Pipets and pipettors are used to transfer or measure set volumes of liquid, ranging from 0.1 µL to 10 mL. Start by choosing a displacement method: Air-displacement pipets are often recommended for aqueous samples since there is always an air cushion (dead volume) between the sample and the piston. Samples that are viscous, radioactive, corrosive, or volatile tend to require a positive-displacement pipet, which has a disposable piston and direct piston–sample contact. No air cushion means more accurate pipetting of high-density samples. Next, choose manual versus electronic operation. Manual pipettors tend to be very durable and easily maintained, while electronic pipettors have the advantage of increased accuracy, reduced force, and a lower risk of repetitive stress injuries. Repeating electronic pipets are useful in biochemistry, microbiology, and immunology. Single-channel pipets are workhorses in liquid handling; multichannel pipets are common in PCR and ELISA applications, with the number of channels ranging from 4 to 64.
Discover and compare Pipets and Pipettors:
|  |  |  |  |  |
| Company | Socorex Isba SA | Socorex Isba SA | Socorex Isba SA | Socorex Isba SA | Socorex Isba SA |
| Item | Stepper 416 Adjustable Repeater Pipette | Acura® dilute 810 dilution pipette | Acura® electro 956 Electronic Multichannel Pipettes | Acura® manual 826 XS Micropipettes | Acura® manual 835 Fixed Volume Micropipettes |
| Catalog Number | 416.5000 | 810.1100 | 956 Series | 826 series | 835F series |
| Price | | | | | |
| Description | Highly comfortable pipette intended for reliable dispensing and high performance results. Unique trigger action pipette eliminates thumb fatigue. Selected materials offer outstanding shock resistance and compact shape greatly limit internal contamination. Up to 73 doses within large selection of 53 Highly comfortable pipette intended for reliable dispensing and high performance results. Unique trigger action pipette eliminates thumb fatigue. Selected materials offer outstanding shock resistance and compact shape greatly limit internal contamination. Up to 73 doses within large selection of 53 different volumes.
Volumes range from 10 to 5000μL.
Features - Activation with 4-finger instead of thumb
- Setting knobs bear clear indication of
- Volumes and number of aliquots
- Only three positive displacement syringes,
- Colour coded
- Self-locking mechanism
- Two-year warranty
... Read More | 2 pre-calibrated fixed volume 1mL and 0,1 mL for dilution 1:10 in bacteriology and when using stomacher bags. Fully autoclavable. 3 year warranty. To be used with straw pipettes. | The electronic pipette includes a microprocessor-controlled motor and rechargeable battery pack. Four models with 8 and 12 channel cover the volume range 0.5 to 350 µL. Additional interchangeable volumetric modules available as accessories.
Acura® electro initial package includes electronic The electronic pipette includes a microprocessor-controlled motor and rechargeable battery pack. Four models with 8 and 12 channel cover the volume range 0.5 to 350 µL. Additional interchangeable volumetric modules available as accessories.
Acura® electro initial package includes electronic pipette. individual QC certificate and operating instructions. pipette charging stand. fast charger with AC adapter and cord. additional battery pack. Qualitips pipette tip samples.
Acura®electro pipette alone supplied with QC certificate and operating instructions. samples of Qualitips®.
Features - Large selection of 8- and 12-channel models
- Light weight and perfect hand fitting
- Sequential tip ejection
- Also fit any single channel volumetric module
... Read More | Derived from the Acura® manual 825 model, the manual pipettes 826 XS line was designed with the research scientists in mind. Shorter, smoother, lighter in weight, the eight models present key features aiming at excellence in pipetting.
Three-year warranty.
In addition to the 825 line, the Acura Derived from the Acura® manual 825 model, the manual pipettes 826 XS line was designed with the research scientists in mind. Shorter, smoother, lighter in weight, the eight models present key features aiming at excellence in pipetting.
Three-year warranty.
In addition to the 825 line, the Acura manual 826 XS micropipette offers:
- Excellent ergonomic shape and size ratio
- Soft springs and tightness seal for extra-smooth activation
- Reduced weight - lighter than leading brands
- Increased driveability with short, narrow shaft
- Conical shaft end for easy reach in smaller microtubes
TwiXS Pack Selection
Pipette packs offer an extended choice of volume combinations, covering all individual requirements in any research or routine application. Available at attractive saver prices, they match with today’s budget constraints.
Set includes:
- 2x Acura® manual 826 XS pipettes
- 1x Free shelf pipette holder
- 1x Qualitix® pipette tips samples
- 1x QC certificates / pipette
- 1x Operating instructions
... Read More | 4 Fixed volume macropipettes from 2 mL to 10 mL. Easy in-lab calibration. Fully autoclavable. 3 year warranty |
| Volume Range | 10 to 5000 uL | 1mL + 0.1 mL | 0.5 to 10 µL / 2.5 to 50 µL / 10 to 200 µL / 20 to 350 µL | 0.1 to 2 µL / 0.5 to 10 µL / 1 to 10 µL / 2 to 20 µL / 5 to 50 µL / 10 to 100 µL / 20 to 200 µL / 100 to 1000 µL | 0.2 to 10 mL (depending on model) |
| Type | Adjustable | 2 pre-calibrated fixed volume | Electronic, Rechargeable, Adjustable | Manual, Adjustable | Fixed volume |
| Get Quote | | | | | |