| Description | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export | Product introduction:Used to isolate lymphocytes from human organsMatters needing attention:1. samples, reagents and experimental environment in the whole process shall be carried out at 20 ± 2 ℃. In order to obtain the best experimental results, it is best to carry out the Product introduction:Used to isolate lymphocytes from human organsMatters needing attention:1. samples, reagents and experimental environment in the whole process shall be carried out at 20 ± 2 ℃. In order to obtain the best experimental results, it is best to carry out the experiment within 2 h of sampling. The longer the sample is stored, the worse the cell separation effect is. The separation effect is even worse after the sample is placed for more than 6 h, or even cannot achieve the purpose of separation. 2. in this experiment, it is better not to use plastic products with high polymerization materials (such as polystyrene), but use non-static, low static ionization heart tubes and glass products without alkali treatment, because the electrostatic effect will lead to cell adhesion, and the surface of alkali treated glass will become rough, which will affect the effect of cell separation. 3. aspirating too many lymphocyte layers and separation liquid layers will cause the granulocytes at the junction of separation liquid to be aspirated, thus increasing the number of mixed granulocytes. 4. when the amount of separating solution is greater than that of tissue single cell suspension sample, the separation effect is better.Scope of application:Lymphocyte isolation... Read More | N665925 Component 1 mL 5 mL Storage N665925A 2×SYBR qPCR Master Mix 1 1 mL 5 mL -20℃. Avoid freeze/ Thaw cycle. N665925B qPCR Primer Mix 1 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665925C DNA Standard I 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665925 Component 1 mL 5 mL Storage N665925A 2×SYBR qPCR Master Mix 1 1 mL 5 mL -20℃. Avoid freeze/ Thaw cycle. N665925B qPCR Primer Mix 1 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665925C DNA Standard I 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665925D DNA Standard II 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665925E DNA Standard III 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665925F DNA Standard IV 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665925G DNA Standard V 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665925H 50×High ROX 40 µL 200 µL -20℃. Avoid freeze/ Thaw cycle.Product IntroductionThis product is a real-time fluorescence quantitative PCR of the products after NGS library construction using a dye method (SYBR Green I).(qPCR). The kit provides the reaction mixes, DNA primer mixtures, standards and sample dilutions required for the qPCR process, making the reagent system complete and easy to use. The fluorescent dye SYBR Green I contained in the reaction mixture can bind to all double-stranded DNA; the GoldStar Taq DNA Polymerase used is a chemically modified new high-efficiency hot-start polymerase, and the activation of the enzyme needs to be incubated at 95℃ for 10 minutes. the product has high specificity, high amplification efficiency, and is able to quickly and accurately quantify the concentration of the constructed libraries. The product is highly specific and efficient in amplification, and can quickly and accurately quantify the concentration of the constructed library.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used in Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument.Instruments that do not require ROX calibration: Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96, etc.Instruments requiring Low ROX calibration: ABI Prism7500/7500 Fast, QuantStudio®3 System, QuantStudio®5 System, QuantStudio®6 Flex System, QuantStudio®7 Flex System, ViiA 7 System, Stratagene Mx3000/Mx3005P, Corbett Rotor Gene 3000, and others.Instruments requiring High ROX calibration: ABI Prism7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, etc.Note: High Rox and Low Rox are formulated as described in Use 2.Scope of applicationThis product is designed for absolute quantification of the concentration of Ion torrent platform second generation sequencing libraries. The end of the library contains Ion torrent P5 and P7 microarray binding sequences, the length of which does not exceed 1kb, and the concentration is not less than 0.005pM can be used to perform quantitative experiments with this product. The qPCR Primer Mix provided in the kit contains the following two primer sequences:Primer 1:5'-CCA TCT CAT CCC TGC GTG TC - 3' Primer 2: 5'-CCT CTC TAT GGG CAG TCG GTG AT-3'The primer sequence can be used in advance to confirm whether the library can be amplified by that primer pair.Usage1. Amplification template preparationThe library samples to be detected were diluted with TE (10 mM Tris-Cl, pH 8.0, 1 mM EDTA), and the concentration after dilution was as close as possible to the range of 0.05-50 pM. 4°C on ice was set aside.2. qPCR reaction system preparationThe desired cryopreservation reagent is pre-melted completely and mixed by inverting several times before preparation, then centrifuged briefly and set aside.The base reaction system for 20 µl was as follows:Reagent20 µl Reaction system2×SYBR qPCR MasterMix10 µlqPCR Primer Mix 10.8 µlTemplate4 µlddH₂O5.2 µlDescription: High Rox model: add 1 µl High Rox per 50 µl of reaction system;Low Rox model: 1 µl High Rox per 500 µl of reaction system.Prepare a sufficient amount of reaction system mixture according to the need, mix well and add to the reaction wells in a volume of 16 µl per well, add the same volume of TE to the blank control, and then add the prepared standards and diluted samples to the corresponding reaction wells in a volume of 4 µl/well. It is recommended to use 20 µl reaction system, if you need to carry out a smaller system reaction, the system components can be reduced in equal proportion.3. qPCR reaction program1) Please use 60-64℃ as a reference for setting range of annealing temperature, and increase