| Description | Inquire | Product IntroductionAlamar Blue detection reagent provides a simple, rapid, reliable and safe method for cell proliferation and cytotoxicity detection, which is suitable for high-throughput detection experiments. The main component of the detection reagent is a redox indicator. In the oxidized stateProduct IntroductionAlamar Blue detection reagent provides a simple, rapid, reliable and safe method for cell proliferation and cytotoxicity detection, which is suitable for high-throughput detection experiments. The main component of the detection reagent is a redox indicator. In the oxidized state, it appears purple-blue and non-fluorescent, while in the reduced state, it turns into a reduction product with pink or red fluorescence, with an absorption peak of 530-560nm and an emission peak of 590nm.In the process of cell proliferation, the ratios of NADPH/NADP, FADH/FAD, FMNH/FMN and NADH/NAD in the cell increase and are in a reducing environment. The dye taken into the cell is reduced by these metabolic intermediates and cytochromes and then released outside the cell and dissolved in the culture medium, changing the culture medium from non-fluorescent indigo blue to fluorescent pink. Finally, use an ordinary spectrophotometer or fluorophotometer for detection, and the absorbance and fluorescence intensity are proportional to the number of active cells.Instructions1. Add 10µl of detection reagent to 100µl of cell suspension, and incubate in a cell incubator for 2-6 hours. The color of the medium changes from indigo blue to pink and you can proceed to the next step.2. It is recommended to use a fluorescence microplate reader for detection, the excitation light wavelength is between 530-560 nm, the emission light wavelength is 590 nm, and the relative fluorescence unit (RFU) is recorded.3. Draw a standard curve or cell growth curve: the ordinate (Y axis) is the relative fluorescence unit (RFU); the abscissa (X axis) is the cell number or time point or drug concentration.Precautions1. The appropriate density of cells can increase the detection sensitivity. For 96-well plates, we recommend seeding 100 microliters of cells per well. The cell concentration range is: 100-10,000/well for adherent cells, 2,000-50,000/well for suspension cells, and medium as a blank control. For 384-well plates, the cell concentration and seeding volume are both halved.2. The whole process should be aseptic operation, because microbial contaminants can also reduce the detection reagents and affect the experimental results.3. Pay attention to the concentration of inoculated cells and the incubation time after adding detection reagents. If the cell concentration is too high or the incubation time is too long, it will cause a secondary reduction reaction, resulting in colorlessness and disappearance of fluorescence.4. When incubating, avoid light.5. This product can use fluorescence or spectrophotometric detection, but the sensitivity of fluorescence is high, and the experimental error is small. Fluorescence detection is recommended... Read More | Products contentN665730Component24 T96 TStorageN665730ATPS V50 144 µL576 µL-20℃. Avoid freeze/thaw cycle.N665730B5×FA Reaction Buffer144 µL576 µL-20℃. Avoid freeze/thaw cycle.N665730C2×HiFidelity PCR Mix600 µL2×1.2 mL-20℃. Avoid freeze/thaw Products contentN665730Component24 T96 TStorageN665730ATPS V50 144 µL576 µL-20℃. Avoid freeze/thaw cycle.N665730B5×FA Reaction Buffer144 µL576 µL-20℃. Avoid freeze/thaw cycle.N665730C2×HiFidelity PCR Mix600 µL2×1.2 mL-20℃. Avoid freeze/thaw cycle.N665730DPPM48 µL192 µL-20℃. Avoid freeze/thaw cycle.* This kit is suitable for human genomic DNA library construction with a starting template DNA input of 50 ng. We also have transposase library construction kits for human genomic DNA starting at 5 ng and 1 ng, so it is recommended to use different kits for different starting amounts of DNA in order to obtain higher quality libraries. Products IntroductionThis kit is developed for Illumina's high-throughput sequencing platform and provides the enzyme premix system and reaction buffer for genomic DNA library construction, including all components except PCR primers. Compared with the traditional library construction kits, this kit adopts the new transposase method for library construction, which can complete DNA fragmentation, end repair and junction reaction in one simple enzymatic reaction, significantly reducing the amount of template, reducing the number of experimental steps, and shortening the time of library construction; it adopts the high-fidelity DNA polymerase