| Description | Hydrogen peroxide (H₂O₂) is the most common reactive oxygen species (ROS) in living organisms. It is a by-product of active oxygen metabolism, primarily produced by enzymes like SOD and XOD, and degraded by enzymes such as CAT and POD. H₂O₂ is not only a significant ROS but Hydrogen peroxide (H₂O₂) is the most common reactive oxygen species (ROS) in living organisms. It is a by-product of active oxygen metabolism, primarily produced by enzymes like SOD and XOD, and degraded by enzymes such as CAT and POD. H₂O₂ is not only a significant ROS but also a hub for the interconversion of reactive oxygen species. On one hand, H₂O₂ can directly or indirectly oxidize biological macromolecules like nucleic acids and proteins within cells, damaging cell membranes and thereby accelerating cellular aging and disintegration. On the other hand, H₂O₂ is also a key regulatory factor in many oxidative stress responses. It can activate factors like NF-κB, and these H₂O₂-related signaling pathways are associated with many diseases such as asthma, inflammatory arthritis, arteriosclerosis, and neurodegenerative diseases. H₂O₂ is also closely related to processes like cell apoptosis and proliferation.Detection Principle: H₂O₂ oxidizes ferrous ions (Fe²⁺) to ferric ions (Fe³⁺). The Fe³⁺ then forms a purple complex with xylenol orange in a specific solution. The absorbance at 580 nm is directly proportional to the H₂O₂ concentration, allowing for the quantification of H₂O₂ levels.Detection Range: 1-100 µMSensitivity: 1 µMApplicable Samples: Animal/plant tissues, cells, bacteria, serum (plasma), urine.H1492752Component96T480TStorageH1492752AReaction Buffer5 mL25 mL-20℃. Store in the dark.H1492752BH₂O₂ Standard (1M)0.1 mL0.1 mL-20℃. Store in the dark.H1492752CAssay Buffer (10×)13 mL65 mL2-8℃Please check the quantity of each component before the experiment.An additional 10% of each component is provided beyond the specified volume for standard curve preparation or preliminary experiments.User-Provided Instruments and ReagentsTypeNameNotesInstrumentMicroplate ReaderCapable of measuring absorbance at 580 nm.Consumables96-well Microplate / Ultrafiltration tubesStandard transparent plate / 10 kDa MWCOReagentsPBS (pH 7.4) / Deionized Water / 30% ZnSO₄ solutionFor washing cells/bacteria / Reagent preparation / Protein removalOthersHomogenizer (for tissue samples), incubator, ice bucket, low-temperature centrifuge, adjustable pipettes and tipsUsing a multichannel pipette for large-scale detection can improve efficiency.Experimental Procedure1. Reagent PreparationReagent NameReagent PreparationPrecautionsReaction BufferReady-to-use; equilibrate to room temperature before use.Protect from light during the experiment; aliquot and store at -20°C in the dark.H₂O₂ Standard (1M)Ready-to-use; equilibrate to room temperature before use.Protect from light during the experiment; aliquot and store at -20°C in the dark.Assay Buffer (1×)Dilute the 10× Assay Buffer 1:10 with deionized water before use; equilibrate to room temperature.The diluted buffer can be stored at 4°C for at least 2 months. Used for diluting H₂O₂ standard and samples.2. Standard PreparationStandard Curve Setup:First, prepare a 2 mM H₂O₂ Standard: Dilute 2 µL of the 1M H₂O₂ Standard with 998 µL of Assay Buffer (1×).Then, prepare a 100 µM H₂O₂ Standard: Dilute 50 µL of the 2 mM H₂O₂ Standard with 950 µL of Assay Buffer (1×).Using the 100 µM H₂O₂ Standard, prepare further dilutions as shown in the table below.Prepare fresh standard solutions for each experiment.Prepared standards must be used within 4 hours.If the sample is a cell suspension, it is recommended to prepare the H₂O₂ standards using the culture medium.Standard Working Solution100µM Standard (µL)Assay Buffer (1×) (µL)Concentration (µM)1200010021001005034016020420180105101905641962721981Blank020003. Sample PreparationNote: Fresh samples are recommended. If not used immediately, samples can be stored at -80°C for up to 1 month. When ready for the experiment, thaw samples on ice. Note that this may affect sample stability, and results might be lower than expected. The following substances interfere with detection and should be avoided in samples: Ferric salts, iron salts, sucrose, glucose, ascorbic acid, SDS (>0.2%), sodium azide.3.1 Animal Tissues:Wash the tissue with cold PBS to remove as much blood as possible. Blot dry, weigh 0.1 g, and add 1 mL of pre-cooled Assay Buffer (1×). Homogenize the sample on ice. Centrifuge at 10000 g, 4°C for 5 min. Collect the supernatant and keep on ice for detection.3.2 Plant Tissues:Weigh approximately 0.1 g of sample, add 1 mL of pre-cooled Assay Buffer (1×), and grind. Disrupt by ultrasound on ice (power 20% or 200 W, ultrasonicate for 3 s, interval 7 s, repeat 30 times). Centrifuge at 10000 g, 4°C for 5 min. Collect the supernatant and keep on ice for detection.3.3 Cells/Bacteria:Collect 5×10⁶ cells or bacteria. Wash with cold PBS, then add 1 mL of pre-cooled Assay Buffer (1×). Homogenize on ice or disrupt by ultrasound on ice (power 20% or 200 W, ultrasonicate for 3 s, interval 7 s, repeat 30 times). Centrifuge at 10000 g, 4°C for 5 min. Collect the supernatant and keep on ice for detection.3.4 Plasma, Serum, and Urine (and other biological fluids):Remove proteins and use the supernatant. Protein removal methods:Use a 10 kDa ultrafiltration tube: filter and collect the filtrate.Mix sample : 30% ZnSO₄ solution = 20 : 1, vortex, then centrifuge at 10000 g, room temperature for 5 min, and collect the supernatant.4. Assay Steps4.1 Microplate Reader Preparation: Preheat for at least 30 minutes, set wavelength to 580 nm.4.2 Assay System Setup:ReagentStandard Well (µL)Test Well (µL)Standard (various conc.)600Sample060Reaction Buffer40404.3 Mix the reaction system thoroughly and incubate at 37°C for 10 minutes.4.4 Absorbance Measurement: Read the absorbance at 580 nm, recorded as A blank, A standard, and A test. 5. Result CalculationThe following provides both the derived formula and the simplified calculation formula, which are completely equivalent.5.1 Data ProcessingCalculate ΔA standard = A standard - A blank, ΔA test = A test - A blank. 5.2 Standard Curve PlottingPlot the standard curve with standard concentration as the y-axis and ΔA <sub> standard </sub> as the x-axis. Substitute ΔA <sub> test </sub> into the equation to obtain the y value (µM).5.3 Sample H₂O₂ Concentration Calculation(1) Based on sample mass:H₂O₂ Content (nmol/g fresh weight) = y × V sample ÷ (W × V sample ÷ V total ) × n = y ÷ W × n(2) Based on cell or bacterial count:H₂O₂ Content (nmol/10⁴ cells) = y × V sample ÷ (500 × V sample ÷ V total ) × n = y ÷ 500 × n(3) Based on liquid volume:H₂O₂ Content (nmol/mL) = y × V sample ÷ V sample × n = y × nParameter Description:1 µM = 1 nmol/mL;V sample : Volume of sample added;V total : Volume of Assay Buffer (1×) added, 1 mL;n: Sample dilution factor;W: Sample mass, g;500: Cell or bacterial count, in units of 10⁴.6. Result PresentationTypical Standard Curve: y = 207.21x + 1.4921, R² = 0.9988Example-1: 0.1 g of corn tissue was processed and assayed according to the procedure using a 96-well plate.Measured: ΔA test = A test - A blank = 0.278 - 0.048 = 0.230Substituting into the standard curve gives y = 49.15 µM.Calculated based on sample mass:H₂O₂ Content (nmol/g) = y ÷ W × n = 491.5 nmol/g.Precautions1. It is recommended to perform preliminary experiments using 2-3 samples expected to have significant differences before formal testing.2. This kit is compatible with spectrophotometer detection. Adjust the preparation volume of detection reagents proportionally according to the spectrophotometer's requirements.3. It is recommended to establish your own standard curve for improved accuracy. If not, you may refer to the typical standard curve formula provided in the results section for calculation.4. Biochemical reagents are generally irritating and biologically toxic. For your safety and health, please wear appropriate personal protective equipment (lab coat, mask, gloves, hair cap, etc.) throughout the experiment and perform experiments in a fume hood or biosafety cabinet.5. This product is for scientific research use only. Not intended for clinical diagnosis.Frequently Asked QuestionsQ: What should I do if the sample ΔA <sub> test </sub> is too high or too low?A: If the sample ΔA test is greater than the ΔA standard of the 100 µM standard, the H₂O₂ content in the sample is too high. Dilute the sample appropriately with Assay Buffer (1×) (multiply by the dilution factor in the calculation). If the sample ΔA test is less than 0.005, increase the sample amount... Read More | DescriptionThe 200 nm Coupling Kit makes conducting lateral flow tests and biomolecule separation (including cell separation) easier and more flexible. The Kit contains AnteoBind™activated 200 nm magnetic particles that give