| Description | This kit innovatively adopts a column-based purification method to rapidly, gently, and efficiently lyse animal tissues or cells for total protein extraction. It provides both denaturing and native lysis buffers, allowing users to select the appropriate option based on downstream application This kit innovatively adopts a column-based purification method to rapidly, gently, and efficiently lyse animal tissues or cells for total protein extraction. It provides both denaturing and native lysis buffers, allowing users to select the appropriate option based on downstream application requirements. The entire extraction process takes only 1–8 minutes. Thanks to the column purification technology, it can process sample-lysis buffer mixtures as small as 20 µL and up to 500 µL, yielding protein solutions with concentrations of 2–8 mg/mL while effectively preventing protein loss. The extracted proteins can be quantified using the BCA method (Cat. No.: R1491648/B665595). C1491689 Component50TStorageC1491689ADenaturing Lysis Buffer25 mL2-8℃C1491689BNative Lysis Buffer25 mL2-8℃C1491689CProtease Inhibitor Cocktail500 µL-20℃C1491689DPurification Columns50 unitsRT.C1491689ECollection Tubes50 unitsRT.C1491689FPlastic Grinding Pestles4 unitsRT.Key Features1.Simple and rapid operation: Denatured total proteins can be obtained in as little as 1 minute.2.No protein loss: Efficiently extracts DNA-binding proteins by disrupting DNA duplexes.3.Small sample volume, high yield: Processes mixtures as small as 20 µL, yielding protein concentrations of 2–8 mg/mL.4.Versatile applications: Includes two lysis buffers for extracting both denatured and native proteins.Protocol1、Extraction of Denatured Total Protein1.Pre-chill the purification column and collection tube on ice.2.Sample processing: Add protease inhibitor cocktail to the denaturing lysis buffer at a 1:100 ratio shortly before use.2.1 Adherent cells:Wash cells with pre-chilled 1× PBS and aspirate the supernatant.Add the volume of denaturing lysis buffer specified in the appendix table to cover the culture surface, and pipette to mix.2.2 Suspension cells:Collect cells by low-speed centrifugation.Wash with pre-chilled 1× PBS, vortex, and centrifuge at 3,000 rpm for 2–3 minutes.Resuspend the cell pellet in PBS equal to the pellet volume.Add the specified volume of denaturing lysis buffer and vortex to lyse.Note: Partial incomplete lysis does not affect protein extraction. If the lysate is too viscous, directly transfer it to the purification column.2.3 Tissue samples:Place 15–20 mg of tissue on the purification column.Grind 50–60 times with a plastic pestle.Add 200 µL denaturing lysis buffer and grind another 30–60 times.Adjust lysis buffer volume proportionally for larger or smaller samples.Note: Reusable plastic pestles should be thoroughly rinsed with distilled water and dried.3.Centrifugation:3.1 Adherent or suspension cells: Transfer the lysate to the pre-chilled purification column and centrifuge at 14,000–16,000 rpm for 30 seconds.3.2 Tissue samples: Incubate the column at room temperature for 1–2 minutes, then centrifuge at 14,000–16,000 rpm for 1–2 minutes.4.Immediately place the collection tube on ice and discard the purification column. Denatured total protein extraction is complete.2、Extraction of Native Total Protein1.Pre-chill the native lysis buffer, purification column, and collection tube on ice.2.Sample processing: Add protease inhibitor cocktail to the native lysis buffer at a 1:100 ratio shortly before use.2.1 Adherent cells:Wash cells with pre-chilled 1× PBS and aspirate the supernatant.Add the specified volume of native lysis buffer and incubate on ice for 3–5 minutes. Pipette to mix.2.2 Suspension cells:Collect, wash, and resuspend cells as described in section I.Add native lysis buffer, vortex for 15 seconds, incubate on ice for 3–5 minutes, and vortex again for 10 seconds.2.3 Tissue samples:Grind tissue as described in section I, using native lysis buffer.3.Centrifugation:3.1 Adherent or suspension cells: Centrifuge at 14,000–16,000 rpm for 30 seconds.3.2 Tissue samples: Incubate on ice for 5 minutes (open lid), then close the lid and centrifuge at 4°C and 14,000–16,000 rpm for 1–2 minutes.4.Immediately place the collection tube on ice and discard the