for library enrichment, and the preference-free PCR amplification can expand the coverage area of the sequence, which can be used for efficient and effective sequencing. The use of high-fidelity DNA polymerase for library enrichment and preference-free PCR amplification broadens the coverage area of the sequence and enables efficient preparation of DNA libraries for Illumina's second-generation sequencing platform. The kit is suitable for DNA libraries with a starting template of 50 ng, and all reagents in the kit have been subjected to strict quality control and functional validation to maximize the stability and reproducibility of library construction. Product Features ● DNA fragmentation and junction ligation in one step.● Ultra-fidelity amplification minimizes amplification-preferred steps.Provide your own instruments, kits and consumables1. Magnetic frame: DynaMagTM-2 is recommended.2. DNA purification and recovery kit: It is recommended to use DNA purification and recovery kit by magnetic bead method.3. Library PCR primer kits: transposase method for second-generation sequencing multi-sample primer kits are recommended. 4. Anhydrous ethanol, deionized water (pH between 7.0 and 8.0).5. Reaction tubes: It is recommended to use low adsorption PCR tubes and 1.5 ml centrifuge tubes. Tips: It is recommended to use high quality filter tips to prevent contamination of kits and library samples. Pre-experiment Preparation and Important Notes1. Avoid repeated freezing and thawing of reagents.2. PCR products are easily contaminated due to improper operation, resulting in inaccurate results. It is recommended to isolate the PCR reaction system preparation area from the PCR product purification area, and to use special pipettes to clean the experimental areas at regular intervals.3. Bead purification: the beads should be equilibrated to room temperature before use, all operations on the beads should be carried out at room temperature, 80% ethanol should be dispensed freshly, the beads should be rinsed and dried until the surface is free of liquid reflections and has a frosted appearance, insufficient drying of the beads will cause ethanol residue that will affect the subsequent experiments, and over-drying of the beads will affect the efficiency of DNA recovery.4. The kit is suitable for human genomic DNA library construction, if the DNA sample is a PCR product, it should be ensured that its length>.500 bp, since transposases do not work on DNA ends, it is recommended to extend the PCR product by 50-100 bp at each end of the PCR product to avoid low coverage of the ends for sequencing.Sample PreparationDNA purity requirements: A260/A280 = 1.8-2.0. Sample DNA: dissolve in ultrapure water. DNA Quantification: Too much or too little DNA will affect the quality of the library. It is recommended to use Nano to test the purity of the genomic DNA and then use Qubit to test the concentration of the genome (do not use any absorbance-based assay for template quantification).Schematic diagram of DNA banking processprocedureDNA fragmentation, junction reaction1. Add the following reagents to a 200 µl PCR tube: 2. Mix by gently blowing with a pipette and centrifuge briefly so that all components are collected at the bottom of the tube.3. Place the above PCR tubes in the PCR instrument with the hot cap on and program the reaction as follows:DNA should be purified immediately after the fragmentation reaction has been performed and the transposase is still in a high state of activity.to prevent smaller library fragments due to DNA over-fragmentation. Purification of fragmentation productsWe recommend the use of the Century Magnetic Bead Method DNA Purification and Recovery Kit.1. CMPure should be equilibrated at room temperature for 30 min after shaking and mixing before use.2. Add 50 µl of magnetic beads equilibrated to room temperature to the fragmentation product, vortex and shake for 5 seconds, then let stand at room temperature for 5 minutes.3. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant solution until the solution is clear (approximately 3-5 minutes), carefully aspirate the supernatant and discard, avoiding contact with the beads that have bound the target DNA. Note: Do not discard the beads.4. Continue to keep the centrifuge tube fixed on a magnetic rack and add 200 µl of freshly prepared 80% ethanol to the centrifuge tube and allow to stand at room temperature for 30 seconds, carefully discarding the supernatant.Note: When adding ethanol, the liquid must not be blown directly onto the beads.5. Repeat step 4.6. Keep the centrifuge tube fixed on a magnetic rack and leave to dry at room temperature until the surface of the beads is slightly cracked, then add 23 µlddH2O to solubilize.Note: Do not over-dry the beads as this may affect the elution efficiency.7. Remove the tube from the magnetic rack, vortex to completely resuspend the beads, and allow to stand at room temperature for 5 minutes. Centrifuge briefly, place the tube on the magnetic rack until the solution is clear, and transfer 21 µl of supernatant to a new 200 µl PCR tube.PCR amplification Add the following reagents to the 200 µl PCR tube: Mix by gently blowing with a pipette and centrifuge briefly so that all components are collected at the bottom of the tube.3. Place the above PCR tubes in the PCR instrument with the hot cap on and program the reaction as follows:Selective recovery of library DNA fragmentsIt is recommended to use CombiVision Magnetic Beads DNA Purification and Recovery Kit for selective recovery of DNA fragments. When different sizes of DNA fragments are required, the amount of magnetic beads to be used is different, please refer to the attached table for the specific amount of magnetic beads to be used (if other brands of magnetic beads are used, you need to find out the optimal amount of magnetic beads to be used on your own).Note: Amplification products can also be fragment length sorted and purified using the Gum Recovery Kit. If there is no special requirement for library length distribution, the amplification products can also be purified without selective recovery of DNA fragments as described on page 6 of the manual.1. CMPure should be equilibrated at room temperature for 30 min after shaking and mixing before use.2. Transfer the PCR product to a 1.5 ml centrifuge tube, rehydrate to 100 µl and add several volumes of magnetic beads equilibrated to room temperature, vortex for 5 seconds and let stand at room temperature for 5 minutes.3. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant until the solution is clear, and carefully aspirate the supernatant and transfer it to a new 1.5 ml centrifuge tube.Note: Do not discard the top clear.4. Add several volumes of magnetic beads to the supernatant, vortex and shake for 5 seconds, then let stand at room temperature for 5 minutes.5. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant until the solution is clear, carefully aspirate the supernatant and discard it, avoiding contact with the beads that have bound the target DNA.Note: Do not discard the beads.6. Continue to keep the centrifuge tube fixed on a magnetic rack and add 200 µl of freshly prepared 80% ethanol to the tube and allow to stand at room temperature for 30 seconds, carefully discarding the supernatant.Note: When adding ethanol, the liquid must not be blown directly onto the beads.7. Repeat step 6 once.8. Keep the centrifuge tube fixed on a magnetic rack and leave to dry at room temperature until the surface of the beads is slightly cracked, add 20 µl of ddH2O to solubilize.Note: Do not over-dry the beads as this may affect the elution efficiency.9. Remove the centrifuge tube from the magnetic rack, vortex and oscillate to completely resuspend the beads, and let stand at room temperature for 5 minutes. Leave brieflycentrifuge, place the tube on a magnetic rack until the solution is clear, and transfer the supernatant solution to a new centrifuge tube. Table: Suggested amount of magnetic beads for different segment selection recoveryLibrary DNA fragment purificationWe recommend the use of the Century Magnetic Bead Method DNA Purification and Recovery Kit.1. CMPure should be equilibrated at room temperature for 30 min after shaking and mixing before use.2. 50 µl of magnetic beads equilibrated to room temperature were added to the PCR product, vortexed and shaken for 5 seconds, and then left to stand at room temperature for 5 minutes.3. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant solution until the solution is clear (approximately 3-5 minutes), carefully aspirate the supernatant and discard it, avoiding contact with the beads that have bound the target DNA. Note: Do not discard the beads.4. Continue to keep the centrifuge tube fixed on a magnetic rack and add 200 µl of freshly prepared 80% ethanol to the centrifuge tube and allow to stand at room temperature for 30 seconds, carefully discarding the supernatant.Note: When adding ethanol, the liquid must not be blown directly onto the beads.5. Repeat step 4.6. Keep the centrifuge tube fixed on a magnetic rack and leave to dry at room temperature until the surface of the beads is slightly cracked, add 25 µl of ddH2O to