| Description | KIT Human Pre-designed siRNA Set A contains three designed siRNAs for KIT gene (Human), as well as a negative control, a positive control, and a FAM-labeled negative control. Components KIT siRNA-1: 5 nmol (HPLC) KIT siRNA-2: 5 nmol (HPLC) KIT siRNA-3: 5 nmol (HPLC) siRNA Negative Control: 5 nmol (KIT Human Pre-designed siRNA Set A contains three designed siRNAs for KIT gene (Human), as well as a negative control, a positive control, and a FAM-labeled negative control. Components KIT siRNA-1: 5 nmol (HPLC) KIT siRNA-2: 5 nmol (HPLC) KIT siRNA-3: 5 nmol (HPLC) siRNA Negative Control: 5 nmol (HPLC) FAM-labeled siRNA Negative Control: 5 nmol (HPLC) GAPDH siRNA Positive Control:5 nmol (HPLC)... Read More | DescriptionRefer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support | Glycogen and starch generate glucose-1-phosphate (1PG/G1P) during the process of phosphohydrolysis. This reagent kit provides a simple, sensitive, and rapid determination method: Glucose-1-phosphate (1PG/G1P) is reduced from NADP+to NADPH by the sequential action of phosphoglucose mutase and Glycogen and starch generate glucose-1-phosphate (1PG/G1P) during the process of phosphohydrolysis. This reagent kit provides a simple, sensitive, and rapid determination method: Glucose-1-phosphate (1PG/G1P) is reduced from NADP+to NADPH by the sequential action of phosphoglucose mutase and phosphoglucose dehydrogenase. The content of glucose-1-phosphate (1PG/G1P) in the sample can be calculated by detecting the increase in NADPH at 340nm.Composition and preparation of reagent kit: Reagent name Specifications Save requirements Remarks Extraction solution Liquid 100mL x 1 bottle 4 ℃ storage / Reagent 1 Powder mg x 1 tube 4 ℃ storage Shake or centrifuge the reagent a few times before use to make it fall to the bottom, then dissolve it in 1.2mL of distilled water for later use. Reagent 2 Powder mg x 1 tube Store at -20 ℃ Shake or centrifuge the reagent a few times before use to make it fall to the bottom, then dissolve it in 1.2mL of distilled water for later use. Reagent 3 Liquid 16mL x 1 bottle 4 ℃ storage / Reagent 4 Powder mg x 1 tube Store at -20 ℃ Shake or centrifuge the reagent a few times before use to make it fall to the bottom, then add 1 Dissolve 1mL of distilled water for later use. TRC 1 powder 4 ℃ storage Only used to identify whether the reagents in the kit are normal (not involved in result calculation). Usage: Use a pre standard tube (GIP) to shake the powder a few times until it falls to the bottom, then add 0.5mL of distilled water and mix well to dissolveDilute GIP with a concentration of 4mg/mL and then dilute it four times to 1mg/mL for later use: follow the instructions in the sample addition table for the measuring tube operationRequired instruments and supplies:ELISA reader, 96 well plate, desktop centrifuge, adjustable pipette, mortar, ice and distilled water.Determination of glucose-1-phosphate (1PG/G1P) content:1. Sample preparation① Organizational sample:Suggest weighing around 0 1g of tissue, add 1mL of extraction solution, and homogenize in an ice bath. Centrifuge at 12000rpm, 4 ℃ for 10 minutes, take the supernatant, and place it on ice for testing.[Note]: If the sample size is increased, it can be extracted in a ratio of tissue mass (g) to extraction solution volume (mL) of 1:5-10.② Bacterial/cellular samples:Collect bacteria or cells into a centrifuge tube first, centrifuge and discard the supernatant; Take about 5 million bacteria or cells and add them to 1mLExtract solution, sonicate bacteria or cells (ice bath, power 200W, sonication for 3s, interval 10s, repeated 30 times); Centrifuge at 12000rpm at 4 ℃ for 10 minutes, take the supernatant, and place it on ice for testing.[Note]: If the sample size is increased, extraction can be carried out in a ratio of 500-1000:1 of bacteria/cell quantity (104) to extraction solution (mL).③ Liquid sample: direct detection.2. Machine testing:① Preheat the enzyme-linked immunosorbent assay (ELISA) reader for at least 30 minutes and adjust the wavelength to 340nm.② Thaw the reagent to room temperature (25 ℃);③ Add reagents to the 96 well plate in the following order according to the table:② Thaw the reagent to room temperature (25 ℃);③ Add reagents to the 96 well plate in the following order according to the table: Reagent name (µL) Measurement tube Blank tube (only done once) Reagent 1 10 10 Reagent 2 10 10 Reagent 3 150 170 Sample 20 / Mix well, incubate at room temperature (25 ℃) for 20 minutes, and then read A1 at 340nm (if the A value continues to increase, the incubation time needs to be extended until the absorbance value remains unchanged within 2 minutes). Reagent 4 10 10 Mix well, incubate at room temperature (25 ℃) for 20 minutes, and then read A2 at 340nm (if the A value continues to increase, the incubation time needs to be extended until the absorbance value remains unchanged within 2 minutes). Δ A=(A2-A1) measurement - (A2-A1) blank.