| Description | This kit innovatively adopts a column-based purification method to rapidly, gently, and efficiently lyse animal tissues or cells for total protein extraction. It provides both denaturing and native lysis buffers, allowing users to select the appropriate option based on downstream application This kit innovatively adopts a column-based purification method to rapidly, gently, and efficiently lyse animal tissues or cells for total protein extraction. It provides both denaturing and native lysis buffers, allowing users to select the appropriate option based on downstream application requirements. The entire extraction process takes only 1–8 minutes. Thanks to the column purification technology, it can process sample-lysis buffer mixtures as small as 20 µL and up to 500 µL, yielding protein solutions with concentrations of 2–8 mg/mL while effectively preventing protein loss. The extracted proteins can be quantified using the BCA method (Cat. No.: R1491648/B665595). C1491689 Component50TStorageC1491689ADenaturing Lysis Buffer25 mL2-8℃C1491689BNative Lysis Buffer25 mL2-8℃C1491689CProtease Inhibitor Cocktail500 µL-20℃C1491689DPurification Columns50 unitsRT.C1491689ECollection Tubes50 unitsRT.C1491689FPlastic Grinding Pestles4 unitsRT.Key Features1.Simple and rapid operation: Denatured total proteins can be obtained in as little as 1 minute.2.No protein loss: Efficiently extracts DNA-binding proteins by disrupting DNA duplexes.3.Small sample volume, high yield: Processes mixtures as small as 20 µL, yielding protein concentrations of 2–8 mg/mL.4.Versatile applications: Includes two lysis buffers for extracting both denatured and native proteins.Protocol1、Extraction of Denatured Total Protein1.Pre-chill the purification column and collection tube on ice.2.Sample processing: Add protease inhibitor cocktail to the denaturing lysis buffer at a 1:100 ratio shortly before use.2.1 Adherent cells:Wash cells with pre-chilled 1× PBS and aspirate the supernatant.Add the volume of denaturing lysis buffer specified in the appendix table to cover the culture surface, and pipette to mix.2.2 Suspension cells:Collect cells by low-speed centrifugation.Wash with pre-chilled 1× PBS, vortex, and centrifuge at 3,000 rpm for 2–3 minutes.Resuspend the cell pellet in PBS equal to the pellet volume.Add the specified volume of denaturing lysis buffer and vortex to lyse.Note: Partial incomplete lysis does not affect protein extraction. If the lysate is too viscous, directly transfer it to the purification column.2.3 Tissue samples:Place 15–20 mg of tissue on the purification column.Grind 50–60 times with a plastic pestle.Add 200 µL denaturing lysis buffer and grind another 30–60 times.Adjust lysis buffer volume proportionally for larger or smaller samples.Note: Reusable plastic pestles should be thoroughly rinsed with distilled water and dried.3.Centrifugation:3.1 Adherent or suspension cells: Transfer the lysate to the pre-chilled purification column and centrifuge at 14,000–16,000 rpm for 30 seconds.3.2 Tissue samples: Incubate the column at room temperature for 1–2 minutes, then centrifuge at 14,000–16,000 rpm for 1–2 minutes.4.Immediately place the collection tube on ice and discard the purification column. Denatured total protein extraction is complete.2、Extraction of Native Total Protein1.Pre-chill the native lysis buffer, purification column, and collection tube on ice.2.Sample processing: Add protease inhibitor cocktail to the native lysis buffer at a 1:100 ratio shortly before use.2.1 Adherent cells:Wash cells with pre-chilled 1× PBS and aspirate the supernatant.Add the specified volume of native lysis buffer and incubate on ice for 3–5 minutes. Pipette to mix.2.2 Suspension cells:Collect, wash, and resuspend cells as described in section I.Add native lysis buffer, vortex for 15 seconds, incubate on ice for 3–5 minutes, and vortex again for 10 seconds.2.3 Tissue samples:Grind tissue as described in section I, using native lysis buffer.3.Centrifugation:3.1 Adherent or suspension cells: Centrifuge at 14,000–16,000 rpm for 30 seconds.3.2 Tissue samples: Incubate on ice for 5 minutes (open lid), then close the lid and centrifuge at 4°C and 14,000–16,000 rpm for 1–2 minutes.4.Immediately place the collection tube on ice and discard the purification