| Description | Annexins are a family of calcium-dependent phospholipid-binding proteins that preferentially bind phosphatidylserine (PS). Under normal physiologic conditions, PS is predominantly located in the inner leaflet of the plasma membrane. Upon initiation of apoptosis, PS loses its asymmetric distribution Annexins are a family of calcium-dependent phospholipid-binding proteins that preferentially bind phosphatidylserine (PS). Under normal physiologic conditions, PS is predominantly located in the inner leaflet of the plasma membrane. Upon initiation of apoptosis, PS loses its asymmetric distribution across the phospholipid bilayer and is translocated to the extracellular membrane leaflet marking cells as targets of phagocytosis. Once on the outer surface of the membrane, PS can be detected by fluorescently labeled Annexin V in a calcium-dependent manner. In early-stage apoptosis, the plasma membrane excludes viability dyes such as propidium iodide (PI), 7-AAD. These cells will stain with Annexin V but not a viability dye, thus distinguishing cells in early apoptosis. However, in late stage apoptosis, the cell membrane loses integrity thereby allowing Annexin V to also access PS in the interior of the cell. A viability dye can be used to resolve these late-stage apoptotic and necrotic cells (Annexin V, viability dye-positive) from the early-stage apoptotic cells (Annexin V positive, viability dye-negative). This kit is suitable for the identification and enumeration of dead cells, such as apoptotic or necrotic cells, by flow cytometry. A1456539Components20T50T100TStorageQuantity Per TestA1456539A10× Annexin V Binding Buffer5 mL10 mL20 mL2-8℃200 µL per 0.5-1.0x10⁵ cellsA1456539BAnnexin V -AF64740 µL100 µL200 µL2-8℃. Store in the dark.2 µL per 0.5-1.0x10⁵ cellsA1456539C7-AAD Staining Solution 40 µL 100 µL200 µL2-8℃. Store in the dark.2µL per 0.5-1.0x10⁵ cellsNote: The recommended number of cells to stain per test is 0.5-1.0x10⁵ cells. Precautions 1. 1. Please try to avoid light when using to slow down the quenching of fluorescence. 2. 7-AAD Solution is toxigenic and mutagenic; handle with care. 3. Due to the calcium dependence of the Annexin V:PS interaction, it is critical to avoid buffers containing EDTA or other calcium chelators during Annexin V experiments. Instruction for use 1. Dilute 10x Binding Buffer to 1x using distilled water (1 mL 10x Binding Buffer + 9 mL ddH2O). 2. Wash cells twice with cold PBS and then resuspend the desired amount of cells in Annexin V Binding Buffer at a concentration of 1.0-5.0 x 106 cells/mL. 3. Add 2 µl of AF647 Annexin V and 2 µl 7-AAD to 100 µL of the cell suspension. 4. Add 100 µL of 1x Binding Buffer to each assay. Gently vortex the cells and incubate for 10 min at RT (25°C) in the dark. 5. Analyze by flow cytometry within 1 hr... Read More | This reagent kit is suitable for simultaneously isolating and purifying genomic DNA, total RNA, and total protein from the same cell or tissue sample. This product does not require dividing the sample into three parts to extract DNA, RNA, and protein separately, nor does it require dividing the This reagent kit is suitable for simultaneously isolating and purifying genomic DNA, total RNA, and total protein from the same cell or tissue sample. This product does not require dividing the sample into three parts to extract DNA, RNA, and protein separately, nor does it require dividing the purified total nucleic acid into two parts before purifying DNA and RNA separately. Therefore, it can maximize the recovery of DNA, RNA, and protein, and can be used for the purification of nucleic acid and protein in small and rare samples. The purified DNA, RNA, and protein can be eluted separately and directly applied to various downstream molecular biology operations. This reagent kit does not contain toxic substances such as phenol and chloroform, and does not require ethanol precipitation. The operation is simple and fast. The extracted genomic DNA can be used for PCR, Real time PCR, SouthBlot, Dot Blot, comparative genomic hybridization (CGH), gene analysis, and SNP analysis; Total RNA can be applied in experiments such as RT-PCR, cDNA synthesis, Northern Blot, Dot Blot, and gene chips; Total protein can be applied in electrophoresis and Western Blot, among others. A665492 Component 50 T Storage A665492A Buffer RL 35 mL RT A665492B Buffer RW1 40 mL RT A665492C Buffer RW2 (concentrate) 11 mL RT A665492D RNase-Free Water 10 mL RT A665492E Buffer GW1 (concentrate) 13 mL RT A665492F Buffer GW2 (concentrate) 15 mL RT A665492G Buffer GE 15 mL RT A665492H Buffer PZ 60 mL RT A665492I Buffer PLS 15 mL RT A665492J Spin Columns DM with Collection Tubes 50 sets RT A665492K Spin Columns RM with Collection Tubes 50 sets RT A665492L Collection Tubes 100 EA RT A665492M RNase-Free Centrifuge Tubes (1.5 mL) 100 EA RTSelf prepared reagents:β- Mercaptoethanol (for