| Description | Hotstart HiTaq& Super M-MuLV One Step RT-qPCR Kit (with UDG) is widely recognized for its exceptional speed and quantitative accuracy. This product enables continuous Real-Time RT-PCR reactions within a single tube, simplifying operations. The enzyme system employs thermolabile UDG (Uracil-DNA Hotstart HiTaq& Super M-MuLV One Step RT-qPCR Kit (with UDG) is widely recognized for its exceptional speed and quantitative accuracy. This product enables continuous Real-Time RT-PCR reactions within a single tube, simplifying operations. The enzyme system employs thermolabile UDG (Uracil-DNA Glycosylase) in combination with dUTP-containing substrates, effectively preventing carryover contamination from previous PCR products. The thermolabile UDG is completely inactivated at 50°C, ensuring it does not interfere with the reverse transcription products of the current reaction. This kit utilizes a highly stable and efficient reverse transcriptase (Super M-MuLV Reverse Transcriptase) and a chemically modified hot-start DNA polymerase (Hotstart HiTaq DNA Polymerase). It delivers high amplification efficiency and specificity, enabling robust Real-Time One-Step RT-PCR. This significantly enhances detection sensitivity and eliminates the need for post-PCR electrophoresis, making it particularly suitable for the detection of trace amounts of RNA. Specifically designed for convenient and highly sensitive one-step RT-PCR, this kit features a unique enzyme formulation and specially optimized buffer system. These ensure efficient and accurate reverse transcription and PCR amplification without the need for reaction optimization. It generates excellent standard curves over a wide quantitative range, allowing precise quantitative detection of target genes with high reproducibility and reliability. Applications: Quantitative or qualitative detection of nucleic acids using RNA as template. Reverse transcription and amplification are completed in a single tube without tube opening.Product Component ListU1492590Component100T1000T10000TStorageU1492590AHotstart HiTaq& Super M-MuLV Mix0.2 mL2 mL20 mL-20℃U1492590BBuffer Mix0.95 mL9.5 mL95 mL-20℃ Protocol:1. Reaction Setup:Thaw and thoroughly mix all PCR solutions required for the reaction.Briefly centrifuge the solutions and keep them at room temperature until use.Probes should be protected from light.Recommendation: Aliquot PCR reagents to avoid repeated freeze-thaw cycles.2. Prepare the PCR Reaction Mixture according to the table below:ComponentVolume/25 µLVolume/50 µLFinal ConcentrationBuffer Mix9.5 µL19 µL1×Enzyme Mix (Hotstart HiTaq& Super M-MuLV)2 µL4 µL2/50 µLPrimer-Probe Mix1 µL2 µL/Template5 µL10 µL/ddH2OTo 25 µLTo 50 µL/Total Volume25 µL50 µLNote: The amounts of primers, probes, and template can be adjusted according to experimental requirements.3. Mixing:Gently mix the reaction components by pipetting up and down or by brief vortexing. Centrifuge briefly at room temperature to collect the liquid at the bottom of the tube.4. PCR Amplification:Place the PCR reaction tubes in the thermal cycler and initiate the PCR program.Standard Thermal Cycling Protocol:StepTemperatureTimeCyclesReverse Transcription50℃15min1Initial Denaturation95℃10min1Denaturation95℃10s45Annealing/Extension60℃40s45Hold12℃∞1Note: Reaction conditions can be adjusted based on specific experimental requirements... Read More | DescriptionUse in combination with the KitAlysis Bench Top Inertion Box (Z742064) or a glove box/glove bag to provide inert atmosphere for kit set-up.Designed to be used with KitAlysis High-Throughput Screening Kits.Components:24-Well Reaction BlockTorque ScrewdriverSmall screwdriver to easily DescriptionUse in combination with the KitAlysis Bench Top Inertion Box (Z742064) or a glove box/glove bag to provide inert atmosphere for kit set-up.Designed to be used with KitAlysis High-Throughput Screening Kits.Components:24-Well Reaction BlockTorque ScrewdriverSmall screwdriver to easily remove torqued screws after reaction is complete.10 Reaction Block Replacement Screws... Read More | Product introduction:Reporter gene detection is an important tool for analyzing the interaction between potential cis elements (such as promoters, enhancers and silencers) and trans acting factors in the flanking region of structural genes in the field of modern molecular biology. Firefly Product introduction:Reporter gene detection is an important tool for analyzing the interaction between potential cis elements (such as promoters, enhancers and silencers) and trans acting factors in the flanking region of structural genes in the field of modern molecular biology. Firefly luciferase is widely used in gene regulation and drug screening. Firefly luciferase is a protein with a molecular weight of about 61 KD. In the presence of ATP, magnesium ions and oxygen, it can catalyze the production of oxyluciferin from luciferin. In the process of luciferin oxidation, it will produce a light signal. The optical signal of this kit is a kind of instantaneous light, which needs to be detected immediately after adding the working solution. The half-life of optical signal is about 5 min.Instruction:1.Working fluid configuration ( 1 ) Restore all components to room temperature. ( 2 ) The component B ( stock solution ) was fully diluted with component A to prepare a 0.2 mg / mL firefly luciferase working solution, which was vortexed and shaken to ensure full mixing. Note : The firefly luciferase working solution cannot be repeatedly frozen and thawed. If the dosage of a single experiment is small, it is recommended to subpackage according to a single dosage. At room temperature, the activity decreased by about 10 % after the working solution was configured for 3 h, and the activity decreased by about 25 % after 5 h. 2.chemiluminescence value detection ( 1 ) The cell culture plate was taken out from the incubator and incubated at room temperature for 20 min to restore it to room temperature ( 22-25 ° C ). ( 2 ) Add the same volume of firefly luciferase working solution with the medium to the culture plate and mix well. ( 3 ) Incubation at room temperature for 5 min. Note : The incubation time can be adjusted according to cell type and cell number. ( 4 ) The values were read by multifunctional microplate reader or chemiluminescence instrument ( instrument parameters : the determination time was 10 s, the determination interval was 2 s ).Matters needing attention:1. please centrifuge the product to the bottom of the tube immediately before use, and then conduct subsequent experiments. 2. the strongest wavelength of bioluminescence catalyzed by firefly luciferase is 560 nm. 3. to prevent interference between holes, it is recommended to use white opaque orifice plate.Recommendation:Component B is recommended to use sterile water in advance to configure 2 mg / mL storage solution, A component and B component configured as storage solution, and small batch packaging according to the experimental requirements. The detection working fluid is recommended to be used now to avoid repeated freezing and thawing. Component:One-Step Firefly Luciferase Assay Buffer;D-Luciferin Scope of application:Mainly used for ADCC detection... Read More | R669988 Component 50T Storage R669988A DNase I 1000 U -20℃. Avoid freeze/thaw cycle. R669988B 10×Reaction Buffer 1000 µL -20℃. Avoid freeze/thaw cycle. R669988C Buffer RL 35 mL RT R669988D Buffer RLC 35 mL RT R669988E Buffer RW1 40 mL RT R669988F Buffer RW2 (concentrate) 11 mL R669988 Component 50T Storage R669988A DNase I 1000 U -20℃. Avoid freeze/thaw cycle. R669988B 10×Reaction Buffer 1000 µL -20℃. Avoid freeze/thaw cycle. R669988C Buffer RL 35 mL RT R669988D Buffer RLC 35 mL RT R669988E Buffer RW1 40 mL RT R669988F Buffer RW2 (concentrate) 11 mL RT R669988G RNase-Free Water 10 mL RT R669988H Spin Columns FL with Collection Tubes 50 sets RT R669988I Spin Columns RM with Collection Tubes 50 sets RT R669988J RNase-Free Centrifuge Tubes (1.5 mL) 50 EA RTProductsThis kit is used for the extraction and purification of high-quality total RNA from a variety of plants, and is also suitable for the extraction of fungal mycelial RNA. The unique separation column is used for homogenization and filtration of high viscosity plant or fungal lysates, while the silicon matrix membrane is used to adsorb the RNA for purification, so that various contaminants, such as polysaccharides, are effectively removed by washing, and the eluted RNA can be directly used in various downstream experiments. The molecular weight of RNA extracted by this kit is more than 200 bases, with high purity and almost no DNA residue. For RNA experiments that are very sensitive to trace DNA, the residual DNA can be removed by digestion on a column using RNase-free DNase. The extracted RNA can be used in Northern Blot, Dot Blot, RT-PCR and in vitro translation experiments.Self-contained reagents: β-mercaptoethanol, anhydrous ethanol (freshly opened or for RNA extraction).Pre-experiment Preparation and Important Notes1. To prevent RNase contamination, attention should be paid to the following aspects:1) Use RNase-free plastics and tips to avoid cross-contamination.2) RNase-free water should be used to prepare the solution.(3) Operators wear disposable masks and gloves, and change gloves diligently during the experiment.2. To prevent RNase contamination, attention should be paid to the following aspects:1) Use RNase-free plastics and tips to avoid cross-contamination.(2) Glassware should be dry-roasted at 180°C for 4 hours before use, and plasticware can be soaked in 0.5M NaOH for 10 minutes, rinsed thoroughly with water and autoclaved.3) RNase-free water should be used to prepare the solution.(4) Operators wear disposable masks and gloves, and change gloves diligently during the experiment.3. Avoid repeated freezing and thawing of the extracted samples, otherwise it will affect the amount and quality of RNA extraction.4. Please add β-mercaptoethanol to Buffer RL before use, add 10µl of β-mercaptoethanol to 1ml of Buffer RL, it can be stored for 1 month at room temperature. Buffer RL with β-mercaptoethanol can be stored at room temperature for 1 month. β-mercaptoethanol is not required for use of Buffer RLC.5. Anhydrous ethanol should be added to Buffer RW2 before first use according to the instructions on the reagent bottle label.6. If precipitation occurs in Buffer RL and Buffer RLC, heat to dissolve and leave at room temperature.7. All centrifugation steps are carried out at room temperature and all steps are performed quickly. Procedure1. 50-100 mg of plant tissue is quickly ground to a powder in liquid nitrogen and added to 600 µl of Buffer RL (check for addition of β-mercaptoethanol before use) or Buffer RLC. vortexing and oscillating to allow for adequate lysis.Note: 1) The main component of Buffer RL is guanidine isothiocyanate, which is suitable for lysis of most plant tissues. However, in some plant tissues (e.g. endosperm of corn), due to the special secondary metabolites, guanidine isothiocyanate causes precipitation of the sample, resulting in poor RNA extraction, in this case, Buffer RLC can be added instead of Buffer RL.2) Incubation at 56°C for 1-3 minutes helps tissue lysis, but do not incubate at high temperatures for plants with high starch content.2. Transfer all the liquid obtained in step 1 to an adsorption column (Spin Columns FL) that has been loaded into a collection tube, centrifuge at 12,000 rpm (~13,400 x g) for 2 minutes, and transfer the supernatant from the collection tube to a new centrifuge tube (supplied).Note: 1) The tip of the tip of the gun can be cut off when aspirating liquids to facilitate sampling.2) Spin Columns FL removes most of the debris, but a small portion will still flow out and a precipitate will form in the collection tube after centrifugation, so be careful to avoid aspirating the precipitate when proceeding to the next step.3. Add 0.5 times the volume of anhydrous ethanol to the clean lysate obtained in step 2 and mix rapidly.Note: Precipitation may occur upon addition of ethanol, but does not affect subsequent tests.4. Transfer the solution obtained in the previous step to the Spin Columns RM in the collection tube. If it is not possible to add all of the solution to the column at one time, centrifuge the column at 12,000 rpm for 15 seconds in two batches, discard the waste solution and put the column back into the collection tube.5. Add 350 µl Buffer RW1 to the adsorbent column, centrifuge at 12,000 rpm for 1 min, discard the waste liquid and put the adsorbent column back into the collection tube.6. Preparation of DNase I mixture: Take 52µl of RNase-Free Water, add 8µl of 10×Reaction Buffer and 20µl of DNase I (1U/µl) to it, mix well, and make a final volume of 80µl of reaction solution.7. Add 80µl of DNase I mixture directly to the adsorption column and incubate at 20-30°C for 15 minutes.8. Add 350 µl of Buffer RW1 to the adsorption column, centrifuge at 12,000 rpm for 1 minute, discard the waste liquid and put the column back into the collection tube.9. Add 500 µl of Buffer RW2 to the column (check that anhydrous ethanol is added before use), centrifuge at 12,000 rpm for 15 seconds, and discard the waste solution.10. Repeat step 9.11. Place the adsorbent column back into the collection tube, centrifuge at 12,000 rpm for 1 minute, and allow the column to come to room temperature for a few minutes to thoroughly dry out the anhydrous ethanol in the adsorbent column.Note: The purpose of this step is to remove residual ethanol from the adsorption column; ethanol residue can interfere with subsequent enzymatic reactions (zymography, PCR, etc.).12. Load the adsorption column into a new centrifuge tube, add 30-50 µl of RNase-Free Water to the middle of the adsorbent membrane, leave it at room temperature for 1 minute, centrifuge at 12,000 rpm for 1 minute, and store the resulting RNA solution at -70°C to prevent degradation.Note: 1) The volume of RNase-Free Water should not be less than 30 µl, too small volume affects the recovery rate.2) If you want to increase the RNA yield, repeat step 12 with 30-50 µl of fresh RNase-Free Water.3) If the RNA concentration is to be increased, the resulting solution can be reintroduced into the adsorption column and step 12 repeated... Read More | Product Content R669990Component50 TStorageR669990ADNase I1000 U-20℃. Avoid freeze/thaw cycle.R669990B10×Reaction Buffer1 mL-20℃. Avoid freeze/thaw cycle.R669990CBuffer RL35 mLRTR669990DBuffer RW135 mLRTR669990EBuffer RW2 (concentrate)11 mLRTR669990FRNase-Free Water10 Product Content R669990Component50 TStorageR669990ADNase I1000 U-20℃. Avoid freeze/thaw cycle.R669990B10×Reaction Buffer1 mL-20℃. Avoid freeze/thaw cycle.R669990CBuffer RL35 mLRTR669990DBuffer RW135 mLRTR669990EBuffer RW2 (concentrate)11 mLRTR669990FRNase-Free Water10 mLRTR669990GSpin Columns RM with Collection Tubes50 setsRTR669990HRNase-Free Centrifuge Tubes (1.5 mL)50 EART ProductsThis kit combines highly efficient guanidine isothiocyanate cleavage technology with silica matrix membrane purification for the efficient extraction of total RNA from animal cells and tissues, typically up to 30 mg of tissue or 1x107 cells as a starting sample. The kit also allows recovery of incompletely purified RNA, in vitro transcription and RNA from enzymatic reactions. high quality RNA with molecular weights greater than 200 bases can be extracted and purified using the kit with virtually no DNA residue. If RNA experiments that are very sensitive to trace DNA are to be performed, residual DNA can be removed by on-column digestion using RNase-free DNase. The extracted RNA can be used in downstream experiments such as RT-PCR, Nothern Blot and Dot Blot. Self-contained reagents: β-mercaptoethanol, anhydrous ethanol (freshly opened or for RNA extraction).Pre-experiment Preparation and Important Notes1. To prevent RNase contamination, attention should be paid to the following aspects:1) Use RNase-free plastics and tips to avoid cross-contamination.2) RNase-free water should be used to prepare the solution.(3) Operators wear disposable masks and gloves, and change gloves diligently during the experiment.2. Avoid repeated freezing and thawing of the extracted samples, otherwise it will affect the amount and quality of RNA extraction.3. Please add β-mercaptoethanol to Buffer RL before use, add 10µl of β-mercaptoethanol to 1ml of Buffer RL. Buffer RL with β-mercaptoethanol can be stored for 1 month at room temperature.4. Anhydrous ethanol should be added to Buffer RW2 before first use according to the instructions on the reagent bottle label.5. Buffer RL may be heated at 56°C to dissolve if precipitation occurs and then left at room temperature.All centrifugation steps are performed at room temperature and all maneuvers are performed quickly.Procedure1. Sample handling1a Tissue: Grind tissue in liquid nitrogen. Add 600 µl Buffer RL for every 20-30 mg of tissue (check for addition of β-mercaptoethanol before use), and 350 µl Buffer RL for tissue samples of less than 20 mg. Sample volume is not to exceed one-tenth of the Buffer RL volume.1b Cells in monolayer culture: Lysed or processed into cell suspension directly in culture flask, centrifuged to obtain cell precipitate, discarded the supernatant, added 600µl Buffer RL for every 6-10 cm2 of culture area, 350µl Buffer RL for less than 6cm2, and blown several times repeatedly to make the cells lysed sufficiently.1c Cell suspension: centrifuge at 12,000 rpm (~13,400 × g) for 1 min and discard the supernatant to obtain the cell precipitate. Add 600 µl Buffer RL for every 5×106-1×107 cells, and 350 µl Buffer RL for less than 5×106 cells, and blow several times repeatedly to fully lysate.Note: 1) Try to get rid of the cell culture medium, which may inhibit cell lysis affecting RNA yield.2) Try to keep the cells well suspended and well lysed, otherwise RNA yield is affected.2. After the sample is fully lysed, leave it at room temperature for 5 minutes to allow complete separation of the protein-nucleic acid complex.3. Centrifuge at 12,000 rpm for 2-5 min and remove the supernatant for the following operations.4. Add 1x volume (600µl or 350µl) of 70% ethanol (prepared without RNase water) to the solution obtained in step 3 and mix well.Note: The addition of ethanol may produce a precipitate that will not affect subsequent experiments.5. Add all of the solution obtained in the previous step to the Spin Columns RM in the collection tube. If you cannot add all of the solution to the column at once, transfer it in two passes, centrifuge at 12,000 rpm for 1 minute, and discard the waste solution. Place the column back into the collection tube.Note: The maximum loading capacity of the adsorption column is 100µg, do not overload as this will affect the yield and purity of the RNA.6. Add 350 µl Buffer RW1 to the adsorbent column, centrifuge at 12,000 rpm for 1 min, discard the waste liquid and put the adsorbent column back into the collection tube.7. Preparation of DNase I mixture: Take 52 µl of RNase-Free Water, add 8 µl of 10×Reaction Buffer and 20 µl of DNase I (1 U/µl) to it, mix well, and prepare a final volume of 80 µl of reaction solution.8. Add 80µl of DNase I mixture directly to the adsorption column and incubate at 20-30°C for 15 minutes.9. Add 200 µl Buffer RW1 to the adsorbent column, centrifuge at 12,000 rpm for 1 min, discard the waste liquid and put the adsorbent column back into the collection tube.10. Add 500µl Buffer RW2 to the column (check that anhydrous ethanol is added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the column back into the collection tube.11. Repeat step 10.12. Centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Leave the adsorption column at room temperature for a few minutes to thoroughly dry the anhydrous ethanol in the adsorption column.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can interfere with subsequent enzymatic reactions (digestion, PCR, etc.).13. Transfer the adsorbent column into a new centrifuge tube, add 30-50 µl of RNase-Free Water to the middle of the adsorbent membrane, leave it at room temperature for 1 min, centrifuge at 12,000 rpm for 1 min, collect the RNA solution, and store the RNA at -70°C to prevent degradation.Note: 1) The volume of RNase-Free Wate should not be less than 30 µl, too small volume affects the recovery rate.2) If you want to increase the RNA yield, repeat step 13 with 30-50 µl of fresh RNase-Free Water.3) If the RNA concentration is to be increased, the resulting solution can be reintroduced into the adsorption column and step 13 repeated... Read More |