| Description | Hydrogen peroxide (H₂O₂) is the most common reactive oxygen species (ROS) in living organisms. It is a by-product of active oxygen metabolism, primarily produced by enzymes like SOD and XOD, and degraded by enzymes such as CAT and POD. H₂O₂ is not only a significant ROS but Hydrogen peroxide (H₂O₂) is the most common reactive oxygen species (ROS) in living organisms. It is a by-product of active oxygen metabolism, primarily produced by enzymes like SOD and XOD, and degraded by enzymes such as CAT and POD. H₂O₂ is not only a significant ROS but also a hub for the interconversion of reactive oxygen species. On one hand, H₂O₂ can directly or indirectly oxidize biological macromolecules like nucleic acids and proteins within cells, damaging cell membranes and thereby accelerating cellular aging and disintegration. On the other hand, H₂O₂ is also a key regulatory factor in many oxidative stress responses. It can activate factors like NF-κB, and these H₂O₂-related signaling pathways are associated with many diseases such as asthma, inflammatory arthritis, arteriosclerosis, and neurodegenerative diseases. H₂O₂ is also closely related to processes like cell apoptosis and proliferation.Detection Principle: H₂O₂ oxidizes ferrous ions (Fe²⁺) to ferric ions (Fe³⁺). The Fe³⁺ then forms a purple complex with xylenol orange in a specific solution. The absorbance at 580 nm is directly proportional to the H₂O₂ concentration, allowing for the quantification of H₂O₂ levels.Detection Range: 1-100 µMSensitivity: 1 µMApplicable Samples: Animal/plant tissues, cells, bacteria, serum (plasma), urine.H1492752Component96T480TStorageH1492752AReaction Buffer5 mL25 mL-20℃. Store in the dark.H1492752BH₂O₂ Standard (1M)0.1 mL0.1 mL-20℃. Store in the dark.H1492752CAssay Buffer (10×)13 mL65 mL2-8℃Please check the quantity of each component before the experiment.An additional 10% of each component is provided beyond the specified volume for standard curve preparation or preliminary experiments.User-Provided Instruments and ReagentsTypeNameNotesInstrumentMicroplate ReaderCapable of measuring absorbance at 580 nm.Consumables96-well Microplate / Ultrafiltration tubesStandard transparent plate / 10 kDa MWCOReagentsPBS (pH 7.4) / Deionized Water / 30% ZnSO₄ solutionFor washing cells/bacteria / Reagent preparation / Protein removalOthersHomogenizer (for tissue samples), incubator, ice bucket, low-temperature centrifuge, adjustable pipettes and tipsUsing a multichannel pipette for large-scale detection can improve efficiency.Experimental Procedure1. Reagent PreparationReagent NameReagent PreparationPrecautionsReaction BufferReady-to-use; equilibrate to room temperature before use.Protect from light during the experiment; aliquot and store at -20°C in the dark.H₂O₂ Standard (1M)Ready-to-use; equilibrate to room temperature before use.Protect from light during the experiment; aliquot and store at -20°C in the dark.Assay Buffer (1×)Dilute the 10× Assay Buffer 1:10 with deionized water before use; equilibrate to room temperature.The diluted buffer can be stored at 4°C for at least 2 months. Used for diluting H₂O₂ standard and samples.2. Standard PreparationStandard Curve Setup:First, prepare a 2 mM H₂O₂ Standard: Dilute 2 µL of the 1M H₂O₂ Standard with 998 µL of Assay Buffer (1×).Then, prepare a 100 µM H₂O₂ Standard: Dilute 50 µL of the 2 mM H₂O₂ Standard with 950 µL of Assay Buffer (1×).Using the 100 µM H₂O₂ Standard, prepare further dilutions as shown in the table below.Prepare fresh standard solutions for each experiment.Prepared standards must be used within 4 hours.If the sample is a cell suspension, it is recommended to prepare the H₂O₂ standards using the culture medium.Standard Working Solution100µM Standard (µL)Assay Buffer (1×) (µL)Concentration (µM)1200010021001005034016020420180105101905641962721981Blank020003. Sample PreparationNote: Fresh samples are recommended. If not used immediately, samples can be stored at -80°C for up to 1 month. When ready for the experiment, thaw samples on ice. Note that this may affect sample stability, and results might be lower than expected. The following substances interfere with detection and should be avoided in samples: Ferric salts, iron salts, sucrose, glucose, ascorbic acid, SDS (>0.2%), sodium azide.3.1 Animal Tissues:Wash the tissue with cold PBS to remove as much blood as possible. Blot dry, weigh 0.1 g, and add 1 mL