| Description | Inquire | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export | Inquire | Product content: G665990Component200 TStorageG665990ABuffer PG100 mLRTG665990BBuffer PS60 mLRTG665990CBuffer PW (concentrate)50 mLRTG665990DBuffer EB30 mLRTG665990ESpin Columns DM with Collection Tubes200 EART Product Introduction:This kit uses a new silicon-based plasma membrane technology and Product content: G665990Component200 TStorageG665990ABuffer PG100 mLRTG665990BBuffer PS60 mLRTG665990CBuffer PW (concentrate)50 mLRTG665990DBuffer EB30 mLRTG665990ESpin Columns DM with Collection Tubes200 EART Product Introduction:This kit uses a new silicon-based plasma membrane technology and reagent formulation. Through the unique centrifugal adsorption column and the DNA washing elution step, 100 bp-10 kb DNA fragments can be recovered and purified from ordinary or low melting point agarose gel. The sol speed is fast and the recovery rate is high. The sol solution contains a pH indicator, which can be used to determine whether the sol recovery has reached the optimal state based on its color. Each adsorption column can adsorb up to 10 µ G DNA, while effectively removing impurities such as primers, enzymes, mineral oil, and agarose. The purified and recovered DNA has high purity and concentration, good integrity, and can be directly used for molecular biology experiments such as sequencing, linking and transformation, labeling, and in vitro transcription.Self prepared reagents: anhydrous ethanol, isopropanol.Preparation and important precautions before the experiment:1.Before the first use, anhydrous ethanol should be added to the Buffer PW according to the instructions on the reagent bottle label.2. Before use, please check the Buffer PG. If crystallization or precipitation occurs, it can be left in a 37 ℃ water bath for 3-5 minutes to restore clarity.3. It is best to use a new electrophoresis buffer during electrophoresis to avoid affecting the electrophoresis and recovery efficiency; The following experiment requires high requirements, please use TAE electrophoresis buffer as much as possible.4.When cutting glue, the UV irradiation time should be as short as possible to avoid damage to DNA.5. The recovery rate is related to the initial amount of DNA and the elution volume. The smaller the initial amount, the smaller the elution volume, and the lower the recovery rate.6. Preheat the water bath to 50 ℃.7. Buffer PG contains a pH indicator. When the pH is ≤ 7.5, the color of the solution is yellow, and DNA can effectively bind to the membrane. When the pH is too high, the color of the solution turns orange red and purple, which needs to be adjusted.8. All centrifugation steps can be performed at room temperature.Operation steps:1. Cut the single purpose DNA strip from the agarose gel (try to cut the excess), put it into a clean centrifuge tube (self prepared), and weigh and calculate the weight of the gel (record the weight of the centrifuge tube in advance).Attention: If the volume of the adhesive block is too large, it can be cut into small pieces.2. Add one time of the volume of Buffer PG (if the gel weighs 100 mg, its volume can be regarded as 100 µ l. And so on.3.50 ℃ water bath and gently invert the centrifuge tube every 2-3 minutes until the sol turns yellow to ensure full dissolution of the gel block. If there are still unsolved glue blocks, you can add some more sol solution or continue to let it stand for a few minutes until the glue blocks are completely dissolved.Note: 1) After the gel is completely dissolved, the gel solution is yellow, and subsequent operations can be carried out; If the glue solution is orange red or purple, 10-30 can be added to the glue solution µ 3 M sodium acetate (pH 5.0), adjust the color of the solution to yellow before proceeding with subsequent operations.2) After the gel block is completely dissolved, it is best to lower the temperature of the gel solution to room temperature before loading the column. The adsorption column has a weaker ability to bind DNA at higher temperatures.4. (Optional step) When the recovered fragment is less than 300 bp, add 1/2 of the gel volume of isopropanol, and mix it upside down (if the gel weighs 100 mg, add 50 µ Isopropanol of L.5. Column balance: Add 200 to the spin columns DM that have been loaded into the collection tube µ Centrifuge at 13000 rpm (~16200 × g) for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.6. Add the solution obtained from steps 3 or 4 to the adsorption column that has been loaded into the collection tube, let it stand at room temperature for 2 minutes, centrifuge at 13000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column in the collection tube.Attention: The volume of the adsorption column is 750 µ l. If the sample volume is greater than 750 µ L can be added in batches.7. Add 450 to the adsorption column µ LBuffer PW (please check if anhydrous ethanol has been added before use), centrifuge at 13000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column in the collection tube.Note: If purified DNA is used for salt sensitive experiments (such as flat end ligation or direct sequencing), it is recommended to add Buffer PW and let it stand for 2-5 minutes before centrifugation.8. Repeat step 7.9.13000 rpm for 1 minute and discard the waste liquid from the collection tube.