| Description | The PCE-ATP 1-KIT with 100 swabs included is used to quickly and easily check the cleanliness of surfaces. The Hygiene Tester displays a measurement result on the large LC display after only 10 seconds. The Hygiene Tester's internal memory stores up to 10,000 measured data sets with time and date. The PCE-ATP 1-KIT with 100 swabs included is used to quickly and easily check the cleanliness of surfaces. The Hygiene Tester displays a measurement result on the large LC display after only 10 seconds. The Hygiene Tester's internal memory stores up to 10,000 measured data sets with time and date. The PCE-ATP 1 with the associated PCE-ATP SwapPens, allows a quick detection of food or microbiological residues on all surfaces in contact with the product as an effectiveness test of cleaning and disinfection measures. Quantitative determination of intracellular and extracellular adenosine triphosphate (ATP) is performed in the portable PCE-ATP 1. The measured data from the Hygiene Tester can be stored and further processed after the measurement. The Hygiene Tester is used in the hygiene control in pharmacy, medicine, gastronomy, wholesalers and more.... Read More | The CO2 content in the air is an important measure for checking the ventilation behavior in offices, classrooms, lecture halls, etc. The CO2 / carbon dioxide measuring device helps to ensure that, for example, there is regular ventilation for employees in the office. The CO2 / carbon dioxide The CO2 content in the air is an important measure for checking the ventilation behavior in offices, classrooms, lecture halls, etc. The CO2 / carbon dioxide measuring device helps to ensure that, for example, there is regular ventilation for employees in the office. The CO2 / carbon dioxide measuring device checks indoor air quality via the CO2 content. If the CO2 concentration is below 1000 ppm, the indoor air quality is optimal. Good indoor air quality helps to promote concentration. It is also ensured that the aerosol concentration in the air is low, as the aerosols are repeatedly mixed with fresh air. The CO2 / carbon dioxide measuring device shows the air quality as a numerical measured value and as a traffic light indicator. At the push of a button, the CO2 content of the last five hours can be shown on the display. In addition to the CO2 measuring function, the CO2 / carbon dioxide measuring device is equipped with a sensor for temperature and humidity.... Read More | Gas Detector / Gas Detection Instrument / Real-time measurement of HCHO, TVOC, temperature & humidity / Audible alarm / 2.8 inch colour display / Memory
The Gas Detector / Gas Detection Instrument is a versatile device for monitoring the air quality in indoor spaces such as homes, offices, Gas Detector / Gas Detection Instrument / Real-time measurement of HCHO, TVOC, temperature & humidity / Audible alarm / 2.8 inch colour display / Memory
The Gas Detector / Gas Detection Instrument is a versatile device for monitoring the air quality in indoor spaces such as homes, offices, workshops, schools or public facilities. It is used for the simultaneous measurement of formaldehyde (HCHO), volatile organic compounds (TVOC), ambient temperature and relative humidity. The Gas Detector / Gas Detection Instrument has a 2.8-inch color display that shows all measured values in real time and also visually assesses the air quality in three stages - green for "good", yellow for "poor" and red for "very poor". The Gas Detector / Gas Detection Instrument also has an acoustic alarm function with adjustable threshold values and sound types, which is triggered when defined measured values are exceeded.
For data storage, the device offers space for up to 200 measuring points on 5 pages, which corresponds to a total capacity of 1000 measurements per measured variable. The values for formaldehyde, TVOC and temperature are stored. The storage intervals and the number of collection points can be set individually, whereby the stored data can only be retrieved at any time via a playback function in the device. Other functions include a real-time clock, battery status display, adjustable measuring rate, automatic switch-off time, adjustable screen brightness and the option of active fan control. The temperature unit can be switched between Celsius and Fahrenheit.
The Gas Detector / Gas Detection Instrument is powered by an integrated 3.7V Li-Po battery and charged via a USB type C cable. The charge status is shown on the display during operation and charging. As a compact, precise and easy-to-use Gas Detector / Gas Detection Instrument, the Gas Detector / Gas Detection Instrument is ideal for continuously monitoring indoor air quality and helps to detect potential exposure to pollutants such as formaldehyde or organic vapors at an early stage and take appropriate countermeasures.... Read More | Laboratory Technology for liquids up to 5 l / Stirring speed up to 1600 rpm / Adjustable direction of rotation / Programme mode: up to 6 stirring programmes / 1 stirring position
The Laboratory Technology is an easy-to-use laboratory device that is used for the efficient mixing of liquids. With a 3Laboratory Technology for liquids up to 5 l / Stirring speed up to 1600 rpm / Adjustable direction of rotation / Programme mode: up to 6 stirring programmes / 1 stirring position
The Laboratory Technology is an easy-to-use laboratory device that is used for the efficient mixing of liquids. With a 3.7 inch LCD display and user-friendly controls, the stirring speed, stirring time and direction of rotation can be customized. The stirring speed can be set within a range of 100 ... 1,600 rpm and has an accuracy of ± 10 rpm.
Our Laboratory Technology automatically saves the last set working parameters and up to six individually programmed stirring cycles. This enables a quick restart with the desired settings. The stirrer also has an integrated timer that allows precise time control from one second to 99 hours and 59 minutes.
The use of a brushless motor ensures maintenance-free and quiet operation. The robust acrylic stirring plate measuring 173 × 180 mm provides a stable base for a wide range of stirring tasks, even for longer operating times. The Laboratory Technology can process liquid volumes up to a maximum of 5 litres and is operated via a power supply of AC 100 ... 240V at 50 Hz.
It is a good solution for laboratory work where reliable and reproducible mixing without heating is required. It impresses with its robust design and easy handling in research facilities and industrial laboratories.... Read More | Magnetometer / Magnetic Field Detector / Combined display / Memory for 10000 values / Wireless and USB-C interface / Incl. calibration standard
The Magnetometer / Magnetic Field Detector can be used to determine the relative magnetic permeability µr of materials and construction parts in the range Magnetometer / Magnetic Field Detector / Combined display / Memory for 10000 values / Wireless and USB-C interface / Incl. calibration standard
The Magnetometer / Magnetic Field Detector can be used to determine the relative magnetic permeability µr of materials and construction parts in the range between 1,000 and 5,000. Magnetic permeability, also known as magnetic conductivity, indicates how strongly a material can be magnetized. This Magnetometer / Magnetic Field Detector is ideal for material testing - especially for ferromagnetic material testing - in order to provide precise data for material testing NDT (non-destructive testing).
Areas of application include quality control of stainless steels, non-destructive material testing of construction parts, material selection for electron and ion physics equipment as well as for nuclear resonance devices, or the detection of material changes in highly stressed parts. The Magnetometer / Magnetic Field Detector has a graphic LCD touch panel with innovative user guidance and a resolution of 320 × 480 pixels.
The Magnetometer / Magnetic Field Detector supports all areas of permeability measurement with a flexible measured value memory, a combined digital and analogue display and peak value measurement. You can transfer the data to a Windows PC as well as to an Android or iOS app via the wireless interface. The Magnetometer / Magnetic Field Detector can be connected to an external power source in continuous operation via the USB interface.
You can check the accuracy of the measurement at any time using the calibration standard supplied with the permeability measuring device. The standard calibration standard has a value of µr ˜ 1.35. Calibration standards with reference values of µr ˜ 1.03 and µr ˜ 1.11 are also available.... Read More |