of pre-cooled Assay Buffer (1×). Homogenize the sample on ice. Centrifuge at 10000 g, 4°C for 5 min. Collect the supernatant and keep on ice for detection.3.2 Plant Tissues:Weigh approximately 0.1 g of sample, add 1 mL of pre-cooled Assay Buffer (1×), and grind. Disrupt by ultrasound on ice (power 20% or 200 W, ultrasonicate for 3 s, interval 7 s, repeat 30 times). Centrifuge at 10000 g, 4°C for 5 min. Collect the supernatant and keep on ice for detection.3.3 Cells/Bacteria:Collect 5×10⁶ cells or bacteria. Wash with cold PBS, then add 1 mL of pre-cooled Assay Buffer (1×). Homogenize on ice or disrupt by ultrasound on ice (power 20% or 200 W, ultrasonicate for 3 s, interval 7 s, repeat 30 times). Centrifuge at 10000 g, 4°C for 5 min. Collect the supernatant and keep on ice for detection.3.4 Plasma, Serum, and Urine (and other biological fluids):Remove proteins and use the supernatant. Protein removal methods:Use a 10 kDa ultrafiltration tube: filter and collect the filtrate.Mix sample : 30% ZnSO₄ solution = 20 : 1, vortex, then centrifuge at 10000 g, room temperature for 5 min, and collect the supernatant.4. Assay Steps4.1 Microplate Reader Preparation: Preheat for at least 30 minutes, set wavelength to 580 nm.4.2 Assay System Setup:ReagentStandard Well (µL)Test Well (µL)Standard (various conc.)600Sample060Reaction Buffer40404.3 Mix the reaction system thoroughly and incubate at 37°C for 10 minutes.4.4 Absorbance Measurement: Read the absorbance at 580 nm, recorded as A blank, A standard, and A test. 5. Result CalculationThe following provides both the derived formula and the simplified calculation formula, which are completely equivalent.5.1 Data ProcessingCalculate ΔA standard = A standard - A blank, ΔA test = A test - A blank. 5.2 Standard Curve PlottingPlot the standard curve with standard concentration as the y-axis and ΔA <sub> standard </sub> as the x-axis. Substitute ΔA <sub> test </sub> into the equation to obtain the y value (µM).5.3 Sample H₂O₂ Concentration Calculation(1) Based on sample mass:H₂O₂ Content (nmol/g fresh weight) = y × V sample ÷ (W × V sample ÷ V total ) × n = y ÷ W × n(2) Based on cell or bacterial count:H₂O₂ Content (nmol/10⁴ cells) = y × V sample ÷ (500 × V sample ÷ V total ) × n = y ÷ 500 × n(3) Based on liquid volume:H₂O₂ Content (nmol/mL) = y × V sample ÷ V sample × n = y × nParameter Description:1 µM = 1 nmol/mL;V sample : Volume of sample added;V total : Volume of Assay Buffer (1×) added, 1 mL;n: Sample dilution factor;W: Sample mass, g;500: Cell or bacterial count, in units of 10⁴.6. Result PresentationTypical Standard Curve: y = 207.21x + 1.4921, R² = 0.9988Example-1: 0.1 g of corn tissue was processed and assayed according to the procedure using a 96-well plate.Measured: ΔA test = A test - A blank = 0.278 - 0.048 = 0.230Substituting into the standard curve gives y = 49.15 µM.Calculated based on sample mass:H₂O₂ Content (nmol/g) = y ÷ W × n = 491.5 nmol/g.Precautions1. It is recommended to perform preliminary experiments using 2-3 samples expected to have significant differences before formal testing.2. This kit is compatible with spectrophotometer detection. Adjust the preparation volume of detection reagents proportionally according to the spectrophotometer's requirements.3. It is recommended to establish your own standard curve for improved accuracy. If not, you may refer to the typical standard curve formula provided in the results section for calculation.4. Biochemical reagents are generally irritating and biologically toxic. For your safety and health, please wear appropriate personal protective equipment (lab coat, mask, gloves, hair cap, etc.) throughout the experiment and perform experiments in a fume hood or biosafety cabinet.5. This product is for scientific research use only. Not intended for clinical diagnosis.Frequently Asked QuestionsQ: What should I do if the sample ΔA <sub> test </sub> is too high or too low?A: If the sample ΔA test is greater than the ΔA standard of the 100 µM standard, the H₂O₂ content in the sample is too high. Dilute the sample appropriately with Assay Buffer (1×) (multiply by the dilution factor in the calculation). If the sample ΔA test is less than 0.005, increase the sample amount... Read More | DescriptionThe 1 µm Coupling Kit makes conducting immunoprecipitation and biomolecule separation easier and more flexible. The Kit contains AnteoBind™activated 1 µm magnetic