solubilize.Note: Do not over-dry the beads as this may affect the elution efficiency.7. Remove the tube from the magnetic rack, vortex to completely resuspend the beads, and allow to stand at room temperature for 5 minutes. Centrifuge briefly, place the tube on the magnetic rack until the solution is clear, and transfer the supernatant solution to a new tube.Library quality controlDetermination of library concentrationIn order to obtain high-quality sequencing results, accurate quantification of DNA libraries is required, and the first recommendation is to use Real-timePCR methods are used for absolute quantification of DNA libraries. Additionally, fluorescent dye methods such as the Qubit method or the fluorescent dye picogreen method can be used; do not use quantification methods based on absorbance measurements here. The following approximate formula can be used to convert the molar concentration of the DNA library. Average total length of librariesApproximate conversion formula Library fragment distributionThe prepared DNA libraries can be detected by agarose gel electrophoresis or Agilent 2100 Bioanalyzer.Range of segment length distributions... Read More | The fluorescent dye PKH67 is suitable for conventional cell membrane labeling. It is a green fluorescent dye that can track cells in vitro and in vivo. It labels cells by binding to the lipid components of the membrane structure. PKH67 has low cytotoxicity, low fluorescence background, high fat The fluorescent dye PKH67 is suitable for conventional cell membrane labeling. It is a green fluorescent dye that can track cells in vitro and in vivo. It labels cells by binding to the lipid components of the membrane structure. PKH67 has low cytotoxicity, low fluorescence background, high fat solubility, can easily penetrate cell membranes, and has strong and stable green fluorescence. PKH67-labeled cells can be used for in vitro and in vivo proliferation studies, and have the function of not staining neighboring cells. In the process of cell division and proliferation, the fluorescence intensity of PKH67 will gradually decrease as the cells divide. The labeled fluorescence can be evenly distributed to the two sub-generation cells, so its fluorescence intensity is half that of the parent cell. According to this feature, It can be used to detect cell proliferation, cell cycle estimation and cell division, etc. The fluorescence of PKH67-labeled cells is very uniform, and the fluorescence distribution of sub-generation cells after division is also more uniform. In the process of cell division and proliferation, PKH67-labeled fluorescence can be evenly distributed between the two sub-generation cells, and the fluorescence intensity becomes half of that of the parent cell. According to the difference in fluorescence intensity, the undivided cells can be detected by flow cytometry. One time (1/2 the fluorescence intensity), the second time (1/4 the fluorescence intensity), three times (1/8 the fluorescence intensity), and more divisions of cells. PKH67 can detect splits up to six times or even more. In addition to the detection of cell proliferation, PKH67 can also be used for in vitro tracking of cells. After labeling, the fluorescence expression is stable in the cell, and the positive labeling rate is over 98%. The labeled cells have good morphology, which can effectively observe the cells in vitro. Induce differentiation; or inject labeled cells into the body, it can effectively show the migration and differentiation of transplanted cells in living tissues. PKH67-labeled cells can be used for in vivo observation for as long as several weeks. It is often used for in vivo cell detection experiments and experiments to observe long-term cell activity using fluorescence electron microscope. PKH67 is less toxic and does not affect cell proliferation. This method is simple to operate, does not use radioactive isotopes, and poses no safety hazards. You can get the desired experimental data faster, more accurately and more safely.Due to the longer length of the charcoal tail, internal studies have shown that PKH67 is less transferred between cells than PKH2. In in vivo studies using PKH1 and PKH2, the fluorescence intensity will slowly lose. Since this is a behavioral characteristic of green cell linker dye rather than red cell linker dye, PKH67 will have similar properties. The correlation between the in vitro cell membrane retention of non-dividing cells and the in vivo fluorescence half-life reveals that the in vivo fluorescence half-life of PKH67 is 10-12 days. Other green cell linker dyes with