| Description | The Cell Cycle and Apoptosis Kit (Cell Cycle and Apoptosis Kit) is a test kit that uses the classic propidium iodide (PI) staining method to analyze the cell cycle and apoptosis. Propidium iodide is a fluorescent dye for double-stranded DNA. When propidium iodide binds to double-stranded DNA, The Cell Cycle and Apoptosis Kit (Cell Cycle and Apoptosis Kit) is a test kit that uses the classic propidium iodide (PI) staining method to analyze the cell cycle and apoptosis. Propidium iodide is a fluorescent dye for double-stranded DNA. When propidium iodide binds to double-stranded DNA, it can produce fluorescence, and the fluorescence intensity is proportional to the content of double-stranded DNA. After the DNA in the cells is stained with propidium iodide, the DNA content of the cells can be measured using a flow cytometer, and then based on the distribution of DNA content, the cell cycle and apoptosis can be analyzed. After staining with propidium iodide, if the fluorescence intensity of G0/G1 phase cells is 1, then the theoretical fluorescence intensity of G2/M phase cells containing double genomic DNA is 2, and the fluorescence intensity of S phase cells undergoing DNA replication is between 1 and 2. Apoptotic cells, due to the condensation of the cell nucleus and the fragmentation of DNA (DNA fragmentation), cause some genomic DNA fragments to be lost during staining, so the iodine staining of apoptotic cells presents a significantly weak color, that is, the fluorescence intensity is less than 1, and a so-called sub-G1 peak appears on the fluorescence graph of flow cytometry, which is the peak of apoptotic cells. When cells undergo apoptosis, due to the concentration of cytoplasm and chromatin, apoptotic bodies are produced, causing changes in the light scattering properties of the cells. In the early stage of cell apoptosis, the ability of the cell to forward-angle light scattering significantly decreases, while the ability of lateral light scattering increases or remains unchanged. In the late stage of cell apoptosis, the signals of forward and lateral light scattering both decrease, so the changes in cell light scattering can be measured using a flow cytometer to observe the apoptosis situation. This kit is usually applied to the detection of the cell cycle and apoptosis of cultured adherent or suspended cells. If used for the cell cycle and apoptosis detection of cells from tissues, the tissue must be digested into a single-cell state before detection can be performed. P1373478Component20 T50 T100 TStorageQuantity Per TestP1373478ADyeing buffer solution10 mL25 mL50 mL-20℃.500 µL per 1 × 10⁶ cells.P1373478BPropidium Iodide staining solution (20X)100 µL250 µL500 µL-20℃.Store in the dark.5 µL per 1 × 10⁶ cells.P1373478CRNase A (50X)0.2 mL0.5 mL1 mL-20℃.10 µL per 1 × 10⁶ cells.Note: The recommended number of cells to stain per test is 1 × 10⁶ cellsInstructions for use1.Collect cells and wash twice with ice-cold PBS; resuspend in ice-cold PBS at a density of 0.1–1.0 × 10⁷ cells/mL.2.In the cell suspension, anhydrous ethanol was added dropwise while shaking until the final ethanol concentration reached 70%.3.Mix gently and fix overnight at 4 °C.4.Wash cells twice with ice-cold PBS, then resuspend in dyeing buffer solution of 2 × 10⁶ cells/mL.5.Add 5 µL of Propidium iodide and 10 µL RNase A to 500 µL of the cell suspension.6.Resuspend cells gently and thoroughly, then incubate at room temperature for 30 min in the dark.7.Analyze samples by flow cytometry.Note: Please bring your own PBS and absolute ethanol.Precautions 1. Fluorescent dyes all have the problem of quenching. Please try to avoid light during storage and use to slow down fluorescence quenching. 2. Iodophor is irritating to the human body. Please take appropriate protective measures. 3. Iodophor is a known mutagen, so this solution needs to be treated with activated carbon before being discarded. 4. When fixing cells with 70% ethanol, make sure it is thorough; otherwise, uneven staining will result in unclear or inaccurate results. It is recommended to fix the cells overnight at -4℃ with 70% ethanol. 5. After cell fixation, ensure that the cells are in a single-cell suspension; cell adhesion may affect our results. 6. For your safety and health, please wear laboratory coats and disposable gloves during operation. 