| Description | Animal liver and kidneys are the main organs for amino acid metabolism. Therefore, changes in urinary amino acids best reflect the physiological state of the liver and kidneys. Additionally, amino acid levels can indicate conditions such as burns and typhoid fever. The amino acid content in plants Animal liver and kidneys are the main organs for amino acid metabolism. Therefore, changes in urinary amino acids best reflect the physiological state of the liver and kidneys. Additionally, amino acid levels can indicate conditions such as burns and typhoid fever. The amino acid content in plants is significant for studying nitrogen metabolism changes under different conditions and during various growth and development stages, as well as for understanding nitrogen absorption, transport, assimilation, and nutritional status in plants.Detection Principle: The α-amino group of amino acids reacts with ninhydrin hydrate to produce a blue-purple compound with a characteristic absorption peak at 570 nm. The amino acid content is calculated by measuring the absorbance at 570 nm.Detection Range: 0.625 - 40 µmol/mLSensitivity: 0.5 µmol/mLApplicable Samples: Serum (plasma), animal/plant tissues, cells, cell culture supernatants, bacteria, urineG1501758Component96TStorageG1501758AExtraction Buffer100 mL2-8℃G1501758BAssay Buffer10 mL2-8℃G1501758CSubstrate1EA2-8℃. Store in the dark.G1501758DStandard (10mg Cysteine)1EA2-8℃. Store in the dark.User-Prepared Instruments and ReagentsMicroplate reader or visible spectrophotometer (capable of measuring absorbance at 570 nm)96-well plate or micro glass cuvettes, adjustable micropipettes and tipsRefrigerated centrifuge, water bathDeionized water, EthanolHomogenizer (for tissue samples)Experimental Procedure1. Reagent PreparationReagent NameReagent PreparationNotesExtraction BufferReady-to-use; Equilibrate to room temperature before use.Store at 4°C.Assay BufferReady-to-use; Equilibrate to room temperature before use.Store at 4°C. Toxic and irritant. Perform experiments in a fume hood.SubstrateToxic and irritant. Perform experiments in a fume hood.Working SubstratePrepare before use: Dissolve in 4 mL of 95% Ethanol.Unused dissolved substrate can be stored at 4°C protected from light for one week. For long-term storage, aliquot and store at -20°C protected from light for one month. Avoid repeated freeze-thaw cycles.StandardPrepare before use: Add 2.066 mL deionized water to dissolve completely, resulting in a 40 µmol/mL stock.Unused dissolved standard can be stored at 4°C for one week. For long-term storage, aliquot and store at -20°C for one month. Avoid repeated freeze-thaw cycles.2. Standard Curve SetupDilute the 40 µmol/mL standard stock solution with deionized water to concentrations of 20, 10, 5, 2.5, 1.25, and 0.625 µmol/mL as shown in the table below.TubeStandard VolumeDeionized Water Volume (µL)Standard Concentration (µmol/mL)Std.1200µL of 40µmol/mL040Std.2100µL of Std.110020Std.3100µL of Std.210010Std.4100µL of Std.31005Std.5100µL of Std.41002.5Std.6100µL of Std.51001.25Std.7100µL of Std.61000.625Note: The standard curve must be generated with each experiment. Diluted standard solutions are unstable and must be used within 4 hours.3. Sample PreparationNote: Fresh samples are recommended. If not used immediately, samples can be stored at -80°C for up to one month.3.1 Animal TissueWeigh approximately 0.1 g of tissue. Add 1 mL of Extraction Buffer and homogenize thoroughly at room temperature. Transfer the homogenate to a 1.5 mL microcentrifuge tube. Cap tightly (to prevent moisture loss) and incubate in a boiling water bath for 15 minutes. Cool with tap water. Centrifuge at 10,000 rpm for 10 minutes at room temperature. Collect the supernatant for assay.3.2 Plant TissueWeigh approximately 0.1 g of tissue. Add 1 mL of Extraction Buffer and grind. Sonicate for 5 minutes at room temperature (power 20% or 200W, pulse 3s on, 7s off, repeat 30 times). Transfer to a 1.5 mL microcentrifuge tube. Cap tightly (to prevent moisture loss) and incubate in a boiling water bath for 15 minutes. Cool with tap water. Centrifuge at 10,000 rpm for 10 minutes at room temperature. Collect the supernatant for assay.3.3 Cells or BacteriaCollect 5 million cells or bacteria into a centrifuge tube. Wash cells with cold PBS, centrifuge, and discard the supernatant. Add 1 mL of Extraction Buffer. Sonicate for 5 minutes at room temperature (power 20% or 200W, pulse 3s on, 7s off, repeat 30 times). Transfer to a 1.5 mL microcentrifuge tube. Cap tightly (to prevent moisture loss) and incubate in a boiling water bath for 15 minutes. Cool with tap water. Centrifuge at 10,000 rpm for 10 minutes at room temperature. Collect the supernatant for assay.3.4 Serum (Plasma), Cell Culture Supernatant, Urine, and Other LiquidsPipette 0.5 mL of the