| Description | Hydrogen peroxide (H₂O₂) is the most common reactive oxygen species (ROS) in living organisms. It is a by-product of active oxygen metabolism, primarily produced by enzymes like SOD and XOD, and degraded by enzymes such as CAT and POD. H₂O₂ is not only a significant ROS but Hydrogen peroxide (H₂O₂) is the most common reactive oxygen species (ROS) in living organisms. It is a by-product of active oxygen metabolism, primarily produced by enzymes like SOD and XOD, and degraded by enzymes such as CAT and POD. H₂O₂ is not only a significant ROS but also a hub for the interconversion of reactive oxygen species. On one hand, H₂O₂ can directly or indirectly oxidize biological macromolecules like nucleic acids and proteins within cells, damaging cell membranes and thereby accelerating cellular aging and disintegration. On the other hand, H₂O₂ is also a key regulatory factor in many oxidative stress responses. It can activate factors like NF-κB, and these H₂O₂-related signaling pathways are associated with many diseases such as asthma, inflammatory arthritis, arteriosclerosis, and neurodegenerative diseases. H₂O₂ is also closely related to processes like cell apoptosis and proliferation.Detection Principle: H₂O₂ oxidizes ferrous ions (Fe²⁺) to ferric ions (Fe³⁺). The Fe³⁺ then forms a purple complex with xylenol orange in a specific solution. The absorbance at 580 nm is directly proportional to the H₂O₂ concentration, allowing for the quantification of H₂O₂ levels.Detection Range: 1-100 µMSensitivity: 1 µMApplicable Samples: Animal/plant tissues, cells, bacteria, serum (plasma), urine.H1492752Component96T480TStorageH1492752AReaction Buffer5 mL25 mL-20℃. Store in the dark.H1492752BH₂O₂ Standard (1M)0.1 mL0.1 mL-20℃. Store in the dark.H1492752CAssay Buffer (10×)13 mL65 mL2-8℃Please check the quantity of each component before the experiment.An additional 10% of each component is provided beyond the specified volume for standard curve preparation or preliminary experiments.User-Provided Instruments and ReagentsTypeNameNotesInstrumentMicroplate ReaderCapable of measuring absorbance at 580 nm.Consumables96-well Microplate / Ultrafiltration tubesStandard transparent plate / 10 kDa MWCOReagentsPBS (pH 7.4) / Deionized Water / 30% ZnSO₄ solutionFor washing cells/bacteria / Reagent preparation / Protein removalOthersHomogenizer (for tissue samples), incubator, ice bucket, low-temperature centrifuge, adjustable pipettes and tipsUsing a multichannel pipette for large-scale detection can improve efficiency.Experimental Procedure1. Reagent PreparationReagent NameReagent PreparationPrecautionsReaction BufferReady-to-use; equilibrate to room temperature before use.Protect from light during the experiment; aliquot and store at -20°C in the dark.H₂O₂ Standard (1M)Ready-to-use; equilibrate to room temperature before use.Protect from light during the experiment; aliquot and store at -20°C in the dark.Assay Buffer (1×)Dilute the 10× Assay Buffer 1:10 with deionized water before use; equilibrate to room temperature.The diluted buffer can be stored at 4°C for at least 2 months. Used for diluting H₂O₂ standard and samples.2. Standard PreparationStandard Curve Setup:First, prepare a 2 mM H₂O₂ Standard: Dilute 2 µL of the 1M H₂O₂ Standard with 998 µL of Assay Buffer (1×).Then, prepare a 100 µM H₂O₂ Standard: Dilute 50 µL of the 2 mM H₂O₂ Standard with 950 µL of Assay Buffer (1×).Using the 100 µM H₂O₂ Standard, prepare further dilutions as shown in the table below.Prepare fresh standard solutions for each experiment.Prepared standards must be used within 4 hours.If the sample is a cell suspension, it is recommended to prepare the H₂O₂ standards using the culture medium.Standard Working Solution100µM Standard (µL)Assay Buffer (1×) (µL)Concentration (µM)1200010021001005034016020420180105101905641962721981Blank020003. Sample PreparationNote: Fresh samples are recommended. If not used immediately, samples can be stored at -80°C for up to 1 month. When ready for the experiment, thaw samples on ice. Note that this may affect sample stability, and results might be lower than expected. The following substances interfere with detection and should be avoided in samples: Ferric salts, iron salts, sucrose, glucose, ascorbic acid, SDS (>0.2%), sodium azide.3.1 Animal Tissues:Wash the tissue with cold PBS to remove as much blood as possible. Blot dry, weigh 0.1 g, and add 1 mL of pre-cooled Assay Buffer (1×). Homogenize the sample on ice. Centrifuge