[Note] 1 If the difference in Δ A is hovering around zero, the sample size V1 can be increased (such as increasing to 50 µ L, the three phases of the reagent should be reduced while keeping the total volume unchanged), or the sample sampling mass W can be increased. The changed V1 and W need to be substituted into the formula for recalculation.If the A2 value exceeds 1.2, the amount of sample added V1 can be reduced (such as to 10 µ L, the three-phase reagent should be increased while keeping the total volume unchanged), or the sample can be diluted with distilled water (keeping the sample addition system unchanged), and the changed V1 and D need to be substituted into the formula for recalculation.Result calculation:1. Calculated by sample weight:1PG/G1P content (µ g/g fresh weight)=[(Δ A ÷ (ε× d) × V2 × 106 × MR] ÷ (W × V1 ÷ V) × D=836 × Δ A ÷ W × D2. Calculated by the number of cells:1PG/G1P content (µ g/104 cell)=[(Δ A ÷ (ε× d) × V2 × 106 × MR] ÷ (500 × V1 ÷ V) × D=1.7 × Δ A × D. 3. Calculated by liquid volume:1PG/G1P content (µ g/mL)=[(Δ A ÷ (ε× d) × V2 × 106 × Mr] ÷ V1=836 × Δ A ε---NADPH Molar extinction coefficient,6.22×103 L/mol/cm; d---96 Orifice plate optical diameter,0.5cm; V---Add volume of extraction solution,1 mL; V1---Add sample volume,0.02mL V2---Total reaction volume;0.2mL=2×10-4L; W---Sample quality,g; Mr---Glucose-1-phosphate(1PG/G1P)Molecular weight;260; 500---Number of cells, in millions; D---Dilution ratio,Undiluted is 1。 /... Read More | Product introduction:Griess reagent can be used for spectrophotometric detection of nitrite. The reagent contains two chemicals, sulfonic acid and n- (1-naphthyl) ethylenediamine. Under acidic conditions, sulfamic acid is converted into diazonium salt by nitrite, which can form a highly Product introduction:Griess reagent can be used for spectrophotometric detection of nitrite. The reagent contains two chemicals, sulfonic acid and n- (1-naphthyl) ethylenediamine. Under acidic conditions, sulfamic acid is converted into diazonium salt by nitrite, which can form a highly colored azo dye with n- (1-naphthyl) ethylenediamine. This dye can be detected at 548 nm: because no is extremely unstable, it is oxidized to form nitrite and nitrate. Griess indirectly reflects the content of no by detecting the content of nitrite.Matters needing attention:1. before using Griess reagent, return it to room temperature and check the solution for precipitation. If Griess reagent I contains sediment when taken out, it can be placed in a 37 ℃ water bath until the sediment dissolves. 2. this product is potentially harmful. Avoid prolonged or repeated exposure. Avoid entering eyes, skin or clothing. Please wear lab clothes and disposable gloves for operation.Scope of application:No detectionComponent:Instruction:1.Griess Reagent I and II were taken out to restore the room temperature.2.Standard dilution : The standard NaNO2 ( 1-100 µM ) was diluted with the solution used for the sample to be tested. The standard was diluted to 1 µM, 10 µM, 20 µM, 40 µM, 80 µM and 100 µM, and 100 µL standard was added to each well. If the sample concentration is too low, the range of the standard curve can be appropriately reduced ( 1 µM, 2 µM, 3 µM, 4 µM, 6 µM, 8 µM, 10 µM ).3.Sample detection :( 1 ) According to the total volume of 200 µL / hole, 100 µL / hole sample was added to the 96-well plate ; if the sample is the supernatant of the culture medium, it can be sampled directly, and if there is sediment, the supernatant should be taken after centrifugation. If the sample is a cell or tissue, it can be quickly lysed by freeze-thaw, and then centrifuged to obtain the supernatant. The volume of less than 100 µL can be diluted with diH2O or 0.9 % NaCl ( corresponding standards also need to be diluted with diH2O or 0.9 % NaCl ).( 2 ) According to 50 µL / hole, Griess Reagent I was added to each hole.( 3 ) According to 50 µL / hole, Griess Reagent II was added to each hole.