7. This product is only for scientific research and cannot be used for clinical diagnosis or treatment, nor for food or medicine. It must not be stored in ordinary residences. 8. For your safety and health, please wear laboratory coats and disposable gloves during operation... Read More | Cell proliferation detection is a basic experimental method to evaluate the health of cells, genotoxicity and the effect of antitumor drugs. The most accurate method to detect cell proliferation is the BrdU method. Edu detection kit is a revolutionary breakthrough of BrdU method. Edu (5-Cell proliferation detection is a basic experimental method to evaluate the health of cells, genotoxicity and the effect of antitumor drugs. The most accurate method to detect cell proliferation is the BrdU method. Edu detection kit is a revolutionary breakthrough of BrdU method. Edu (5-ethynyl-2 '- deoxyuridine) is a pyrimidine analog that integrates into the DNA duplex during DNA synthesis. Edu detection is based on the "click" reaction. A copper catalyzed azide reacts covalently with alkynes to form covalent bonds. In this kit, edu contains alkynes, Aladdin ® 488 / 555/594/647a azide dyes contain azide compounds. The edu labeling proliferation of click method is rapid and effective, and easy to use. BrdU method requires DNA denaturation (such as acid denaturation, thermal denaturation or digestion with DNase) to expose BrdU, so as to facilitate BrdU antibody binding; The edu method only needs paraformaldehyde fixation and Triton X-100 penetration to make the detection reagent enter the cells, and only a small amount of azide dye is needed to label the integrated edu very effectively. This kit contains all components required for edu method detection, and can be used for proliferation detection of cultured cells in vitro.Component:Product parameters:555/565 nm;Instruction: Experimental materials (self provided). 10 mM PBS, pH 7.2-7.6. 4% paraformaldehyde fixing solution (in PBS)Propensive reagent (0.5% Triton X -100 in PBS). 2 mg/mL glycine solution (in ddH2O). 3% BSA in PBS, pH 7.2-7.6. 1% BSA in PBS, pH 7.2-7.6. ddH2O. 96/24/12/6 well culture plate or dishFluorescence microscopy detection method1. Cell cultureTake logarithmic growth stage cells and inoculate them into a 96 well plate with 4 × 103-1 × 105 cells per well (the number and density of cells can be adjusted according to cell size, growth rate, and specific requirements of experimental treatment), and culture until normal growth stage.2. Drug treatmentPerform various drug treatments according to experimental needs.3. EdU marking(1) Dilute EdU solution (component A) in a certain proportion with complete cell culture medium to an appropriate concentration, then add it to the cells and mix well; Set up a negative control group without EdU treatment.Note: The labeling concentration of EdU needs to be adjusted according to cell type, and it is recommended to explore with an initial concentration of 10 µ M. In the pre experiment, it is recommended to set an EdU concentration gradient, which can be referred to in Tables 2 and 3.(2) Incubate in a cell culture incubator for 2 hours.Note: The optimal incubation time is related to the cell cycle. Most tumor cell lines can use a 2-hour incubation time, as shown in Appendix 2. The concentration of EdU is related to the incubation time, and high concentrations, such as 10-50, should be used for short-term incubation (<2 hours) µ M; Long term incubation (>24 hours) should use low concentrations, such as 1-10 µ M; You can also refer to Appendix 3.4. Cell fixation and permeation promotionNote: For experiments that require cell surface antigen labeling, it can be considered to wash the cells twice with a 3% BSA washing solution after completing EdU incubation, before cell fixation and permeation promotion.(1) After incubation, remove the culture medium. Wash cells twice with 1X PBS for 5 minutes each time to remove EdU residues that have not been incorporated into DNA. Cells with weak adhesion can reduce cleaning intensity. Join 50 µ After incubating at room temperature for 20 minutes with 4% paraformaldehyde fixative, remove the fixative.(2) Add 50 to each hole µ L 2 mg/mL glycine solution, incubate at room temperature for 5 minutes, and neutralize the remaining fixed solution.