particles that give you increased antibody binding capacity and functionality, while the included blocking DescriptionThe 1 µm Coupling Kit makes conducting immunoprecipitation and biomolecule separation easier and more flexible. The Kit contains AnteoBind™activated 1 µm magnetic particles that give you increased antibody binding capacity and functionality, while the included blocking buffer decreases background noise. Reduce reagent preparation time; remove traditional surface preparation steps such as EDC and replace these steps with the 1 µm pre-activated magnetic particles provided. This Kit reduces aggregation and gives you the freedom and ability to develop multifunctional particles for diverse applications, including dual labelling.Binding Capacity and Dispersity:Binding Capacity:> 20 µg IgG/mgMonodispersity:> 90% (by light microscopy determination)Particle based immunoassays, bioseparations and immunoprecipitation... Read More | This product is a cDNA first strand synthesis kit specially prepared for the first step experiment of two-step RT-PCR. This product contains all the reagents required for reverse transcription from RNA templates to cDNA first strand, including HiFi MMLV reverse transcriptase, reaction buffer, This product is a cDNA first strand synthesis kit specially prepared for the first step experiment of two-step RT-PCR. This product contains all the reagents required for reverse transcription from RNA templates to cDNA first strand, including HiFi MMLV reverse transcriptase, reaction buffer, primers, dNTP, etc. The mutated HiFi MMLV reverse transcriptase RNase H activity is deficient, reducing RNA degradation in reverse transcription reactions and making it easier to obtain full-length cDNA. HiFi MMLV reverse transcriptase has strong thermal stability and can yield high yields of cDNA, making it simple and convenient to use. This system has high compatibility with subsequent PCR and quantitative PCR experiments, and is suitable for various DNA polymerase reactions. H665693 Component 100 T Storage H665693A HiFi-MMLV, 200 U/µL 100 µL -20℃. Avoid freeze/thaw cycle. H665693B 5×RT Buffer 500 µL -20℃. Avoid freeze/thaw cycle. H665693C Primer Mix 240 µL -20℃. Avoid freeze/thaw cycle. H665693D dNTP Mix, 2.5 mM Each 500 µL -20℃. Avoid freeze/thaw cycle. H665693E DTT, 0.1 M 240 µL -20℃. Avoid freeze/thaw cycle. H665693F RNase-Free Water 1 mL -20℃. Avoid freeze/thaw cycle. Product features:·RNase H -: Mutated HiFi MMLv reverse transcriptase with reduced RNase H activity, making it easier to obtain full-length cDNA.·Easy to use: The reagent kit contains all the reagents required for reverse transcription, except for RNA templates.Notes:1. During the operation process, RNase contamination should be avoided to prevent RNA degradation or cross contamination during experiments. It is recommended to perform RNA operations in specialized areas, use specialized instruments and consumables, and have operators wear masks and disposable gloves, and frequently change gloves.2. Disposable plastic containers should be used as much as possible for experiments. If glass containers are used, they should be treated with a 0.1% DEPC (diethyl pyrocarbonate) aqueous solution at 37 ℃ for 12 hours, and sterilized under high pressure at 120 ℃ for 30 minutes before use. Alternatively, glass containers should be sterilized under dry heat at 180 ℃ for 60 minutes before use. The sterile water used in the experiment should be treated with 0.1% DEPC and then subjected to high-pressure sterilization.3. All reagents in this reagent kit should be gently mixed upside down before use, avoiding foaming as much as possible, and used after brief centrifugation. The enzymes involved should be returned to -20 ℃ as soon as possible after use to avoid repeated freeze-thaw cycles.If the initial amount of RNA is less than 50 ng, it is recommended to add RNA enzyme inhibitors (RNAsin). This kit is not provided.Usage:Attention: 10 ng-5 µ G Total RNA can establish 20 µ Reaction system, if the total RNA content is greater than 5 µ g. Please expand the reaction system proportionallyi Steps for reverse transcription:1. Dissolve RNA templates, primers, dNTP Mix, DTT, RT Buffer, HiFi MMLV, and RNase Free Water and place on ice for later use.2. Prepare a reaction system according to the following table, with a total volume of 20 µ L. Reagent 20 µlReaction system Final concentration dNTP