you increased antibody binding capacity and functionality, while the DescriptionThe 200 nm Coupling Kit makes conducting lateral flow tests and biomolecule separation (including cell separation) easier and more flexible. The Kit contains AnteoBind™activated 200 nm magnetic particles that give you increased antibody binding capacity and functionality, while the included blocking buffer decreases background noise.Reduce reagent preparation time; remove traditional surface preparation steps such as EDC and replace these steps with the 200 nm pre-activated magnetic particles provided. This Kit reduces aggregation and gives you the freedom and ability to produce multifunctional particles for diverse applications, including dual labelling.For lateral flow tests, magnetic particles are easier to handle than gold. Magnetic separation removes the need to perform centrifugation and filtration concentration. Magnetic particles can provide greater sensitivity than gold during lateral flow tests.Binding Capacity and Polydisperity IndexBinding Capacity: > 50 µg IgG/mgPolydispersity Index (PdI)*: < 0.3* The Polydispersity Index (PdI) is dimensionless and determined using Dynamic Light Scattering (DLS). The PdI is scaled such that values smaller than 0.05 are rarely seen and values greater than 0.7 indicate that the sample has a very broad size distribution and poor monodispersity.Particle based Immunoassays, Lateral Flow, Bioseparations and Immunoprecipitation... Read More | D665729 Component 50 T Storage D665729A Conversion Buffer CR 5×1 mL RT D665729B Buffer CL 30 mL RT D665729C Buffer MD 0.4 mL RT D665729D Buffer DB 10 mL RT D665729E Buffer WB (concentrate) 10 mL RT D665729F Buffer GW1 (concentrate) 13 mL RT D665729G Buffer GW2 (concentrate) 15 mL RT D665729H D665729 Component 50 T Storage D665729A Conversion Buffer CR 5×1 mL RT D665729B Buffer CL 30 mL RT D665729C Buffer MD 0.4 mL RT D665729D Buffer DB 10 mL RT D665729E Buffer WB (concentrate) 10 mL RT D665729F Buffer GW1 (concentrate) 13 mL RT D665729G Buffer GW2 (concentrate) 15 mL RT D665729H Buffer EB 4 mL RT D665729I Buffer PS 10 mL RT D665729J Spin Columns DF 50 Pcs 2-8 ℃ D665729K Collection Tubes 50 Pcs RTProduct Introduction:The basic principle of this reagent kit is that after DNA is treated with sodium bisulfite, unmethylated cytosine can be transformed into uracil, while methylated cytosine remains unchanged. And adopting an innovative high-temperature treatment method, the transformation time is greatly shortened, the transformation efficiency is improved, and the transformation efficiency can reach over 99%. At the same time, using a silicon-based membrane purification column, DNA can be recovered and purified from the methylated solution through a simple binding washing elution step. The recovered DNA has high purity and good integrity, and can be directly used for sequencing, methylated PCR detection, chip analysis, connection and transformation, enzyme digestion, labeling, microinjection, PCR and in vitro transcription and other molecular biology experiments.Self prepared reagents: anhydrous ethanol, 75% ethanol.Preparation and important precautions before the experiment1. Product usage method:(1) 10 times packaging preparation method: CT Conversion Agent is a solid mixture that must be prepared before first use. Add 2 ml sterile water and 100 µ M-Dissolving Buffer and 300 µ Add M-Diffusion Buffer to the CT Conversion Agent tube. Dissolve at 55 ° C and shake until completely dissolved. Store the CT Conversion Agent solution at room temperature (20 ° C-30 ° C) in the dark before use. The CT Conversion Agent for each tube is designed for 10 DNA treatments. In order to achieve better results, the prepared CT Conversion Agent should be used immediately. If not used immediately, the CT Conversion Agent solution can be stored at -20 ° C for 1 week. Before use, be sure to thaw the stored CT Conversion Agent solution at room temperature and mix thoroughly by shaking or inverting for 2 minutes, CT Conversion Reagent is sensitive to light, so it is important to minimize exposure to light as much as possible.