(3) At a rate of 100 per hole µ Wash cells twice with 3% BSA.(4) Remove the washing solution and add 100 µ L 0.5% Triton X -100, incubate at room temperature for 10 minutes.5. EdU detectionNote: Each sample in this reference step uses 100 µ The working fluid of L can be adjusted by users according to their own sample situation.(1) Prepare 1 x Click iT EdU reaction buffer (component C): Dilute component C 10 times with ddH2O.(2) Configure 5 x Click iT EdU buffer additives (component E): add 300 µ Mix L of ddH2O into a 30 mg E component tube (final concentration of 100 mg/mL) until completely dissolved. After use, the remaining storage solution is stored at -20 ℃ and can be stored for one year. Once the solution turns brown, it indicates that the active ingredients have degraded and cannot be reused.Note: Different specifications of component E are dissolved in ddH2O according to this ratio, and prepared into a 5 x storage solution for future use.(3) Prepare 1 x Click iT EdU buffer additive: Dilute 5 x Click iT EdU buffer additive with ddH2O to 1 x, and the solution should be prepared and used immediately.(4) Prepare Click it working solution according to Table 1.Table 1 Click it working fluidReaction componentsTaking the sample size of 10 holes as an example1×Click-iT EdU Reaction buffer855 µLCuSO4 (Component D)40 µLYF® 488/555/594/647A Azide(Component B)5 µL1×Click-iT EdU Buffer additives100 µLTotal volume1 mL(5) Remove penetration enhancer, 100 per well µ Wash twice with 3% BSA washing solution of L.(6) Add 100 to each hole µ L Click iT working solution, evenly covering cells.(7) Incubate at room temperature in dark for 30 minutes.(8) Remove Click-iT working fluid and add 100 µ After washing cells twice with 3% BSA, remove the washing solution and add 100 µ L PBS keeps cells moist. If there are no other special requirements, photography analysis can be carried out.6. DNA re staining (optional)(1) Using 100 µ Wash the cells once with PBS and remove the washing solution.(2) Dilute Hoechst 33342 (component F) 2000 times with PBS.(3) Add 100 to each hole µ Incubate L 1 x Hoechst 33342 solution at room temperature in dark for 15-30 minutes.(4) Remove Hoechst 33342 solution and use 100 µ Wash cells twice with PBS.7. Imaging and analysisIt is recommended to take fluorescence microscopy photos immediately after staining is completed for observation; If conditions permit, please store in a dark and moist environment at 4 ° C for 3 days before taking photos. Flow cytometry detection method1. Cell cultureInoculate 1 × 105~3 × 106 cells per well into a 6-well plate.2. Drug treatmentPerform various drug treatments according to experimental needs.3. EdU labeled cells(1) Dilute EdU solution (component A) in a certain proportion with complete cell culture medium to an appropriate concentration, then add it to the cells and mix well; Set up a negative control group without EdU treatment.Note: The labeling concentration of EdU needs to be adjusted according to cell type, and it is recommended to explore with an initial concentration of 10 µ M. In the pre experiment, it is recommended to set an EdU concentration gradient, which can be referred to in Tables 2 and 3.(2) Incubate in a cell culture incubator for 2 hours. The time of EdU incubation of cells can be directly used as an indicator for measuring cell DNA synthesis, and the choice of time point and incubation time depend on the cell growth rate. Pulse labeled cells incubated with brief EdU can be used to study cell cycle dynamics.Note: The optimal incubation time is related to the cell cycle. Most tumor cell lines can use a 2-hour incubation time, as shown in Appendix 2. The concentration of EdU is related to the incubation time, and high concentrations such as 10-50 should be used for short-term incubation (<2 hours) µ M; Long term incubation (>24 hours) should use low concentrations, such as 1-10 µ M; You can also refer to Appendix 3.4. Cell fixation and permeation promotionNote: For experiments that require cell surface antigen labeling, it can be considered to wash cells twice with 1% BSA after completing EdU incubation, before cell fixation and permeation promotion.(1) After incubation, collect cells, add 1 mL of PBS to each tube to clean the cells, centrifuge at 1000 rpm for 5 minutes, and discard the supernatant to remove EdU residue that has not been added to DNA.