liquid sample and add 0.5 mL of Extraction Buffer. Cap tightly (to prevent moisture loss) and incubate in a boiling water bath for 15 minutes. Cool with tap water. Centrifuge at 10,000 rpm for 10 minutes at room temperature. Collect the supernatant for assay.Note: If protein concentration measurement is required, use Aladdin's BCA Protein Quantification Kit (B665595) or Ready-to-Use BCA Protein Quantification Kit (R1491648).4. Assay Steps4.1 Preheat the microplate reader or visible spectrophotometer for at least 30 minutes. Set the wavelength to 570 nm. For spectrophotometers, zero the instrument with deionized water.4.2 Sample Measurement (Add reagents sequentially into microcentrifuge tubes as below):ReagentBlank Tube (µL)Standard Tube (µL)Test Tube (µL)Deionized Water1000Standard (various conc.)0100Sample0010Working Substrate202020Assay Buffer5050504.3 Mix well and cap the tubes tightly (to prevent moisture loss). Incubate in a boiling water bath for 5 minutes. Cool in tap water for 10 seconds. Add 120 µL of 60% ethanol to each tube and invert several times to mix. Transfer 150 µL from each tube to the corresponding wells of a 96-well plate or micro glass cuvette. Measure the absorbance at 570 nm, recorded as A blank, A standard, and A test. Calculate ΔA test = A test - A blank and ΔA standard = A standard - A blank (The blank tube only needs to be prepared once). All measurements must be completed within 30 minutes after color development. Note:It is recommended to perform a preliminary test with 2-3 samples expected to have significant differences before the formal experiment. If A <sub> test </sub> is greater than 2.0, dilute the sample further with deionized water and multiply the result by the dilution factor.Proline and hydroxyproline do not produce an absorption peak at 570 nm when reacting with ninhydrin. Therefore, the results measured at 570 nm do not include these two amino acids.5. Calculation of ResultsNote: We provide two formulas, including the derived formula and a simplified version. They are equivalent. It is recommended to use the simplified formula in bold for final calculation.5.1 Standard Curve PlottingPlot the standard concentration (y-axis) against ΔA standard (x-axis) to generate the standard curve. Substitute ΔA test into the standard curve equation to calculate y (µmol/mL).5.2 Sample Amino Acid Content Calculation(1) Based on Sample WeightAmino Acid Content (µmol/g weight) = y ÷ (W ÷ V<sub>extraction</sub>) × n = y ÷ W × n(2) Based on Protein ConcentrationAmino Acid Content (µmol/mg prot) = y ÷ Cpr × n(3) Based on Bacterial or Cell CountAmino Acid Content (µmol/10⁴ cells) = y ÷ (Count ÷ V<sub>extraction</sub>) × n = y ÷ 500 × n = 0.002 × y × n(4) Based on Liquid VolumeAmino Acid Content (µmol/mL) = y × 2 × nParameter Definitions:W: Sample weight (g)V extraction : Volume of Extraction Buffer added (1 mL)n: Sample dilution factorCpr: Protein concentration of the supernatant (mg/mL)500: Total number of bacteria or cells (5 million)2: Dilution factor for liquid samples [(0.5 mL sample + 0.5 mL Buffer) / 0.5 mL sample = 2]6. Representative ResultsTypical Standard Curve: y = 20.349x - 0.423, R² = 0.9971 Figure 1: Total Amino Acid Standard Curve Precautions1. Biochemical reagents are generally irritating, biologically toxic, etc. For your safety and health, please use appropriate biosafety precautions throughout the experiment, including wearing lab coats, masks, gloves, head covers, etc. Perform experiments in a fume hood or biosafety cabinet.2. This product is for research use only. Not for use in clinical diagnosis... Read More | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export | Product content: Component O66550510 preps O665505 50 preps Blocking Buffer 100 ml 500 ml Antibody Pretreat Solution( HRP/Mouse ) 1 ml 5 × 1 ml Dilution Buffer 100 ml 500 ml Wash Buffer( 10× ) 100 ml 500 mlProduct Introduction:The one-step rapid WB assay kit (Product content: Component O66550510 preps O665505 50 preps Blocking Buffer 100 ml 500 ml Antibody Pretreat Solution( HRP/Mouse ) 1 ml 5 × 1 ml Dilution Buffer 100 ml 500 ml Wash Buffer( 10× ) 100 ml 500 mlProduct Introduction:The one-step rapid WB assay kit (mouse) is the latest Western Blot detection kit developed by Kangwei Century, which can obtain high-quality Western Blot results in about 1 hour. It is easy to operate, has high detection sensitivity, low background, does not require the addition of secondary antibodies, and has strong system stability. The conventional Western Blot indirect detection process (blocking, primary antibody binding, and secondary antibody binding) requires a long time, a complex experimental process, and requires multi-step condition optimization. After transferring the protein on the gel to the carrier membrane, incubate it with the blocking solution