Ultra pure water is water nearly or completely devoid of contaminants. Ultrapure water systems are an important component for laboratories across markets including manufacturing and the semi-conductor industry. These ultra pure water systems remove chemical contaminants through de-ionization (DI) and reverse osmosis. An ultra pure water system eliminates bacteria with UV radiation. These laboratory water purification systems can achieve up to 18.2 MOhm-cm in resistivity (high resistivity indicating low levels of anionic contamination) and can reduce organic carbon to less than 50 ppb. An ultrapure water system is equipped with ultra filters to remove endotoxins, DNase and Rnase left over from bacteria destroyed by UV, resulting in extremely low total organic carbon (TOC). Additional carbon filters in these laboratory water purification systems reduces the need for pre-treatment, permitting tap water as a source.
Find, compare, and request a quote for ultrapure water systems across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.
|  |  |  |
| Company | Stakpure GmbH | Stakpure GmbH | Stakpure GmbH |
| Item | OmniaLabDS | OmniaPure xsbasic | OmniaTap xstouch |
| Price | | | |
| Description | The OmniaLabDS is a CLRW/CLSI-grade pure water system designed for feeding clinical analyzers, steam sterilizers, and washer-disinfectors. Available in 20, 40, and 60 l/h output models, it features a 100 L pressurized tank with quality recirculation, regenerative polishing cartridges, a 0.2 µm The OmniaLabDS is a CLRW/CLSI-grade pure water system designed for feeding clinical analyzers, steam sterilizers, and washer-disinfectors. Available in 20, 40, and 60 l/h output models, it features a 100 L pressurized tank with quality recirculation, regenerative polishing cartridges, a 0.2 µm sterile filter, UV disinfection, and an optional emergency supply. Complies with DIN EN 285 and EN ISO 15883 international water standards.... Read More | Compact, area-efficient ultrapure water (Type I) system with OptiFill basic OneHand dispenser. Delivers 18.2 MO·cm resistivity and TOC <10 ppb (standard) or <5 ppb (UV variant). Integrated leakage sensor, pressure reducer, and pre-treatment cartridge. Bench or wall mountable. Available as standard (Compact, area-efficient ultrapure water (Type I) system with OptiFill basic OneHand dispenser. Delivers 18.2 MO·cm resistivity and TOC <10 ppb (standard) or <5 ppb (UV variant). Integrated leakage sensor, pressure reducer, and pre-treatment cartridge. Bench or wall mountable. Available as standard (art. 18000004) and UV (art. 18000005) models. Typical applications: AAS, IC, ICP, buffers and media preparation (standard); ultra-trace analysis, ICP-MS, HPLC, TOC-analysis (UV).... Read More | The OmniaTap xstouch (Blueline series) is an intelligent compact water purification system with intuitive touchscreen operation that simultaneously produces Type I ultrapure water and Type II pure water from a single unit connected directly to tap water. It combines RO, ion exchange, UV, TOC The OmniaTap xstouch (Blueline series) is an intelligent compact water purification system with intuitive touchscreen operation that simultaneously produces Type I ultrapure water and Type II pure water from a single unit connected directly to tap water. It combines RO, ion exchange, UV, TOC monitoring, and optional ultrafiltration. Available in two models: OmniaTap xstouch 8 UV-TOC and OmniaTap xstouch 8 UV-TOC/UF.... Read More |
| Method | RO cartridge ? stainless steel regenerative polishing cartridge ? 0.2 µm sterile filter capsule ? UV disinfection; sterile overflow and sterile vent filter + CO2 absorber included; optional UV tank disinfection and emergency supply | Ion exchange with integrated pre-treatment cartridge; UV lamp (UV variant); recirculation function to prevent biofilm | Reverse osmosis (RO) + ion exchange + UV irradiation + TOC monitoring; UV-TOC/UF model additionally includes ultrafiltration (UF) for endotoxin, RNase, DNase, and protease removal |
| Output | 20 l/h (OmniaLabDS20), 40 l/h (OmniaLabDS40), 60 l/h (OmniaLabDS60) at 15°C | Up to 2 L/min | 8 L/h (Type II pure water at 15°C); up to 2 L/min dispensing (Type I ultrapure water) |
| Resistivity | 10 up to 1 MO·cm | 18.2 MO·cm at 25 °C | 18.2 MO·cm at 25°C (Type I ultrapure water); 10–15 MO·cm at 25°C (Type II pure water) |
| Dimensions | Tower: 511 x 1520 x 575 mm (W x H x D); Base cabinet (tank): 511 x 800 x 575 mm (W x H x D) | 240 x 530 x 435 mm (W x H x D) | Without tank (with OptiFill touch dispenser): 240 x 530 x 435 mm (W x H x D); With 7 L docking tank: 253 x 530 x 520 mm; Production unit without tank (under-table): 240 x 415 x 310 mm; OptiFill touch wall dispenser: 90 x 482 x 337 mm; OptiFill touch bench dispenser: 250 x 650 (750 with extension) x 380 mm |
| Total Organic Carbon (TOC) | < 2 ppm (feed water requirement) | <10 ppb (standard); <5 ppb (UV variant) | < 5 ppb (Type I ultrapure water, both models); real-time TOC monitoring included |