| Description | Inquire | This reagent kit is suitable for simultaneously isolating and purifying genomic DNA, total RNA, and total protein from the same cell or tissue sample. This product does not require dividing the sample into three parts to extract DNA, RNA, and protein separately, nor does it require dividing the This reagent kit is suitable for simultaneously isolating and purifying genomic DNA, total RNA, and total protein from the same cell or tissue sample. This product does not require dividing the sample into three parts to extract DNA, RNA, and protein separately, nor does it require dividing the purified total nucleic acid into two parts before purifying DNA and RNA separately. Therefore, it can maximize the recovery of DNA, RNA, and protein, and can be used for the purification of nucleic acid and protein in small and rare samples. The purified DNA, RNA, and protein can be eluted separately and directly applied to various downstream molecular biology operations. This reagent kit does not contain toxic substances such as phenol and chloroform, and does not require ethanol precipitation. The operation is simple and fast. The extracted genomic DNA can be used for PCR, Real time PCR, SouthBlot, Dot Blot, comparative genomic hybridization (CGH), gene analysis, and SNP analysis; Total RNA can be applied in experiments such as RT-PCR, cDNA synthesis, Northern Blot, Dot Blot, and gene chips; Total protein can be applied in electrophoresis and Western Blot, among others. A665492 Component 50 T Storage A665492A Buffer RL 35 mL RT A665492B Buffer RW1 40 mL RT A665492C Buffer RW2 (concentrate) 11 mL RT A665492D RNase-Free Water 10 mL RT A665492E Buffer GW1 (concentrate) 13 mL RT A665492F Buffer GW2 (concentrate) 15 mL RT A665492G Buffer GE 15 mL RT A665492H Buffer PZ 60 mL RT A665492I Buffer PLS 15 mL RT A665492J Spin Columns DM with Collection Tubes 50 sets RT A665492K Spin Columns RM with Collection Tubes 50 sets RT A665492L Collection Tubes 100 EA RT A665492M RNase-Free Centrifuge Tubes (1.5 mL) 100 EA RTSelf prepared reagents:β- Mercaptoethanol (for newly opened or RNA extraction), 70% ethanol (prepared with water without RNase), and anhydrous ethanol.Preparation and important precautions before the experiment:To prevent RNase pollution, attention should be paid to the following aspects:1) Use plastic products and gun heads without RNase to avoid cross contamination.2) Glassware should be dry baked at a high temperature of 180 ℃ for 4 hours before use, while plastic containers can be soaked in 0.5 M NaOH for 10 minutes, thoroughly rinsed with water, and then sterilized under high pressure.3) The solution should be prepared using water without RNase.4) Operators should wear disposable masks and gloves, and change gloves frequently during the experiment.2. The sample should avoid repeated freeze-thaw cycles, otherwise it will affect the quality of DNA, RNA, and protein extraction. The sample can be stored in Buffer RL at -70 ℃ for one month.3. Please add Buffer RL before use β- Mercaptoethanol, 1 ml Buffer RL with 10 µ L β- Mercaptoethanol. join β- The buffer RL room temperature of mercaptoethanol can be stored for one month.Before the first use, anhydrous ethanol should be added to Buffer RW2, Buffer GW1, and Buffer GW2 according to the instructions on the reagent bottle label.5. Before use, please check if there is any crystallization or precipitation in the Buffer RL. If there is any crystallization or precipitation, please dissolve it again in a 56 ℃ water bath.6. All centrifugation steps are performed using a desktop centrifuge at room temperature. Operation steps:1. Material processing1a The cells cultured on the wall should be first processed into cell suspension (maximum extraction amount of 107 cells), collected cells, discarded the culture medium, and added 600 cells µ L Buffer RL (check if it has been added before use) β- Mercaptoethanol), repeatedly blow and beat to fully decompose.Attention: It is necessary to discard the culture medium completely, otherwise it will affect the lysis and subsequent nucleic acid purification steps.1b Take no more than 30 mg of animal tissue, grind it into fine powder with liquid nitrogen, and add 600 µ Buffer RL (check if it