at 10000 g, 4°C for 5 min. Collect the supernatant and keep on ice for detection.3.2 Plant Tissues:Weigh approximately 0.1 g of sample, add 1 mL of pre-cooled Assay Buffer (1×), and grind. Disrupt by ultrasound on ice (power 20% or 200 W, ultrasonicate for 3 s, interval 7 s, repeat 30 times). Centrifuge at 10000 g, 4°C for 5 min. Collect the supernatant and keep on ice for detection.3.3 Cells/Bacteria:Collect 5×10⁶ cells or bacteria. Wash with cold PBS, then add 1 mL of pre-cooled Assay Buffer (1×). Homogenize on ice or disrupt by ultrasound on ice (power 20% or 200 W, ultrasonicate for 3 s, interval 7 s, repeat 30 times). Centrifuge at 10000 g, 4°C for 5 min. Collect the supernatant and keep on ice for detection.3.4 Plasma, Serum, and Urine (and other biological fluids):Remove proteins and use the supernatant. Protein removal methods:Use a 10 kDa ultrafiltration tube: filter and collect the filtrate.Mix sample : 30% ZnSO₄ solution = 20 : 1, vortex, then centrifuge at 10000 g, room temperature for 5 min, and collect the supernatant.4. Assay Steps4.1 Microplate Reader Preparation: Preheat for at least 30 minutes, set wavelength to 580 nm.4.2 Assay System Setup:ReagentStandard Well (µL)Test Well (µL)Standard (various conc.)600Sample060Reaction Buffer40404.3 Mix the reaction system thoroughly and incubate at 37°C for 10 minutes.4.4 Absorbance Measurement: Read the absorbance at 580 nm, recorded as A blank, A standard, and A test. 5. Result CalculationThe following provides both the derived formula and the simplified calculation formula, which are completely equivalent.5.1 Data ProcessingCalculate ΔA standard = A standard - A blank, ΔA test = A test - A blank. 5.2 Standard Curve PlottingPlot the standard curve with standard concentration as the y-axis and ΔA <sub> standard </sub> as the x-axis. Substitute ΔA <sub> test </sub> into the equation to obtain the y value (µM).5.3 Sample H₂O₂ Concentration Calculation(1) Based on sample mass:H₂O₂ Content (nmol/g fresh weight) = y × V sample ÷ (W × V sample ÷ V total ) × n = y ÷ W × n(2) Based on cell or bacterial count:H₂O₂ Content (nmol/10⁴ cells) = y × V sample ÷ (500 × V sample ÷ V total ) × n = y ÷ 500 × n(3) Based on liquid volume:H₂O₂ Content (nmol/mL) = y × V sample ÷ V sample × n = y × nParameter Description:1 µM = 1 nmol/mL;V sample : Volume of sample added;V total : Volume of Assay Buffer (1×) added, 1 mL;n: Sample dilution factor;W: Sample mass, g;500: Cell or bacterial count, in units of 10⁴.6. Result PresentationTypical Standard Curve: y = 207.21x + 1.4921, R² = 0.9988Example-1: 0.1 g of corn tissue was processed and assayed according to the procedure using a 96-well plate.Measured: ΔA test = A test - A blank = 0.278 - 0.048 = 0.230Substituting into the standard curve gives y = 49.15 µM.Calculated based on sample mass:H₂O₂ Content (nmol/g) = y ÷ W × n = 491.5 nmol/g.Precautions1. It is recommended to perform preliminary experiments using 2-3 samples expected to have significant differences before formal testing.2. This kit is compatible with spectrophotometer detection. Adjust the preparation volume of detection reagents proportionally according to the spectrophotometer's requirements.3. It is recommended to establish your own standard curve for improved accuracy. If not, you may refer to the typical standard curve formula provided in the results section for calculation.4. Biochemical reagents are generally irritating and biologically toxic. For your safety and health, please wear appropriate personal protective equipment (lab coat, mask, gloves, hair cap, etc.) throughout the experiment and perform experiments in a fume hood or biosafety cabinet.5. This product is for scientific research use only. Not intended for clinical diagnosis.Frequently Asked QuestionsQ: What should I do if the sample ΔA <sub> test </sub> is too high or too low?A: If the sample ΔA test is greater than the ΔA standard of the 100 µM standard, the H₂O₂ content in the sample is too high. Dilute the sample appropriately with Assay Buffer (1×) (multiply by the dilution factor in the calculation). If the sample ΔA test is less than 0.005, increase the sample amount... Read More | DescriptionThe 1 µm Coupling Kit makes conducting immunoprecipitation and biomolecule separation easier and more flexible. The Kit contains AnteoBind™activated 1 µm magnetic particles that give you increased antibody binding capacity and functionality, while the included blocking DescriptionThe 1 µm Coupling