(2) 50 times packaging preparation method: CT Conversion Agent and M-Dissolving Buffer are solid mixtures that must be prepared before first use. Add 5 ml of sterile water to the M-Dissolving Buffer and shake to dissolve. After all the solids have dissolved, transfer all the solution from the M-Dissolving Buffer tube to the CT Conversion Agent tube and add 5.5 ml of sterile water. Add 1.5 ml of M-Dilution Buffer to the CT Conversion Agent tube. Dissolve at 55 ° C and shake until completely dissolved. Store the CT Conversion Agent solution at room temperature (20 ° C-30 ° C) in the dark before use. The CT Conversion Agent for each tube is designed for 50 DNA treatments. In order to achieve better results, the CT Conversion Agent should be used immediately after preparation. If not immediately used, the CT Conversion Agent solution can be stored at -20 ° C for 1 week. Before use, be sure to thaw the stored CT Conversion Agent solution at room temperature and mix thoroughly by shaking or inverting for 2 minutes, CT Conversion Reagent is sensitive to light, so it is important to minimize exposure to light as much as possible.2. Before the first use, anhydrous ethanol should be added to the M-Wash Buffer according to the instructions on the reagent bottle label.Operation stepsThe range of DNA prepared each time is 1 ng-4 µ Between g, the optimal amount is 500 ng-2 µ G.1. Take 20 µ Add DNA sample into centrifuge tube (self provided), and if the sample amount is insufficient, replenish with water up to 20 µ L.2. Add 2.2 to the DNA sample µ Mix the sample well with the M-Dilution Buffer of l.3.42 ℃ water bath for 30 minutes.4. Add 220 to the sample obtained from the previous step µ Prepare the CT Conversion Agent solution, mix well, and incubate in an 80 ℃ constant temperature water bath in a dark place for 60 minutes.5. Add 480 to the solution in the previous step µ M - Buffer PA, gently mix upside down.6. Column balance: Add 200 to the spin columns DS that have been loaded into the collection tube µ Centrifuge at 12000 rpm (~13400 × g) for 2 minutes, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.7.Add all the solution obtained from step 5 to the adsorption column (already loaded into the collection tube), let it stand at room temperature for 2 minutes, centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.Attention: The maximum capacity of the adsorption column is 750 µ l. If the sample volume is greater than 750 µ L can be added in batches.8. Add 500 to the adsorption column µ Centrifuge at 12000 rpm for 1 minute using M-Buffer PA, discard the waste liquid from the collection tube, and place the adsorption column in the recovery tube.9. Add 650 to the adsorption column µ M-Wash Buffer (please check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column in the collection tube.10.12000 rpm for 2 minutes, discard the waste liquid, and place the adsorption column at room temperature for a few minutes to thoroughly air dry.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which will affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).11. Place the adsorption column into a new centrifuge tube (provided by oneself), and add 20 drops to the middle position of the adsorption membrane in the air µ M-Elution Buffer (pH 8.5), leave at room temperature for 2 minutes. Collect DNA solution by centrifugation at 12000 rpm for 1 minute.12. Collect 20 µ Add 2.2 to DNA µ M-Diffusion Buffer, let it stand at room temperature for 30 minutes.13. Add 500 to the solution µ After pre cooling anhydrous ethanol, invert and mix well, and place the solution at -20 ℃ to precipitate for 30 minutes (overnight precipitation is more effective).14.12000 rpm for 15 minutes and gently discard the supernatant.15. Add 75% ethanol, centrifuge at 12000 rpm for 1 minute, pour out the supernatant, wait for ethanol to evaporate at room temperature, then add 20 µ Dissolve the M-Elution buffer and store the DNA at -20 ℃. The DNA collected in this step can be used for subsequent related experiments... Read More | This product can rapidly, gently, and efficiently lyse mammalian cells, effectively extracting cytoplasmic and nuclear proteins. This reagent uses a mild formula to ensure that the extracted protein maintains biological activity and can be applied to various protein analysis experiments, such as This product can rapidly, gently, and efficiently lyse mammalian cells, effectively extracting cytoplasmic and nuclear proteins. This reagent uses a mild formula to ensure that the extracted protein maintains biological activity and can be applied to various protein analysis experiments, such as reporter gene and enzyme activity determination, immune detection, protein purification, etc. The extracted protein can