| Description | The AO/PI Double Staining Kit is a detection system based on fluorescent nucleic acid dyes, designed to quickly and reliably distinguish live, apoptotic, and necrotic cells in biological samples. Its core principle utilizes the differences in cell membrane permeability and the specific The AO/PI Double Staining Kit is a detection system based on fluorescent nucleic acid dyes, designed to quickly and reliably distinguish live, apoptotic, and necrotic cells in biological samples. Its core principle utilizes the differences in cell membrane permeability and the specific fluorescent reactions upon binding to nucleic acids of the two dyes, Acridine Orange (AO) and Propidium Iodide (PI). AO can penetrate the cell membranes of all cell types (live, apoptotic, and necrotic). After entering the cell, AO binds to nucleic acids, but its fluorescence color depends on the target: when it binds to double-stranded DNA (dsDNA) in the nucleus, it emits green fluorescence (Ex 488 nm, Em 530 nm); whereas when it binds to single-stranded DNA (ssDNA) or RNA, it emits red fluorescence (Em >640 nm). In contrast, PI cannot penetrate cells with intact cell membranes. It only enters late apoptotic and necrotic cells, whose cell membranes have been compromised, and binds to DNA to produce red fluorescence (Ex 535 nm, Em 617 nm). Therefore, after AO/PI double staining, observation under a fluorescence microscope allows clear differentiation of cells in different states: live cells display normal green fluorescence; early apoptotic cells show bright green speckled nuclear morphology (only AO enters); late apoptotic and necrotic cells appear orange-red or strong red fluorescence due to the combined effect of AO and PI.Product InformationA1492198Components100T500TStorageQuantity Per TestA1492198AAO Staining Solution100µL500µL2-8℃, Store in the dark.1µL per 0.5-1.0 x 10⁶ cellsA1492198BPI Staining Solution500µL2500µL-20℃. Store in the dark.5µL per 0.5-1.0 x 10⁶ cellsA1492198CAO/PI Dilution Buffer10mL50mL2-8℃0.1mL per 0.5-1.0 x 10⁶ cellsNote: The recommended number of cells to stain per test is 0.5-1.0 x 10⁶ cells.Procedure1. Preparation of Working Solution(1) Take out the reagents and allow them to reach room temperature. Dilute the AO/PI Dilution Buffer 10-fold with double-distilled water before use.(2) Prepare the AO/PI Staining Working Solution: The concentration of AO stock solution in this product is 10 mg/mL, and PI stock solution is 1 mg/mL. Add 50 µL of PI stock solution and 10 µL of AO stock solution to 10 mL of diluted AO/PI Dilution Buffer. Vortex to mix well, resulting in 10 mL of AO/PI Staining Working Solution.Note: Since optimal staining conditions may vary with cell type, it is recommended that users determine the appropriate dye concentration individually based on practical conditions.2. Staininga. For Adherent Cells:(a) Seed cells in culture dishes, multi-well plates, or on coverslips, and treat the cells as required by the experimental design. Gently aspirate the medium from the wells and wash with PBS for about 10 seconds, then remove the PBS.(b) Add an appropriate volume of AO/PI Staining Working Solution, and gently swirl to ensure the dye evenly covers all cells.Note: For adherent cells cultured in 6-well plates with a confluency over 80%, it is recommended to add 1 mL of staining working solution per well. This can be optimized according to the specific experimental setup.(c) Incubate the cells at room temperature, protected from light, for 1-10 minutes.(d) Aspirate the staining solution, wash 2-3 times with PBS, then add serum-free culture medium. Observe immediately under a fluorescence microscope: observe AO-DNA green fluorescence at Ex/Em = 488/530 nm, and PI-DNA red fluorescence at Ex/Em = 535/617 nm. Alternatively, analysis by flow cytometry or detection with a fluorescence microplate reader can be performed after staining.b. For Suspension Cells:(a) After treating the cells as required by the experimental design, count the cells. Take an appropriate number of cells, centrifuge at 500 × g for 5 minutes at room temperature, gently aspirate the medium, resuspend in an appropriate amount of PBS, and centrifuge again at 500 × g for 5 minutes at room temperature to remove the PBS.(b) Add an appropriate amount of AO/PI Staining Working Solution to achieve a cell density of approximately 10⁶ cells/mL.(c) Incubate the cells at room temperature, protected from light, for 1-10 minutes.