| Description | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export | Apoptosis refers to the cell autonomous and orderly death controlled by genes to maintain the stability of the internal environment. Apoptosis is different from cell necrosis. Apoptosis generally refers to a programmed cell death process that occurs during the development of body cells or under the Apoptosis refers to the cell autonomous and orderly death controlled by genes to maintain the stability of the internal environment. Apoptosis is different from cell necrosis. Apoptosis generally refers to a programmed cell death process that occurs during the development of body cells or under the action of some factors through the regulation of intracellular genes and their products. Cell necrosis is a cell death process that is caused by strong physical and chemical or biological factors to cause disordered changes in cells. The difference between apoptosis and necrosis lies in the characteristic morphological and biochemical changes, including the changes of cell membrane permeability and nuclear chromatin, the contraction of cytoplasm and the loss of membrane asymmetry. The oxazole yellow/pi membrane permeability apoptosis detection kit produced by our company is a dual fluorescence detection kit based on oxazole yellow and PI dyes. This kit is suitable for fluorescence microscopy, flow cytometry, fluorescence microplate reader and other fluorescence detection systems. Oxazole yellow is a non cell membrane penetrating cyanine monomer green fluorescent dye with high affinity for DNA. It basically has no fluorescence when it is not bound to DNA, but can emit bright green fluorescence after binding to DNA. When apoptosis occurs, the permeability of cell membrane changes. At this time, oxazole yellow can enter the cell and bind to DNA, emitting bright green fluorescence. Therefore, it is often used for the detection of apoptosis. It should be noted that oxazole yellow can also stain dead cells, so it needs to be double stained with PI that specifically fluorescently stains dead cells to effectively determine apoptosis. PI (propidium iodide) is a red fluorescent dye that can stain DNA. It is an analog of pyridine bromide that releases red fluorescence after embedding double stranded DNA. Although PI cannot pass through the membrane of living cells, it can cross the damaged cell membrane of dead cells to stain nuclei. Therefore, oxazole yellow combined with PI can be directly used for the detection of apoptosis. Apoptotic cells show green fluorescence, dead cells show both red and green fluorescence positive, and living cells have little or no fluorescence.Components: Components O598364-50T A. Oxazole yellow dye 50 µL B. Propidium Iodide (PI) 50 µLUsage (using flow cytometry as an example):1. Cell preparation(1) For adherent cells, after trypsin digestion, resuspend in culture medium and wash once with pre cooled PBS; The digestion time of trypsin should not be too long to prevent false positives. Note: Digest with trypsin and allow the cells to recover in the optimal cell culture conditions and medium for about 30 minutes, then stain.(2) For suspended cells, centrifuge at 1000 rpm for 5 minutes, discard the supernatant, and wash once with pre cooled PBS.2. Cell stainingSuspend cells in pre cooled PBS, with a recommended cell count of 106 cells/mL per sample. Add 1 µ L Oxazole Yellow and 1 µ L to 1 mL of the samplePI, Gently blow and mix well. Incubate on ice in the dark for 30 minutes. Note: We suggest adding the following two experimental controls:Blank tube: negative control group cells, without dye, used to regulate voltage.Single staining tube: Positive control group cells were treated with only two tubes, Oxazole yellow and PI, for regulating compensation.3. Flow detectionAfter incubation, the sample can be directly detected by flow cytometry, or centrifuged at 1000 rpm for 5 minutes, the supernatant can be aspirated, and the sample can be resuspended in 1 mL of pre cooled PBS for flow cytometry detection. Oxazole yellow can be excited by a 488 nm laser, and the detected fluorescence emission spectrum is around 530 ± 30 nm (FITC channel), while the PI channel emission spectrum is around 617 nm (PI or PE channel).Product parameters:Oxazole yellow dye:ex/em = 491 / 509 nm (bound DNA); Propidium iodine:ex/em = 535 / 617 nm (combined with DMatters needing attention:1. please centrifuge the product to the bottom of the tube immediately before use, and then conduct subsequent experiments. 