(2) Add 1 mL of 4% paraformaldehyde fixative to each tube to resuspend cells.(3) Incubate at room temperature for 20 minutes, centrifuge at 1000 rpm for 5 minutes, and discard the supernatant.(4) Add 1 mL of 2 mg/mL glycine to each tube and incubate for 5 minutes. Neutralize the remaining fixed solution, centrifuge at 1000 rpm for 5 minutes, and discard the supernatant. Add 1 mL of PBS to each tube for cleaning once, centrifuge at 1000 rpm for 5 minutes, and discard the supernatant.(5) Add 1mL of 0.5% Triton X-100 osmotic enhancer to each tube and resuspend cells. Incubate at room temperature for 10 minutes.5. EdU detectionNote: For 6-well plate samples, reference can be made to 1 mL of working solution per well. Users can adjust the dosage according to their own sample situation.(1) Prepare 1 x Click iT EdU reaction buffer: Dilute component C 10 times with ddH2O.(2) Prepare 5 x Click iT EdU buffer additives (component E): Add 300 µ L ddH2O to 30 mg of component E in a test tube (final concentration 100 mg/mL), mix well until completely dissolved. After use, the remaining storage solution is stored at -20 ℃ and can be stored for one year. Once the solution turns brown, it indicates that the active ingredients have degraded and cannot be reused.Note: Different specifications of component E are dissolved in ddH2O according to this ratio to form 5 x storage solution for future use.(3) Prepare 1 x Click iT EdU buffer additive: Dilute 5 x Click iT EdU buffer additive storage solution with ddH2O to 1 x, and the solution should be prepared and used immediately.(4) Prepare Click it working solution according to Table 2.Table 2 Click it working fluidReaction componentsVolume of liquid required for a single reaction1×Click-iT EdU Reaction buffer875 µLCuSO4 (Component D)20 µLYF® 488/555/594/647A Azide(Component B)5 µL1×Click-iT EdU Buffer additives100 µLTotal volume1 mL(5) Soak at 1000 rpm for 5 minutes, discard the supernatant, remove the enhancer, add 1mL of 1% BSA washing solution to each tube and wash twice. Soak at 1000 rpm for 5 minutes, discard the supernatant.(6) Add 1 mL of Click iT working solution to each tube and mix well.(7) Incubate at room temperature in dark for 30 minutes.(8) Soak at 1000 rpm for 5 minutes, discard the staining reaction solution, add 1% BSA to each tube to wash the cells twice, centrifuge at 1000 rpm for 5 minutes, discard the supernatant, and resuspend the cells again with 1 mL of 1% BSA (the volume of resuspend cells can be adjusted according to the number of cells), and detect with a flow cytometer.Note: If other biomarker tests are required, please refer to step 4.6. Intracellular antigen labeling (optional steps)(1) Add antibody working solution and mix well.(2) Under dark conditions, incubate antibodies at appropriate temperature and time.7. Flow detection and analysis:(1) It is recommended to conduct flow cytometry testing immediately after dyeing is completed; If conditions are limited, please store in a dark place at 4 ℃ for testing, but it should not exceed 3 days.(2) It is recommended to test the number of cells up to one million levels as much as possible. If the number of cells is small, the number of cells tested can be adjusted to 100000 levels starting from the experiment. For cases where the cell yield is too low (just to the level of ten thousand), it may not be conducive to making a flow chart. Therefore, the cleaning frequency in step 5 (8) can be appropriately reduced.Matters needing attention:1. please centrifuge the product to the bottom of the tube immediately before use, and then conduct subsequent experiments. 2. fluorescent dyes have quenching problems. Please try to avoid light during experimental operation to slow down fluorescence quenching. 3. click it edu buffer additive solution should be prepared and used immediately to ensure the best results. 