Mix,2.5 mM Each 4 µl 500 µM Each Primer Mix 2 µl / RNA Template X µl 1 ng-5 µg 5×RT Buffer 4 µl 1× DTT,0.1 M 2 µl 10 mM HiFi-MMLV,200 U/µl 1 µl / RNase-Free Water up to 20 µl / Attention:1) If the initial amount of RNA is less than 50 ng, it is recommended to add RNA enzyme inhibitors (RNAsin). This kit is not provided.2) Primer Mix is formulated from Oligo (dT) and Random Primer3. Vortex shake and mix well, briefly centrifuge to collect the solution on the pipe wall to the bottom of the pipe. 4. Incubate at 42 ℃ for 30-50 minutes and 85 ℃ for 5 minutes. After the reaction is complete, centrifuge briefly and cool on ice.5. Reverse transcripts can be directly used for PCR reactions and fluorescence quantitative PCR reactions, or stored at -20 ℃ for a long time.ii If the reverse transcription efficiency is low, or the RNA template secondary structure is complex and the GC content is high, the following steps are recommended:1. Dissolve RNA templates, primers, dNTP Mix, DTT, RT Buffer, HiFi MMLV, and RNase Free Water and place on ice for later use.2. Prepare the reaction system according to the following table, with a total volume of 13 µ L. Reagent 20 µlReaction system Final concentration dNTP Mix,2.5 mM Each 4 µl 500 µM Each Primer Mix 2 µl / RNA Template X µl 1 ng-5 µg RNase-Free Water up to 13 µl / 3. Incubate at 70 ℃ for 10 minutes and quickly ice bath for 2 minutes.4. Centrifuge briefly to collect the solution on the tube wall to the bottom of the tube.5. Continue to add the following reagents to the above reaction solution: Reagent 20 µlReaction system Final concentration 5×RT Buffer 4 µl 1× DTT,0.1 M 2 µl 10 mM HiFi-MMLV,200 U/µl 1 µl / Attention:1) If the initial amount of RNA is less than 50 ng, it is recommended to add RNA enzyme inhibitors (RNAsin). This kit is not provided.2) Primer Mix is formulated from Oligo (dT) and Random primer.6. Gently blow and mix well, incubate at 42 ℃ for 50 minutes, and incubate at 85 ℃ for 5 minutes.7. After the reaction is complete, centrifuge briefly and cool on ice.8. Reverse transcripts can be directly used for PCR reactions and fluorescence quantitative PCR reactions, or stored at -20 ℃ for a long time... Read More | The miRNA extraction kit is specifically designed to isolate and purify miRNAs from various animal tissues, plant tissues, cells, serum, plasma and other samples. It can also extract small molecule RNAs such as siRNA and snRNA that are less than 200 nt, and can also be used for the extraction of The miRNA extraction kit is specifically designed to isolate and purify miRNAs from various animal tissues, plant tissues, cells, serum, plasma and other samples. It can also extract small molecule RNAs such as siRNA and snRNA that are less than 200 nt, and can also be used for the extraction of total RNA. This product combines phenol/guanidine lysis technology and silicon matrix membrane purification technology. The unique lysis solution can effectively inhibit RNases while removing most of DNA and proteins from cell or tissue samples through organic extraction. For some sensitive downstream experiments, if miRNA enrichment is required, this kit can be used to enrich miRNA separately. This product is suitable for a wide range of samples, with high purity of prepared RNA, and can be directly used for sensitive downstream applications, such as Northern Blot analysis, Real Time PCR, Microarray Analysis, etc. M665531Component50 TStorageM665531ATRIzon Reagent60 mL2-8℃. Protect from ligt.M665531BBuffer RWT (concentrate)15 mLRTM665531CBuffer RW2 (concentrate)11 mLRTM665531DRNase-Free Water10 mLRTM665531ESpin Columns RM with Collection Tubes50 setsRTM665531FSpin Columns RS with Collection Tubes50 setsRTM665531GRNase-Free Centrifuge Tubes (1.5 mL)50 EART Self prepared reagents: chloroform, anhydrous ethanol (newly opened or dedicated for RNA extraction).Preparation and important precautions before the experiment:To prevent RNase pollution, attention should be paid to the following aspects:1) Use RNase free plastic products and gun heads to avoid cross contamination.2) Glassware should be dry baked at a high temperature of 180 ℃ for 4 hours before use, while plastic containers can be soaked in 0.5 M NaOH for 10 minutes, thoroughly rinsed with water, and then sterilized under high pressure.3) Prepare the solution using water without RNase.4) Operators should wear disposable masks and gloves, and change