in the reagent kit for 5 minutes, and then incubate the carrier membrane with the primary antibody treated with antibody reaction solution. After washing three times (5 minutes each time), luminescence or colorimetric detection can be performed. This reagent kit is designed for use in experimental systems where the target protein primary antibody is derived from mice.Notes:1. The customer prepares their own mouse source primary antibody.2. Before using Blocking Buffer blocking solution, Antibody Pretreat Solution (HRP/Mouse) antibody reaction solution (mouse), and Wash Buffer (10 x) rinse solution, please mix thoroughly.3. If there is precipitation in the rinsing solution when stored at 2-8 ℃, please restore it to room temperature, dissolve the precipitation, and use it normally. The 1x rinsing solution can be stored at room temperature for one month.4. It is recommended to stain the membrane with reagents such as spring red after the transfer is completed, and cut off any excess parts on the membrane to increase the efficiency of the reagents.5. The optimal dilution amount for primary antibody and antibody reaction solution HRP (mouse) needs to be determined through preliminary experiments.6. The antibody reaction solution HRP (mouse), antibody dilution solution, and antibody dosage can be increased or decreased proportionally according to the size of the membrane.7. The antibody dilution solution containing the first antibody can be recycled and reused once. It is recommended not to reuse antibodies with poor specificity and affinity. If the recovered antibody is used within 1-2 days and stored at 2-8 ℃ for long-term storage, please freeze it at -20 ℃ to avoid repeated freeze-thaw cycles.8. If there is a high background, please adjust the amount of antibodies and increase the number of times the film is washed.9. All reagents in the reagent kit should be stored at 2-8 ℃ to avoid freezing and thawing.Operation steps:This product is suitable for the sealing and antibody incubation steps after membrane transfer, taking a 5 cm x 8 cm membrane as an example:1. Preparation of rinsing solution: Dilute 10 ml of Wash Buffer (10 x) with distilled water to 100 ml, which is 1 x Wash Buffer. Set aside. Use 8-10 ml for each film wash.2. Sealing: After the membrane transfer is completed, immerse the membrane in 10 ml Blocking Buffer and seal at room temperature for 5 minutes.3. Rinse: Pour off the sealing solution, add 8-10 ml of 1 x Wash Buffer, and rinse at a high speed on a shaker for 1 minute.4. Prepare antibody incubation solution while washing the membrane: Take Antibody Pretreat Solution (HRP/Mouse) 100 µ Add mouse derived primary antibody 3-10 into the centrifuge tube µ g. Suck and beat the gun head until thoroughly mixed, and incubate at room temperature for 5 minutes. Add to 10 ml Dilution Buffer and mix well. Note: 1) The dosage of primary antibody can also be adjusted according to the dilution of the antibody. Taking the final dilution of antibodies at 1:1000 as an example, take 100 µ Add HRP (mouse) antibody reaction solution into the EP tube and add 10 µ Add the first antibody to 10 ml of antibody diluent, mix well, and incubate at room temperature for 5 minutes. 2) If the membrane area is small, the amount of antibodies, reaction solution, and diluent can be reduced proportionally.5. After completing step 3, pour out the rinsing solution and add the antibody incubation solution mixed with primary antibody, Antibody Pretreat Solution (HRP/Mouse), and Dilution Buffer to the membrane (ensuring that the incubation solution completely submerges the surface of the membrane). Incubate at room temperature on a shaker at around 60 rpm for 40 minutes.6. Discard (recover) the antibody incubation solution and rinse 3-5 times with the prepared 1 x Wash Buffer, each time for 3 minutes. 7. Conduct subsequent testing. It is recommended to use ECL or DAB methods for testing.Application examples:Example 1 Antigen is 293T cell lysateA: Normal WB control: beta actin mouse monoclonal antibody (CW0096) 5 µ Incubate at room temperature for 40 minutes, wash the film and dilute the secondary antibody sheep anti mouse HRP (CW0102) 1:10000. Incubate at room temperature for 40 minutes and expose ECL (CW0049).B: One step method WB: beta actin mouse monoclonal antibody (CW0096) 5 µ Incubate at room temperature for 40 minutes and expose ECL (CW0049).Example 2 Antigen is E. coli multi label protein lysateC: Normal WB control: GST mouse monoclonal antibody (CW0084) 2.5 µ Incubate at room temperature for 40 minutes, wash the film and dilute the secondary antibody sheep anti mouse HRP (CW0102) 1:10000. Incubate at room temperature for 40 minutes and expose ECL (CW0049).D: One step method WB: GST mouse monoclonal antibody (CW0084) was incubated at room temperature with 2.5ug