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).10. Place the adsorption column into a new 1.5 ml centrifuge tube (provided by oneself), and add 50 drops to the middle position of the adsorption membrane in the air µ L Buffer EB, leave at room temperature for 2 minutes. Centrifuge at 13000 rpm for 1 minute and collect DNA solution- Store DNA at 20 ℃.Attention:1) To improve the recovery of DNA, the solution obtained by centrifugation can be re dropped onto the adsorption column, left at room temperature for 2 minutes, and centrifuged at 13000 rpm for 1 minute.2) The elution volume should not be less than 30 µ l. A small volume will affect the recovery efficiency.3) When recovering DNA fragments larger than 10 kb, Buffer EB should be preheated in a 50 ℃ water bath to increase recovery efficiency.Note: This reagent kit is also suitable for the purification and recovery of PCR products. Add an equal volume of Buffer PG to the PCR reaction solution and mix thoroughly (for small fragments with a recovery of less than 150bp, the solution volume can be increased to three times to improve the recovery rate). Follow step 5 above for further operations... Read More | N665917 Component 1 mL 5 mL Storage N665917A 2×SYBR qPCR MasterMix 1 mL 5×1 mL -20℃. Avoid freeze/ Thaw cycle. N665917B qPCR Primer Mix 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917C DNA Standard A 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917 Component 1 mL 5 mL Storage N665917A 2×SYBR qPCR MasterMix 1 mL 5×1 mL -20℃. Avoid freeze/ Thaw cycle. N665917B qPCR Primer Mix 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917C DNA Standard A 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917D DNA Standard B 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917E DNA Standard C 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917F DNA Standard D 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917G DNA Standard E 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917H 50×High ROX 40 µL 200 µL -20℃. Avoid freeze/ Thaw cycle.Product IntroductionThis is a dye-based (SYBR Green I) qPCR NGS library quantification kit for cfDNA, which provides the reaction mixture, DNA primer mixture, standards, and sample dilutions required for the qPCR process, making it a complete reagent system that is easy and convenient to use. The fluorescent dye SYBR Green I contained in the reaction mixture binds to all double-stranded DNA. The kit uses a new chemically modified high-efficiency hot-start polymerase, the activation of the enzyme needs to be incubated at 95 ℃ for 10 min. the product is highly specific, high amplification efficiency, the length of the standard in the kit (about 270bp) is comparable to the average length of the cfDNA NGS libraries (250-300bp), which is able to quickly and accurately quantitate the concentration of the constructed cfDNA libraries. quantification.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used in Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument.Instruments that do not require ROX calibration: Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96, etc.Instruments requiring Low ROX calibration: ABI Prism7500/7500 Fast, QuantStudio®3 System, QuantStudio®5 System, QuantStudio®6 Flex System, QuantStudio®7 Flex System, ViiA7 System, Stratagene Mx3000/Mx3005P, Corbett Rotor Gene 3000, and others.Instruments requiring High ROX calibration: ABI Prism7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, etc.NOTE: High Rox and Low Rox are formulated as described in Method of Use 2.Applicable scopeThis product is designed for the absolute quantification of the concentration of Illumina platform second generation sequencing libraries. The end of the library contains Illumina P5 and P7 microarray binding sequences, the length of which does not exceed 1kb, and the concentration is not less than 0.02pM can be used for quantitative experiments. The qPCR Primer Mix provided in the kit contains the following two primer sequences:Primer 1:5'-AAT GAT ACG GCG ACC ACC GA-3' Primer 2: 5'-CAA GCA GAA GAC GGC ATA CGA-3'The primer sequence can be used in advance to confirm whether the library can be amplified by that primer pair.UsageAmplification template preparationThe library samples to be detected were diluted with TE (10 mM Tris-Cl, pH 8.0, 1 mM EDTA), and the concentration after dilution was as close as possible to the range of 0.01-60 pM. 4°C on ice was set aside.qPCR reaction system preparationThe desired cryopreservation reagent is pre-melted completely and mixed by inverting several times before preparation, then centrifuged briefly and set aside.The base reaction system for 20 µl was as follows:Reagent20 µl Reaction system2×SYBR qPCR MasterMix10 µlqPCR Primer Mix0.8 µlTemplate4 µlddH₂O5.2 µlDescription: High Rox model: 1 µl High Rox per 50 µl of reaction system; Low Rox model: 1 µl High Rox per 500 µl of reaction system.Prepare a sufficient amount of reaction system mixture according to the need, mix well and add to the reaction wells in a volume of 16 µl per well, add the same volume of TE to the blank control, and then add the prepared standards and diluted samples to the corresponding reaction wells in a volume of 4 µl/well. It is recommended to use 20 µl reaction system, if you need to carry out a smaller system reaction, the system components can be reduced in equal proportion.3.qPCR reaction programIf the average length of the library is greater than 700bp, the annealing/extension time should be increased appropriately.Refer to the specific instrument setup program for dissolution curves.data analysisStandard curve productionThe standard curve was plotted according to the data processing Excel sheet. The correlation coefficient R2 of the standard curve should be not less than 0.99, and the slope should be located between -3.1 and -3.6 when the Ct value is the longitudinal coordinate. If the parameters of the standard curve are unreasonable, it is recommended to repeat the experiment.DNA Standard NameDNA Standard ConcentrationDNA Standard A60 pMDNA Standard B6 pMDNA Standard C0.6 pMDNA Standard D0.06 pMDNA Standard E0.006 pMLibrary Concentration CalculationsThe difference in Ct between the three replicate wells of the experiment should be no more than 0.2, otherwise the invalid data should be deleted or the experiment should be repeated. Do not use the Ct outside the valid Ct range of the standard curve to calculate the concentration of the diluted libraries. Please refer to the data processing Excel of this product for the specific library concentration calculation method.matters needing attentionThese instructions should be read in detail before testing. It should be carried out by personnel with specialized experience or qualified by training.Mix gently by turning up and down, avoid foaming as much as possible, and centrifuge for a short time before use.Avoid repeated freezing and thawing of this product; repeated freezing and thawing may degrade product performance.When preparing reaction solutions, use new or non-contaminated tips and centrifuge tubes to prevent contamination as much as possible... Read More |