the annealing temperature when non-specific reaction occurs.2) If the average length of the library is greater than 700bp, the annealing/extension time should be increased appropriately.data analysis1. Standard curve productionThe standard curve was plotted using Ct values in the valid range. The standard curve correlation coefficient R2 should not be less than 0.99 and the slope should lie between -3.1 and -3.6. If the standard curve parameters are not reasonable, it is recommended to repeat the experiment.DNA Standard NameDNA Standard ConcentrationDNA Standard I50 pMDNA Standard II5 pMDNA Standard III0.5 pMDNA Standard IV0.05 pMDNA Standard V0.005 pM2. Library concentration calculationThe difference in Ct between the three replicate wells of the experiment should be no more than 0.2, otherwise the invalid data should be deleted or the experiment should be repeated. Do not use the Ct outside the valid Ct range of the standard curve to calculate the concentration of the diluted libraries. Please refer to the data processing Excel of this product for the specific library concentration calculation method.matters needing attention1. Before testing, these instructions should be read in detail. It should be operated by personnel with professional experience or qualified by training.2. For use, please mix gently by turning up and down, avoid foaming as much as possible, and use it after centrifugation for a short period of time.3. Avoid repeated freezing and thawing of the product, repeated freezing and thawing may degrade the performance of the product.4. When preparing the reaction solution, please use new or non-contaminated tips and centrifuge tubes to prevent contamination as much as possible... Read More | Product introduction:Reporter gene detection is an important tool for analyzing the interaction between potential cis elements (such as promoters, enhancers and silencers) and trans acting factors in the flanking region of structural genes in the field of modern molecular biology. Firefly Product introduction:Reporter gene detection is an important tool for analyzing the interaction between potential cis elements (such as promoters, enhancers and silencers) and trans acting factors in the flanking region of structural genes in the field of modern molecular biology. Firefly luciferase is widely used in gene regulation and drug screening. Firefly luciferase is a protein with a molecular weight of about 61 KD. In the presence of ATP, magnesium ions and oxygen, it can catalyze the production of oxyluciferin from luciferin. In the process of luciferin oxidation, it will produce a light signal. The optical signal of this kit is a kind of instantaneous light, which needs to be detected immediately after adding the working solution. The half-life of optical signal is about 5 min.Instruction:1.Working fluid configuration ( 1 ) Restore all components to room temperature. ( 2 ) The component B ( stock solution ) was fully diluted with component A to prepare a 0.2 mg / mL firefly luciferase working solution, which was vortexed and shaken to ensure full mixing. Note : The firefly luciferase working solution cannot be repeatedly frozen and thawed. If the dosage of a single experiment is small, it is recommended to subpackage according to a single dosage. At room temperature, the activity decreased by about 10 % after the working solution was configured for 3 h, and the activity decreased by about 25 % after 5 h. 2.chemiluminescence value detection ( 1 ) The cell culture plate was taken out from the incubator and incubated at room temperature for 20 min to restore it to room temperature ( 22-25 ° C ). ( 2 ) Add the same volume of firefly luciferase working solution with the medium to the culture plate and mix well. ( 3 ) Incubation at room temperature for 5 min. Note : The incubation time can be adjusted according to cell type and cell number. ( 4 ) The values were read by multifunctional microplate reader or chemiluminescence instrument ( instrument parameters : the determination time was 10 s, the determination interval was 2 s ).Matters needing attention:1. please centrifuge the product to the bottom of the tube immediately before use, and then conduct subsequent experiments. 2. the strongest wavelength of bioluminescence catalyzed by firefly luciferase is 560 nm. 3. to prevent interference between holes, it is recommended to use white opaque orifice plate.Recommendation:Component B is recommended to use sterile water in advance to configure 2 mg / mL storage solution, A component and B component configured as storage solution, and small batch packaging according to the experimental requirements. The detection working fluid is recommended to be used now to avoid repeated freezing and thawing. Component:One-Step Firefly Luciferase Assay Buffer;D-Luciferin Scope of application:Mainly used for ADCC detection... Read More | DescriptionPhoto KitAlysis Starter Kit enables screening of 24 micro-scale simultaneous photocatalytic reactions with consistent and reproducible photon intensity. User guide is provided in the below hyperlink.Photo KitAlysis Operating InstructionsComponents:Photo KitAlysis LED ControllerBlue LED DescriptionPhoto KitAlysis Starter Kit enables screening of 24 micro-scale simultaneous photocatalytic reactions with consistent and reproducible photon intensity. User guide is provided in the below hyperlink.Photo KitAlysis Operating InstructionsComponents:Photo KitAlysis LED ControllerBlue LED Array (470 nm)Photo KitAlysis Reaction BlockTorque screwdriverSmall screwdriver to easily remove torqued screws after reaction is completeFeatures:Designed and tested by synthetic chemists.Controller provides repeatable milliamp selection for photon intensity0-30 mA variable LED output3 different LED options: blue (470 nm, included), green (527 nm, sold separately), and white (sold separately)Non-magnetic LED baseChemically resistant LED coverPTFE coated cablingDesigned to be used withPhoto KitAlysis High-Throughput Reaction Screening Kit(sold separately).Best when used withKitAlysis Benchtop Inertion Box(sold separately)... Read More |