be quantitatively analyzed using the BCA method. The reagent kit contains a mixture of protease inhibitors, which can effectively prevent protein degradation during the protein extraction process.M665813Component100 TStorageM665813AMammalian Protein Extraction Reagent100 mLRTM665813BProtease Inhibitor Cocktail (100×)1 mL-20℃. Avoid freeze/thaw cycle. precautions1. This product can effectively lyse adherent cells cultured on cell culture plates (without scraping) and suspended cells collected by centrifugation, with higher extraction efficiency than repeated freeze-thaw or ultrasound methods. But for the extraction of tissue proteins, it is recommended to use the tissue protein extraction kit (CW0891).The optimal dosage for protein extraction from adherent cells is listed in Table 1. Collecting cells first can reduce the amount of reagents used to obtain higher protein concentrations.3. The amount of extraction reagents used can also be estimated based on the number of cells. If 2 × 106 Hela cells weigh about 20 mg, 200 need to be added µ Extract reagents.4. The protein extracted from this product can be quantitatively analyzed using the BCA method.Operation steps● Protein extraction from adherent cells1. Please remove the required Mammalian Protein Extraction Agent for pre cooling before protein extraction.2. Carefully pour out the culture medium of adherent cells and rinse the cells with PBS.3. Add an appropriate amount of Mammalian Protein Extraction Reagent (add Protein Inhibitor Cocktail in a 1:99 ratio 2-3 minutes before protein extraction), blow adherent cells on ice with a gun tip, transfer the lysate to a centrifuge tube, incubate on ice for 20 minutes, and allow the cells to fully lyse (please refer to Appendix 1 for the amount of reagent used, and the time for placing on ice should be adjusted according to different cell types). 4. Centrifuge at 14000 × g for 5-10 minutes.5. Transfer the supernatant to a new tube for further analysis. ● Suspension cell protein extraction1. Please remove the required Mammalian Protein Extraction Agent for pre cooling before protein extraction.2. Suspend 2500 × g of cells, centrifuge for 10 minutes, and discard the supernatant. Rinse cells with PBS. 2500 × g, centrifuge for 10 minutes, discard the supernatant.3. Add an appropriate amount of Mammalian Protein Extraction Agent, and 2-3 minutes before protein extraction, add Protein Inhibitor Cocktail in a ratio of 1:99, which is 1 x working solution.4. Add at least 1 ml of 1x working solution to every 100 mg of cells. If the extracted sample size is large, a small amount of 1x working solution can be used to resuspend the cells first, and then the remaining working solution can be added.5. After blowing evenly, place it on ice for 20 minutes to allow the cells to fully lyse (the time for placing it on ice should be adjusted according to different cell types). 6. Centrifuge at 14000 × g for 15 minutes.7. Transfer the supernatant to a new tube for further analysis.Table 1. Recommended usage of extraction reagents Cell culture plate type or dish type Extraction reagent usage 100 mm 500-1,000 µl 60 mm 250-500 µl 6-well culture plate 200-400 µl /well 24-well culture plate 100-200 µl /well 96-well culture plate 50-100 µl /well Table 2. Common Problems and Solutions Problem Possible reasons Resolvent Low extraction rate Low protein expression level Optimize transfection system Low extraction rate Insufficient reagent usage Increase the usage of extraction reagents Low extraction rate Reagent unable to dissolve cell membrane Increase cracking time or increase shaking amplitude Unable to obtain membrane protein This product is more suitable for extracting nuclear plasma protein Using eukaryotic cell membrane protein extraction kit... Read More | Product contentcomponent50T200TBuffer LP125mL100mLBuffer LP210mL40mLBuffer LP3 (concentrate)21ml84mlBuffer GW2 (concentrate)15mL75mlBuffer GE15mL60mLRNase A(10 mg/ml)300µl1.25mLSpin Columns DM with Collection Tubes50200ProductsThis kit uses centrifugal adsorption columns with highProduct contentcomponent50T200TBuffer LP125mL100mLBuffer LP210mL40mLBuffer LP3 (concentrate)21ml84mlBuffer GW2 (concentrate)15mL75mlBuffer GE15mL60mLRNase A(10 mg/ml)300µl1.25mLSpin Columns DM with Collection Tubes50200ProductsThis kit uses centrifugal adsorption columns with high efficiency and specific binding of nucleic acids and a unique buffer system, which is suitable