for 40 minutes, and ECL (CW0049) was exposed... Read More | Products contentProducts IntroductionThe Single Cell Whole Genome Amplification Kit can be used as a template for whole genome amplification of single cells or micro samples. The total time for single-cell amplification is about 3 hours, and 2-5 µg of genomic DNA, with a size of 200-1500 bp, Products contentProducts IntroductionThe Single Cell Whole Genome Amplification Kit can be used as a template for whole genome amplification of single cells or micro samples. The total time for single-cell amplification is about 3 hours, and 2-5 µg of genomic DNA, with a size of 200-1500 bp, can be obtained after lysis, pre-amplification and amplification. The amplified product can be widely used in second-generation sequencing, large fragment copy number variation analysis, SNP typing, qPCR analysis and gene chip analysis.Bring your own instruments and reagentsPCR instrument Reaction tubes: low adsorption tubes recommended Gun Heads: High quality filtered gun heads are recommended Microcentrifuge, vortex mixercaveat The sensitivity of this product is very high, the experimental operation should be completed in a positive pressure ultra-clean bench or clean environment, the concentration of the amplification reaction products is high, should be well isolated to avoid aerosol contamination caused by amplification products.Operation flow diagramprocedurePre-experiment preparationSingle cells were obtained by flow cytometry sorting, buffer dilution, micromanipulation and laser microdissection. It is recommended that the cells be washed prior to the experiments with a 1× PBS solution free of Mg2+ and Ca2+, taking care to ensure that the volume of PBS solution in subsequent experiments does not exceed 2 µl. take note of Since the whole experiment is carried out in the same PCR tube and the reaction volume is small, the pipette tip should not touch the liquid in the tube when adding liquid, so as to avoid taking single cells or DNA out of the reaction system; when pipetting, please add the liquid along the wall of the tube carefully and do not blow the liquid in the PCR tube; before the reaction, please centrifuge briefly to make sure that the liquid in the reaction system is mixed evenly. Thaw the cell lysate, pre-amplifier and amplifier on ice before use.cell lysis 1)Mix Cell Lysis Buffer and Cell Lysis Enzyme according to the number of reactions N, shake to mix, centrifuge briefly and set aside.2)Mix single cells with the cell lysis mix in a PCR tube and run the following program.2. Pre-amplification reaction1)Mix Cell Lysis Buffer and Cell Lysis Enzyme according to the number of reactions N, shake to mix, centrifuge briefly and set aside.2)Add 5 µl of pre-amplification mix to 10 µl of lysis reaction product from the previous step and run the following program. 3. Amplification reaction1)Mix Amplification Buffer and Amp Enzyme Mix according to the number of reactions N, mix with shaking, centrifuge briefly and set aside.2)Add 60 µl of amplification mix to 15 µl of pre-amplification reaction product from the previous step and run the following program.Note: The number of cycles can be adjusted as needed, 14 cycles are recommended for single cells obtained by flow sorting, etc.Amplification product detection 1. Agarose gel electrophoresis 5 µl of the amplified product was subjected to agarose gel electrophoresis (1% agarose gel, 110 V, 25-35 min), and the amplified product was 200-1500 bp in size. 2. Quantitative Amplification products were subjected to magnetic bead or column purification, and purified products were quantified using Qubit with a final yield of 2-5 µg... Read More | S665948 Component 1 mL 5 mL Storage S665948A 2×SYBR qPCR Master Mix 1 mL 5×1 mL -20℃. Avoid freeze/ Thaw cycle. S665948B qPCR Primer Mix 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948C DNA Standard 1 100 µL 5×100 µL -20℃. Avoid S665948 Component 1 mL 5 mL Storage S665948A 2×SYBR qPCR Master Mix 1 mL 5×1 mL -20℃. Avoid freeze/ Thaw cycle. S665948B qPCR Primer Mix 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948C DNA Standard 1 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948D DNA Standard 2 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948E DNA Standard 3 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948F DNA Standard 4 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948G DNA Standard 5 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948H 50×High ROX 40 µL 200 µL -20℃. Avoid freeze/ Thaw cycle.Product IntroductionThis product is used for real-time fluorescence quantitative PCR (qPCR) using the product after NGS library construction by dye method (SYBR Green I). The kit provides the reaction mixture, DNA primer mixture, and standards required for the qPCR process, and the reagent system is complete, easy and convenient to operate. The kit uses a new chemically modified high-efficiency hot-start polymerase, the activation of the enzyme needs to be incubated at 95 ℃ for 10 min. the product is highly specific, high amplification efficiency, and able to quickly and accurately quantify the concentration of the constructed library. It is suitable for fluorescent quantitative PCR instruments that do not require ROX as a calibration dye, such as Roche LightCycler 480, Roche LightCyler 96, Bio-radiCyleriQ, iQ5, CFX96.