| Description | Annexins are a family of calcium-dependent phospholipid-binding proteins that preferentially bind phosphatidylserine (PS). Under normal physiologic conditions, PS is predominantly located in the inner leaflet of the plasma membrane. Upon initiation of apoptosis, PS loses its asymmetric distribution Annexins are a family of calcium-dependent phospholipid-binding proteins that preferentially bind phosphatidylserine (PS). Under normal physiologic conditions, PS is predominantly located in the inner leaflet of the plasma membrane. Upon initiation of apoptosis, PS loses its asymmetric distribution across the phospholipid bilayer and is translocated to the extracellular membrane leaflet marking cells as targets of phagocytosis. Once on the outer surface of the membrane, PS can be detected by fluorescently labeled Annexin V in a calcium-dependent manner. In early-stage apoptosis, the plasma membrane excludes viability dyes such as propidium iodide (PI), 7-AAD. These cells will stain with Annexin V but not a viability dye, thus distinguishing cells in early apoptosis. However, in late stage apoptosis, the cell membrane loses integrity thereby allowing Annexin V to also access PS in the interior of the cell. A viability dye can be used to resolve these late-stage apoptotic and necrotic cells (Annexin V, viability dye-positive) from the early-stage apoptotic cells (Annexin V positive, viability dye-negative). This kit is suitable for the identification and enumeration of dead cells, such as apoptotic or necrotic cells, by flow cytometry. A1456539Components20T50T100TStorageQuantity Per TestA1456539A10× Annexin V Binding Buffer5 mL10 mL20 mL2-8℃200 µL per 0.5-1.0x10⁵ cellsA1456539BAnnexin V -AF64740 µL100 µL200 µL2-8℃. Store in the dark.2 µL per 0.5-1.0x10⁵ cellsA1456539C7-AAD Staining Solution 40 µL 100 µL200 µL2-8℃. Store in the dark.2µL per 0.5-1.0x10⁵ cellsNote: The recommended number of cells to stain per test is 0.5-1.0x10⁵ cells. Precautions 1. 1. Please try to avoid light when using to slow down the quenching of fluorescence. 2. 7-AAD Solution is toxigenic and mutagenic; handle with care. 3. Due to the calcium dependence of the Annexin V:PS interaction, it is critical to avoid buffers containing EDTA or other calcium chelators during Annexin V experiments. Instruction for use 1. Dilute 10x Binding Buffer to 1x using distilled water (1 mL 10x Binding Buffer + 9 mL ddH2O). 2. Wash cells twice with cold PBS and then resuspend the desired amount of cells in Annexin V Binding Buffer at a concentration of 1.0-5.0 x 106 cells/mL. 3. Add 2 µl of AF647 Annexin V and 2 µl 7-AAD to 100 µL of the cell suspension. 4. Add 100 µL of 1x Binding Buffer to each assay. Gently vortex the cells and incubate for 10 min at RT (25°C) in the dark. 5. Analyze by flow cytometry within 1 hr... Read More | Inquire | G665573 Component 10 T Storage G665573A Buffer P1 30 mL RT G665573B Buffer P2 30 mL RT G665573C Buffer E3 30 mL RT G665573D Buffer PS 15 mL RT G665573E Buffer PW (concentrate) 10 mL RT G665573F Endo-Free Buffer EB 30 mL RT G665573G RNase A (10 mg/mL) 600 碌L RT G665573H Endo-Remover FX 10 EA G665573 Component 10 T Storage G665573A Buffer P1 30 mL RT G665573B Buffer P2 30 mL RT G665573C Buffer E3 30 mL RT G665573D Buffer PS 15 mL RT G665573E Buffer PW (concentrate) 10 mL RT G665573F Endo-Free Buffer EB 30 mL RT G665573G RNase A (10 mg/mL) 600 碌L RT G665573H Endo-Remover FX 10 EA RT G665573I Plungers 10 EA RT G665573J Spin Columns DX with Collection Tubes 10 EA RT G665573K Centrifuge Tubes (15 mL) 10 EA RTProduct IntroductionThis kit is specially designed for the efficient and rapid extraction of plasmids from 15-50 ml of bacterial fluids. On the basis of cell lysis by alkaline lysis method, it adopts unique silicon matrix membrane adsorption technology to bind plasmid DNA efficiently and exclusively, and each adsorption column can adsorb up to 250 µg of plasmid DNA; at the same time, it adopts a special buffer system and endotoxin removal filter to effectively remove endotoxin, genomic DNA, RNA, protein and other impurities. The plasmids obtained from this kit are of high purity and stable quality, and can be used for cell transfection, as well as DNA sequencing, PCR, in vitro transcription, endonuclease digestion and other experiments.Self-contained reagents: anhydrous ethanol, isopropanol.Pre-experiment Preparation and Important Notes1. All components are stable for 1 year in a dry, room temperature (15-30°C) environment, and longer by placing the adsorption columns at 2-8°C. Buffer P1 with RNase A is stable for 6 months at 2-8°C.2. Before the first use, add all of the RNase A solution to Buffer P1, mix well, and store at 2-8°C. Before use, it needs to be left at room temperature for a period of time, return to room temperature and then use.3. Anhydrous ethanol should be added to Buffer PW before the first use according to the instructions on the reagent bottle label.4. Please check Buffer P2 and Buffer E3 for crystallization or precipitation before use. If there is any crystallization or precipitation, the clarification can be restored by taking a water bath at 37℃ for a few minutes.5. Be careful not to touch Buffer P2 and Buffer E3 directly, and tighten the lid immediately after use.6. The amount and purity of extracted plasmid is related to the concentration of bacterial culture, strain type, plasmid size, plasmid copy number and other factors.7. The adsorption columns treated with Buffer PS should be used immediately to avoid leaving them for too long.Operation steps1.Take 15-50 ml of fresh bacterial solution from the overnight culture, add it to a centrifuge tube (self-prepared) and centrifuge at 5000 × g for 10 minutes to collect the bacteria, and aspirate all the supernatant as much as possible.2.Add 2.5 