newly opened or RNA extraction), 70% ethanol (prepared with water without RNase), and anhydrous ethanol.Preparation and important precautions before the experiment:To prevent RNase pollution, attention should be paid to the following aspects:1) Use plastic products and gun heads without RNase to avoid cross contamination.2) Glassware should be dry baked at a high temperature of 180 ℃ for 4 hours before use, while plastic containers can be soaked in 0.5 M NaOH for 10 minutes, thoroughly rinsed with water, and then sterilized under high pressure.3) The solution should be prepared using water without RNase.4) Operators should wear disposable masks and gloves, and change gloves frequently during the experiment.2. The sample should avoid repeated freeze-thaw cycles, otherwise it will affect the quality of DNA, RNA, and protein extraction. The sample can be stored in Buffer RL at -70 ℃ for one month.3. Please add Buffer RL before use β- Mercaptoethanol, 1 ml Buffer RL with 10 µ L β- Mercaptoethanol. join β- The buffer RL room temperature of mercaptoethanol can be stored for one month.Before the first use, anhydrous ethanol should be added to Buffer RW2, Buffer GW1, and Buffer GW2 according to the instructions on the reagent bottle label.5. Before use, please check if there is any crystallization or precipitation in the Buffer RL. If there is any crystallization or precipitation, please dissolve it again in a 56 ℃ water bath.6. All centrifugation steps are performed using a desktop centrifuge at room temperature. Operation steps:1. Material processing1a The cells cultured on the wall should be first processed into cell suspension (maximum extraction amount of 107 cells), collected cells, discarded the culture medium, and added 600 cells µ L Buffer RL (check if it has been added before use) β- Mercaptoethanol), repeatedly blow and beat to fully decompose.Attention: It is necessary to discard the culture medium completely, otherwise it will affect the lysis and subsequent nucleic acid purification steps.1b Take no more than 30 mg of animal tissue, grind it into fine powder with liquid nitrogen, and add 600 µ Buffer RL (check if it has been added before use) β- Mercaptoethanol, or directly add 600 µ L Buffer RL (check if it has been added before use) β- Mercaptoethanol, homogenization treatment.Attention: The homogenate should be sufficient, otherwise it will affect RNA production.2. Centrifuge the solution obtained in the previous step at 12000 rpm (~13400 × g) for 3-5 minutes. Carefully add the supernatant to the spin columns DM that have been loaded into the collection tube. Centrifuge at 12000 rpm for 30-60 seconds and collect the filtrate. Place the adsorption column DM in a new 2 ml collection tube at room temperature or 4 ℃ for DNA extraction. Attention: Ensure that there is no liquid residue on the adsorption column, and if necessary, repeat centrifugation until all liquids pass through the membrane of the adsorption column. Total RNA extraction3. Add 1 volume of 70% ethanol (prepared without RNase water) to the filtrate obtained in step 2, and mix well.4. Add all the solution obtained in the previous step to the spin columns RM that have been loaded into the collection tube. If the solution cannot be added completely at once, it can be transferred in stages. Centrifuge at 12000 rpm for 20 seconds and retain the liquid in the collection tube for protein extraction.5. Place the adsorption column RM into a new 2ml collection tube and add 700 to the adsorption column RM µ L Buffer RW1, centrifuge at 12000 rpm for 20 seconds, discard the waste liquid in the collection tube, and place the adsorption column RM into the recovery manifold.6. Add 500 to the adsorption column RM µ Buffer RW2 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 20 seconds, discard the waste liquid in the collection tube, and place the adsorption column RM back into the 2 ml collection tube.7. Repeat step 6.Centrifuge at 8.12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry. Attention: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).9. Place the adsorption column RM in a new 1.5 ml centrifuge tube without RNase, and add 30-50 to the middle of the adsorption column RM µ Place RNase Free Water at room temperature for 2-5 minutes, centrifuge at 12000 rpm for 1 minute, collect RNA solution, and store RNA at -70 ℃ to prevent degradation.Attention:1) The volume of RNase Free Water should not be less than 30 µ l. Small volume affects the recovery rate.2) If you want to increase RNA production, you can use 30-50 µ Repeat step 9 for the new RNase Free Water.3) If you want to increase the RNA concentration, you can add the obtained solution back to the adsorption column and repeat step 9.Genomic DNA extraction10. Add 500 to the adsorption column DM µ Buffer GW1 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 20 seconds, discard the waste liquid