(d) Place a drop directly on a glass slide, cover with a coverslip, and observe under a microscope: observe AO-DNA green fluorescence at Ex/Em = 488/530 nm, and PI-DNA red fluorescence at Ex/Em = 535/617 nm. Alternatively, analysis by flow cytometry or detection with a fluorescence microplate reader can be performed after staining.Note: If background interference is significant, centrifuge to remove the staining solution, wash 1-2 times with PBS, and then observe under the microscope.Precautions1. AO/PI staining solutions are somewhat toxic; handle with care. 2. For your safety and health, please wear a lab coat and disposable gloves.3. Fluorescent dyes are subject to quenching; it is recommended to complete detection on the same day after staining whenever possible... Read More | Calcein AM /PI Double Staining Kitis utilized for simultaneous fluorescence staining of viable and dead cells. This kit contains Calcein-AM and Propidium Iodide (PI) solutions, which stains viable and dead cells, respectively(Fig. 1). Calcein-AM, an acetoxymethyl ester of calcein, is highly Calcein AM /PI Double Staining Kitis utilized for simultaneous fluorescence staining of viable and dead cells. This kit contains Calcein-AM and Propidium Iodide (PI) solutions, which stains viable and dead cells, respectively(Fig. 1). Calcein-AM, an acetoxymethyl ester of calcein, is highly lipophilic and cell membrane permeable. Though Calcein-AM itself is not a fluorescent molecule, the calcein generated from Calcein-AM by esterase in a viable cell emits a strong green fluorescence (excitationat 490 nm, emission at515 nm). Therefore, Calcein-AM only stains viable cells. On the other hand, PI, a nuclei staining dye, cannot pass through a viable cell membrane. It reaches the nucleus by passing through disordered areas of dead cell membrane, and intercalates with the DNA double helix of the cell to emit red fluorescence (excitation: 535 nm,emmision: 617 nm). Since both calcein and PI-DNA can be excited with 490 nm, simultaneous monitoring of viable and dead cells is possible with a fluorescence microscope. With 545 nm excitation, only dead cells can be observed (Fig. 1). Since optimal staining conditions differ from cell line to cell line, we recommend that a suitable concentration of PI and Calcein-AM be individually determined. Please note that PI is suspected to be highly carcinogenic;careful handling is required.Required Equipment and Materials:Microscope with 490 nm excitation filter and 530 nm emission filter;CO2incubator;10 µl and 200 µl adjustable pipettes, PBSSolution A (Calcein-AM);Solution B (PI) Storage Condition: -20oC ;Shipping Condition: blue ice.Application:Assay Procedure1)Add 2.5 µl Solution A and 12.5 µl Solution B to 5 ml PBS to prepare assay solution.*2)Wash the cell with PBS several times to remove residual esterase activity.3)Add 100uLof assay solution to200uL105~106CELLSsolution and incubate the mixture at 37oC for 15 min.4)Detect fluorescence using a fluorescence mircoscope with 490 nm excitationfor simultaneous monitoring of viable and dead cells.With 545 nm excitation, only dead cells can be observed.*The following steps may be necessary tooptimizethe suitable concentration of each reagent:1)Prepare dead cells by 10 min incubation in 0.1% saponin or 0.1-0.5% digitonin or by 30 min incubation in 70% ethanol.2)Stain dead cells with 0.1-10 µM PI solution to find a PI concentration that stains the nucleus only, not the cytosol.3)Stain dead cells with 0.1-10 µM Calcein-AM solution to find a Calcein-AM concentration that does not stain the cytosol. Then stainviable cells with that Calcein-AM solution to check whether the viable cell can be stained... Read More | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export | Products contentN665968Component96 TStorageN665968Adex N501-N508 Primers for Illumina 8×12 µL-20℃. Avoid freeze/thaw cycle.N665968BIndex N701-N712 Primers for Illumina 12×8 µL-20℃. Avoid freeze/thaw cycle. Products IntroductionThis kit is a companion kit for the Products contentN665968Component96 TStorageN665968Adex N501-N508 Primers for Illumina 8×12 µL-20℃. Avoid freeze/thaw cycle.N665968BIndex N701-N712 Primers for Illumina 12×8 µL-20℃. Avoid freeze/thaw cycle. Products IntroductionThis kit is a companion kit for the transposase-based second-generation sequencing Rapid DNA Library Construction Kit, designed for Illumina platform library construction, which contains 8 primers at the N5 end and 12 primers at the N7 end, which can be used to prepare 96 different bipartite Index libraries. All reagents provided in the kit have been subjected to stringent quality control and functional validation to maximize the stability and reproducibility of library construction. The prepared libraries can be sequenced on Illumina platforms such as HiSeq X-10/4000/2500/2000 and MiSeq. Provide your own instruments, reagents and consumables1. Magnetic frame: DynaMagTM-2 is recommended.2. DNA purification and recovery kit: It is recommended to use Kangwei DNA purification and recovery kit by magnetic bead method.3. DNA building kit: It is recommended to use the Kangwei Century transposase method second-generation sequencing rapid DNA building kit.4. Anhydrous ethanol.5. Reaction tubes: It is recommended to use low adsorption PCR tubes and 1.5 ml centrifuge tubes; tips: It is recommended to use high-quality filtration tips to prevent contamination of reagent kits and library samples. Pre-experiment Preparation and Important NotesPlease centrifuge briefly before opening the cap so that the liquid collects at the bottom of the tube to avoid cross-contamination between different primers.For the use of the CombiVision Second Generation Sequencing Multisample Primer Kit, please follow the CombiVision Second Generation Sequencing Rapid DNA Library Kit protocol.Index N501-N508 Primers for IlluminaIndex N701-N712 Primers for Illumina... Read More | Inquire |