ml of Buffer P1 to the centrifuge tube in which the bacterial precipitate has been left (please check that RNase A has been added first) and suspend the bacterial precipitate by mixing thoroughly using a pipette or vortex shaker. Note: If the bacterial mass is not thoroughly mixed, it will affect the lysis effect and make the extraction amount and purity low.3.Add 2.5 ml of Buffer P2 to the centrifuge tube, mix gently up and down 8-10 times to fully lyse the organisms, and leave at room temperature for 3-5 minutes. At this point the solution should become clear and viscous. Note: Mix gently, do not shake vigorously, so as not to interrupt the genomic DNA and cause genomic DNA fragments to be mixed in the extracted plasmid. If the solution does not become clear, it suggests that the amount of bacteria may be too large and the lysis is not complete, and the amount of bacteria should be reduced.4.Add 2.5 ml of Buffer E3 to the centrifuge tube and mix immediately by turning up and down 8-10 times, at which time a white flocculent precipitate appears. Note: Buffer E3 should be mixed immediately after addition to avoid localized precipitation.5.Install the cap of the filter (Endo-Remover FX), transfer the solution obtained in step 4 to the filter, wait until the white flocculent precipitate floats on the upper layer of the solution, remove the cap of the filter, align the filter with a clean 15 ml centrifuge tube (supplied), and slowly push the handle (Plungers) to filter, so that as much as possible of the solution passes through, and the filtrate is collected in the centrifuge tube.6.Add 1/3 solution volume of isopropanol to the filtrate and mix upside down.7.Column Equilibrium: Add 1ml Buffer PS to the adsorption column (Spin Columns DX) that has been loaded into a 15ml centrifuge tube, centrifuge for 2 minutes at 2500 x g. Pour off the waste liquid from the centrifuge tube and put the adsorption column back into the centrifuge tube.8.The mixture of filtrate and isopropanol from step 6 was transferred to the equilibrated adsorption column (which had been loaded into a collection tube).9.Centrifuge at 2500 x g for 1 minute, pour off the waste solution in the collection tube and put the adsorption column back into the collection tube. Note: The maximum volume of the adsorption column is 4 ml, so the solution obtained in step 8 is passed through the column in 2 times.10.Add 2 ml of Buffer PW to the adsorption column (please check that anhydrous ethanol has been added first), centrifuge at 2500 × g for 1 min, and pour off the waste liquid in the collection tube.11.Repeat step 10.12.The adsorbent column was put back into the collection tube and centrifuged at 2500 × g for 2 min, the waste liquid was poured off, and the column was left to dry at room temperature for 5 min.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can interfere with subsequent enzymatic reactions (digestion, PCR, etc.)13. Place the adsorption column in a new 15 ml centrifuge tube, add 0.5-1 ml Endo-Free Buffer EB to the middle of the adsorbent membrane, leave it at room temperature for 2-5 minutes, centrifuge it at 2500 × g for 2 minutes, and collect the plasmid solution into the centrifuge tube. -20°C to store the plasmid.Note: 1) In order to increase the recovery efficiency of the plasmid, the obtained solution can be reintroduced into the adsorption column, left at room temperature for 2-5 minutes, centrifuged at 2500 x g for 2 minutes, and the plasmid solution can be collected into a centrifuge tube.2) When the plasmid copy number is low or >10kb, Endo-Free Buffer EB can increase the extraction efficiency by preheating at 65-70°C in a water bath... Read More | Inquire | Products contentN665978Component384 TStorageN665978AIndex N502-N522 Primers for Illumina 16×24 µL-20℃. Avoid freeze/thaw cycle.N665978BIndex N701-N729 Primers for Illumina24×16 µL-20℃. Avoid freeze/thaw cycle. Products IntroductionThis kit is a companion to the Products contentN665978Component384 TStorageN665978AIndex N502-N522 Primers for Illumina 16×24 µL-20℃. Avoid freeze/thaw cycle.N665978BIndex N701-N729 Primers for Illumina24×16 µL-20℃. Avoid freeze/thaw cycle. Products IntroductionThis kit is a companion to the transposase-based rapid DNA library construction kit, designed for Illumina platform library construction. It contains 16 N5 primers and 24 N7 primers, which can be used to prepare 384 different bipartite Index libraries. All reagents provided in the kit have been subjected to stringent quality control and functional validation to maximize the stability and reproducibility of library construction. The libraries can be used for sequencing on Illumina platforms such as HiSeq X-10/4000/2500/2000 and MiSeq.Provide your own instruments, reagents and consumables1. Magnetic frame: DynaMagTM-2 is recommended.2. DNA purification and recovery kit: It is recommended to use Kangwei DNA purification and recovery kit by magnetic bead method.3. DNA building kit: It is recommended to use the Kangwei Century transposase method second-generation sequencing rapid DNA building kit.4. Anhydrous ethanol.5. Reaction tubes: It is recommended to use low adsorption PCR tubes with 1.5 ml centrifuge tubes; Tip: It is recommended to use a high quality filter tip to prevent contamination of kits and library samples. Pre-experiment Preparation and Important NotesPlease centrifuge briefly before opening the cap so that the liquid collects at the bottom of the tube to avoid cross-contamination between different primers.procedure For the use of the CombiVision Second Generation Sequencing Multisample Primer Kit, please follow the CombiVision Second Generation Sequencing Rapid DNA Library Kit protocol. Index N502-N522 Primers for Illumina Index N701-N729 Primers for Illumina... Read More |