purification column. Native total protein extraction is complete. Cell Count (×10⁶)Lysis Buffer Volume (µL)0.3200.550110022003500 Appendix: Cell Number vs. Lysis Buffer VolumePrecautionsHigh viscosity of the lysate is normal when using this kit.For safety, wear a lab coat and disposable gloves during operation.For research use only... Read More | When apoptosis occurs, some DNA endonucleases will be activated. These endonucleases will cut off genomic DNA between nucleosomes and produce 180 bp-200 BP DNA fragments, which appear as a specific ladder pattern in agarose gel electrophoresis. When double strand or single strand breaks occur in When apoptosis occurs, some DNA endonucleases will be activated. These endonucleases will cut off genomic DNA between nucleosomes and produce 180 bp-200 BP DNA fragments, which appear as a specific ladder pattern in agarose gel electrophoresis. When double strand or single strand breaks occur in genomic DNA, a large number of sticky 3'-oh ends will be generated, which can interact with YF under the catalysis of deoxyribonucleotide terminal transferase (TDT) ®/ CY dUTP binding can directly detect apoptotic cells by fluorescence microscopy or flow cytometry. This kind of method is called terminal deoxynucleotidyl transferase mediated nick end labeling (TUNEL). Because normal or proliferating cells have almost no DNA breaks, there is no 3'-oh formation and they can rarely be stained. TUNEL method can stain intact single apoptotic nuclei or apoptotic bodies in situ, can accurately reflect the typical biochemical and morphological characteristics of apoptosis, and can detect a very small number of apoptotic cells, so it is widely used in the study of apoptosis. This kit has a wide range of applications and can be used to detect apoptosis in frozen or paraffin sections, as well as cultured adherent cells or suspended cells. It can selectively detect apoptotic cells, but not necrotic cells or cells with DNA strand breaks caused by irradiation and drug treatment. This kit detects cell apoptosis with a short time-consuming, one-step staining reaction and can be detected after washing. Component: Instruction: Experimental materials (self provided)PBS buffer (1 x, pH~7.4). 0.2% Triton X -100 (PBS formulation). 0.1% Triton X -100 (PBS formulation, containing 5 mg/mLBSA)4% paraformaldehyde (prepared with PBS)Immunohistochemical penDewaxing solvent (paraffin section sample)Related reagents for paraffin section processingAnti fluorescence quenching and sealing agent. ddH2Oexperimental design. A. Positive control:Prepare positive control slides using DNaseI treatment. DNaseI can digest single or double stranded DNA and expose the 3 '- OH end, artificially causing cell apoptosis. One experiment per time is sufficient. (To verify if there are any issues with the experimental operation and reagent kit)B. Negative control:Use TUNEL Reaction Buffer without TdT Enzyme and replace TdT Enzyme with ddH2O. (Mainly to exclude non-specific staining caused by cell apoptosis, operational processes, and other reasons; and to adjust the exposure intensity of the shooting.)C. Experimental processing group.The experimental group operated normally according to the instructions.D. Experimental control group.The experimental group operated normally according to the instructions.Experimental steps1. Sample preparation:(1) For adherent cells or cell smearsa. Clean once with PBS.Note: If you are concerned that the cells on the cell smear may not adhere firmly, you can dry the sample to make the cells adhere more firmly.b. Fixation: Add an appropriate amount of 4% paraformaldehyde (prepared with PBS) and fix at 4 ℃ for 30 minutes. Clean twice with PBS.c. Translucency: Add an appropriate amount of 0.2% Triton X -100 (prepared with PBS) and let it penetrate at room temperature for 20 minutes. Clean twice with PBS.d. Step 2: TUNEL reaction.(2) For suspended cells or cell suspensionsa. Collect cells (3-5 x 106 cells), centrifuge at 1000 rpm for 5 minutes, and wash twice with PBS.b. Fixation: Add an appropriate amount of 4% paraformaldehyde (prepared with PBS) and resuspend the cells thoroughly. Fix at 4 ℃ for 30 minutes. Centrifuge at 2000 rpm for 5 minutes and clean twice with PBS.c. Translucency: Add an appropriate amount of 0.2% Triton X -100 (prepared with PBS) and let it penetrate at room temperature for 20 minutes. Centrifuge at 2000 rpm for 5 minutes and clean twice with PBS.d. Step 2: TUNEL reaction.