2. fluorescent dyes have quenching problems. Please try to avoid light to slow down fluorescence quenching. 3. for your safety and health, please wear experimental clothes and disposable gloves.Scope of application:Membrane permeability apoptosis assay... Read More | This reagent kit uses highly sensitive silver dye, which can be applied to protein staining of denatured and non denatured gels. It has the advantages of clear target bands, low background, and flexible control of operation time. In addition, this reagent kit has added a short-term sensitization This reagent kit uses highly sensitive silver dye, which can be applied to protein staining of denatured and non denatured gels. It has the advantages of clear target bands, low background, and flexible control of operation time. In addition, this reagent kit has added a short-term sensitization step, which can significantly reduce the background and enhance the brightness of the target band. P665901Component20 TStorageP665901ASilver Stain Sensitizer (500×)2×1 mLRTP665901BSilver Stain Enhancer3 mLRTP665901CSilver Stain2×250 mLRTP665901DSilver Stain Developer4×125 mLRT Matters needing attention1. Please prepare 50 ml of fixed solution (ultrapure water: ethanol: acetic acid=6:3:1), 50 ml of eluent (10% ethanol), and 50 ml of termination solution (5% acetic acid) in advance.2. Please use deionized water and clean glass or plastic containers during operation, and wear disposable gloves for operation.The entire silver dyeing process needs to be carried out on a shaker, with a rotation speed of about 60 rpm.4. Self prepared ethanol and glacial acetic acid are required.Instructions for useThe dosage of each solution in the following operation steps takes the gel with a size of 8.5 × 5.5 cm and a thickness of 1.0 mm as an example. The gel is immersed in the solution completely, and is operated on a shaker, with a general dosage of 25 ml. For large gel, the dosage of each solution should be scaled up according to the gel volume. Please prepare 50 ml of fixed solution (ultrapure water: ethanol: glacial acetic acid=6:3:1), 50 ml of eluent (10% ethanol), and 50 ml of termination solution (5% glacial acetic acid) in advance.1. Water washing: After electrophoresis is completed, wash the gel twice with ultrapure water for 5 minutes each time.2. Fixation: Fix the gel twice with 25 ml of fixative solution for 15 minutes each time.3. Elution: Wash the adhesive twice with eluent, each time for 5 minutes.4. Water washing: Wash the glue twice with ultrapure water, each time for 5 minutes.5. Sensitization: put the gel washed in the previous step into the silver dye sensitization working solution, incubate it accurately for 1 minute at room temperature, and then wash it with ultrapure water for three times, each time for 20 seconds. Preparation of silver staining sensitization working solution: Take 50 µ l Silver Stain Sensitivity (500 x) and add it to 25 ml of ultrapure water, mix well.6. Silver staining: discard ultrapure water and incubate gel in silver staining working solution for 30 minutes. Preparation of silver staining working solution: Take 25ml Silver Stain and add 50 µ l Silver Stain Enhanced to mix well.7. Water washing: Quickly wash the glue twice with ultrapure water, with each washing accurately controlled for 20 seconds.8. Development: Immerse the washed gel in the developer immediately and incubate it at room temperature for 2-3 minutes until the protein strip is clear. Preparation of developer: Take 25ml Silver Stain Developer and add 30 µ l Silver Stain Enhanced to mix well. Attention: Within 30 seconds of development, protein bands begin to appear and continue to develop for 2-3 minutes. If the protein band appears lighter, the development time can be appropriately extended to 5 minutes or more.9. Termination: After washing the developer on the gel with the termination solution, soak the gel in a new termination solution to react for 10 minutes.Experimental imagesSilver staining results of BSA protein samples after 10% SDS-PAGE gel electrophoresisThe molecular weight of BSA protein is about 66 kD, and the loading amounts from left to right are 50 ng, 10 ng, and 5 ng, respectively... Read More | Q665720 Component 200T Storage Q665720A Buffer L2 25 mL RT Q665720B Buffer N3 80 mL RT Q665720C Buffer PB 35 mL RT Q665720D Buffer PW (concentrate) 25 mL RT Q665720E Buffer EB 30 mL RT Q665720F RNase A (10 mg/mL) 800 渭L RT Q665720G Spin