| Description | The illuminometer is used wherever a light check is necessary or recommended. The external light sensor of the illuminometer can be positioned according to requirements. The sensor cable has an extended length of approx. 1.5 metres. Different work or production projects require different lighting The illuminometer is used wherever a light check is necessary or recommended. The external light sensor of the illuminometer can be positioned according to requirements. The sensor cable has an extended length of approx. 1.5 metres. Different work or production projects require different lighting conditions.
Measuring ranges:
- 40 / 400 / 4000 / 40000 / 400000 lux
-
Measuring units: Lux or footcandles
-
Measuring accuracy: ± 3 %
-
Accuracy geared towards LED white light especially for LEDs
-
MIN- / MAX- / AVG-HOLD
-
2.5 measurements per second
-
Internal memory: 99 measured values
... Read More | Portable handheld device for monitoring particulate matter (PM) concentrations in the air / 2.5 µm and 10 µm particle sizes / Measures air temperature and relative humidity. Designed to aid in indoor air quality (IAQ) assessments, this dust monitor also measures air temperature and relative humidityPortable handheld device for monitoring particulate matter (PM) concentrations in the air / 2.5 µm and 10 µm particle sizes / Measures air temperature and relative humidity. Designed to aid in indoor air quality (IAQ) assessments, this dust monitor also measures air temperature and relative humidity (RH). The dust monitor can be powered either by the built-in rechargeable battery or the USB port. The USB port also is used to charge the battery. At full charge, the battery provides up to 5 hours of continuous operation or unlimited operation when plugged into a USB power source. The dust monitor displays all measurements simultaneously on the device's 2.4" full-color LCD screen. PM values ??appear the largest in the colors green, yellow, gold, orange, pink and red. This visual color-coding system makes it easy to recognize when PM concentration levels become dangerous, allowing for quick action.... Read More | The CO2 content in the air is an important measure for checking the ventilation behavior in offices, classrooms, lecture halls, etc. The CO2 / carbon dioxide measuring device helps to ensure that, for example, there is regular ventilation for employees in the office. The CO2 / carbon dioxide The CO2 content in the air is an important measure for checking the ventilation behavior in offices, classrooms, lecture halls, etc. The CO2 / carbon dioxide measuring device helps to ensure that, for example, there is regular ventilation for employees in the office. The CO2 / carbon dioxide measuring device checks indoor air quality via the CO2 content. If the CO2 concentration is below 1000 ppm, the indoor air quality is optimal. Good indoor air quality helps to promote concentration. It is also ensured that the aerosol concentration in the air is low, as the aerosols are repeatedly mixed with fresh air. The CO2 / carbon dioxide measuring device shows the air quality as a numerical measured value and as a traffic light indicator. At the push of a button, the CO2 content of the last five hours can be shown on the display. In addition to the CO2 measuring function, the CO2 / carbon dioxide measuring device is equipped with a sensor for temperature and humidity.... Read More | Magnetometer / Magnetic Field Detector / Combined display / Memory for 10000 values / Wireless and USB-C interface / Incl. calibration standard
The Magnetometer / Magnetic Field Detector can be used to determine the relative magnetic permeability µr of materials and construction parts in the range Magnetometer / Magnetic Field Detector / Combined display / Memory for 10000 values / Wireless and USB-C interface / Incl. calibration standard
The Magnetometer / