| Description | Inquire | Product IntroductionAlamar Blue detection reagent provides a simple, rapid, reliable and safe method for cell proliferation and cytotoxicity detection, which is suitable for high-throughput detection experiments. The main component of the detection reagent is a redox indicator. In the oxidized stateProduct IntroductionAlamar Blue detection reagent provides a simple, rapid, reliable and safe method for cell proliferation and cytotoxicity detection, which is suitable for high-throughput detection experiments. The main component of the detection reagent is a redox indicator. In the oxidized state, it appears purple-blue and non-fluorescent, while in the reduced state, it turns into a reduction product with pink or red fluorescence, with an absorption peak of 530-560nm and an emission peak of 590nm.In the process of cell proliferation, the ratios of NADPH/NADP, FADH/FAD, FMNH/FMN and NADH/NAD in the cell increase and are in a reducing environment. The dye taken into the cell is reduced by these metabolic intermediates and cytochromes and then released outside the cell and dissolved in the culture medium, changing the culture medium from non-fluorescent indigo blue to fluorescent pink. Finally, use an ordinary spectrophotometer or fluorophotometer for detection, and the absorbance and fluorescence intensity are proportional to the number of active cells.Instructions1. Add 10µl of detection reagent to 100µl of cell suspension, and incubate in a cell incubator for 2-6 hours. The color of the medium changes from indigo blue to pink and you can proceed to the next step.2. It is recommended to use a fluorescence microplate reader for detection, the excitation light wavelength is between 530-560 nm, the emission light wavelength is 590 nm, and the relative fluorescence unit (RFU) is recorded.3. Draw a standard curve or cell growth curve: the ordinate (Y axis) is the relative fluorescence unit (RFU); the abscissa (X axis) is the cell number or time point or drug concentration.Precautions1. The appropriate density of cells can increase the detection sensitivity. For 96-well plates, we recommend seeding 100 microliters of cells per well. The cell concentration range is: 100-10,000/well for adherent cells, 2,000-50,000/well for suspension cells, and medium as a blank control. For 384-well plates, the cell concentration and seeding volume are both halved.2. The whole process should be aseptic operation, because microbial contaminants can also reduce the detection reagents and affect the experimental results.3. Pay attention to the concentration of inoculated cells and the incubation time after adding detection reagents. If the cell concentration is too high or the incubation time is too long, it will cause a secondary reduction reaction, resulting in colorlessness and disappearance of fluorescence.4. When incubating, avoid light.5. This product can use fluorescence or spectrophotometric detection, but the sensitivity of fluorescence is high, and the experimental error is small. Fluorescence detection is recommended... Read More | DescriptionRefer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export | Apoptosis refers to the cell autonomous and orderly death controlled by genes to maintain the stability of the internal environment. Apoptosis is different from cell necrosis. Apoptosis generally refers to a programmed cell death process that occurs during the development of body cells or under the Apoptosis refers to the cell autonomous and orderly death controlled by genes to maintain the stability of the internal environment. Apoptosis is different from cell necrosis. Apoptosis generally refers to a programmed cell death process that occurs during the development of body cells or under the action of some factors through the regulation of intracellular genes and their products. Cell necrosis is a cell death process that is caused by strong physical and chemical or biological factors to cause disordered changes in cells. The difference between apoptosis and necrosis lies in the characteristic morphological and biochemical changes, including the changes of cell membrane permeability and nuclear chromatin, the contraction of cytoplasm and the loss of membrane asymmetry. The oxazole yellow/pi membrane permeability apoptosis detection kit produced by our company is a dual fluorescence detection kit based on oxazole yellow and PI dyes. This kit is suitable for fluorescence microscopy, flow cytometry, fluorescence microplate reader and other fluorescence detection systems. Oxazole yellow is a non cell membrane penetrating cyanine monomer green fluorescent dye with high affinity for DNA. It basically has no fluorescence when it is not bound to DNA, but can emit bright green fluorescence after binding to DNA. When apoptosis occurs, the permeability of cell membrane changes. At this time, oxazole yellow can enter the cell and bind to DNA, emitting bright green fluorescence. Therefore, it is often used for the detection of apoptosis. It should be noted that oxazole yellow can also stain dead cells, so it needs to be double stained with PI that specifically fluorescently stains dead cells to effectively determine apoptosis. PI (propidium iodide) is a red fluorescent dye that can stain DNA. It is an analog of pyridine bromide that releases red fluorescence after embedding double stranded DNA. Although PI cannot pass through the membrane of living cells, it can cross the damaged cell membrane of dead cells to stain nuclei. Therefore, oxazole yellow combined with PI can be directly used for the detection of apoptosis. Apoptotic cells show green fluorescence, dead cells show both red and green fluorescence positive, and living cells have little or no fluorescence.Components: Components O598364-50T A. Oxazole yellow dye 50 µL B. Propidium Iodide (PI) 50 µLUsage (using flow cytometry as an example):1. Cell preparation(1) For adherent cells, after trypsin digestion, resuspend in culture medium and wash once with pre cooled PBS; The digestion time of trypsin should not be too long to prevent false positives. Note: Digest with trypsin and allow the cells to recover in the optimal cell culture conditions and medium for about 30 minutes, then stain.(2) For suspended cells, centrifuge at 1000 rpm for 5 minutes, discard the supernatant, and wash once with pre cooled PBS.2. Cell stainingSuspend cells in pre cooled PBS, with a recommended cell count of 106 cells/mL per sample. Add 1 µ L Oxazole Yellow and 1 µ L to 1 mL of the samplePI, Gently blow and mix well. Incubate on ice in the dark for 30 minutes. Note: We suggest adding the following two experimental controls:Blank tube: negative control group cells, without dye, used to regulate voltage.Single staining tube: Positive control group cells were treated with only two tubes, Oxazole yellow and PI, for regulating compensation.3. Flow detectionAfter incubation, the sample can be directly detected by flow cytometry, or centrifuged at 1000 rpm for 5 minutes, the supernatant can be aspirated, and the sample can be resuspended in 1 mL of pre cooled PBS for flow cytometry detection. Oxazole yellow can be excited by a 488 nm laser, and the detected fluorescence emission spectrum is around 530 ± 30 nm (FITC channel), while the PI channel emission spectrum is around 617 nm (PI or PE channel).Product parameters:Oxazole yellow dye:ex/em = 491 / 509 nm (bound DNA); Propidium iodine:ex/em = 535 / 617 nm (combined with DMatters needing attention:1. please centrifuge the product to the bottom of the tube immediately before use, and then conduct subsequent experiments. 2. fluorescent dyes have quenching problems. Please try to avoid light to slow down fluorescence quenching. 3. for your safety and health, please wear experimental clothes and disposable gloves.Scope of application:Membrane permeability apoptosis assay... Read More |