| Description | Inquire | Inquire | D665729 Component 50 T Storage D665729A Conversion Buffer CR 5×1 mL RT D665729B Buffer CL 30 mL RT D665729C Buffer MD 0.4 mL RT D665729D Buffer DB 10 mL RT D665729E Buffer WB (concentrate) 10 mL RT D665729F Buffer GW1 (concentrate) 13 mL RT D665729G Buffer GW2 (concentrate) 15 mL RT D665729H D665729 Component 50 T Storage D665729A Conversion Buffer CR 5×1 mL RT D665729B Buffer CL 30 mL RT D665729C Buffer MD 0.4 mL RT D665729D Buffer DB 10 mL RT D665729E Buffer WB (concentrate) 10 mL RT D665729F Buffer GW1 (concentrate) 13 mL RT D665729G Buffer GW2 (concentrate) 15 mL RT D665729H Buffer EB 4 mL RT D665729I Buffer PS 10 mL RT D665729J Spin Columns DF 50 Pcs 2-8 ℃ D665729K Collection Tubes 50 Pcs RTProduct Introduction:The basic principle of this reagent kit is that after DNA is treated with sodium bisulfite, unmethylated cytosine can be transformed into uracil, while methylated cytosine remains unchanged. And adopting an innovative high-temperature treatment method, the transformation time is greatly shortened, the transformation efficiency is improved, and the transformation efficiency can reach over 99%. At the same time, using a silicon-based membrane purification column, DNA can be recovered and purified from the methylated solution through a simple binding washing elution step. The recovered DNA has high purity and good integrity, and can be directly used for sequencing, methylated PCR detection, chip analysis, connection and transformation, enzyme digestion, labeling, microinjection, PCR and in vitro transcription and other molecular biology experiments.Self prepared reagents: anhydrous ethanol, 75% ethanol.Preparation and important precautions before the experiment1. Product usage method:(1) 10 times packaging preparation method: CT Conversion Agent is a solid mixture that must be prepared before first use. Add 2 ml sterile water and 100 µ M-Dissolving Buffer and 300 µ Add M-Diffusion Buffer to the CT Conversion Agent tube. Dissolve at 55 ° C and shake until completely dissolved. Store the CT Conversion Agent solution at room temperature (20 ° C-30 ° C) in the dark before use. The CT Conversion Agent for each tube is designed for 10 DNA treatments. In order to achieve better results, the prepared CT Conversion Agent should be used immediately. If not used immediately, the CT Conversion Agent solution can be stored at -20 ° C for 1 week. Before use, be sure to thaw the stored CT Conversion Agent solution at room temperature and mix thoroughly by shaking or inverting for 2 minutes, CT Conversion Reagent is sensitive to light, so it is important to minimize exposure to light as much as possible.(2) 50 times packaging preparation method: CT Conversion Agent and M-Dissolving Buffer are solid mixtures that must be prepared before first use. Add 5 ml of sterile water to the M-Dissolving Buffer and shake to dissolve. After all the solids have dissolved, transfer all the solution from the M-Dissolving Buffer tube to the CT Conversion Agent tube and add 5.5 ml of sterile water. Add 1.5 ml of M-Dilution Buffer to the CT Conversion Agent tube. Dissolve at 55 ° C and shake until completely dissolved. Store the CT Conversion Agent solution at room temperature (20 ° C-30 ° C) in the dark before use. The CT Conversion Agent for each tube is designed for 50 DNA treatments. In order to achieve better results, the CT Conversion Agent should be used immediately after preparation. If not immediately used, the CT Conversion Agent solution can be stored at -20 ° C for 1 week. Before use, be sure to thaw the stored CT Conversion Agent solution at room temperature and mix thoroughly by shaking or inverting for 2 minutes, CT Conversion Reagent is sensitive to light, so it is important to minimize exposure to light as much as possible.2. Before the first use, anhydrous ethanol should be added to the M-Wash Buffer according to the instructions on the reagent bottle label.Operation stepsThe range of DNA prepared each time is 1 ng-4 µ Between g, the optimal amount is 500 ng-2 µ G.1. Take 20 µ Add DNA sample into centrifuge tube (self provided), and if the sample amount is insufficient, replenish with water up to 20 µ L.2. Add 2.2 to the DNA sample µ Mix the sample well with the M-Dilution Buffer of l.3.42 ℃ water bath for 30 minutes.4. Add 220 to the sample obtained from the previous step µ Prepare the CT Conversion Agent solution, mix well, and incubate in an 80 ℃ constant temperature water bath in a dark place for 60 minutes.5. Add 480 to the solution in the previous step µ M - Buffer PA, gently mix upside down.6. Column balance: Add 200 to the spin columns DS that have been loaded into the collection tube µ Centrifuge at 12000 rpm (~13400 × g) for 2 minutes, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.7.Add all the solution obtained from step 5 to the adsorption column (already loaded into the collection tube), let it stand at room temperature for 2 minutes, centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.Attention: The maximum capacity of the adsorption column is 750 µ l. If the sample volume is greater than 750 µ L can be added in batches.8. Add 500 to the adsorption column µ Centrifuge at 12000 rpm for 1 minute using M-Buffer PA, discard the waste liquid from the collection tube, and place the adsorption column in the recovery tube.9. Add 650 to the adsorption column µ M-Wash Buffer (please check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column in the collection tube.10.12000 rpm for 2 minutes, discard the waste liquid, and place the adsorption column at room temperature for a few minutes to thoroughly air dry.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which will affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).11. Place the adsorption column into a new centrifuge tube (provided by oneself), and add 20 drops to the middle position of the adsorption membrane in the air µ M-Elution Buffer (pH 8.5), leave at room temperature for 2 minutes. Collect DNA solution by centrifugation at 12000 rpm for 1 minute.12. Collect 20 µ Add 2.2 to DNA µ M-Diffusion Buffer, let it stand at room temperature for 30 minutes.13. Add 500 to the solution µ After pre cooling anhydrous ethanol, invert and mix well, and place the solution at -20 ℃ to precipitate for 30 minutes (overnight precipitation is more effective).14.12000 rpm for 15 minutes and gently discard the supernatant.15. Add 75% ethanol, centrifuge at 12000 rpm for 1 minute, pour out the supernatant, wait for ethanol to evaporate at room temperature, then add 20 µ Dissolve the M-Elution buffer and store the DNA at -20 ℃. The DNA collected in this step can be used for subsequent related experiments... Read More | This product can rapidly, gently, and efficiently lyse mammalian cells, effectively extracting cytoplasmic and nuclear proteins. This reagent uses a mild formula to ensure that the extracted protein maintains biological activity and can be applied to various protein analysis experiments, such as This product can rapidly, gently, and efficiently lyse mammalian cells, effectively extracting cytoplasmic and nuclear proteins. This reagent uses a mild formula to ensure that the extracted protein maintains biological activity and can be applied to various protein analysis experiments, such as reporter gene and enzyme activity determination, immune detection, protein purification, etc. The extracted protein can be quantitatively analyzed using the BCA method. The reagent kit contains a mixture of protease inhibitors, which can effectively prevent protein degradation during the protein extraction process.M665813Component100 TStorageM665813AMammalian Protein Extraction Reagent100 mLRTM665813BProtease Inhibitor Cocktail (100×)1 mL-20℃. Avoid freeze/thaw cycle. precautions1. This product can effectively lyse adherent cells cultured on cell culture plates (without scraping) and suspended cells collected by centrifugation, with higher extraction efficiency than repeated freeze-thaw or ultrasound methods. But for the extraction of tissue proteins, it is recommended to use the tissue protein extraction kit (CW0891).The optimal dosage for protein extraction from adherent cells is listed in Table 1. Collecting cells first can reduce the amount of reagents used to obtain higher protein concentrations.3. The amount of extraction reagents used can also be estimated based on the number of cells. If 2 × 106 Hela cells weigh about 20 mg, 200 need to be added µ Extract reagents.4. The protein extracted from this product can be quantitatively analyzed using the BCA method.Operation steps● Protein