(3) Paraffin tissue sectioninga. Dewaxing and hydration: Place the sliced samples sequentially in xylene I (10 min) → xylene II (10 min) → 100% ethanol I (5 min) → 100% ethanol II (5 min) → 95% ethanol (5 min) → 90% ethanol (5 min) → 80% ethanol (5 min) → 70% ethanol (5 min) → ddH2O rinse for 5 min, rinse twice.Note: Xylene is toxic and volatile. Please perform this operation in a fume hood.b. Use filter paper to dry the liquid around the sliced sample, and circle the sample contour with an immunohistochemical pen for downstream transparency and labeling.Note: If it is found that the contour circle of immunohistochemistry strokes is damaged in subsequent experimental operations, it needs to be redrawn in a timely manner.c. Transparency: Dilute 2 mg/mL of ProteinaseK solution with PBS in a ratio of 1:100 to a final concentration of 20 µ g/mL. Add 100 µ L dropwise to each sample to cover all sample areas. Incubate at 20-37 ℃ for 20 minutes.Note: Protein K can penetrate the cell membrane and nuclear membrane, allowing subsequent staining reagents to fully enter the nucleus for reaction and improve labeling efficiency. An excessively long incubation time increases the risk of tissue slices falling off the carrier film during subsequent washing steps, while a too short incubation time may result in insufficient permeability treatment and affect labeling efficiency. To obtain better results, the concentration, incubation time, and temperature of Protein K need to be optimized according to different types of tissue samples.d. Wash the slices twice with PBS, each time for 5 minutes. Use filter paper to remove excess liquid, and place the processed sample in a wet box to keep it moist.Note: Protein K must be washed thoroughly in this step, otherwise it will seriously interfere with subsequent labeling reactions.e. Step 2: TUNEL reaction.(4) Frozen tissue sectionsa. Fixation: Take out frozen sections and warm them back to room temperature. Add an appropriate amount of 4% paraformaldehyde (prepared with PBS) and fix at room temperature for 30 minutes. Wash twice with PBS for 10 minutes each time.Note: If you are concerned that formaldehyde cleaning may not be clean enough, it may affect the final dyeing effect. After formaldehyde fixation is completed, an appropriate amount of 2 mg/mL glycine can be added and washed for 10 minutes to neutralize the residual fixing solution, and then PBS cleaning can be carried out.b. Use filter paper to dry the liquid around the sliced sample, and circle the sample contour with an immunohistochemical pen for downstream transparency and labeling.Note: If it is found that the contour circle of immunohistochemistry strokes is damaged in subsequent experimental operations, it needs to be redrawn in a timely manner.c. Transparency: Dilute 2 mg/mL of ProteinaseK solution with PBS in a ratio of 1:100 to a final concentration of 20 µ g/mL. Add 100 µ L dropwise to each sample to cover all sample areas. Incubate at 20-37 ℃ for 20 minutes.Note: Protein K can penetrate the cell membrane and nuclear membrane, allowing subsequent staining reagents to fully enter the nucleus for reaction and improve labeling efficiency. An excessively long incubation time increases the risk of tissue slices falling off the carrier film during subsequent washing steps, while a too short incubation time may result in insufficient permeability treatment and affect labeling efficiency. To obtain better results, the concentration, incubation time, and temperature of Protein K need to be optimized according to different types of tissue samples.d. Wash the slices twice with PBS, each time for 5 minutes. Use filter paper to remove excess liquid, and place the processed sample in a wet box to keep it moist.Note: Protein K must be washed thoroughly in this step, otherwise it will seriously interfere with subsequent labeling reactions.e. Step 2: TUNEL reaction.