4. for your safety and health, please wear experimental clothes and disposable gloves.Scope of application:Cell proliferation detection (cell imaging flow universal)... Read More | G665573 Component 10 T Storage G665573A Buffer P1 30 mL RT G665573B Buffer P2 30 mL RT G665573C Buffer E3 30 mL RT G665573D Buffer PS 15 mL RT G665573E Buffer PW (concentrate) 10 mL RT G665573F Endo-Free Buffer EB 30 mL RT G665573G RNase A (10 mg/mL) 600 碌L RT G665573H Endo-Remover FX 10 EA G665573 Component 10 T Storage G665573A Buffer P1 30 mL RT G665573B Buffer P2 30 mL RT G665573C Buffer E3 30 mL RT G665573D Buffer PS 15 mL RT G665573E Buffer PW (concentrate) 10 mL RT G665573F Endo-Free Buffer EB 30 mL RT G665573G RNase A (10 mg/mL) 600 碌L RT G665573H Endo-Remover FX 10 EA RT G665573I Plungers 10 EA RT G665573J Spin Columns DX with Collection Tubes 10 EA RT G665573K Centrifuge Tubes (15 mL) 10 EA RTProduct IntroductionThis kit is specially designed for the efficient and rapid extraction of plasmids from 15-50 ml of bacterial fluids. On the basis of cell lysis by alkaline lysis method, it adopts unique silicon matrix membrane adsorption technology to bind plasmid DNA efficiently and exclusively, and each adsorption column can adsorb up to 250 µg of plasmid DNA; at the same time, it adopts a special buffer system and endotoxin removal filter to effectively remove endotoxin, genomic DNA, RNA, protein and other impurities. The plasmids obtained from this kit are of high purity and stable quality, and can be used for cell transfection, as well as DNA sequencing, PCR, in vitro transcription, endonuclease digestion and other experiments.Self-contained reagents: anhydrous ethanol, isopropanol.Pre-experiment Preparation and Important Notes1. All components are stable for 1 year in a dry, room temperature (15-30°C) environment, and longer by placing the adsorption columns at 2-8°C. Buffer P1 with RNase A is stable for 6 months at 2-8°C.2. Before the first use, add all of the RNase A solution to Buffer P1, mix well, and store at 2-8°C. Before use, it needs to be left at room temperature for a period of time, return to room temperature and then use.3. Anhydrous ethanol should be added to Buffer PW before the first use according to the instructions on the reagent bottle label.4. Please check Buffer P2 and Buffer E3 for crystallization or precipitation before use. If there is any crystallization or precipitation, the clarification can be restored by taking a water bath at 37℃ for a few minutes.5. Be careful not to touch Buffer P2 and Buffer E3 directly, and tighten the lid immediately after use.6. The amount and purity of extracted plasmid is related to the concentration of bacterial culture, strain type, plasmid size, plasmid copy number and other factors.7. The adsorption columns treated with Buffer PS should be used immediately to avoid leaving them for too long.Operation steps1.Take 15-50 ml of fresh bacterial solution from the overnight culture, add it to a centrifuge tube (self-prepared) and centrifuge at 5000 × g for 10 minutes to collect the bacteria, and aspirate all the supernatant as much as possible.2.Add 2.5 ml of Buffer P1 to the centrifuge tube in which the bacterial precipitate has been left (please check that RNase A has been added first) and suspend the bacterial precipitate by mixing thoroughly using a pipette or vortex shaker. Note: If the bacterial mass is not thoroughly mixed, it will affect the lysis effect and make the extraction amount and purity low.3.Add 2.5 ml of Buffer P2 to the centrifuge tube, mix gently up and down 8-10 times to fully lyse the organisms, and leave at room temperature for 3-5 minutes. At this point the solution should become clear and viscous. Note: Mix gently, do not shake vigorously, so as not to interrupt the genomic DNA and cause genomic DNA fragments to be mixed in the extracted plasmid. If the solution does not become clear, it suggests that the amount of bacteria may be too large and the lysis is not complete, and the amount of bacteria should be reduced.4.Add 2.5 ml of Buffer E3 to the centrifuge tube and mix immediately by turning up and down 8-10 times, at which time a white flocculent precipitate appears. Note: Buffer E3 should be mixed immediately after addition to avoid localized precipitation.5.Install the cap of the filter (Endo-Remover FX), transfer the solution obtained in step 4 to the filter, wait until the white flocculent precipitate floats on the upper layer of the solution, remove the cap of the filter, align the filter with a clean 15 ml centrifuge tube (supplied), and slowly push the handle (Plungers) to filter, so that as much as possible of the solution