has been added before use) β- Mercaptoethanol, or directly add 600 µ L Buffer RL (check if it has been added before use) β- Mercaptoethanol, homogenization treatment.Attention: The homogenate should be sufficient, otherwise it will affect RNA production.2. Centrifuge the solution obtained in the previous step at 12000 rpm (~13400 × g) for 3-5 minutes. Carefully add the supernatant to the spin columns DM that have been loaded into the collection tube. Centrifuge at 12000 rpm for 30-60 seconds and collect the filtrate. Place the adsorption column DM in a new 2 ml collection tube at room temperature or 4 ℃ for DNA extraction. Attention: Ensure that there is no liquid residue on the adsorption column, and if necessary, repeat centrifugation until all liquids pass through the membrane of the adsorption column. Total RNA extraction3. Add 1 volume of 70% ethanol (prepared without RNase water) to the filtrate obtained in step 2, and mix well.4. Add all the solution obtained in the previous step to the spin columns RM that have been loaded into the collection tube. If the solution cannot be added completely at once, it can be transferred in stages. Centrifuge at 12000 rpm for 20 seconds and retain the liquid in the collection tube for protein extraction.5. Place the adsorption column RM into a new 2ml collection tube and add 700 to the adsorption column RM µ L Buffer RW1, centrifuge at 12000 rpm for 20 seconds, discard the waste liquid in the collection tube, and place the adsorption column RM into the recovery manifold.6. Add 500 to the adsorption column RM µ Buffer RW2 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 20 seconds, discard the waste liquid in the collection tube, and place the adsorption column RM back into the 2 ml collection tube.7. Repeat step 6.Centrifuge at 8.12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry. Attention: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).9. Place the adsorption column RM in a new 1.5 ml centrifuge tube without RNase, and add 30-50 to the middle of the adsorption column RM µ Place RNase Free Water at room temperature for 2-5 minutes, centrifuge at 12000 rpm for 1 minute, collect RNA solution, and store RNA at -70 ℃ to prevent degradation.Attention:1) The volume of RNase Free Water should not be less than 30 µ l. Small volume affects the recovery rate.2) If you want to increase RNA production, you can use 30-50 µ Repeat step 9 for the new RNase Free Water.3) If you want to increase the RNA concentration, you can add the obtained solution back to the adsorption column and repeat step 9.Genomic DNA extraction10. Add 500 to the adsorption column DM µ Buffer GW1 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 20 seconds, discard the waste liquid in the collection tube, and place the adsorption column DM into the recovery tube.11. Add 500 to the adsorption column DM µ Buffer GW2 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 2 minutes, discard the waste liquid in the collection tube, and place the adsorption column DM into the recovery tube. Attention: To further improve DNA purity, repeat step 11.Centrifuge at 12.12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column DM at room temperature for a few minutes to thoroughly dry the ethanol in the column. Attention: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).13. Place the adsorption column DM in a new centrifuge tube and add 100 to the middle of the adsorption column DM by suspending it in the air µ L Buffer GE, leave at room temperature for 2-5 minutes, centrifuge at 12000 rpm for 2 minutes, collect DNA solution, and store DNA at -20 ℃.Attention:1) The volume of Buffer GE should not be less than 100 µ l. Small volume affects the recovery rate.2) If we want to increase DNA production, we will µ Add a new Buffer GE to the adsorption column and repeat step 13; If you want to increase the DNA concentration, you can add the DNA eluent obtained in step 13 back onto the adsorption column and repeat step 13.Protein extraction14. Add 1 volume of Buffer PZ to the RNA extraction effluent (i.e. the solution obtained in step 4), mix well, and let it stand at room temperature for 10-30 minutes.Centrifuge at 15.12000 rpm for 10 minutes and discard the