extraction from adherent cells1. Please remove the required Mammalian Protein Extraction Agent for pre cooling before protein extraction.2. Carefully pour out the culture medium of adherent cells and rinse the cells with PBS.3. Add an appropriate amount of Mammalian Protein Extraction Reagent (add Protein Inhibitor Cocktail in a 1:99 ratio 2-3 minutes before protein extraction), blow adherent cells on ice with a gun tip, transfer the lysate to a centrifuge tube, incubate on ice for 20 minutes, and allow the cells to fully lyse (please refer to Appendix 1 for the amount of reagent used, and the time for placing on ice should be adjusted according to different cell types). 4. Centrifuge at 14000 × g for 5-10 minutes.5. Transfer the supernatant to a new tube for further analysis. ● Suspension cell protein extraction1. Please remove the required Mammalian Protein Extraction Agent for pre cooling before protein extraction.2. Suspend 2500 × g of cells, centrifuge for 10 minutes, and discard the supernatant. Rinse cells with PBS. 2500 × g, centrifuge for 10 minutes, discard the supernatant.3. Add an appropriate amount of Mammalian Protein Extraction Agent, and 2-3 minutes before protein extraction, add Protein Inhibitor Cocktail in a ratio of 1:99, which is 1 x working solution.4. Add at least 1 ml of 1x working solution to every 100 mg of cells. If the extracted sample size is large, a small amount of 1x working solution can be used to resuspend the cells first, and then the remaining working solution can be added.5. After blowing evenly, place it on ice for 20 minutes to allow the cells to fully lyse (the time for placing it on ice should be adjusted according to different cell types). 6. Centrifuge at 14000 × g for 15 minutes.7. Transfer the supernatant to a new tube for further analysis.Table 1. Recommended usage of extraction reagents Cell culture plate type or dish type Extraction reagent usage 100 mm 500-1,000 µl 60 mm 250-500 µl 6-well culture plate 200-400 µl /well 24-well culture plate 100-200 µl /well 96-well culture plate 50-100 µl /well Table 2. Common Problems and Solutions Problem Possible reasons Resolvent Low extraction rate Low protein expression level Optimize transfection system Low extraction rate Insufficient reagent usage Increase the usage of extraction reagents Low extraction rate Reagent unable to dissolve cell membrane Increase cracking time or increase shaking amplitude Unable to obtain membrane protein This product is more suitable for extracting nuclear plasma protein Using eukaryotic cell membrane protein extraction kit... Read More | Product content: Component O66550510 preps O665505 50 preps Blocking Buffer 100 ml 500 ml Antibody Pretreat Solution( HRP/Mouse ) 1 ml 5 × 1 ml Dilution Buffer 100 ml 500 ml Wash Buffer( 10× ) 100 ml 500 mlProduct Introduction:The one-step rapid WB assay kit (Product content: Component O66550510 preps O665505 50 preps Blocking Buffer 100 ml 500 ml Antibody Pretreat Solution( HRP/Mouse ) 1 ml 5 × 1 ml Dilution Buffer 100 ml 500 ml Wash Buffer( 10× ) 100 ml 500 mlProduct Introduction:The one-step rapid WB assay kit (mouse) is the latest Western Blot detection kit developed by Kangwei Century, which can obtain high-quality Western Blot results in about 1 hour. It is easy to operate, has high detection sensitivity, low background, does not require the addition of secondary antibodies, and has strong system stability. The conventional Western Blot indirect detection process (blocking, primary antibody binding, and secondary antibody binding) requires a long time, a complex experimental process, and requires multi-step condition optimization. After transferring the protein on the gel to the carrier membrane, incubate it with the blocking solution in the reagent kit for 5 minutes, and then incubate the carrier membrane with the primary antibody treated with antibody reaction solution. After washing three times (5 minutes each time), luminescence or colorimetric detection can be performed. This reagent kit is designed for use in experimental systems where the target protein primary antibody is derived from mice.Notes:1. The customer prepares their own mouse source primary antibody.2. Before using Blocking Buffer blocking solution, Antibody Pretreat Solution (HRP/Mouse) antibody reaction solution (mouse), and