in the collection tube, and place the adsorption column DM into the recovery tube.11. Add 500 to the adsorption column DM µ Buffer GW2 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 2 minutes, discard the waste liquid in the collection tube, and place the adsorption column DM into the recovery tube. Attention: To further improve DNA purity, repeat step 11.Centrifuge at 12.12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column DM at room temperature for a few minutes to thoroughly dry the ethanol in the column. Attention: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).13. Place the adsorption column DM in a new centrifuge tube and add 100 to the middle of the adsorption column DM by suspending it in the air µ L Buffer GE, leave at room temperature for 2-5 minutes, centrifuge at 12000 rpm for 2 minutes, collect DNA solution, and store DNA at -20 ℃.Attention:1) The volume of Buffer GE should not be less than 100 µ l. Small volume affects the recovery rate.2) If we want to increase DNA production, we will µ Add a new Buffer GE to the adsorption column and repeat step 13; If you want to increase the DNA concentration, you can add the DNA eluent obtained in step 13 back onto the adsorption column and repeat step 13.Protein extraction14. Add 1 volume of Buffer PZ to the RNA extraction effluent (i.e. the solution obtained in step 4), mix well, and let it stand at room temperature for 10-30 minutes.Centrifuge at 15.12000 rpm for 10 minutes and discard the supernatant.16. Add 500 µ Centrifuge at 12000 rpm for 1 minute with 70% ethanol, and try to absorb the supernatant as much as possible.17. Place the centrifuge tube at room temperature for a few minutes to dry the precipitate.Attention: The purpose of this step is to remove residual ethanol. Excessive drying can make protein precipitation difficult to dissolve, and incomplete drying of residual ethanol can affect protein loading.18. Add 100 µ L Buffer PLS to obtain protein solution.Attention:1) The protein samples obtained by dissolving with Buffer PLS are suitable for SDS-PAGE and Western Blot detection, but not for Bradford method for protein quantification. If Bradford method is needed for protein quantification, 5% SDS can be used to dissolve the protein, or suitable protein dissolution buffer can be selected based on downstream experiments.2) The amount of dissolved protein buffer added is determined based on the initial sample size and specific downstream test requirements.3) The dissolved protein can be stored at -20 ℃ for several months and at 2-8 ℃ for several days.If protein samples require SDS-PAGE electrophoresis, the following operations can be performed:19. Add protein loading buffer to the protein sample, denature at 95 ℃ for 5-10 minutes, and cool the sample to room temperature. Centrifuge at 20.12000 rpm for 1 minute, extract the supernatant for downstream SDS-PAGE or Western blot tests... Read More | B669951 Component 50T Storage B669951A Buffer ATL 15 mL RT B669951B Buffer AL 15 mL RT B669951C Buffer AW1 (concentrate) 13 mL RT B669951D Buffer AW2 (concentrate) 15 mL RT B669951E Buffer EB 15 mL RT B669951F Proteinase K 1.25 mL RT B669951G Spin Columns DM with Collection Tubes 50 sets B669951 Component 50T Storage B669951A Buffer ATL 15 mL RT B669951B Buffer AL 15 mL RT B669951C Buffer AW1 (concentrate) 13 mL RT B669951D Buffer AW2 (concentrate) 15 mL RT B669951E Buffer EB 15 mL RT B669951F Proteinase K 1.25 mL RT B669951G Spin Columns DM with Collection Tubes 50 sets RTProductsThis kit is suitable for extracting high purity total DNA from Gram-negative and Gram-positive bacteria. 106-108 cells can be processed at a time, and up to 20 µg of total DNA can be obtained within one hour without the need for toxic solvents such as phenol or chloroform, and without the need for ethanol precipitation. The optimized buffer system enables the DNA in the lysate to be efficiently and specifically bound to the silica matrix centrifugal adsorption column, while other contaminants can flow through the membrane, and the inhibitors of PCR and other enzymatic reactions can be effectively removed through a two-step washing step, and finally washed off with low-salt buffer or water, so that high-purity DNA can be obtained.The purified DNA can be used for downstream experiments such as digestion, PCR, Real-Time PCR, library construction, Southern Blot and molecular labeling, molecular labeling and other downstream experiments. Self-contained reagents: anhydrous ethanol; Enzymatic Lysis Buffer is required for extraction of Gram-positive bacteria.Enzymatic Lysis Buffer was prepared by 20 mM Tris, pH 8.0; 2 mM Na2-EDTA, pH 8.0; and 1.2% Triton X-100. 