supernatant.16. Add 500 µ Centrifuge at 12000 rpm for 1 minute with 70% ethanol, and try to absorb the supernatant as much as possible.17. Place the centrifuge tube at room temperature for a few minutes to dry the precipitate.Attention: The purpose of this step is to remove residual ethanol. Excessive drying can make protein precipitation difficult to dissolve, and incomplete drying of residual ethanol can affect protein loading.18. Add 100 µ L Buffer PLS to obtain protein solution.Attention:1) The protein samples obtained by dissolving with Buffer PLS are suitable for SDS-PAGE and Western Blot detection, but not for Bradford method for protein quantification. If Bradford method is needed for protein quantification, 5% SDS can be used to dissolve the protein, or suitable protein dissolution buffer can be selected based on downstream experiments.2) The amount of dissolved protein buffer added is determined based on the initial sample size and specific downstream test requirements.3) The dissolved protein can be stored at -20 ℃ for several months and at 2-8 ℃ for several days.If protein samples require SDS-PAGE electrophoresis, the following operations can be performed:19. Add protein loading buffer to the protein sample, denature at 95 ℃ for 5-10 minutes, and cool the sample to room temperature. Centrifuge at 20.12000 rpm for 1 minute, extract the supernatant for downstream SDS-PAGE or Western blot tests... Read More | DescriptionThe 200 nm Coupling Kit makes conducting lateral flow tests and biomolecule separation (including cell separation) easier and more flexible. The Kit contains AnteoBind™activated 200 nm magnetic particles that give you increased antibody binding capacity and functionality, while the DescriptionThe 200 nm Coupling Kit makes conducting lateral flow tests and biomolecule separation (including cell separation) easier and more flexible. The Kit contains AnteoBind™activated 200 nm magnetic particles that give you increased antibody binding capacity and functionality, while the included blocking buffer decreases background noise.Reduce reagent preparation time; remove traditional surface preparation steps such as EDC and replace these steps with the 200 nm pre-activated magnetic particles provided. This Kit reduces aggregation and gives you the freedom and ability to produce multifunctional particles for diverse applications, including dual labelling.For lateral flow tests, magnetic particles are easier to handle than gold. Magnetic separation removes the need to perform centrifugation and filtration concentration. Magnetic particles can provide greater sensitivity than gold during lateral flow tests.Binding Capacity and Polydisperity IndexBinding Capacity: > 50 µg IgG/mgPolydispersity Index (PdI)*: < 0.3* The Polydispersity Index (PdI) is dimensionless and determined using Dynamic Light Scattering (DLS). The PdI is scaled such that values smaller than 0.05 are rarely seen and values greater than 0.7 indicate that the sample has a very broad size distribution and poor monodispersity.Particle based Immunoassays, Lateral Flow, Bioseparations and Immunoprecipitation... Read More | DescriptionWhite LED Array for Photo KitAlysis high-throughput screening platform. For use with Photo KitAlysis Starter Kit (Z742612). User guide is provided in the below hyperlink.Photo KitAlysis Operating InstructionsFeatures:Designed and tested by synthetic chemists.Controller provides repeatableDescriptionWhite LED Array for Photo KitAlysis high-throughput screening platform. For use with Photo KitAlysis Starter Kit (Z742612). User guide is provided in the below hyperlink.Photo KitAlysis Operating InstructionsFeatures:Designed and tested by synthetic chemists.Controller provides repeatable milliamp selection for photon intensity (sold seperately)0-30 mA variable LED outputNon-magnetic LED baseChemically resistant LED coverPTFE coated cablingPhoto Kitalysis Starter Kitrequired for operation (sold separately). Best when used withKitAlysis Benchtop Inertion Box(sold separately)... Read More | Products content S666097Component200 TStorageS666097A5×SuperFast One Step RT-qPCR U+ Buffer1 mL-20℃. Avoid freeze/thaw cycle.S666097BSuperFast One Step U+ Enzyme200 µL-20℃. Avoid freeze/thaw cycle.S666097CRNase-Free