gloves frequently during the experiment.2. The extracted samples should avoid repeated freeze-thaw cycles, otherwise it will affect the quantity and quality of miRNA extraction.Before the first use, anhydrous ethanol should be added to Buffer RWT and Buffer RW2 according to the instructions on the reagent bottle label.4. All centrifugation steps should be carried out at room temperature unless otherwise specified, and all operation steps should be carried out quickly.Operation steps:Protocol A: miRNA enrichment (can be directly used for sensitive downstream experiments)1. Sample processing1a Organization: Grind the organization in liquid nitrogen. Add 1 ml of TRIzon Reagent to every 30-50 mg of tissue, shake and mix well. The sample volume shall not exceed one tenth of the volume of TRIzon Reagent.1b Single layer culture of cells: Remove the culture medium, add TRIzon Reagent, and add 1 ml of TRIzon Reagent every 10 cm2 (the amount of lysis solution depends on the area of the culture bottle).1c Cell suspension: Centrifuge to obtain cell precipitate, discard supernatant. Add 1 ml of TRIzon Reagent to every 5 x 106-1 x 107 cells (cells do not require washing).1d Plasma or serum: Take 200 µ Add 5 times the volume of TRIzon Reagent to plasma or serum samples, shake and mix well for 30 seconds.2. After adding TRIzon Reagent to the sample, blow it repeatedly several times to fully crack it. Leave at room temperature for 5 minutes to completely separate the protein nucleic acid complex.3. Optional steps: Centrifuge at 4 ℃ 12000 rpm (~13400 × g) for 5 minutes, take the supernatant, and transfer it to a new centrifuge tube (provided by oneself) (if the sample contains more proteins, fats, polysaccharides, etc., this step can be performed).4. Add chloroform to the supernatant and add 200 to every 1 ml of TRIzon Reagent used µ Chloroform, cover the tube, vigorously shake for 15 seconds, and let it sit at room temperature for 5 minutes.Centrifuge at 5.4 ℃ and 12000 rpm for 15 minutes. The sample is divided into three layers: red organic phase, middle layer, and colorless aqueous phase. Transfer the upper colorless aqueous phase to a new centrifuge tube (self prepared).6. Add 1/3 volume of anhydrous ethanol to the solution obtained in step 5, mix well, and transfer the obtained solution and precipitate together into the adsorption column RM (Spin Columns RM) that has been loaded into the collection tube. If you cannot add all the solution to the adsorption column at once, please transfer it multiple times. Centrifuge at 12000 rpm for 30 seconds, discard the adsorption column RM after centrifugation, and retain the effluent.7. Add 2/3 times the volume of anhydrous ethanol to the solution obtained in step 6 and mix well.8. Transfer the solution and precipitate obtained from the previous step into the adsorption column RS (Spin Columns RS) that has been loaded into the collection tube. If you cannot add all the solution to the adsorption column at once, please transfer it multiple times. Centrifuge at 12000 rpm for 30 seconds, discard the waste liquid in the collection tube, and place the adsorption column RS back into the collection tube.9. Add 700 to the adsorption column RS µ L Buffer RWT (check if anhydrous ethanol is added before use), centrifuge at 12000 rpm for 30 seconds, discard the waste liquid in the collection tube, and place the adsorption column RS back into the collection tube.10. Add 500 to the adsorption column RS µ Buffer RW2 (check if anhydrous ethanol is added before use), centrifuge at 12000 rpm for 30 seconds, discard the waste liquid in the collection tube, and place the adsorption column RS back into the collection tube.11. Repeat step 10.12. Centrifuge at 12000 rpm for 1 minute and discard the waste liquid from the collection tube. Place the adsorption column RS at room temperature for a few minutes to thoroughly air dry. Note: The purpose of this step is to remove residual ethanol from the adsorption column RS, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).13. Place the adsorption column RS in a new RNase free centrifuge tube and add 30-50 to the middle of the adsorption column µ Place RNase Free Water at room temperature for 1 minute, centrifuge at 12000 rpm for 1 minute, collect RNA solution, and store the obtained RNA solution at -70 ℃ to prevent degradation.Attention:1) The volume of RNase Free Water should not be less than 