passes through, and the filtrate is collected in the centrifuge tube.6.Add 1/3 solution volume of isopropanol to the filtrate and mix upside down.7.Column Equilibrium: Add 1ml Buffer PS to the adsorption column (Spin Columns DX) that has been loaded into a 15ml centrifuge tube, centrifuge for 2 minutes at 2500 x g. Pour off the waste liquid from the centrifuge tube and put the adsorption column back into the centrifuge tube.8.The mixture of filtrate and isopropanol from step 6 was transferred to the equilibrated adsorption column (which had been loaded into a collection tube).9.Centrifuge at 2500 x g for 1 minute, pour off the waste solution in the collection tube and put the adsorption column back into the collection tube. Note: The maximum volume of the adsorption column is 4 ml, so the solution obtained in step 8 is passed through the column in 2 times.10.Add 2 ml of Buffer PW to the adsorption column (please check that anhydrous ethanol has been added first), centrifuge at 2500 × g for 1 min, and pour off the waste liquid in the collection tube.11.Repeat step 10.12.The adsorbent column was put back into the collection tube and centrifuged at 2500 × g for 2 min, the waste liquid was poured off, and the column was left to dry at room temperature for 5 min.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can interfere with subsequent enzymatic reactions (digestion, PCR, etc.)13. Place the adsorption column in a new 15 ml centrifuge tube, add 0.5-1 ml Endo-Free Buffer EB to the middle of the adsorbent membrane, leave it at room temperature for 2-5 minutes, centrifuge it at 2500 × g for 2 minutes, and collect the plasmid solution into the centrifuge tube. -20°C to store the plasmid.Note: 1) In order to increase the recovery efficiency of the plasmid, the obtained solution can be reintroduced into the adsorption column, left at room temperature for 2-5 minutes, centrifuged at 2500 x g for 2 minutes, and the plasmid solution can be collected into a centrifuge tube.2) When the plasmid copy number is low or >10kb, Endo-Free Buffer EB can increase the extraction efficiency by preheating at 65-70°C in a water bath... Read More | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export | Products contentNote: The amount of individual primers used is 1 µl, each N7-end primer can perform 10 DNA library constructs, and each kit can perform 240 DNA library constructs.Products IntroductionThis kit is a companion kit to the transposase-based Rapid DNA Library Construction Kit for Products contentNote: The amount of individual primers used is 1 µl, each N7-end primer can perform 10 DNA library constructs, and each kit can perform 240 DNA library constructs.Products IntroductionThis kit is a companion kit to the transposase-based Rapid DNA Library Construction Kit for Illumina platform library construction. Each kit contains one N5 primer and 24 N7 primers, which can be used to prepare 24 different single-ended Index libraries. All reagents provided in the kits have been subjected to stringent quality control and functional validation to maximize the stability and reproducibility of library construction. The libraries can be used for sequencing on Illumina platforms such as HiSeq X-10/4000/2500/2000 and MiSeq. Provide your own instruments, reagents and consumables1. Magnetic frame: DynaMagTM-2 is recommended.2. DNA purification and recovery kit: It is recommended to use Kangwei DNA purification and recovery kit by magnetic bead method.3. DNA building kit: It is recommended to use the Kangwei Century transposase method second-generation sequencing rapid DNA building kit.4. Anhydrous ethanol.5. Reaction tubes: It is recommended to use low adsorption PCR tubes with 1.5 ml centrifuge tubes; Tip: It is recommended to use a high quality filter tip to prevent contamination of kits and library samples. Pre-experiment Preparation and Important NotesPlease centrifuge briefly before opening the cap so that the liquid collects at the bottom of the tube to avoid cross-contamination between different primers. procedureFor the use of the CombiVision Second Generation Sequencing Multisample Primer Kit, please follow the CombiVision Second Generation Sequencing Rapid DNA Library Kit protocol. Index N501 Primer for Illumina Index N901-N996 Primer for Illumina... Read More |