| Description | CO2 analyser with data memory for 5000 measuring points / Temperature, humidity / Export of the saved measurement data in CSV format / Battery and mains operation /
1/4 inch tripod mount / Measuring range (CO²) 0 ... 9999 ppm, (CO) 0 ... 1000 ppm
The CO2 analyser has a measuring range of 0 ... 9999CO2 analyser with data memory for 5000 measuring points / Temperature, humidity / Export of the saved measurement data in CSV format / Battery and mains operation /
1/4 inch tripod mount / Measuring range (CO²) 0 ... 9999 ppm, (CO) 0 ... 1000 ppm
The CO2 analyser has a measuring range of 0 ... 9999 ppm. In addition to the carbon dioxide measurement, the air quality detector also has a carbon monoxide (CO) sensor with a measuring range of 0 ... 1000 ppm and a temperature and humidity sensor. The air quality detector already covers a large range of measuring tasks. The air quality detector is therefore used, for example, in occupational safety to check the climatic conditions in office workplaces.... Read More | 3-Axis Vibration Meter / Vibration Tester for machines and systems / RS232C interface / AC output for headphones / 3-axis piezoelectric acceleration sensor / Incl. sensor tips
The 3-Axis Vibration Meter / Vibration Tester enables fast and precise measurement of acceleration, vibration displacement 3-Axis Vibration Meter / Vibration Tester for machines and systems / RS232C interface / AC output for headphones / 3-axis piezoelectric acceleration sensor / Incl. sensor tips
The 3-Axis Vibration Meter / Vibration Tester enables fast and precise measurement of acceleration, vibration displacement and vibration velocity in three directions (X, Y, Z) or for a single axis. It is used in accordance with ISO 2954 for the detection of unbalance, misalignment and mechanical faults in rotating machinery and is ideal for quality control, commissioning and predictive maintenance on site.
With a frequency range of 10 Hz to 10 kHz, it detects a wide range of vibrations, making it versatile for industrial applications. The 3-Axis Vibration Meter / Vibration Tester weighs just 163 g / 0.4 lbs and is easy to read even in difficult conditions thanks to the backlit 2-inch LCD display. In addition, the 3-Axis Vibration Meter / Vibration Tester switches off automatically after 30 minutes of inactivity to save energy.
The 3-Axis Vibration Meter / Vibration Tester has a 3-axis piezoelectric accelerometer with three mounting options: a magnetic sensor and two measuring tips (one conical and one spherical) that can be attached to the sensor. These accessories enable precise and versatile vibration measurements on various machines and surfaces. This makes the device a handy and powerful tool for industrial vibration measurements. It supports various units such as mm/s, inch/s, m/s², g, ft/s², mm and mil and has a measurement function that displays the maximum measured values.... Read More | Gas Detector / Gas Detection Instrument / Real-time measurement of HCHO, TVOC, temperature & humidity / Audible alarm / 2.8 inch colour display / Memory
The Gas Detector / Gas Detection Instrument is a versatile device for monitoring the air quality in indoor spaces such as homes, offices, Gas Detector / Gas Detection Instrument / Real-time measurement of HCHO, TVOC, temperature & humidity / Audible alarm / 2.8 inch colour display / Memory
The Gas Detector / Gas Detection Instrument is a versatile device for monitoring the air quality in indoor spaces such as homes, offices, workshops, schools or public facilities. It is used for the simultaneous measurement of formaldehyde (HCHO), volatile organic compounds (TVOC), ambient temperature and relative humidity. The Gas Detector / Gas Detection Instrument has a 2.8-inch color display that shows all measured values in real time and also visually assesses the air quality in three stages - green for "good", yellow for "poor" and red for "very poor". The Gas Detector / Gas Detection Instrument also has an acoustic alarm function with adjustable threshold values and sound types, which is triggered when defined measured values are exceeded.
For data storage, the device offers space for up to 200 measuring points on 5 pages, which corresponds to a total capacity of 1000 measurements per measured variable. The values for formaldehyde, TVOC and temperature are stored. The storage intervals and the number of collection points can be set individually, whereby the stored data can only be retrieved at any time via a playback function in the device. Other functions include a real-time clock, battery status display, adjustable measuring rate, automatic switch-off time, adjustable screen brightness and the option of active fan control. The temperature unit can be switched between Celsius and Fahrenheit.
The Gas Detector / Gas Detection Instrument is powered by an integrated 3.7V Li-Po battery and charged via a USB type C cable. The charge status is shown on the display during operation and charging. As a compact, precise and easy-to-use Gas Detector / Gas Detection Instrument, the Gas Detector / Gas Detection Instrument is ideal for continuously monitoring indoor air quality and helps to detect potential exposure to pollutants such as formaldehyde or organic vapors at an early stage and take appropriate countermeasures.... Read More | The illuminometer is used wherever a light check is necessary or recommended. The external light sensor of the illuminometer can be positioned according to requirements. The sensor cable has an extended length of approx. 1.5 metres. Different work or production projects require different lighting The illuminometer is used wherever a light check is necessary or recommended. The external light sensor of the illuminometer can be positioned according to requirements. The sensor cable has an extended length of approx. 1.5 metres. Different work or production projects require different lighting conditions.
Measuring ranges:
- 40 / 400 / 4000 / 40000 / 400000 lux
-
Measuring units: Lux or footcandles
-
Measuring accuracy: ± 3 %
-
Accuracy geared towards LED white light especially for LEDs
-
MIN- / MAX- / AVG-HOLD
-
2.5 measurements per second
-
Internal memory: 99 measured values
... Read More | The illuminometer has a large measuring range of 0 … 400 lux. The illuminance is measured using an external silicon photodiode with a spectral filter. This means that the illuminometer can be positioned appropriately for every measuring task.
- Measuring range: 0,0 … 400,000 Lux
-
Resolution: 0.1 lux
-
The illuminometer has a large measuring range of 0 … 400 lux. The illuminance is measured using an external silicon photodiode with a spectral filter. This means that the illuminometer can be positioned appropriately for every measuring task.
- Measuring range: 0,0 … 400,000 Lux
-
Resolution: 0.1 lux
-
Lux and footcandle units
-
Micro-USB interface
-
Incl. software
-
Rechargeable battery
-
Data memory: 32,000 sets of readings
... Read More |