121°C sterilization for 20 minutes, and the appropriate amount of Lysozyme was added at a final concentration of 20 mg/ml. Pre-experiment Preparation and Important Notes1. Add 1.25ml Proteinase K Storage Buffer to Proteinase K to dissolve it and store it at -20℃. Do not leave the prepared Proteinase K at room temperature for a long time, and avoid repeated freezing and thawing to avoid affecting its activity.2. Repeated freezing and thawing of the sample should be avoided, as this may result in smaller DNA fragments and a decrease in the amount of extracted DNA.3. If extracting genomes from bacterial cultures with high accumulation of secondary metabolites or thick cell walls, it is recommended that samples be collected early in the logarithmic phase.4. Anhydrous ethanol should be added to Buffer GW1 and Buffer GW2 according to the instructions on the label of the reagent bottle before first use.5. Before use, please check Buffer GTL and Buffer GL for crystallization or precipitation. If crystallization or precipitation occurs, please re-dissolve Buffer GL and Buffer GTL in a 56℃ water bath.6. If the downstream experiments are sensitive to RNA contamination, 4µl of DNase-Free RNase A (100mg/ml) can be added before adding Buffer GL. RNase A is not provided in this kit.If the extracted samples are Gram-positive bacteria, customers need to prepare their own Enzymatic Lysis Buffer to treat the bacteria, which requires the use of Lysozyme (lysozyme) at a concentration of 20 mg/ml, which is not provided in this kit.Procedurei Extraction of genomic DNA from Gram-negative bacteria1. Take 1-5 ml of bacterial culture (106-108 cells, maximum 2×109 cells) and put it into a centrifuge tube (provided), centrifuge it at 12,000 rpm (~13,400×g) for 1 minute, and aspirate the supernatant as much as possible.2. Add 180 µl Buffer GTL to the precipitate and shake to resuspend the bacteria.3. Add 20 µl of Proteinase K, vortex and mix well, incubate at 56°C until the solution becomes clear, and invert or shake the centrifuge tube at intervals during the incubation to disperse the sample.Note: If RNA removal is required, add 4 µl of RNase A solution at a concentration of 100 mg/ml after the above steps are completed, shake to mix, and leave for 5-10 minutes at room temperature.4. Add 200µl Buffer GL and mix well with vortexing and shaking. Add 200µl of anhydrous ethanol and mix well with vortexing and shaking.Centrifuge briefly so that the solution on the walls of the tube collects at the bottom.Note: 1) If multiple samples are manipulated together, Buffer GL and anhydrous ethanol can be mixed in equal proportions and then added together, shaking to mix.2) The addition of Buffer GL and anhydrous ethanol may produce a white precipitate that will not affect subsequent experiments.5. Add all of the solution obtained in step 4 (including the precipitate formed) to the Spin Columns DM in the collection tube, or if the solution cannot be added all at once, transfer it several times. centrifuge at 12,000 rpm for 1 minute, discard the waste solution, and return the column to the collection tube.6. Add 500 µl of Buffer GW1 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and return the adsorption column to the collection tube.7. Add 500 µl of Buffer GW2 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorption column back into the collection tube.Note: Step 7 can be repeated if further DNA purity is required.8. Centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Leave the adsorbent column at room temperature for several minutes to dry thoroughly. Note: The purpose of this step is to remove residual ethanol from the adsorbent column; ethanol residue can interfere with subsequent enzymatic reactions (digestion, PCR, etc.).9. Place the adsorption column in a new centrifuge tube, add 50-200 µl Buffer GE to the middle part of the adsorption column overhanging the center of the adsorption column, leave it at room temperature for 2-5 minutes, centrifuge it at 12,000 rpm for 1 minute, collect the DNA solution, and store the DNA at -20 ℃. note: 1) If the downstream experiments are sensitive to the pH or EDTA, the elution can be done with sterilized water. The pH of the elution solution has a great influence on the elution efficiency. If water is used as the elution solution it should be ensured that its pH is 7.0-8.5 (the pH of water can be adjusted to this range with NaOH), and the elution efficiency is not high when the pH is lower than 7.0.2) Incubation at room temperature for 5 minutes prior to centrifugation increases yield.3) Re-elution with an additional 50-200 µl Buffer GE or sterilized water can increase the yield.4) If the final concentration of DNA is to be increased, the DNA eluate obtained in step 9 can be re-spiked onto the adsorbent membrane and step 9 repeated; if the elution volume is less than 200 µl, the final concentration of DNA can be increased, but the total yield may be reduced. If the amount of DNA is less than 1 µg, elution with 50 µl Buffer GE or sterilized water is recommended.