30 µ l. Small volume affects the recovery rate.2) If you want to increase RNA production, you can use 30-50 µ Repeat step 13 for the new RNase Free Water.3) If you want to increase the RNA concentration, you can add the obtained solution back to the adsorption column RS and repeat step 13Protocol B: Extraction of total RNA (including miRNA and other small molecule RNAs<200 nt), steps 1-5 are the same as protocol A.6. Add 1.25 times the volume of anhydrous ethanol to the solution obtained in step 5 and mix well.7. Transfer the solution and precipitate obtained from the previous step into the spin columns RM that have been loaded into the collection tube. If you cannot add all the solution to the adsorption column RM at once, please transfer it multiple times. Centrifuge at 12000 rpm for 30 seconds, discard the waste liquid in the collection tube, and place the adsorption column RM back into the collection tube.8. Add 700 to the adsorption column RM µ L Buffer RWT (check if anhydrous ethanol is added before use), centrifuge at 12000 rpm for 30 seconds, discard the waste liquid in the collection tube, and place the adsorption column RM back into the collection tube.9. Add 500 to the adsorption column RM µ Buffer RW2 (check if anhydrous ethanol is added before use), centrifuge at 12000 rpm for 30 seconds, discard the waste liquid in the collection tube, and place the adsorption column RM back into the collection tube.10. Repeat step 9.11. Centrifuge at 12000 rpm for 1 minute and discard the waste liquid from the collection tube. Place the adsorption column RM at room temperature for a few minutes to thoroughly air dry. Attention: The purpose of this step is to remove residual ethanol from the adsorption column RM, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).12. Transfer the adsorption column RM into a new RNase free centrifuge tube and add 30-50 to the middle of the adsorption column µ Place RNase Free Water at room temperature for 1 minute, centrifuge at 12000 rpm for 1 minute, collect RNA solution, and store the obtained RNA solution at -70 ℃ to prevent degradation. Attention: 1) The volume of RNase Free Water should not be less than 30 µ l. Small volume affects the recovery rate.2) If you want to increase RNA production, you can use 30-50 µ Repeat step 12 for the new RNase Free Water.3) If you want to increase the RNA concentration, you can add the obtained solution back to the adsorption column RM and repeat step 12... Read More | Products contentN665737Component24 T96 TStorageN665737ATPS V50 168 µL672 µL-20℃. Avoid freeze/thaw cycle.N665737B5×FA Reaction Buffer96 µL384 µL-20℃. Avoid freeze/thaw cycle.N665737CTS Buffer72 µL288 µL-20℃. Avoid freeze/thaw cycle.N665737D2×Products contentN665737Component24 T96 TStorageN665737ATPS V50 168 µL672 µL-20℃. Avoid freeze/thaw cycle.N665737B5×FA Reaction Buffer96 µL384 µL-20℃. Avoid freeze/thaw cycle.N665737CTS Buffer72 µL288 µL-20℃. Avoid freeze/thaw cycle.N665737D2×PCR Mix600 µL2×1.2 mL-20℃. Avoid freeze/thaw cycle. * This kit is suitable for human genomic DNA library construction, the starting template DNA input is 5 ng. We also have transposase library construction kits for 50 ng and 1 ng of human genomic DNA starting, in order to get a higher quality library, it is recommended to use different kits for different starting amount of DNA. Products IntroductionThis kit is developed for Illumina's high-throughput sequencing platform and provides the enzyme premix system and reaction buffer for genomic DNA library construction, including all components except PCR primers. Compared with the traditional library construction kits, this kit adopts the new transposase method for library construction, which can complete DNA fragmentation, end repair and junction reaction in one simple enzymatic reaction, significantly reducing the amount of template, reducing the number of experimental steps, and shortening the time of library construction; it adopts the high-fidelity DNA polymerase for library enrichment, and the preference-free PCR amplification can expand the coverage area of the sequence, which can be used for efficient and effective sequencing. The use of high-fidelity DNA polymerase for library enrichment and preference-free PCR amplification broadens the coverage area of the sequence and enables efficient preparation of DNA libraries for Illumina's second-generation sequencing platform. The kit is suitable for use with a starting template DNA input of 5 ng, and all reagents in the kit have been subjected to stringent quality control and functional validation to maximize the stability and reproducibility of library construction. Product Features● DNA fragmentation and junction ligation in one step.