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used in Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument.Instruments that do not require ROX calibration: Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96, etc.Instruments requiring Low ROX calibration: ABI Prism7500/7500 Fast, QuantStudio®3 System, QuantStudio®5 System, QuantStudio®6 Flex System, QuantStudio®7 Flex System, ViiA 7 System, Stratagene Mx3000/Mx3005P, Corbett Rotor Gene 3000, and others.Instruments requiring High ROX calibration: ABI Prism7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, etc.Note: High Rox and Low Rox are formulated as described in Use 2.Scope of applicationThis product is designed for absolute quantification of the concentration of Illumina platform second-generation sequencing libraries. The end of the library contains Illumin P5 and P7 chip binding sequences, the length of which does not exceed 1kb, and the concentration of which is not less than 0.002pM can be used to perform quantitative experiments with this product. The qPCR Primer Mix provided in the kit contains the following two primer sequences:Primer 1:5'-AAT GAT ACG GCG ACC ACC GA-3' Primer 2: 5'-CAA GCA GAA GAC GGC ATA CGA-3'The primer sequence can be used in advance to confirm whether the library can be amplified by that primer pair.UsageAmplification template preparationThe library samples to be detected were diluted with TE (10 mM Tris-Cl, pH 8.0, 1 mM EDTA), and the concentration after dilution was as close as possible to the range of 0.01-20 pM. 4°C on ice was set aside.qPCR reaction system preparationThe desired cryopreservation reagent is pre-melted completely and mixed by inverting several times before preparation, then centrifuged briefly and set aside.The base reaction system for 20 µl was as follows:Reagent20 µl Reaction system2×SYBR qPCR Master Mix10 µlqPCR Primer Mix 10.8 µlTemplate4 µlddH₂O5.2 µlDescription: High Rox model: add 1 µl High Rox per 50 µl of reaction system;Low Rox model: 1 µl High Rox per 500 µl of reaction system.Prepare a sufficient amount of reaction system mixture according to the need, mix well and add to the reaction wells in a volume of 16 µl per well, add the same volume of TE to the blank control, and then add the prepared standards and diluted samples to the corresponding reaction wells in a volume of 4 µl/well. It is recommended to use 20 µl reaction system, if you need to carry out a smaller system reaction, the system components can be reduced in equal proportion.qPCR reaction programThe annealing temperature should be 60-64°C as a reference for the setting range, and the annealing temperature can be increased when a non-specific reaction occurs.If the average length of the library is greater than 700bp, the annealing/extension time should be increased appropriately.data analysisStandard curve productionThe standard curve was plotted using Ct values in the valid range. The standard curve correlation coefficient R2 should not be less than 0.99 and the slope should lie between -3.1 and -3.6. If the standard curve parameters are not reasonable, it is recommended to repeat the experiment.DNA Standard NameDNA Standard ConcentrationDNA Standard 120 pMDNA Standard 22 pMDNA Standard 30.2 pMDNA Standard 40.02 pMDNA Standard 50.002 pMLibrary Concentration CalculationsThe difference in Ct between the three replicate wells of the experiment should be no more than 0.2, otherwise the invalid data should be deleted or the experiment should be repeated. Do not use the Ct outside the valid Ct range of the standard curve to calculate the concentration of the diluted libraries. Please refer to the data processing Excel of this product for the specific library concentration calculation method.matters needing attentionThese instructions should be read in detail before testing. It should be carried out by personnel with specialized experience or qualified by training.Mix gently by turning up and down, avoid foaming as much as possible, and centrifuge for a short time before use.Avoid repeated freezing and thawing of this product; repeated freezing and thawing may degrade product performance.When preparing reaction solutions, use new or non-contaminated tips and centrifuge tubes to prevent contamination as much as possible... Read More |