| Description | Portable 100 lpm aerosol hygiene monitoring device for airborne microbial, microbiological, bacterial, mold, fungi and virus analysis
PCE-AS1 is an air sampling meter used to assess microbiological pollution and monitor hygiene. Designed for use in hospitals, clean rooms and food and beverage, Portable 100 lpm aerosol hygiene monitoring device for airborne microbial, microbiological, bacterial, mold, fungi and virus analysis
PCE-AS1 is an air sampling meter used to assess microbiological pollution and monitor hygiene. Designed for use in hospitals, clean rooms and food and beverage, cosmetics and pharmaceutical production facilities, the PCE-AS1 air sampler meets the latest requirements for devices used for airborne microbial analysis. Optional ISO calibration lab certificate as an accessory.... Read More | The CO2 content in the air is an important measure for checking the ventilation behavior in offices, classrooms, lecture halls, etc. The CO2 / carbon dioxide measuring device helps to ensure that, for example, there is regular ventilation for employees in the office. The CO2 / carbon dioxide The CO2 content in the air is an important measure for checking the ventilation behavior in offices, classrooms, lecture halls, etc. The CO2 / carbon dioxide measuring device helps to ensure that, for example, there is regular ventilation for employees in the office. The CO2 / carbon dioxide measuring device checks indoor air quality via the CO2 content. If the CO2 concentration is below 1000 ppm, the indoor air quality is optimal. Good indoor air quality helps to promote concentration. It is also ensured that the aerosol concentration in the air is low, as the aerosols are repeatedly mixed with fresh air. The CO2 / carbon dioxide measuring device shows the air quality as a numerical measured value and as a traffic light indicator. At the push of a button, the CO2 content of the last five hours can be shown on the display. In addition to the CO2 measuring function, the CO2 / carbon dioxide measuring device is equipped with a sensor for temperature and humidity.... Read More | Geiger Counter / Measurement of beta, gamma and X-rays / Adjustable limit values / Progression diagram / Minimum, maximum and average values / Internal memory with PC transfer via software
The Geiger Counter is a portable device mainly used for monitoring X, ? and ß radiation. The Geiger Counter isGeiger Counter / Measurement of beta, gamma and X-rays / Adjustable limit values / Progression diagram / Minimum, maximum and average values / Internal memory with PC transfer via software
The Geiger Counter is a portable device mainly used for monitoring X, ? and ß radiation. The Geiger Counter is equipped with a glass Geiger-Müller counter tube (GM tube), which is known for its high measurement accuracy and sensitivity, and has a 2.4-inch TFT LCD display.
The Geiger Counter offers audible, visual and vibration alarms with customizable dose rate and total dose limits. It enables simultaneous real-time measurement of the dose rate and recording of the cumulative dose over a set period of time. In addition, the device displays the minimum, maximum and average values of the measurements.
The supplied software enables live measurement and data transfer from the internal memory. Thanks to its compact design, energy efficiency and versatility, the Geiger Counter is ideal for both professional and private use.... Read More | The illuminometer has a large measuring range of 0 … 400 lux. The illuminance is measured using an external silicon photodiode with a spectral filter. This means that the illuminometer can be positioned appropriately for every measuring task.
- Measuring range: 0,0 … 400,000 Lux
-
Resolution: 0.1 lux
-
The illuminometer has a large measuring range of 0 … 400 lux. The illuminance is measured using an external silicon photodiode with a spectral filter. This means that the illuminometer can be positioned appropriately for every measuring task.
- Measuring range: 0,0 … 400,000 Lux
-
Resolution: 0.1 lux
-
Lux and footcandle units
-
Micro-USB interface
-
Incl. software
-
Rechargeable battery
-
Data memory: 32,000 sets of readings
... Read More | Thickness Gauge with the unique swivelling probe / Easy measurements in hard-to-reach areas / For FE and nFE metals / Wireless interface for Windows, iOS and Android
The Thickness Gauge has a globally unique measuring probe that can be swiveled through 90°, allowing you to always carry out Thickness Gauge with the unique swivelling probe / Easy measurements in hard-to-reach areas / For FE and nFE metals / Wireless interface for Windows, iOS and Android
The Thickness Gauge has a globally unique measuring probe that can be swiveled through 90°, allowing you to always carry out precise coating thickness measurements. The Thickness Gauge with the compact, lightweight devices is barely larger than a measuring probe and is therefore ideal for on-site applications in hard-to-reach places. The handy metal housing is splash-proof to IP 64 for interference-free measurements in harsh environments. A coating thickness tester with flowing water protection is also available as an option. For a long service life with frequent measurements on rough surfaces, the measuring probe has a wear-resistant ruby probe pole.
With a single button and the self-explanatory, multilingual menu navigation, the Thickness Gauge is very easy to operate.
A Thickness Gauge is usually used in the quality assurance of coating processes. For example, to determine the paint thickness of a coating, when testing vehicles or steel structures or in fire protection (determining the coating thickness of steel doors). However, it is not only a Thickness Gauge, but can also be used to reliably measure rubber coatings, anodizing and galvanic coatings.
The Thickness Gauge uses a combined probe to measure insulating layers of paint, varnish, plastic, rubber, ceramic and galvanic coatings (excluding nickel) using the magnetic induction measuring method. The device is used on iron and steel substrates. It is also suitable for measuring insulating coatings (paint, plastic, etc.) using the eddy current method on non-ferrous metals such as aluminum, brass, copper, bronze and non-magnetic stainless steels in accordance with ISO 2178 and ISO 2360.
To further process your measurement data, you can connect your Thickness Gauge to mobile Android and iOS devices. Or you can communicate with a Windows PC. Wireless technology makes it possible. With the Lima Connect app, you can manage projects and allocate the measuring points on a photo. The measurement results can be statistically analysed and displayed graphically. The app for Android, iOS and Windows is free of charge.... Read More |