Columns DM with Collection Tubes 200 EA RTProduct Q665720 Component 200T Storage Q665720A Buffer L2 25 mL RT Q665720B Buffer N3 80 mL RT Q665720C Buffer PB 35 mL RT Q665720D Buffer PW (concentrate) 25 mL RT Q665720E Buffer EB 30 mL RT Q665720F RNase A (10 mg/mL) 800 渭L RT Q665720G Spin Columns DM with Collection Tubes 200 EA RTProduct IntroductionThe biggest feature of this kit: simple and fast, high extraction volume. The whole extraction process does not take more than 10 minutes, without centrifugation to collect bacteria and resuspend the bacterium, directly add the unique super lysate Buffer L2 to the cultured bacterial solution, followed by neutralization, centrifugation and passing through the column, and the extracted plasmid can be as high as 30 µg, and maximize the removal of proteins, genomes and other impurities. The extracted plasmid DNA can be directly used for bacterial transformation, digestion, PCR, in vitro transcription, sequencing and other downstream experiments.Self-contained reagent: anhydrous ethanol.Pre-experiment Preparation and Important Notes1. The kit can be stored in a dry, room temperature (15-30°C) environment for 1 year. For longer storage, the centrifuge columns can be placed at 2-8°C.2. Before the first use, add all of the RNase A solution to Buffer N3, mix well, and store at 2-8°C.3. Anhydrous ethanol should be added to Buffer PW before the first use according to the instructions on the reagent bottle label.4. If there is any precipitation in Buffer L2 before use, please put it in a 37℃ water bath and keep mixing until the solution becomes clear before use.Operation steps1. Take 600 µl of bacterial culture into a 1.5 ml centrifuge tube (supplied).2. Add 100 µl of Buffer L2 to the above centrifuge tube and gently turn the solution up and down 8 times; the solution should change from turbid to a clear purple color, indicating complete lysis. The cleavage time should not exceed 2 minutes.3. Add 350 µl of Buffer N3 to the above centrifuge tube (please check that RNaseA has been added first) and immediately mix well by turning up and down about 8-10 times, at which point the solution should turn completely yellow and a yellow precipitate should form. centrifuge at 13,000 rpm for 2-3 minutes.4. Slowly pour the supernatant obtained in step 3 into the prepared adsorption columns (Spin Columns DM with Collection Tubes) to avoid sedimentation into the columns.5. Centrifuge at 13,000 rpm for 15 seconds, pour off the waste liquid in the collection tube, and put the adsorption column back into the collection tube.6. Add 150 µl Buffer PB to the adsorption column and centrifuge at 13,000 rpm for 15 seconds.7. Add 400 µl Buffer PW to the adsorption column (please check that anhydrous ethanol has been added first) and centrifuge at 13,000 rpm for 1 minute.8. Place the adsorbent column in a new centrifuge tube (self-provided), add 30-100 µl Buffer EB to the middle part of the adsorbent membrane, centrifuge at 13,000 rpm for 1 min, collect the plasmid DNA, and store at -20°C for long term storage.When the amount of extracted bacterial liquid is >600µl, the following procedure can be used:1. This kit can extract up to 3ml of bacterial solution, if the amount of extracted bacterial solution is more than 600µl, it is necessary to centrifuge the bacterial solution exceeding 600µl at 13,000rpm for 30 seconds (to collect the bacterial body), discard the supernatant and then add 600µl of bacterial solution, and then resuspend the bacterial body at the bottom of the tube thoroughly and then proceed to the following operation.2. Add 100µl Buffer L2 to the above centrifuge tube, gently invert the solution up and down 10 times, if the solution is not clarified, need to continue to invert the mixing until the solution becomes a clear purple color, the lysis time should not be more than 2 minutes. (If the solution is still turbid, the amount of bacteria is too large, and the amount of bacteria should be reduced appropriately.)3. Add 350 µl of Buffer N3 to the above centrifuge tube (please check that RNaseA has been added first) and immediately mix well by turning up and down until the purple solution turns completely yellow and a yellow precipitate is formed before proceeding to the next step. centrifuge at 13,000 rpm for 5 minutes.4. Transfer the supernatant to a new centrifuge tube, add 200 µl of isopropanol, mix up and down several times, mix well and transfer to the adsorbent column (Spin Columns DM with Collection