Kit makes conducting immunoprecipitation and biomolecule separation easier and more flexible. The Kit contains AnteoBind™activated 1 µm magnetic particles that give you increased antibody binding capacity and functionality, while the included blocking buffer decreases background noise. Reduce reagent preparation time; remove traditional surface preparation steps such as EDC and replace these steps with the 1 µm pre-activated magnetic particles provided. This Kit reduces aggregation and gives you the freedom and ability to develop multifunctional particles for diverse applications, including dual labelling.Binding Capacity and Dispersity:Binding Capacity:> 20 µg IgG/mgMonodispersity:> 90% (by light microscopy determination)Particle based immunoassays, bioseparations and immunoprecipitation... Read More | Inquire | Products contentN665978Component384 TStorageN665978AIndex N502-N522 Primers for Illumina 16×24 µL-20℃. Avoid freeze/thaw cycle.N665978BIndex N701-N729 Primers for Illumina24×16 µL-20℃. Avoid freeze/thaw cycle. Products IntroductionThis kit is a companion to the Products contentN665978Component384 TStorageN665978AIndex N502-N522 Primers for Illumina 16×24 µL-20℃. Avoid freeze/thaw cycle.N665978BIndex N701-N729 Primers for Illumina24×16 µL-20℃. Avoid freeze/thaw cycle. Products IntroductionThis kit is a companion to the transposase-based rapid DNA library construction kit, designed for Illumina platform library construction. It contains 16 N5 primers and 24 N7 primers, which can be used to prepare 384 different bipartite Index libraries. All reagents provided in the kit have been subjected to stringent quality control and functional validation to maximize the stability and reproducibility of library construction. The libraries can be used for sequencing on Illumina platforms such as HiSeq X-10/4000/2500/2000 and MiSeq.Provide your own instruments, reagents and consumables1. Magnetic frame: DynaMagTM-2 is recommended.2. DNA purification and recovery kit: It is recommended to use Kangwei DNA purification and recovery kit by magnetic bead method.3. DNA building kit: It is recommended to use the Kangwei Century transposase method second-generation sequencing rapid DNA building kit.4. Anhydrous ethanol.5. Reaction tubes: It is recommended to use low adsorption PCR tubes with 1.5 ml centrifuge tubes; Tip: It is recommended to use a high quality filter tip to prevent contamination of kits and library samples. Pre-experiment Preparation and Important NotesPlease centrifuge briefly before opening the cap so that the liquid collects at the bottom of the tube to avoid cross-contamination between different primers.procedure For the use of the CombiVision Second Generation Sequencing Multisample Primer Kit, please follow the CombiVision Second Generation Sequencing Rapid DNA Library Kit protocol. Index N502-N522 Primers for Illumina Index N701-N729 Primers for Illumina... Read More | Product content: Component O66550510 preps O665505 50 preps Blocking Buffer 100 ml 500 ml Antibody Pretreat Solution( HRP/Mouse ) 1 ml 5 × 1 ml Dilution Buffer 100 ml 500 ml Wash Buffer( 10× ) 100 ml 500 mlProduct Introduction:The one-step rapid WB assay kit (Product content: Component O66550510 preps O665505 50 preps Blocking Buffer 100 ml 500 ml Antibody Pretreat Solution( HRP/Mouse ) 1 ml 5 × 1 ml Dilution Buffer 100 ml 500 ml Wash Buffer( 10× ) 100 ml 500 mlProduct Introduction:The one-step rapid WB assay kit (mouse) is the latest Western Blot detection kit developed by Kangwei Century, which can obtain high-quality Western Blot results in about 1 hour. It is easy to operate, has high detection sensitivity, low background, does not require the addition of secondary antibodies, and has strong system stability. The conventional Western Blot indirect detection process (blocking, primary antibody binding, and secondary antibody binding) requires a long time, a complex experimental process, and requires multi-step condition optimization. After transferring the protein on the gel to the carrier membrane, incubate it with the blocking solution in the reagent kit for 5 minutes, and then incubate the carrier membrane with the primary antibody treated with antibody reaction solution. After washing three times (5 minutes each time), luminescence or colorimetric detection can be performed. This reagent kit is designed for use in experimental systems where the target protein primary antibody is derived from mice.Notes:1. The customer prepares