( 4 ) The absorbance was measured at 540 nm. If there is no 540 nm filter, 520-560 nm filter can also be. If there is no microplate reader or a suitable filter, the concentration of nitric oxide in the sample can also be determined by visual colorimetry. A more precise concentration gradient is required for the standard when visual colorimetric... Read More | Component Description T665563Component50 TStorageApplicationT665563AVNTR3820 1 mL-20℃. Avoid freeze/thaw cycle.High resolution 3-lite VNTR detectionT665563BVNTR41201 mL-20℃. Avoid freeze/thaw cycle.High resolution 3-lite VNTR detectionT665563CVNTR32321 mL-20℃. Avoid freeze/thaw Component Description T665563Component50 TStorageApplicationT665563AVNTR3820 1 mL-20℃. Avoid freeze/thaw cycle.High resolution 3-lite VNTR detectionT665563BVNTR41201 mL-20℃. Avoid freeze/thaw cycle.High resolution 3-lite VNTR detectionT665563CVNTR32321 mL-20℃. Avoid freeze/thaw cycle.High resolution 3-lite VNTR detectionT665563DMarkerⅠ300 µL-20℃. Avoid freeze/thaw cycle.DNA Molecular Weight Standard IT665563EMarkerⅡ250 µL-20℃. Avoid freeze/thaw cycle.DNA Molecular Weight Standard IIProduct IntroductionThis kit is a genotyping product for human Mycobacterium tuberculosis based on the latest research progress in molecular epidemiology1) and optimized by process. It utilizes variable-number tandem repeats (VNTR) polymorphisms in the Mycobacterium tuberculosis genome for genotyping to differentiate clinical strains, and is a powerful tool for studying the molecular epidemiology of Mycobacterium tuberculosis and monitoring the status of tuberculosis transmission. Compared with other existing Mycobacterium tuberculosis VNTR typing systems based on the VNTR principle, this typing system has a stronger ability to discriminate strains prevalent in China1,2,3), and is therefore particularly suitable for the needs of Chinese users.By carefully optimizing the primer sequences of each PCR reaction and the composition of the premixed reaction solution, this product has a strong anti-interference power. Compared with the user's own reagents, this product significantly improves the signal intensity of specific bands and reduces the appearance of non-specific bands when using crude templates (boiling bacterial solution), which makes the experimental operation easier and quicker, and at the same time, improves the success rate of the test. The premixed reaction solution is chemically stable and can effectively withstand repeated freezing and thawing (10 times) and a longer period of time (one week) at room temperature, which is better adapted to the user's need for flexibility in the detection work.This kit is a companion product to the TB Genotyping Kit VNTR-9. For samples identified as clustered or identical strains by the VNTR-9 kit, this product can be used for finer further typing identification if necessary. The three high-resolution detection sites VNTR3820, VNTR4120 and VNTR3232 in this product can be used in combination with the nine detection sites in the VNTR-9 to increase the resolution index (Hunter-Gaston index (HGI) to 0.9931).References1) Luo T et al. Development of a hierarchical variable-number tandem repeat typing scheme for Mycobacterium tuberculosis in China. PLoS One. 2014 Feb 25. 9(2)2)Sun G et al. Discriminatory potential of a novel set of Variable Number of Tandem Repeats for genotyping Mycobacterium marinum. Vet Microbiol. 2011 Aug Vet Microbiol. 2011 Aug 26;152(1-2)3) Zhang L et al. Highly polymorphic variable-number tandem repeats loci for differentiating Beijing genotype strains of Mycobacterium tuberculosis in Shanghai, China. FEMS Microbiol Lett. 2008 May;282(1):22-31.matters needing attention1.This product is a companion to the TB genotyping kit VNTR-9. The strains to be tested should be tested by VNTR-9 typing test first, and then use this product for testing. And the results of this product should be integrated and analyzed with the results of VNTR-9.2.To avoid contamination, it is recommended that the preparation of the organisms be done within a different location than the preparation of the PCR Mix and that different pipettes be used.3.Care should be taken at all stages of sample DNA collection, extraction and amplification to ensure proper labeling and to prevent cross-contamination between different samples.4.Commonly used reagents and consumables need to be autoclaved before experimentation.5.Each tube of PCR Mix contains different primers and cannot be mixed. It can be dispensed into different amounts at once according to the experimental needs to avoid repeated freezing and thawing.6.To avoid splashing the reaction solution when opening the reaction tube, centrifuge briefly before opening the cap and collect the liquid at the bottom of the tube. In case of accidental splashing on gloves or table, change gloves immediately and wipe the table with 75% alcohol or dilute acid.7.Be careful not to cross-contaminate the PCR Mix when aspirating, and it is recommended that the pipette tip be wiped with 75% alcohol 2 times before taking Mix each time.8.Pre-experiment preparation: 1×TE buffer (PH=8.0), 0.5×TBE buffer, agarose, ethidium bromide (EB), normal PCR instrument, DNA electrophoresis equipment and gel imager, 0.2 ml PCR reaction tubes, octuplex or 96-well PCR tubes, pipettes of different sizes: 0.5-10 µl and 20-200 µl.Operation steps1. DNA template preparation:1.1. scrape a small amount (1-2 