| Description | Portable 100 lpm aerosol hygiene monitoring device for airborne microbial, microbiological, bacterial, mold, fungi and virus analysis
PCE-AS1 is an air sampling meter used to assess microbiological pollution and monitor hygiene. Designed for use in hospitals, clean rooms and food and beverage, Portable 100 lpm aerosol hygiene monitoring device for airborne microbial, microbiological, bacterial, mold, fungi and virus analysis
PCE-AS1 is an air sampling meter used to assess microbiological pollution and monitor hygiene. Designed for use in hospitals, clean rooms and food and beverage, cosmetics and pharmaceutical production facilities, the PCE-AS1 air sampler meets the latest requirements for devices used for airborne microbial analysis. Optional ISO calibration lab certificate as an accessory.... Read More | The PCE-ATP 1-KIT with 100 swabs included is used to quickly and easily check the cleanliness of surfaces. The Hygiene Tester displays a measurement result on the large LC display after only 10 seconds. The Hygiene Tester's internal memory stores up to 10,000 measured data sets with time and date. The PCE-ATP 1-KIT with 100 swabs included is used to quickly and easily check the cleanliness of surfaces. The Hygiene Tester displays a measurement result on the large LC display after only 10 seconds. The Hygiene Tester's internal memory stores up to 10,000 measured data sets with time and date. The PCE-ATP 1 with the associated PCE-ATP SwapPens, allows a quick detection of food or microbiological residues on all surfaces in contact with the product as an effectiveness test of cleaning and disinfection measures. Quantitative determination of intracellular and extracellular adenosine triphosphate (ATP) is performed in the portable PCE-ATP 1. The measured data from the Hygiene Tester can be stored and further processed after the measurement. The Hygiene Tester is used in the hygiene control in pharmacy, medicine, gastronomy, wholesalers and more.... Read More | The CO2 content in the air is an important measure for checking the ventilation behavior in offices, classrooms, lecture halls, etc. The CO2 / carbon dioxide measuring device helps to ensure that, for example, there is regular ventilation for employees in the office. The CO2 / carbon dioxide The CO2 content in the air is an important measure for checking the ventilation behavior in offices, classrooms, lecture halls, etc. The CO2 / carbon dioxide measuring device helps to ensure that, for example, there is regular ventilation for employees in the office. The CO2 / carbon dioxide measuring device checks indoor air quality via the CO2 content. If the CO2 concentration is below 1000 ppm, the indoor air quality is optimal. Good indoor air quality helps to promote concentration. It is also ensured that the aerosol concentration in the air is low, as the aerosols are repeatedly mixed with fresh air. The CO2 / carbon dioxide measuring device shows the air quality as a numerical measured value and as a traffic light indicator. At the push of a button, the CO2 content of the last five hours can be shown on the display. In addition to the CO2 measuring function, the CO2 / carbon dioxide measuring device is equipped with a sensor for temperature and humidity.... Read More | Magnetometer / Magnetic Field Detector / Combined display / Memory for 10000 values / Wireless and USB-C interface / Incl. calibration standard
The Magnetometer / Magnetic Field Detector can be used to determine the relative magnetic permeability µr of materials and construction parts in the range Magnetometer / Magnetic Field Detector / Combined display / Memory for 10000 values / Wireless and USB-C interface / Incl. calibration standard
The Magnetometer / Magnetic Field Detector can be used to determine the relative magnetic permeability µr of materials and construction parts in the range between 1,000 and 5,000. Magnetic permeability, also known as magnetic conductivity, indicates how strongly a material can be magnetized. This Magnetometer / Magnetic Field Detector is ideal for material testing - especially for ferromagnetic material testing - in order to provide precise data for material testing NDT (non-destructive testing).
Areas of application include quality control of stainless steels, non-destructive material testing of construction parts, material selection for electron and ion physics equipment as well as for nuclear resonance devices, or the detection of material changes in highly stressed parts. The Magnetometer / Magnetic Field Detector has a graphic LCD touch panel with innovative user guidance and a resolution of 320 × 480 pixels.
The Magnetometer / Magnetic Field Detector supports all areas of permeability measurement with a flexible measured value memory, a combined digital and analogue display and peak value measurement. You can transfer the data to a Windows PC as well as to an Android or iOS app via the wireless interface. The Magnetometer / Magnetic Field Detector can be connected to an external power source in continuous operation via the USB interface.
You can check the accuracy of the measurement at any time using the calibration standard supplied with the permeability measuring device. The standard calibration standard has a value of µr ˜ 1.35. Calibration standards with reference values of µr ˜ 1.03 and µr ˜ 1.11 are also available.... Read More | Radiation Detector for indoor use / Long-term data storage / 2-inch LCD color display / Energy-saving mode / Real-time measurements
The compact Radiation Detector offers a precise and long-term stable solution for monitoring indoor radon concentrations. It is ideal for use in various environments Radiation Detector for indoor use / Long-term data storage / 2-inch LCD color display / Energy-saving mode / Real-time measurements
The compact Radiation Detector offers a precise and long-term stable solution for monitoring indoor radon concentrations. It is ideal for use in various environments such as living spaces, offices and laboratories. With a measuring range of 3.3 Bq/m³ ... 37 kBq/m³ and an accuracy of ± 15%, the Radiation Detector enables reliable measurement of the radon concentration. The integrated semiconductor radon sensor ensures high measurement accuracy. The measuring interval is 60 minutes and the data is saved every 6 hours, which enables long-term data storage of up to 504 days.
The Radiation Detector displays minimum, maximum and AVG values as well as cumulative average values and the values for 12, 24, 48 and 96 hours. It also offers an acoustic and visual alarm function, which can be set in the range from 100 ... 800 Bq/m³. The first measured values are displayed after 6 hours and a new data record is saved every 6 hours, whereby a maximum of 10 data records can be saved. The 2-inch LC colour display can be switched to standby mode to maximise the operating time of the Li-ion battery, which lasts up to 45 days when the display is switched off.
The Radiation Detector is used for continuous monitoring of indoor radon concentrations, for example in workplaces or public buildings. It is used for the early detection of increased radon levels in order to assess health risks and initiate suitable measures.... Read More |