column. Native total protein extraction is complete. Cell Count (×10⁶)Lysis Buffer Volume (µL)0.3200.550110022003500 Appendix: Cell Number vs. Lysis Buffer VolumePrecautionsHigh viscosity of the lysate is normal when using this kit.For safety, wear a lab coat and disposable gloves during operation.For research use only... Read More | Products contentN665993Component240 TStorageN665993AIndex N501 Primers for Illumina240 µL-20℃. Avoid freeze/ Thaw cycle.N665993BIndex N925-N948 Primers for Illumina24×10 µL-20℃. Avoid freeze/ Thaw cycle. Products Introduction This kit is a companion kit to the transposase-Products contentN665993Component240 TStorageN665993AIndex N501 Primers for Illumina240 µL-20℃. Avoid freeze/ Thaw cycle.N665993BIndex N925-N948 Primers for Illumina24×10 µL-20℃. Avoid freeze/ Thaw cycle. Products Introduction This kit is a companion kit to the transposase-based Rapid DNA Library Construction Kit for Illumina platform library construction. Each kit contains one N5 primer and 24 N7 primers, which can be used to prepare 24 different single-ended Index libraries. All reagents provided in the kits have been subjected to stringent quality control and functional validation to maximize the stability and reproducibility of library construction. The libraries can be used for sequencing on Illumina platforms such as HiSeq X-10/4000/2500/2000 and MiSeq. Provide your own instruments, reagents and consumables1. Magnetic frame: DynaMagTM-2 is recommended.2. DNA purification and recovery kit: It is recommended to use Kangwei DNA purification and recovery kit by magnetic bead method.3. DNA building kit: It is recommended to use the Kangwei Century transposase method second-generation sequencing rapid DNA building kit.4. Anhydrous ethanol.5. Reaction tubes: It is recommended to use low adsorption PCR tubes with 1.5 ml centrifuge tubes;Tip: It is recommended to use a high quality filter tip to prevent contamination of kits and library samples. Pre-experiment Preparation and Important NotesPlease centrifuge briefly before opening the cap so that the liquid collects at the bottom of the tube to avoid cross-contamination between different primers. ProcedureFor the use of the CombiVision Second Generation Sequencing Multisample Primer Kit, please follow the CombiVision Second Generation Sequencing Rapid DNA Library Kit protocol.Index N501 Primer for IlluminaIndex N901-N996 Primer for Illumina... Read More | This plant protein extraction kit can extract soluble plant proteins from fresh, frozen, or dried plant tissues. Suitable for protein extraction from various plants and different parts of plants (such as roots, stems, leaves, flowers, seeds, etc.), with high extraction efficiency, high protein yieldThis plant protein extraction kit can extract soluble plant proteins from fresh, frozen, or dried plant tissues. Suitable for protein extraction from various plants and different parts of plants (such as roots, stems, leaves, flowers, seeds, etc.), with high extraction efficiency, high protein yield, high activity, and fast speed. The extracted protein can be directly subjected to protein electrophoresis analysis, immunoprecipitation, Western Blot, protein activity determination, and protein purification experiments. The concentration of the extracted protein can be determined using the BCA protein quantification kit. P665757Component100 TStorageP665757APlant Protein Extraction Reagent100 mLRTP665757BProtease Inhibitor Cocktail (100×)1 mL-20℃. Avoid freeze/thaw cycle. Precautions:1. This product contains 1mM EDTA.2. To prevent protein degradation, all operations should be carried out on ice as much as possible.3. After extracting protein using this product, the BCA method can be used for protein quantification.4. To achieve the best experimental results, please adjust the optimal usage amount according to the experiment.Operation steps:1. Please remove the required Plant Protein Extraction Agent for pre cooling before protein extraction.2. Weigh the weight of the experimental plant tissue. Add 5 ml of Plant Protein Extraction Agent to 1 g of tissue (add Protein Inhibitor Cocktail in a 1:99 ratio before protein extraction).Attention:1) Before homogenization, cut large pieces of plant tissue into small pieces and homogenize them with a mechanical