(5) Positive treatment (only the positive control is subjected to this step, and other samples are directly subjected to the TUNEL reaction step)a. Dilute 10 x DNase I Buffer with ddH2O in a ratio of 1:10 to 1 x DNase I Buffer for later use.b. Drip 100 µ L of 1xDNase I Buffer onto the processed sample, covering all sample areas, and equilibrate at room temperature for 5 minutes.c. Dilute DNase I (2 U) with 1 x DNase I Buffer at a ratio of 1:100/ µ L) A working solution with a final concentration of 20 U/mL.d. Discard the buffer and add 100 µ Incubate DNase I working solution with a concentration of 20 U/mL at room temperature for 10 minutes.e. Discard DNase I working solution and clean twice with PBS.f. Step 2: TUNEL reaction.2. TUNEL reaction(1) Prepare TUNEL reaction solution (ready to use): / 1 sample 5 sample 10 sample TdT enzyme 1 µL 5 µL 10 µL YF®488/555/594/640 TUNEL Reaction Buffer 49 µL 245 µL 490 µL TUNEL Total volume of reaction solution 50 µL 250 µL 500 µL (2) For adherent cells, cell smears, or tissue sectionsa. Add 50 to each sample µ L TUNEL reaction solution, evenly cover the sample with the reaction solution. The appropriate time for dark incubation at 37 ℃ (recommended staining time for cells is 30 minutes to 1 hour, and tissue staining time is 2 hours).Note: 50 µ L TUNEL reaction solution is suitable for smear, slicing, or 96 well plates (other different well plates can adjust the volume of TUNEL reaction solution appropriately to cover cells). If the sample to be tested is a smear, slice, or in a 24 well plate, 12 well plate, or 6 well plate, anti evaporation film can be used, or self sealing bags or other appropriate materials can be used to cut circular plastic sheets slightly smaller than the holes. After adding TUNEL reaction solution dropwise, cover the sample to prevent the evaporation of TUNEL reaction solution and make the TUNEL reaction solution evenly cover the sample.b. Discard the TUNEL reaction solution, wash twice with PBS, and then wash three times with 0.1% Triton X -100 (PBS preparation, containing 5 mg/mL BSA) for 5 minutes each time. This way, free unreacted markers can be removed cleanly.c. (Optional) Add an appropriate concentration of 5 to each sample µ DAPI staining solution with a concentration of g/mL, incubated at room temperature in dark for 5 minutes. After staining, discard DAPI staining solution and wash twice with PBS for 5 minutes each time.d. (Optional) Slice sealing: Add 50 drops to each sample µ L anti fluorescence quenching sealing agent (anti fluorescence quenching sealing agent may not be suitable for certain dyes, it is recommended to conduct pre experimental testing for compatibility before the experiment), cover the cover glass, gently tap the cover glass with the blunt end of tweezers to remove bubbles and ensure complete sealing.e. Use filter paper to remove excess liquid and add 100 to the sample area µ Keep the sample moist with PBS and immediately observe under a fluorescence microscope.(3) For suspended cells or cell suspensionsa. Add 50 to each sample tube µ Gently resuspend cells in LTUNEL reaction solution and incubate at 37 ℃ in the dark for 30-1 hour. Gently resuspend cells with a micropipette every 15 minutes.b. Centrifuge at 2000 rpm for 5 minutes, discard TUNEL reaction solution, and wash twice with 0.1% Triton X -100 (PBS preparation, containing 5 mg/mLBSA) for 5 minutes each time. This way, free unreacted markers can be removed cleanly.c. Add 100 to each sample tube µ L concentration is 5 µ DAPI staining solution with a concentration of g/mL, incubated at room temperature in dark for 5 minutes.d. Join 400 µ L PBS resuspended cells and immediately detected with a flow cytometer or observed under a fluorescence microscope after smearing.Matters needing attention:1. please centrifuge the product to the bottom of the tube immediately before use, and then conduct subsequent experiments. 2. when the staining background is heavy or non-specific staining is obvious, the staining time can be appropriately reduced. 3. it is recommended to add negative control and positive control groups during the experiment. 4. please wear mask and gloves when using component A. if it contacts the skin, please wash it with plenty of water immediately. 5. fluorescent dyes have quenching problems. Please try to avoid light to slow down fluorescence quenching. 