| Description | Inquire | Product content: Component G665666 200 preps Buffer P1 60ml Buffer P2 60ml Buffer E3 60ml Buffer PW (concentrate) 25ml Buffer EB 30ml RNase A (10 mg/ml) 600 µl Spin Columns DM 200 with Collection Tubes 200Product Introduction:This reagent kit is suitable for extracting 1-5 ml of Product content: Component G665666 200 preps Buffer P1 60ml Buffer P2 60ml Buffer E3 60ml Buffer PW (concentrate) 25ml Buffer EB 30ml RNase A (10 mg/ml) 600 µl Spin Columns DM 200 with Collection Tubes 200Product Introduction:This reagent kit is suitable for extracting 1-5 ml of bacterial solution. On the basis of alkaline lysis of cells, it efficiently and specifically binds plasmid DNA through a new silicon-based membrane. Each adsorption column can adsorb up to 40% µ The plasmid DNA of g is effectively removed with a special buffer system to effectively remove impurities such as proteins. The yield and purity of plasmids obtained from this kit are high, and the quality is stable. It is suitable for downstream experiments such as cell transfection, DNA sequencing, PCR, PCR based mutations, in vitro transcription, transformed bacteria, and endonuclease digestion.Self prepared reagents: anhydrous ethanol, isopropanol.Preparation and important precautions before the experiment:1. All components can be stably stored for 1 year in a dry, room temperature (15-30 ℃) environment. The adsorption column can be stored for a longer time at 2-8 ℃. 2.Buffer P1 with RNase A added can be stably stored for 6 months at 2-8 ℃. Before use, add RNase A to Buffer P1 (add all RNase A provided in the reagent kit), mix well, and store at 2-8 ℃. Before use, it is necessary to leave it at room temperature for a period of time, and then use it after returning to room temperature.3.Before the first use, anhydrous ethanol should be added to the Buffer PW according to the instructions on the reagent bottle label.4. Before use, please check if there is any crystallization or precipitation in Buffer P2 and Buffer E3. If there is any crystallization or precipitation, you can take a water bath at 37 ℃ for a few minutes to restore clarity.5. Note that Buffer P2 and Buffer E3 contain irritating substances. Please wear gloves when operating and immediately cover the lid after use.6.The amount and purity of plasmid extraction are related to factors such as bacterial culture concentration, strain type, plasmid size, and plasmid copy number.7. The maximum volume of Spin Columns DM is 750 µ l. If the sample volume is greater than 750 µ L can be added in batches.Operation steps:1. Take 1-5 ml of overnight cultured bacterial solution and add it to a centrifuge tube (provided). Centrifuge at 13000 rpm (~16200 × g) for 1 minute to collect bacteria, and try to discard all the supernatant as much as possible.2. Add 200 to the centrifuge tube containing bacterial sediment µ Buffer P1 (please check if RNase A has been added first), mix thoroughly with a pipette or vortex oscillator, and suspend bacterial precipitation.Attention: If the bacterial blocks are not thoroughly mixed, it will affect the cracking effect, resulting in low extraction amount and purity.3. Add 200 to the centrifuge tube µ Buffer P2, gently invert and mix 8-10 times to fully lyse the bacterial cells. At this point, the solution should become clear and viscous.Attention: Mix gently and do not shake vigorously to avoid interrupting genomic DNA and mixing genomic DNA fragments in the extracted plasmid. If the solution does not become clear, it indicates that the bacterial count may be too large and the lysis may not be complete. The bacterial count should be reduced or the dosage of P1, P2, E3, and isopropanol should be increased proportionally.4. Add 200 to the centrifuge tube µ Buffer E3, immediately invert and mix 8-10 times, at which point white flocculent precipitates appear. Centrifuge at 13000 rpm for 5 minutes.Attention: After adding Buffer E3, it should be mixed evenly immediately to avoid local precipitation.5. Add 260 to the spin columns DM that have been loaded into the collection tube µ After adding isopropanol, immediately add the supernatant collected in step 4 and mix it upside down.Attention: After adding isopropanol, immediately add the supernatant and mix well to avoid isopropanol dripping into the collection tube after being left for a long time. The maximum volume of the adsorption column is 750 µ l. If the sample volume is greater than 750 µ l. Isopropanol and the supernatant can be collected in a centrifuge tube (provided by oneself), mixed well, and passed through the column in batches.6.13000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.7. Add 400 to the adsorption column µ L Buffer PW (please check if anhydrous ethanol has been added first), centrifuge at 13000 rpm for 1 minute, and discard the waste liquid in the collection tube.8. Place the adsorption column in a new collection tube and add 50-100 to the middle of the adsorption membrane µ Centrifuge at 13000 rpm for 1 minute using buffer EB and collect the plasmid solution into a centrifuge tube- Store the plasmid at 20 ℃.Note: 1) To increase the efficiency of plasmid recovery, the obtained solution can be added back to the adsorption column, left at room temperature for 2-5 minutes, centrifuged at 13000 rpm for 2 minutes, and collected into a centrifuge tube.2) When the plasmid copy number is low or>10 kb, preheating the buffer EB in a water bath at 65-70 ℃ can increase the extraction efficiency... Read More | DescriptionIt contains a set of six different heterogeneous palladium catalysts, useful for rapid screening of catalysis conditions. It is in sampler format with individual components packaged for multiple experiments and mini scale-up. The cost of the kit is less than the total cost of individual DescriptionIt contains a set of six different heterogeneous palladium catalysts, useful for rapid screening of catalysis conditions. It is in sampler format with individual components packaged for multiple experiments and mini scale-up. The cost of the kit is less than the total cost of individual components.Catalysis Screening Kits... Read More | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export | N665925 Component 1 mL 5 mL Storage N665925A 2×SYBR qPCR Master Mix 1 1 mL 5 mL -20℃. Avoid freeze/ Thaw cycle. N665925B qPCR Primer Mix 1 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665925C DNA Standard I 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665925 Component 1 mL 5 mL Storage N665925A 2×SYBR qPCR Master Mix 1 1 mL 5 mL -20℃. Avoid freeze/ Thaw cycle. N665925B qPCR Primer Mix 1 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665925C DNA Standard I 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665925D DNA Standard II 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665925E DNA Standard III 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665925F DNA Standard IV 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665925G DNA Standard V 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665925H 50×High ROX 40 µL 200 µL -20℃. Avoid freeze/ Thaw cycle.Product IntroductionThis product is a real-time fluorescence quantitative PCR of the products after NGS library construction using a dye method (SYBR Green I).(qPCR). The kit provides the reaction mixes, DNA primer mixtures, standards and sample dilutions required for the qPCR process, making the reagent system complete and easy to use. The fluorescent dye SYBR Green I contained in the reaction mixture can bind to all double-stranded DNA; the GoldStar Taq DNA Polymerase used is a chemically modified new high-efficiency hot-start polymerase, and the activation of the enzyme needs to be incubated at 95℃ for 10 minutes. the product has high specificity, high amplification efficiency, and is able to quickly and accurately quantify the concentration of the constructed libraries. The product is highly specific and efficient in amplification, and can quickly and accurately quantify the concentration of the constructed library.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used in Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument.Instruments that do not require ROX calibration: Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96, etc.Instruments requiring Low ROX calibration: ABI Prism7500/7500 Fast, QuantStudio®3 System, QuantStudio®5 System, QuantStudio®6 Flex System, QuantStudio®7 Flex System, ViiA 7 System, Stratagene Mx3000/Mx3005P, Corbett Rotor Gene 3000, and others.Instruments requiring High ROX calibration: ABI Prism7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, etc.Note: High Rox and Low Rox are formulated as described in Use 2.Scope of applicationThis product is designed for absolute quantification of the concentration of Ion torrent platform second generation sequencing libraries. The end of the library contains Ion torrent P5 and P7 microarray binding sequences, the length of which does not exceed 1kb, and the concentration is not less than 0.005pM can be used to perform quantitative experiments with this product. The qPCR Primer Mix provided in the kit contains the following two primer sequences:Primer 1:5'-CCA TCT CAT CCC TGC GTG TC - 3' Primer 2: 5'-CCT CTC TAT GGG CAG TCG GTG AT-3'The primer sequence can be used in advance to confirm whether the library can be amplified by that primer pair.Usage1. Amplification template preparationThe library samples to be detected were diluted with TE (10 mM Tris-Cl, pH 8.0, 1 mM EDTA), and the concentration after dilution was as close as possible to the range of 0.05-50 pM. 4°C on ice was set aside.2. qPCR reaction system preparationThe desired cryopreservation reagent is pre-melted completely and mixed by inverting several times before preparation, then centrifuged briefly and set aside.The base reaction system for 20 µl was as follows:Reagent20 µl Reaction system2×SYBR qPCR MasterMix10 µlqPCR Primer Mix 10.8 µlTemplate4 µlddH₂O5.2 µlDescription: High Rox model: add 1 µl High Rox per 50 µl of reaction system;Low Rox model: 1 µl High Rox per 500 µl of reaction system.Prepare a sufficient amount of reaction system mixture according to the need, mix well and add to the reaction wells in a volume of 16 µl per well, add the same volume of TE to the blank control, and then add the prepared standards and diluted samples to the corresponding reaction wells in a volume of 4 µl/well. It is recommended to use 20 µl reaction system, if you need to carry out a smaller system reaction, the system components can be reduced in equal proportion.3. qPCR reaction program1) Please use 60-64℃ as a reference for setting range of annealing temperature, and increase the annealing temperature when non-specific reaction occurs.2) If the average length of the library is greater than 700bp, the annealing/extension time should be increased appropriately.data analysis1. Standard curve productionThe standard curve was plotted using Ct values in the valid range. The standard curve correlation coefficient R2 should not be less than 0.99 and the slope should lie between -3.1 and -3.6. If the standard curve parameters are not reasonable, it is recommended to repeat the experiment.DNA Standard NameDNA Standard ConcentrationDNA Standard I50 pMDNA Standard II5 pMDNA Standard III0.5 pMDNA Standard IV0.05 pMDNA Standard V0.005 pM2. Library concentration calculationThe difference in Ct between the three replicate wells of the experiment should be no more than 0.2, otherwise the invalid data should be deleted or the experiment should be repeated. Do not use the Ct outside the valid Ct range of the standard curve to calculate the concentration of the diluted libraries. Please refer to the data processing Excel of this product for the specific library concentration calculation method.matters needing attention1. Before testing, these instructions should be read in detail. It should be operated by personnel with professional experience or qualified by training.2. For use, please mix gently by turning up and down, avoid foaming as much as possible, and use it after centrifugation for a short period of time.3. Avoid repeated freezing and thawing of the product, repeated freezing and thawing may degrade the performance of the product.4. When preparing the reaction solution, please use new or non-contaminated tips and centrifuge tubes to prevent contamination as much as possible... Read More |