µL -20℃. Avoid freeze/ Thaw cycle.Product IntroductionThis is a dye-based (SYBR Green I) qPCR NGS library quantification kit for cfDNA, which provides the reaction mixture, DNA primer mixture, standards, and sample dilutions required for the qPCR process, making it a complete reagent system that is easy and convenient to use. The fluorescent dye SYBR Green I contained in the reaction mixture binds to all double-stranded DNA. The kit uses a new chemically modified high-efficiency hot-start polymerase, the activation of the enzyme needs to be incubated at 95 ℃ for 10 min. the product is highly specific, high amplification efficiency, the length of the standard in the kit (about 270bp) is comparable to the average length of the cfDNA NGS libraries (250-300bp), which is able to quickly and accurately quantitate the concentration of the constructed cfDNA libraries. quantification.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used in Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument.Instruments that do not require ROX calibration: Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96, etc.Instruments requiring Low ROX calibration: ABI Prism7500/7500 Fast, QuantStudio®3 System, QuantStudio®5 System, QuantStudio®6 Flex System, QuantStudio®7 Flex System, ViiA7 System, Stratagene Mx3000/Mx3005P, Corbett Rotor Gene 3000, and others.Instruments requiring High ROX calibration: ABI Prism7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, etc.NOTE: High Rox and Low Rox are formulated as described in Method of Use 2.Applicable scopeThis product is designed for the absolute quantification of the concentration of Illumina platform second generation sequencing libraries. The end of the library contains Illumina P5 and P7 microarray binding sequences, the length of which does not exceed 1kb, and the concentration is not less than 0.02pM can be used for quantitative experiments. The qPCR Primer Mix provided in the kit contains the following two primer sequences:Primer 1:5'-AAT GAT ACG GCG ACC ACC GA-3' Primer 2: 5'-CAA GCA GAA GAC GGC ATA CGA-3'The primer sequence can be used in advance to confirm whether the library can be amplified by that primer pair.UsageAmplification template preparationThe library samples to be detected were diluted with TE (10 mM Tris-Cl, pH 8.0, 1 mM EDTA), and the concentration after dilution was as close as possible to the range of 0.01-60 pM. 4°C on ice was set aside.qPCR reaction system preparationThe desired cryopreservation reagent is pre-melted completely and mixed by inverting several times before preparation, then centrifuged briefly and set aside.The base reaction system for 20 µl was as follows:Reagent20 µl Reaction system2×SYBR qPCR MasterMix10 µlqPCR Primer Mix0.8 µlTemplate4 µlddH₂O5.2 µlDescription: High Rox model: 1 µl High Rox per 50 µl of reaction system; Low Rox model: 1 µl High Rox per 500 µl of reaction system.Prepare a sufficient amount of reaction system mixture according to the need, mix well and add to the reaction wells in a volume of 16 µl per well, add the same volume of TE to the blank control, and then add the prepared standards and diluted samples to the corresponding reaction wells in a volume of 4 µl/well. It is recommended to use 20 µl reaction system, if you need to carry out a smaller system reaction, the system components can be reduced in equal proportion.3.qPCR reaction programIf the average length of the library is greater than 700bp, the annealing/extension time should be increased appropriately.Refer to the specific instrument setup program for dissolution curves.data analysisStandard curve productionThe standard curve was plotted according to the data processing Excel sheet. The correlation coefficient R2 of the standard curve should be not less than 0.99, and the slope should be located between -3.1 and -3.6 when the Ct value is the longitudinal coordinate. If the parameters of the standard curve are unreasonable, it is recommended to repeat the experiment.DNA Standard NameDNA Standard ConcentrationDNA Standard A60 pMDNA Standard B6 pMDNA Standard C0.6 pMDNA Standard D0.06 pMDNA Standard E0.006 pMLibrary Concentration CalculationsThe difference in Ct between the three replicate wells of the experiment should be no more than 0.2, otherwise the invalid data should be deleted or the experiment should be repeated. Do not use the Ct outside the valid Ct range of the standard curve to calculate the concentration of the diluted libraries. Please refer to the data processing Excel of this product for the specific library concentration calculation method.matters needing attentionThese instructions should be read in detail before testing. It should be carried out by personnel with specialized experience or qualified by training.Mix gently by turning up and down, avoid foaming as much as possible, and centrifuge for a short time before use.Avoid repeated freezing and thawing of this product; repeated freezing and thawing may degrade product performance.When preparing reaction solutions, use new or non-contaminated tips and centrifuge tubes to prevent contamination as much as possible... Read More |