6. for your safety and health, please wear experimental clothes and disposable gloves. Product parameters:590/617nm; Scope of application:Late apoptosis detection, TUNEL Kit... Read More | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export | Product content:D665967Component200 TStorageD665967ABuffer PB120 mLRTD665967BBuffer PS60 mLRTD665967CBuffer PW (concentrate)25 mLRTD665967DBuffer EB30 mLRTD665967ESpin Columns DM with Collection Tubes200 EART Product Introduction: This reagent kit adopts a new silicon-based membrane technology and Product content:D665967Component200 TStorageD665967ABuffer PB120 mLRTD665967BBuffer PS60 mLRTD665967CBuffer PW (concentrate)25 mLRTD665967DBuffer EB30 mLRTD665967ESpin Columns DM with Collection Tubes200 EART Product Introduction: This reagent kit adopts a new silicon-based membrane technology and reagent formula. Through a rapid and simple three-step process of binding, washing, and elution, 100 bp-10 kb DNA fragments can be purified and recovered from PCR products or enzyme reaction solutions (enzyme cutting, linking, probe labeling, etc.). Each adsorption column can adsorb up to 10 kb of DNA fragments µ G DNA, while minimizing impurities such as primers, oligonucleotides, enzymes, etc. The purified and recovered DNA has high purity and concentration, good integrity, and high recovery rate, and can be directly used for molecular biology experiments such as sequencing, linking and transformation, labeling, and in vitro transcription.Self prepared reagent: anhydrous ethanol.Preparation and important precautions before the experiment:1. All components can be stably stored in a dry, room temperature (15-30 ℃) environment for 1 year, and can be stored at 2-8 ℃ for longer periods of time. When the solution is stored at low temperature, it should be left at room temperature for a period of time before use, and then restored to room temperature before use.2. This reagent kit can selectively recover all DNA fragments from the solution. If you need to selectively recover specific fragments while removing other fragments of different sizes, please choose our company's gel recovery reagent kit.3.Before the first use, anhydrous ethanol should be added to the Buffer PW according to the instructions on the reagent bottle label.4. Before use, please check if there is any crystallization or precipitation in the Buffer PB. If there is any crystallization or precipitation, you can take a water bath at 37 ℃ for a few minutes to restore clarity.5. The recovery efficiency is related to the initial amount of DNA and the elution volume. The smaller the initial amount, the smaller the elution volume, and the lower the recovery rate.6. All centrifugation steps can be performed at room temperature.Operation steps:1. Estimate the volume of DNA reaction solution, add 5 times the volume of Buffer PB, and mix thoroughly (without removing paraffin or mineral oil).Note: 1) If the DNA reaction system is 50 µ l (excluding paraffin oil volume), add 250 µ l Buffer PB.2) After adding Buffer PB, check the pH value of the solution. If the pH value is greater than 7.5, add 10-30 to it µ 3 M sodium acetate (pH 5.0) was used to adjust the pH value to 5-7.2. Column balance: Add 200 to the spin columns DM that have been loaded into the collection tube µ Centrifuge at 13000 rpm (~16200 × g) for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.3. Add the solution obtained in step 1 to the adsorption column that has been loaded into the collection tube, let it stand at room temperature for 1 minute, centrifuge at 13000 rpm for 30-60 seconds, discard the waste liquid in the collection tube, and place the adsorption column in the collection tube.Attention: The volume of the adsorption column is 750 µ l. If the sample volume is greater than 750 µ l, it can be added in batches.4. Add 500 µ l of Buffer PW to the adsorption column (please check if anhydrous ethanol has been added before use), centrifuge at 13000 rpm for 30-60 seconds, discard the waste liquid in the collection tube, and place the adsorption column in the recovery tube.Note: If purified DNA is used for salt sensitivity experiments (such as flat end ligation experiments or direct sequencing), it is recommended to add Buffer PW and let it stand for 2-5 minutes before centrifugation.5.13000 rpm for 1 minute and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.). To