Water2×1.5 mL-20℃. Avoid freeze/thaw cycle. Products content S666097Component200 TStorageS666097A5×SuperFast One Step RT-qPCR U+ Buffer1 mL-20℃. Avoid freeze/thaw cycle.S666097BSuperFast One Step U+ Enzyme200 µL-20℃. Avoid freeze/thaw cycle.S666097CRNase-Free Water2×1.5 mL-20℃. Avoid freeze/thaw cycle. Products IntroductionThe SuperFast Probe One Step RT-qPCR U+ Kit is designed for quantitative PCR assays using RNA as a template (e.g., RNA viruses). Using gene-specific primers (GSP), reverse transcription and qPCR reactions are completed in a single tube, eliminating the need for additional tube-opening/pipetting operations, greatly increasing throughput and reducing the risk of contamination. The dUTP/UNG anti-contamination system is introduced in this kit. The heat-sensitive UNG rapidly degrades U-containing contaminants at room temperature; it is rapidly inactivated by reverse transcription at 55°C, without affecting the efficiency and sensitivity of qRT-PCR. Combined with optimized buffer systems and antibody-modified Taq enzymes and mutated M-MLV, the SuperFast Probe One Step RT-qPCR U+ Kit provides sensitivity up to 0.1 pg of total RNA or <10 copies of RNA template and enhanced thermal stability. 5× SuperFast One Step RT-qPCR U+ Buffer contains the following components The 5× SuperFast One Step RT-qPCR U+ Buffer contains an optimized buffer system and dNTP/dUTP Mix, which is particularly suitable for high specificity, low template concentration and multiplexed rapid detection of fluorescently labeled probes such as TaqMan. caveatBefore use, please mix the product gently by turning it up and down after it is completely melted to avoid foaming, and use it after brief centrifugation. Avoid repeated freezing and thawing of the product.ROX dye is used to correct the fluorescence signal error between the quantitative PCR wells, this product does not contain ROX dye, if you need to match the ROX dye with the instrument you are using, please contact your local business or call CombiSense customer service at 4006-222-360. PCR reaction system Attention: (1) Usually, the final primer concentration of 0.2 µM can get better results, and 0.1-1.0 µM can be used as a reference for setting the range. If the amplification efficiency is not high, the concentration of primer can be increased; if non-specific reaction occurs, the concentration of primer can be decreased to optimize the reaction system.(2) The final concentration of the probe used is related to the fluorescence quantitative PCR instrument used, the type of probe, and the type of fluorescent labeling substance, please refer to the instrument manual or the specific requirements for the use of each fluorescent probe to adjust the concentration.3) Because templates from different species contain different numbers of copies of the target gene, the template can be diluted in a gradient to determine the optimal amount of template to usePCR reaction conditionsmovetemptimingcirculatereverse transcription55°C1 min1premutability95°C10s1)1denaturation95°C1 s40-45Annealing/Extension55-60°C2)10-15s3)40-45Attention: (1) The enzyme used in this product is activated under the condition of pre-denaturation at 95℃ for 30s. Under this condition, most of the templates can be well unchained. For templates with high GC content and complex secondary structure, the pre-denaturation time can be extended to 1min, so as to make the starting template fully unchained, and if the high temperature treatment time is too long, it will affect the activity of the enzyme; for simple templates, pre-denaturation time of 1-10s can also be used, and the optimal pre-denaturation time can be determined according to the template situation.(2) It is recommended to use two-step PCR reaction program, the annealing temperature should be 55-60℃ as the reference range, and the annealing temperature can be increased when non-specific reaction occurs. If you can't get good results due to the use of primers with low Tm values or long amplification products, you can try three-step PCR amplification.3) Whether the actual Real Time PCR instrument used supports rapid amplification cycles, please perform a pre-experiment to verify this for the first attempt... Read More |