● Ultra-fidelity amplification minimizes amplification preference.Provide your own instruments, kits and consumables1. Magnetic frame: DynaMagTM-2 is recommended.2. DNA purification and recovery kit: It is recommended to use DNA purification and recovery kit by magnetic bead method.3. Library PCR primer kit: It is recommended to use transposase method for second generation sequencing multi-sample primer kit.4. Anhydrous ethanol, deionized water (pH between 7.0 and 8.0).5. Reaction tubes: It is recommended to use low adsorption PCR tubes and 1.5 ml centrifuge tubes. Tips: It is recommended to use high quality filter tips to prevent contamination of kits and library samples. Pre-experiment Preparation and Important Notes1. Avoid repeated freezing and thawing of reagents.2. PCR products are easily contaminated due to improper operation, resulting in inaccurate results. It is recommended to isolate the PCR reaction system preparation area from the PCR product purification area, and to use special pipettes to clean the experimental areas at regular intervals.3. Bead purification: the beads should be equilibrated to room temperature before use, all operations on the beads should be carried out at room temperature, 80% ethanol should be dispensed freshly, the beads should be rinsed and dried until the surface is free of liquid reflections and has a frosted appearance, insufficient drying of the beads will cause ethanol residue that will affect the subsequent experiments, and over-drying of the beads will affect the efficiency of DNA recovery.4. The kit is suitable for human genomic DNA library construction, if the DNA sample is a PCR product, it should be ensured that its length>.500 bp, since transposases do not work on DNA ends, it is recommended to extend the PCR product by 50-100 bp at each end of the PCR product to avoid low coverage of the ends for sequencing. Sample PreparationDNA purity requirements: A260/A280 = 1.8-2.0. Sample DNA: dissolve in ultrapure water. DNA Quantification: Too much or too little DNA will affect the quality of the library. It is recommended to use Nano to test the purity of the genomic DNA and then use Qubit to test the concentration of the genome (do not use any absorbance-based assay for template quantification). Schematic diagram of DNA banking processprocedureDNA fragmentation, junction reaction 1. Add the following reagents to a 200 µl PCR tube: 2. Mix by gently blowing with a pipette and centrifuge briefly so that all components are collected at the bottom of the tube.3. Place the above PCR tubes in the PCR instrument with the hot cap on and program the reaction as follows: inactivation reactionAfter the DNA is fragmented, the enzyme is still in a high active state, so it should be removed from the PCR instrument immediately and terminated by adding the Reaction Termination Buffer, in order to prevent the DNA from being fragmented too much and resulting in smaller library fragments.1. Add 3 µl of TS Buffer to the PCR tube containing the fragmentation product.2. Mix by gently blowing with a pipette and centrifuge briefly so that all components are collected at the bottom of the tube.3. Incubate at room temperature for 5 min, or if the room temperature is too low, place the reaction on a PCR instrument at 25°C with the thermal cover closed.1. Add the following reagents to a 200 µl PCR tube.2. Mix by gently blowing with a pipette and centrifuge briefly so that all components are collected at the bottom of the tube.3. Place the above PCR tubes in the PCR instrument with the hot cap on and program the reaction as follows Selective recovery of library DNA fragmentsIt is recommended to use CombiVision Magnetic Beads DNA Purification and Recovery Kit for selective recovery of DNA fragments. When different sizes of DNA fragments are required, the amount of magnetic beads used is different, please refer to the attached table for the specific amount of magnetic beads used.