inoculation loops) of sample from solid medium, resuspend in 100ul TE and inactivate at 80°C for 30 minutes.1.2. The inactivated strain was taken out of the P3 laboratory as follows:Boil at 100°C for 10 minutes (be careful to avoid bursting the cap of the EP tube during boiling to avoid letting water into the tube), place immediately on ice for 2 minutes, centrifuge at 12,000 rpm (~13,400 × g) for 10 minutes, take the supernatant and place in another sterile EP tube, label it, and store at -20°C.2. Testing procedures:2.1. Remove the TB Genotyping Kit HV-3, allow the liquid to equilibrate to room temperature, mix by shaking slightly 3-4 times, and then centrifuge at 12,000 rpm (~13,400 x g) for 5 seconds to allow the capped liquid to fall back into the tube.2.2.Three-locus VNTR typing: strains with identical results at 12 loci need to be further VNTR typed, i.e., the following four loci are added for comparison.1)PCR amplification: the reaction system was 20 µl. 19 µl of PCR Mix of VNTR3820, VNTR4120, and VNTR3232 were added to each PCR tube, 1 µl of DNA template was added, and mixed well.2)Amplification conditions:3) Gel preparation and electrophoresis:a: Notes:Important! Positive (H37Rv strain DNA) and negative controls (deionized water) need to be set up for each experiment.Key! This experiment is based on agarose gel electrophoresis to interpret the genotype of VNTR locus, therefore, in order to make the results accurate, it is necessary to follow the unified standard operation in this step of electrophoresis, and the following points should be noted:a-1: The comb used for glue making is 18 holes.a-2: The two wells on the left and right sides of the gel were discarded due to the tendency to distort the bands during electrophoresis, affecting the interpretation of the results, or a negative control was spotted in one of the wells. The remaining 16 wells were divided into 12 samples, 3 DNA Markers and 1 positive control. The order of spotting was "1, 2, M, 3, 4, 5, 6, M, 7, 8, 9, 10, M, 11, 12, H37Rv", the numbers represent samples, and M represents DNA Marker.a-3: When PCR amplification products are subjected to the first electrophoresis and Marker I is used, the gel concentration is 1%, the voltage is 150 V, and the time is 100-120 min.a-4: If the amplification product fragment is too large (>1000bp) and needs to be electrophoresed again and Marker II is used, the gel concentration is 0.8%, the voltage is 150V and the time is 150 minutes.b: Gluing as well as the electrophoresis process:PCR amplification products were electrophoresed using a 1% agarose gel.To prepare 1% agarose gel, 12×12 cm gel tray was used to make the gel, each gel was 80 ml.b-1: Weigh 0.8g of agarose, add 80ml of 0.5×TBE, weigh it on the balance and put it into the microwave oven, heat it on high for 2-3 minutes to make the agarose dissolve completely, shake it well, and observe it as a homogeneous and transparent solution without particles, then weigh it again on the balance and make up the appropriate amount of double-distilled water to keep the concentration of the gum unaffected.b-2: When the melted gel was cooled to about 55°C add 4 µl of ethidium bromide (10ug/ml) and gently swirl to mix well. The gel was made with an 18-tooth comb and the warm gel was poured into a 12 × 12 cm gel tray.b-3: Allow the gel to completely set (40 minutes at room temperature), carefully pull out the comb, remove the tray, and place it in the electrophoresis tank. Add 0.5× TBE buffer to the electrophoresis tank, not exceeding the gel surface by 1-2mm.b-4: Sample electrophoresis: add 12 samples to each gel (the topmost wells are not sampled), add 3-5µl PCR products to each well, and at the same time add three 5µl DNA MarkerⅠ to each gel. The voltage is 150V and the electrophoresis time is 100-120 minutes. This step is the key to the accuracy of the final readings of each point, and needs to be operated uniformly according to this standard.b-5: Some loci have amplification products greater than 1000bp in clinical strains, and these amplification products were then electrophoresed using 0.8% agarose gel, with DNA Marker II added as a control for the band size, voltage 150V, electrophoresis time 150 minutes.4) Results display:5) Analysis of results:a. If the genotypes of the three highly variable loci are also the same in different strains, they can be identified as clustered strains;b. If the high variant readings are highly similar, i.e., only 1-2 high variant sites are different, they need to be combined with epidemiologic data to identify if they are clustered strains;c. If all 3 high variant loci are genotypically discordant, identify as a single strain.Appendix 1: Rules for reading VNTR lociAppendix 2: VNTR locus repeat unit readout table... Read More |