their own mouse source primary antibody.2. Before using Blocking Buffer blocking solution, Antibody Pretreat Solution (HRP/Mouse) antibody reaction solution (mouse), and Wash Buffer (10 x) rinse solution, please mix thoroughly.3. If there is precipitation in the rinsing solution when stored at 2-8 ℃, please restore it to room temperature, dissolve the precipitation, and use it normally. The 1x rinsing solution can be stored at room temperature for one month.4. It is recommended to stain the membrane with reagents such as spring red after the transfer is completed, and cut off any excess parts on the membrane to increase the efficiency of the reagents.5. The optimal dilution amount for primary antibody and antibody reaction solution HRP (mouse) needs to be determined through preliminary experiments.6. The antibody reaction solution HRP (mouse), antibody dilution solution, and antibody dosage can be increased or decreased proportionally according to the size of the membrane.7. The antibody dilution solution containing the first antibody can be recycled and reused once. It is recommended not to reuse antibodies with poor specificity and affinity. If the recovered antibody is used within 1-2 days and stored at 2-8 ℃ for long-term storage, please freeze it at -20 ℃ to avoid repeated freeze-thaw cycles.8. If there is a high background, please adjust the amount of antibodies and increase the number of times the film is washed.9. All reagents in the reagent kit should be stored at 2-8 ℃ to avoid freezing and thawing.Operation steps:This product is suitable for the sealing and antibody incubation steps after membrane transfer, taking a 5 cm x 8 cm membrane as an example:1. Preparation of rinsing solution: Dilute 10 ml of Wash Buffer (10 x) with distilled water to 100 ml, which is 1 x Wash Buffer. Set aside. Use 8-10 ml for each film wash.2. Sealing: After the membrane transfer is completed, immerse the membrane in 10 ml Blocking Buffer and seal at room temperature for 5 minutes.3. Rinse: Pour off the sealing solution, add 8-10 ml of 1 x Wash Buffer, and rinse at a high speed on a shaker for 1 minute.4. Prepare antibody incubation solution while washing the membrane: Take Antibody Pretreat Solution (HRP/Mouse) 100 µ Add mouse derived primary antibody 3-10 into the centrifuge tube µ g. Suck and beat the gun head until thoroughly mixed, and incubate at room temperature for 5 minutes. Add to 10 ml Dilution Buffer and mix well. Note: 1) The dosage of primary antibody can also be adjusted according to the dilution of the antibody. Taking the final dilution of antibodies at 1:1000 as an example, take 100 µ Add HRP (mouse) antibody reaction solution into the EP tube and add 10 µ Add the first antibody to 10 ml of antibody diluent, mix well, and incubate at room temperature for 5 minutes. 2) If the membrane area is small, the amount of antibodies, reaction solution, and diluent can be reduced proportionally.5. After completing step 3, pour out the rinsing solution and add the antibody incubation solution mixed with primary antibody, Antibody Pretreat Solution (HRP/Mouse), and Dilution Buffer to the membrane (ensuring that the incubation solution completely submerges the surface of the membrane). Incubate at room temperature on a shaker at around 60 rpm for 40 minutes.6. Discard (recover) the antibody incubation solution and rinse 3-5 times with the prepared 1 x Wash Buffer, each time for 3 minutes. 7. Conduct subsequent testing. It is recommended to use ECL or DAB methods for testing.Application examples:Example 1 Antigen is 293T cell lysateA: Normal WB control: beta actin mouse monoclonal antibody (CW0096) 5 µ Incubate at room temperature for 40 minutes, wash the film and dilute the secondary antibody sheep anti mouse HRP (CW0102) 1:10000. Incubate at room temperature for 40 minutes and expose ECL (CW0049).B: One step method WB: beta actin mouse monoclonal antibody (CW0096) 5 µ Incubate at room temperature for 40 minutes and expose ECL (CW0049).Example 2 Antigen is E. coli multi label protein lysateC: Normal WB control: GST mouse monoclonal antibody (CW0084) 2.5 µ Incubate at room temperature for 40 minutes, wash the film and dilute the secondary antibody sheep anti mouse HRP (CW0102) 1:10000. Incubate at room temperature for 40 minutes and expose ECL (CW0049).D: One step method WB: GST mouse monoclonal antibody (CW0084) was incubated at room temperature with 2.5ug for 40 minutes, and ECL (CW0049) was exposed... Read More |