for extracting genomic DNA from a wide variety of different fresh or frozen plant tissues with maximum removal of impurities from the plant tissues. The kit eliminates the need for phenol/chloroform extraction and is safe to handle. The extracted genomic DNA fragments are large, high purity, stable and reliable quality, suitable for PCR, fluorescence quantitative PCR, molecular labeling, library construction and other experiments.Self-contained reagent: anhydrous ethanolPre-experiment Preparation and Important Notes1. Repeated freezing and thawing of the sample should be avoided, as this may result in smaller fragments of extracted DNA and a decrease in the amount extracted.2. Anhydrous ethanol should be added to Buffer LP3 and Buffer GW2 according to the instructions on the label of the reagent bottle before first use. Check Buffer LP1 and Buffer LP2 for crystallization or precipitation before use. If crystallization or precipitation occurs, re-dissolve Buffer LP1 and Buffer LP2 in a 56°C water bath. Procedure1. Take about 100mg of fresh plant tissue or about 20mg of dry weight tissue and add liquid nitrogen to grind it fully.2. Collect the ground powder into a centrifuge tube (self-provided), add 400 µl Buffer LP1 and 6 µl RNase A (10 mg/ml), vortex and oscillate for 1 minute, and leave it at room temperature for 10 minutes to allow for full cleavage.Note: 1) Use vortex shaking or pipette blowing to fully lyses the tissue, incomplete tissue lysis will affect the final DNA yield. 2) Do not mix Buffer LP1 with RNase A prior to use.3. Add 130 µl Buffer LP2, mix well and vortex for 1 minute.4. Centrifuge at 12,000 rpm (~13,400 x g) for 5 minutes and transfer the supernatant to a new centrifuge tube (supplied).5. Add 1.5 times the volume of Buffer LP3 (check that anhydrous ethanol has been added before use) and mix thoroughly (e.g., 500 µl filtrate to 750 µl Buffer LP3).Note: Buffer LP3 should be mixed immediately after addition; precipitation may occur but will not affect subsequent experiments.6. Add all of the solution and precipitate obtained in the previous step to the adsorption columns (Spin Columns DM) that have been loaded into the collection tubes, if the solution cannot be added all at once, it can be transferred in several times. centrifuge the columns at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tubes, and put the columns back into the collection tubes.7. Add 500 µl of Buffer GW2 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorption column back into the collection tube.Note: If the adsorbent membrane appears green, add 500 µl of anhydrous ethanol to the adsorbent column, centrifuge the column at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorbent column back into the collection tube.8. Repeat step 7.9. Centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Leave the adsorption column at room temperature for several minutes to dry thoroughly.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can interfere with subsequent enzymatic reactions (digestion, PCR, etc.).10. Place the adsorption column in a new centrifuge tube (supplied), add 50-100 µl of Buffer GE or sterilized water dropwise to the middle of the adsorbent membrane, leave it at room temperature for 2-5 minutes, and centrifuge it at 12,000 rpm for 1 minute to collect the DNA solution. -The DNA solution was collected by centrifugation at 12,000 rpm for 1 min.Note: 1) If the downstream experiment is sensitive to pH or EDTA, you can use sterilized water for elution. The pH value of the eluent has a great influence on the elution efficiency, if you use water as the eluent, you should ensure that the pH value is 7.0-8.5 (you can use NaOH to adjust the pH value of the water to this range), and when the pH value is lower than 7.0, the elution efficiency is not high.2) Incubation at room temperature for 5 minutes prior to centrifugation increases yield.(3) If the final concentration of DNA is to be increased, the DNA eluate obtained in step 10 can be re-added to the adsorbent membrane and repeat step 10; if the elution volume is less than 100µl, the final concentration of DNA can be increased, but it may reduce the total DNA yield. If the amount of DNA obtained is less than 1µg, 50µl Buffer GE is recommended for elution.4) Because DNA stored in water is subject to acidic hydrolysis, for long-term storage, elution with Buffer GE and storage at -20°C are recommended... Read More |