Assay Kits

Assay kits are used to carry out analyses in a broad scope of applications including the study of targets such as drugs, molecules, disease pathways, chemical elements or compounds, and organisms. They are a routine procedure in the modern pharmaceutical, medical and forensic world as well as research and university laboratories around the globe. Assay kits come with all the necessary reagents, instructions and protocols for fast and efficient processing, allowing for repeatable results.
CompanyIBL-AmericaIBL-AmericaIBL-AmericaIBL-AmericaIBL-America
ItemAngiotensin II RIA AssayANGPTL2 ELISA AssayGlargine ELISA AssayGlucagon RIA AssayProinsulin ELISA Assay
Citations
(3)
Catalog NumberRB320 US27745IV2-113ERB310 USIV2-102E
PriceSupplier PageSupplier PageSupplier PageSupplier PageSupplier Page
DescriptionRadioimmunoassay (RIA) for the determination of angiotensin II in plasma (EDTA). For research use only, not for use in diagnostic procedures.Solid phase sandwich ELISA for the determination of human ANGPTL2 in serum, EDTA-plasma and cell culture supernatant. For research use only, not for use in diagnostic procedures._x000D_Immunometric assay (ELISA) for the determination of insulin Glargine in physiological plasma samples. For research use only, not for use in diagnostic procedures.Radioimmunoassay (RIA) for the determination of glucagon in human plasma. FDA exempt, can be used for in-vitro diagnostics.Immunometric assay (ELISA) for the quantitative measurement of intact proinsulin in heparin or EDTA plasma. Measurements of proinsulin are used in the diagnosis and treatment of patients with type 2 diabetes. FDA exempt, can be used for in-vitro diagnostics.
Detection TargetGPIHBP1 AutoantibodyC4a Des ArgInfluenza Virus A IgG0 / 3 - 30 Arbitrary Unit (AU)/mLAdrenaline / Noradrenaline
Sample TypeSerum, EDTA-plasma, heparin plasma, and post-heparin EDTA-plasma.Blood PlasmaSerum, Blood PlasmaSerum and plasma.Blood Plasma, Urine
MethodRadio Immuno Assay (RIA)Enzyme-Linked Immunosorbent Assay (ELISA)Enzyme-Linked Immunosorbent Assay (ELISA)Radio Immuno Assay (RIA)Enzyme-Linked Immunosorbent Assay (ELISA)
Detection Range4.7 to 150.0 pmol/L0.05 to 3.5 ng/mL10 to 250 mU/L.4.7 to 150 pmol/L2 to 110.1 pmol/L
Sensitivity0.001 U/mLInquire98.55 % (95 % confidence interval: 92.19 % - 99.96 %)10 ng/mLAdrenaline (Urine): 0.9 ng/mL. Adrenaline (Plasma): 10 pg/mL. Noradrenaline (Urine): 1.7 ng/mL. Noradrenaline (Plasma): 36 pg/mL.
Assay Time18 hrs 15 mins (incubation)2 hrs (incubation)6 hrs, 15 mins (incubation)36 to 48 hrs (total)4 hrs (incubation)
Get QuoteSupplier PageSupplier PageSupplier PageSupplier PageSupplier Page

Articles