Tubes), due to the amount of solution is too large, this time, it is necessary to centrifuge the column in two separate times, centrifugation at 13,000 rpm for 15 seconds, pour off the waste liquid in the collection tube, and put the adsorbent column back to the The adsorbent column should be placed back into the collection tube.5. Add 150 µl Buffer PB to the adsorption column and centrifuge at 13,000 rpm for 15 seconds.6. Add 400 µl Buffer PW to the adsorption column (please check that anhydrous ethanol has been added first) and centrifuge at 13,000 rpm for 1 minute.7. Place the adsorbent column in a new centrifuge tube (self-provided), add 50-200 µl Buffer EB to the middle part of the adsorbent membrane, leave it at room temperature for 2 min, centrifuge at 13,000 rpm for 1 min, collect the plasmid DNA, and store it at -20°C for a long time... Read More | Products contentProducts IntroductionThe Single Cell Whole Genome Amplification Kit can be used as a template for whole genome amplification of single cells or micro samples. The total time for single-cell amplification is about 3 hours, and 2-5 µg of genomic DNA, with a size of 200-1500 bp, Products contentProducts IntroductionThe Single Cell Whole Genome Amplification Kit can be used as a template for whole genome amplification of single cells or micro samples. The total time for single-cell amplification is about 3 hours, and 2-5 µg of genomic DNA, with a size of 200-1500 bp, can be obtained after lysis, pre-amplification and amplification. The amplified product can be widely used in second-generation sequencing, large fragment copy number variation analysis, SNP typing, qPCR analysis and gene chip analysis.Bring your own instruments and reagentsPCR instrument Reaction tubes: low adsorption tubes recommended Gun Heads: High quality filtered gun heads are recommended Microcentrifuge, vortex mixercaveat The sensitivity of this product is very high, the experimental operation should be completed in a positive pressure ultra-clean bench or clean environment, the concentration of the amplification reaction products is high, should be well isolated to avoid aerosol contamination caused by amplification products.Operation flow diagramprocedurePre-experiment preparationSingle cells were obtained by flow cytometry sorting, buffer dilution, micromanipulation and laser microdissection. It is recommended that the cells be washed prior to the experiments with a 1× PBS solution free of Mg2+ and Ca2+, taking care to ensure that the volume of PBS solution in subsequent experiments does not exceed 2 µl. take note of Since the whole experiment is carried out in the same PCR tube and the reaction volume is small, the pipette tip should not touch the liquid in the tube when adding liquid, so as to avoid taking single cells or DNA out of the reaction system; when pipetting, please add the liquid along the wall of the tube carefully and do not blow the liquid in the PCR tube; before the reaction, please centrifuge briefly to make sure that the liquid in the reaction system is mixed evenly. Thaw the cell lysate, pre-amplifier and amplifier on ice before use.cell lysis 1)Mix Cell Lysis Buffer and Cell Lysis Enzyme according to the number of reactions N, shake to mix, centrifuge briefly and set aside.2)Mix single cells with the cell lysis mix in a PCR tube and run the following program.2. Pre-amplification reaction1)Mix Cell Lysis Buffer and Cell Lysis Enzyme according to the number of reactions N, shake to mix, centrifuge briefly and set aside.2)Add 5 µl of pre-amplification mix to 10 µl of lysis reaction product from the previous step and run the following program. 3. Amplification reaction1)Mix Amplification Buffer and Amp Enzyme Mix according to the number of reactions N, mix with shaking, centrifuge briefly and set aside.2)Add 60 µl of amplification mix to 15 µl of pre-amplification reaction product from the previous step and run the following program.Note: The number of cycles can be adjusted as needed, 14 cycles are recommended for single cells obtained by flow sorting, etc.Amplification product detection 1. Agarose gel electrophoresis 5 µl of the amplified product was subjected to agarose gel electrophoresis (1% agarose gel, 110 V, 25-35 min), and the amplified product was 200-1500 bp in size. 2. Quantitative Amplification products were subjected to magnetic bead or column purification, and purified products were quantified using Qubit with a final yield of 2-5 µg... Read More |