similar half-lives have been used to monitor the transport of lymphocytes and macrophages in the body within one to two months. The results indicate that PKH67 can also be used for medium-term in vivo tracking studies.The dye can stably bind to the lipid region of the cell membrane and emit fluorescence, and is mainly used for cell labeling in vitro, cell proliferation research in vitro, and cell tracing research in vivo and in vitro. The fluorescence half-life of PKH67 in vivo is 10-12 days. Compared with PKH-67, PKH-26 has a longer half-life, and the half-life of PKH26 labeled on rabbit red blood cells is more than 100 days. Especially suitable for in vitro proliferation research and long-term in vivo cell tracking research. After PKH67 labels the cells, flow cytometry is usually used for cell proliferation detection.Kit components0.1ml kits: P266290A-0.1ml P266290B-10ml1ml kits: P266290A-1ml P266290B-60mlDyes with A suffix and diluents with B suffix are used togetherPKH67 labeled cells show green fluorescence, the fluorescence wavelength: λex=490 nm, λem=502 nm.Storage conditions: -20℃ protected from light, valid for 1 yearPrecautions●Staining concentration varies according to the type of cell and the number of cells in each well.● The prepared PKH67 mother liquor is very easy to dissolve. It is recommended to store in aliquots and freeze-dry at ≦-20℃.● PKH67 working solution should be prepared for immediate use, and cannot be prepared in advance, because PKH67 will decompose due to the absorption of water and affect the dyeing effect.● PKH67 is easily decomposed and will deteriorate quickly in the water solution. Please avoid contact with water during use of mother liquor. The working fluid is in contact with the water during the process of labeling the cells within the permitted time range.● PKH67 fluorescent dye is a DMSO solution. It will solidify and stick to the bottom, wall or cap of the tube at a lower temperature such as 4℃ and ice bath. After being taken out of the refrigerator, it will return to room temperature and become After the liquid is in the state, remove the cap from the bottom of the tube. It can be used after it has completely melted in a 37°C water bath.● The number of generations or time that can be traced after different cell types are marked is quite different. Please make a test based on the actual situation or reference documents.Instructions1. Staining solution preparation:(1) Take out the PKH67 reagent from the refrigerator, let it stand for a few minutes to room temperature, or after a 37°C water bath, leave the tube containing PKH67, and be sure to leave the tube for a few minutes before opening the lid to allow the reagent to fully fall into the tube The lid can only be opened after the bottom.(2) According to the number of cell samples to be tested, dilute the probe 10 times with the diluent, and then use a suitable solution (such as non-clear medium, HBSS or PBS) to dilute the PKH67 mother liquor 25 times to prepare a stain Work fluid. The best working solution concentration should be adjusted according to different cells and your own experimental system. Generally, the cells can be diluted 250 times according to the final concentration of the mother liquor in the kit. Some cells may need to increase the concentration appropriately.2. Cell staining(1) Resuspend the prepared cells to be tested in 100µl of staining solution to a cell concentration of about 107/ml. You can also perform in-situ staining, as long as the staining solution is enough to cover the cells.(2) Culture the cells at 2~8℃ for 15~30 minutes. The best culture time is different for different cells.It is recommended to incubate the labeled cells in the staining solution at 37°C for 5 minutes, and then at 4°C for 15 minutes.Low-temperature incubation can reduce the endocytosis of the dye by the cells, help the dye to label the plasma membrane, and reduce the possibility of the dye localizing to cytoplasmic vesicles.(3) After separation, remove the supernatant, collect the cells, wash the cells 1-2 times with PBS or non-clear medium, and finally add PBS or non-clear medium to resuspend the cells.(4) Take 500µl of cell suspension and test with flow cytometer. Ex/Em=490/502nm.(5) Subsequently, the cells can be cultured according to the normal culture method.(6) The labeling effect can be directly observed under a fluorescence microscope, or the cell proliferation can be detected by a flow cytometer after an appropriate period of culture, or used for cell fluorescence traces for other specific experimental purposes... Read More | Inquire |