ensure that downstream experiments are not affected by residual ethanol, it is recommended to open the cover of the adsorption column and place it at room temperature for a few minutes to thoroughly dry the residual ethanol in the adsorbent material at the bottom.6. Place the adsorption column into a new centrifuge tube (provided by oneself), add 30-50 µ l Buffer EB to the middle position of the adsorption membrane by hanging droplets, and let it stand at room temperature for 1 minute. Centrifuge at 13000 rpm for 1 minute and collect DNA solution- Store DNA at 20 ℃.Attention:1) The pH value of the eluent has a significant impact on the elution efficiency. If water is used as the eluent, its pH value should be ensured to be between 7.0-8.5 (the pH value of water can be adjusted to this range using NaOH).2) To improve the recovery of DNA, the solution obtained by centrifugation can be added back to the adsorption column, left at room temperature for 2 minutes, and centrifuged at 13000 rpm for 1 minute.3) The elution volume should not be less than 30 µ l. A small volume will affect the recovery efficiency... Read More | Product introduction:Reporter gene detection is an important tool for analyzing the interaction between potential cis elements (such as promoters, enhancers and silencers) and trans acting factors in the flanking region of structural genes in the field of modern molecular biology. Firefly Product introduction:Reporter gene detection is an important tool for analyzing the interaction between potential cis elements (such as promoters, enhancers and silencers) and trans acting factors in the flanking region of structural genes in the field of modern molecular biology. Firefly luciferase is widely used in gene regulation and drug screening. Firefly luciferase is a protein with a molecular weight of about 61 KD. In the presence of ATP, magnesium ions and oxygen, it can catalyze the production of oxyluciferin from luciferin. In the process of luciferin oxidation, it will produce a light signal. The optical signal of this kit is a kind of instantaneous light, which needs to be detected immediately after adding the working solution. The half-life of optical signal is about 5 min.Instruction:1.Working fluid configuration ( 1 ) Restore all components to room temperature. ( 2 ) The component B ( stock solution ) was fully diluted with component A to prepare a 0.2 mg / mL firefly luciferase working solution, which was vortexed and shaken to ensure full mixing. Note : The firefly luciferase working solution cannot be repeatedly frozen and thawed. If the dosage of a single experiment is small, it is recommended to subpackage according to a single dosage. At room temperature, the activity decreased by about 10 % after the working solution was configured for 3 h, and the activity decreased by about 25 % after 5 h. 2.chemiluminescence value detection ( 1 ) The cell culture plate was taken out from the incubator and incubated at room temperature for 20 min to restore it to room temperature ( 22-25 ° C ). ( 2 ) Add the same volume of firefly luciferase working solution with the medium to the culture plate and mix well. ( 3 ) Incubation at room temperature for 5 min. Note : The incubation time can be adjusted according to cell type and cell number. ( 4 ) The values were read by multifunctional microplate reader or chemiluminescence instrument ( instrument parameters : the determination time was 10 s, the determination interval was 2 s ).Matters needing attention:1. please centrifuge the product to the bottom of the tube immediately before use, and then conduct subsequent experiments. 2. the strongest wavelength of bioluminescence catalyzed by firefly luciferase is 560 nm. 3. to prevent interference between holes, it is recommended to use white opaque orifice plate.Recommendation:Component B is recommended to use sterile water in advance to configure 2 mg / mL storage solution, A component and B component configured as storage solution, and small batch packaging according to the experimental requirements. The detection working fluid is recommended to be used now to avoid repeated freezing and thawing. Component:One-Step Firefly Luciferase Assay Buffer;D-Luciferin Scope of application:Mainly used for ADCC detection... Read More |