Wash Buffer (10 x) rinse solution, please mix thoroughly.3. If there is precipitation in the rinsing solution when stored at 2-8 ℃, please restore it to room temperature, dissolve the precipitation, and use it normally. The 1x rinsing solution can be stored at room temperature for one month.4. It is recommended to stain the membrane with reagents such as spring red after the transfer is completed, and cut off any excess parts on the membrane to increase the efficiency of the reagents.5. The optimal dilution amount for primary antibody and antibody reaction solution HRP (mouse) needs to be determined through preliminary experiments.6. The antibody reaction solution HRP (mouse), antibody dilution solution, and antibody dosage can be increased or decreased proportionally according to the size of the membrane.7. The antibody dilution solution containing the first antibody can be recycled and reused once. It is recommended not to reuse antibodies with poor specificity and affinity. If the recovered antibody is used within 1-2 days and stored at 2-8 ℃ for long-term storage, please freeze it at -20 ℃ to avoid repeated freeze-thaw cycles.8. If there is a high background, please adjust the amount of antibodies and increase the number of times the film is washed.9. All reagents in the reagent kit should be stored at 2-8 ℃ to avoid freezing and thawing.Operation steps:This product is suitable for the sealing and antibody incubation steps after membrane transfer, taking a 5 cm x 8 cm membrane as an example:1. Preparation of rinsing solution: Dilute 10 ml of Wash Buffer (10 x) with distilled water to 100 ml, which is 1 x Wash Buffer. Set aside. Use 8-10 ml for each film wash.2. Sealing: After the membrane transfer is completed, immerse the membrane in 10 ml Blocking Buffer and seal at room temperature for 5 minutes.3. Rinse: Pour off the sealing solution, add 8-10 ml of 1 x Wash Buffer, and rinse at a high speed on a shaker for 1 minute.4. Prepare antibody incubation solution while washing the membrane: Take Antibody Pretreat Solution (HRP/Mouse) 100 µ Add mouse derived primary antibody 3-10 into the centrifuge tube µ g. Suck and beat the gun head until thoroughly mixed, and incubate at room temperature for 5 minutes. Add to 10 ml Dilution Buffer and mix well. Note: 1) The dosage of primary antibody can also be adjusted according to the dilution of the antibody. Taking the final dilution of antibodies at 1:1000 as an example, take 100 µ Add HRP (mouse) antibody reaction solution into the EP tube and add 10 µ Add the first antibody to 10 ml of antibody diluent, mix well, and incubate at room temperature for 5 minutes. 2) If the membrane area is small, the amount of antibodies, reaction solution, and diluent can be reduced proportionally.5. After completing step 3, pour out the rinsing solution and add the antibody incubation solution mixed with primary antibody, Antibody Pretreat Solution (HRP/Mouse), and Dilution Buffer to the membrane (ensuring that the incubation solution completely submerges the surface of the membrane). Incubate at room temperature on a shaker at around 60 rpm for 40 minutes.6. Discard (recover) the antibody incubation solution and rinse 3-5 times with the prepared 1 x Wash Buffer, each time for 3 minutes. 7. Conduct subsequent testing. It is recommended to use ECL or DAB methods for testing.Application examples:Example 1 Antigen is 293T cell lysateA: Normal WB control: beta actin mouse monoclonal antibody (CW0096) 5 µ Incubate at room temperature for 40 minutes, wash the film and dilute the secondary antibody sheep anti mouse HRP (CW0102) 1:10000. Incubate at room temperature for 40 minutes and expose ECL (CW0049).B: One step method WB: beta actin mouse monoclonal antibody (CW0096) 5 µ Incubate at room temperature for 40 minutes and expose ECL (CW0049).Example 2 Antigen is E. coli multi label protein lysateC: Normal WB control: GST mouse monoclonal antibody (CW0084) 2.5 µ Incubate at room temperature for 40 minutes, wash the film and dilute the secondary antibody sheep anti mouse HRP (CW0102) 1:10000. Incubate at room temperature for 40 minutes and expose ECL (CW0049).D: One step method WB: GST mouse monoclonal antibody (CW0084) was incubated at room temperature with 2.5ug for 40 minutes, and ECL (CW0049) was exposed... Read More |