Deionized water, also referred to as DI water or grade 1, is water that has been purified of virtually of its mineral ions through the use of uniquely manufactured ion-exchange filters in accordance with ASTM D1193. In some cases, this method may be used in combination with reverse osmosis (RO) to raise the level of purity. There are different types of deionization processes which are determined primarily by the type of resin used – cation or anion. Deionized water systems play key roles in numerous forms of laboratory testing as well as in industries such as food processing, pharmaceuticals, and manufacturing. The type and scale of the system can vary significantly depending on the desired applications.
Find, compare, and request a quote for DI water systems across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.
|  |  |  |
| Company | ELGA LabWater | ELGA LabWater | ELGA LabWater |
| Item | MEDICA® PRO High-performance Water Purification System | MEDICA® EDI 150/100 High-performance Water Purification System | PURELAB® Pharma Compliance |
| Catalog Number | MP030REM1-115-US / MP060REM1-115-US / MP120REM1-115-US | MED150M1-115 / MED100M1-115 | VCLSDM1 / VCLSDM1-D1 / VCLSDM1-D2 / VCLSDM1-D3 |
| Price | | | |
| Description | The MEDICA Pro range are specifically engineered to deliver reagent-grade water that meets Clinical Laboratory Reagent Water (CLRW) standards, supporting the quality requirements of high-performance, high-volume single or multiple clinical diagnostic analyzers. The systems can deliver up to 4.0 l/The MEDICA Pro range are specifically engineered to deliver reagent-grade water that meets Clinical Laboratory Reagent Water (CLRW) standards, supporting the quality requirements of high-performance, high-volume single or multiple clinical diagnostic analyzers. The systems can deliver up to 4.0 l/min of CLSI CLRW water with up to 120 l/hr of productivity to meet analyzer requirements. The single system design incorporates all the water purification components plus a 75L storage reservoir to ensure a very quick and cost-effective installation.
Features:- Space-Saving Design: ‘all in one’ design allows easy under-bench installation and flexibility for future relocation as the laboratory grows
- Guaranteed Performance At All Times: self-monitoring software with built-in emergency by-pass allows uninterrupted operation 24 hr/day
- Guaranteed Bacterial Specification: onboard technology combined with easy system sanitization ensures a specification of <1 CFU/ml
... Read More | The MEDICA® range is specifically designed to meet the water quality needs of high-performance, high-volume single or multiple Clinical Diagnostic Analyzers. The MEDICA® EDI incorporates EDI's Pulse Technology using Electrodeionization (EDI). The systems can deliver up to 4.5 l/min of CLSI CLRW The MEDICA® range is specifically designed to meet the water quality needs of high-performance, high-volume single or multiple Clinical Diagnostic Analyzers. The MEDICA® EDI incorporates EDI's Pulse Technology using Electrodeionization (EDI). The systems can deliver up to 4.5 l/min of CLSI CLRW water with up to 150 l/hr of productivity to meet analyzer requirements. The single system design incorporates all the water purification components plus a 75L storage reservoir to ensure a very quick and cost-effective installation.
Features:- Space-Saving Design: ‘all in one’ design allows easy under-bench installation and flexibility for future relocation as the laboratory grows
- Economy: incorporates ‘Pulse Technology’ using Electrodeionization (EDI) to ensure predictable running costs
- Guaranteed Performance At All Times: self-monitoring software with built-in emergency by-pass allows uninterrupted operation 24 hr/day
- Guaranteed Bacterial Specification: onboard technology combined with easy system sanitization ensures a specification of <1 CFU/ml
... Read More | The PURELAB® Pharma Compliance delivers a lab water solution focused on building the perfect relationship between discovery, production, and traceability, resulting in an intuitive, efficient, and compliant purification system.
PURELAB® Pharma Compliance is packed with innovative featuresThe PURELAB® Pharma Compliance delivers a lab water solution focused on building the perfect relationship between discovery, production, and traceability, resulting in an intuitive, efficient, and compliant purification system.
PURELAB® Pharma Compliance is packed with innovative features optimized for QC laboratories. It offers all the necessary purification, software capabilities, qualification documentation, and online support services necessary for the validation required to meet Good Manufacturing Practice (GMP).
The ultrapure water system meets your laboratory’s needs, with minimal intervention, improved efficiencies, and a contemporary style to complement any modern laboratory.
The Pharma Compliance includes secure software providing the evidence to meet FDA and EU standards for digital record keeping. Purification processes fulfil United States Pharmacopeia standards 643 and 645. Qualification documents provided enable the unit to support labs subject to validation under GxP. - Highly competitive total cost of ownership
- Robust traceability
- Great ergonomics
A simply compliant, simply effective, and simply transparent solution. Daily usage: 120 l/day max. Delivery flow rate: up to 2.0 l/min.
Laptop not included... Read More |
| Output | Inquire | Up to 4 l/min @ 14psi (1bar) | Up to 2 L/min |
| Resistivity | Inquire | > 10 MΩ.cm | 18.2 MO.cm |
| Total Organic Carbon (TOC) | Inquire | < 30 ppb | 1 to 3 ppb |