(5) DNA stored in water will be affected by acidic hydrolysis. For long-term storage, it is recommended to elute with Buffer GE and store at -20℃.i. Extraction of genomic DNA from Gram-positive bacteria1. Take 1-5 ml of bacterial culture (106-108 cells, maximum 2×109 cells) and put it into a centrifuge tube (provided), centrifuge it at 12,000 rpm (~13,400×g) for 1 minute, and aspirate the supernatant as much as possible.2. Add 180µl Enzymatic Lysis Buffer (self-provided) to resuspend the bacteria.Enzymatic Lysis Buffer is prepared as described in the Self-Prepared Reagents section in the front of the manual.3. Incubate at 37°C for 30 minutes.4. Add 20µl Proteinase K and mix well. Add 200µl of Buffer GL and mix well with vortexing and shaking.Note: Do not add Proteinase K directly to Buffer GL.Incubate at 5.56°C for 30 minutes.Note: 1) If desired, incubation at 95°C for 15 minutes will inactivate the pathogen, but 95°C incubation will cause some DNA degradation.(2) If RNA removal is required, add 4µl of RNase A solution at a concentration of 100mg/ml after the above steps are completed, shake and mix well, and leave for 5-10 minutes at room temperature.6. Add 200µl of anhydrous ethanol and mix well with vortex shaking.Note: The addition of anhydrous ethanol may produce a white precipitate that will not affect subsequent experiments.7. Add all of the solution obtained in step 6 (including the precipitate formed) to the Spin Columns DM that have been loaded into the collection tube, and if the solution cannot be added all at once, it can be transferred in several times. centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid from the collection tube, and put the column back into the collection tube.8. Add 500 µl of Buffer GW1 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorption column back into the collection tube.9. Add 500 µl Buffer GW2 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge the column at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the column back into the collection tube.Note: Step 9 can be repeated if further DNA purity is required.10. Centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Leave the adsorption column at room temperature for several minutes to dry thoroughly.Note: The purpose of this step is to remove residual ethanol from the adsorption column; ethanol residue can interfere with subsequent enzymatic reactions (digestion, PCR, etc.).11. Place the adsorption column in a new centrifuge tube (self-provided), add 50-200 µl of Buffer GE to the center of the adsorption column overhanging the center of the adsorption column, let it stand at room temperature for 2-5 minutes, centrifuge at 12,000 rpm for 1 minute, collect the DNA solution, and store the DNA at -20℃.Note: 1) If the downstream experiment is sensitive to pH or EDTA, you can use sterilized water for elution. The pH of the eluent has a great influence on the elution efficiency, if water is used as the eluent should ensure that its pH is 7.0-8.5 (you can use NaOH to adjust the pH of the water to this range), and the elution efficiency is not high when the pH is lower than 7.0.2) Incubation at room temperature for 5 minutes prior to centrifugation increases yield.3) Re-elution with an additional 50-200 µl Buffer GE or sterilized water can increase the yield.4) If the final concentration of DNA is to be increased, the DNA eluate obtained in step 11 can be re-spiked onto the adsorbent membrane and step 11 repeated; if the elution volume is less than 200 µl, the final concentration of DNA can be increased, but the total yield may be reduced. If the amount of DNA is less than 1 µg, elution with 50 µl Buffer GE or sterilized water is recommended.(5) DNA stored in water will be affected by acidic hydrolysis. For long-term storage, it is recommended to elute with Buffer GE and store at -20℃... Read More | DescriptionCholesteryl ester transfer protein (CETP) is present in normal human plasma and transfers neutral lipids from high density lipoproteins (HDL) to very low density lipoprotein (VLDL) and low density lipoprotein (LDL). CETP plays an important role in lipoprotein metabolism and influences theDescriptionCholesteryl ester transfer protein (CETP) is present in normal human plasma and transfers neutral lipids from high density lipoproteins (HDL) to very low density lipoprotein (VLDL) and low density lipoprotein (LDL). CETP plays an important role in lipoprotein metabolism and influences the reverse cholesterol transport pathway.Preparation instructionsSuitable for high-throughput screening (HTS), mechanism of action (MOA) studies, and structure-activity relationship (SAR) work in CETP sources.PrincipleThe CETP RP Activity Assay uses a proprietary substrate that enables the detection of CETP-mediated neutral lipid mass transfer. The method is useful for measuring CETP activity in recombinant protein (RP) or purified CETP samples and has a high D... Read More | Inquire |