homogenizer for 10 seconds, with an interval of 10 seconds. Repeat the process three times and select the appropriate homogenization method according to the different tissue samples.2) The amount of lysate used is adjusted according to different parts of the plant. If concentrated protein extracts are needed, the amount of Plant Protein Extraction Agent used can be appropriately reduced.3. After homogenization, incubate on ice for 20-30 minutes.4.4 ℃ 13400 × g, centrifuge for 20 minutes.5. Collect soluble proteins from the supernatant for further purification or downstream analysis... Read More | The commonly used method of eukarYOtic gene expression regulation research is the detection of reporter genes, and bioluminescence is the most commonly used and effective means of reporter gene detection. Luciferase can catalyze the conversion of the substrate luciferin and emit photons. This The commonly used method of eukarYOtic gene expression regulation research is the detection of reporter genes, and bioluminescence is the most commonly used and effective means of reporter gene detection. Luciferase can catalyze the conversion of the substrate luciferin and emit photons. This product provides a rapid, sensitive and stable detection method for the expression of Renilla luciferase reporter gene in mammalian cells. Product characteristic:1.Rapid : Cell lysis was completed within 10-15 min ;2.Convenience : The reagent is easy to prepare, and the sample detection steps are simple;Instruction:1. Cell lysis ( 1 ) Remove the culture medium and gently wash with PBS ( adherent cells can be directly performed this operation, suspension cells should be centrifuged to collect cells ). Add 1 × Lysis Buffer ( diluted component A with sterile water at 4 : 1 ) according to the following scheme, and then place the culture plate on a micro-oscillator at room temperature for 15 min to fully lyse the cells. Note : The pyrolysis products can be stored at room temperature for 6 h, and can be stored at − 70 °C for a long time ( the pyrolysis products cannot be repeatedly frozen and thawed ). ( 2 ) The pyrolysis products after full pyrolysis were centrifuged at 10000-15000 rpm for 3-5 min. After centrifugation, the supernatant was moved into a new EP tube for subsequent detection. 2. Preparation of working fluid ( 1 ) Restore all components to room temperature. ( 2 ) Dilute component C into renilla luciferase working solution with component B, and the dilution method is to add 1 µL C component to 49 µL B component. 3.chemiluminescence value detection ( 1 ) According to the operation instructions of the instrument, the instrument with chemiluminescence detection function was opened, such as multifunctional microplate reader. The parameters were set, the determination time was 10 s, and the determination interval was 2 s. ( 2 ) The cell lysis products were added to the measuring tube according to the volume of 20 ~ 100 µL ( keep the same amount of samples each time ). 1 × Lysis Buffer was blank control. ( 3 ) 100 µL renilla luciferase working solution was added to determine the RLU ( Relative light unit ) value ( Shaking mixing function is recommended for microplate reader ). Note : The renilla luciferase working solution cannot be stored for a long time. It is now ready for use and is used once. Component:RenillaLuciferase Lysis Buffer;RenillaLuciferase Assay Buffer;CoelenterazineMatters needing attention:Scope of application: Matters needing attention:1.Please instantaneously centrifuge the product to the bottom of the tube before use, and then carry out subsequent experiments ; 2.Due to the influence of temperature on the enzyme reaction, the sample and reagent should be measured after reaching room temperature. 3.The strongest wavelength of bioluminescence catalyzed by renilla luciferase is 480 nm, in order to prevent interference between holes, it is recommended to use white opaque orifice plate ;4. B component is recommended to carry out small batch packing according to the experimental requirements ; 5.It is recommended to use it now to avoid repeated freezing and thawing ; 6.For your safety and health, please wear experimental clothes and wear disposable gloves. Scope of application:Study on gene expression regulation and promoter... Read More | Inquire |