(If using other brands of magnetic beads, you need to figure out the optimal amount of magnetic beads by yourself).Note: Amplification products can also be fragment length sorted and purified using the Gum Recovery Kit. If there is no special requirement for library length distribution, amplification products can also be purified directly from DNA fragments without selective recovery of DNA fragments as described on page 4 of the manual.1. CMPure should be equilibrated at room temperature for 30 min after shaking and mixing before use.2. Transfer the PCR products to a 1.5 ml centrifuge tube, rehydrate to 100 µl, add several volumes of magnetic beads equilibrated to room temperature, vortex for 5 seconds, and let stand at room temperature for 5 minutes.3. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant until the solution is clear, and carefully aspirate the supernatant and transfer it to a new 1.5 ml centrifuge tube.Note: Do not discard the top clear.4. Add several volumes of magnetic beads to the supernatant, vortex and shake for 5 seconds, then let stand at room temperature for 5 minutes.5. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant until the solution is clear, carefully aspirate the supernatant and discard it, avoiding contact with the beads that have bound the target DNA.Note: Do not discard the beads.6. Continue to keep the centrifuge tube fixed on a magnetic rack and add 200 µl of freshly prepared 80% ethanol to the tube and allow to stand at room temperature for 30 seconds, carefully discarding the supernatant.Note: When adding ethanol, the liquid must not be blown directly onto the beads.7. Repeat step 6 once.8. Keep the centrifuge tube fixed on a magnetic rack and leave to dry at room temperature until the surface of the beads is slightly cracked, add 20 µl of ddH2O to solubilize.Note: Do not over-dry the beads as this may affect the elution efficiency.9. Remove the centrifuge tube from the magnetic rack, vortex to completely resuspend the beads, and allow to stand at room temperature for 5 minutes. Centrifuge briefly, place the tube on the magnetic rack until the solution is clear, and transfer the supernatant solution to a new centrifuge tube. Table: Suggested amount of magnetic beads for different segment selection recovery Library DNA fragment purificationWe recommend the use of the Century Magnetic Bead Method DNA Purification and Recovery Kit.1. CMPure should be equilibrated at room temperature for 30 min after shaking and mixing before use.2. 50 µl of magnetic beads equilibrated to room temperature were added to the PCR product, vortexed and shaken for 5 seconds, and then left to stand at room temperature for 5 minutes.3. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant solution until the solution is clear (approximately 3-5 minutes), carefully aspirate the supernatant and discard it, avoiding contact with the beads that have bound the target DNA. Note: Do not discard the beads.4. Continue to keep the centrifuge tube fixed on a magnetic rack and add 200 µl of freshly prepared 80% ethanol to the centrifuge tube and allow to stand at room temperature for 30 seconds, carefully discarding the supernatant.Note: When adding ethanol, the liquid must not be blown directly onto the beads.5. Repeat step 4.6. Keep the centrifuge tube fixed on a magnetic rack and leave to dry at room temperature until the surface of the beads is slightly cracked, add 25 µl of ddH O to solubilize.Note: Do not over-dry the beads as this may affect the elution efficiency.7. Remove the tube from the magnetic rack, vortex to completely resuspend the beads, and allow to stand at room temperature for 5 minutes. Centrifuge briefly, place the tube on the magnetic rack until the solution is clear, and transfer the supernatant solution to a new tube. Library quality controlDetermination of library concentrationIn order to obtain high-quality sequencing results, accurate quantification of DNA libraries is required, and the first recommendation is to use Real-timePCR methods are used for absolute quantification of DNA libraries. Additionally, fluorescent dye methods such as the Qubit method or the fluorescent dye picogreen method can be used; do not use quantification methods based on absorbance measurements here. The following approximate formula can be used to convert the molar concentration of the DNA library. Library fragment distributionThe prepared DNA libraries can be detected by agarose gel electrophoresis or Agilent 2100 Bioanalyzer.Range of segment length distributions... Read More |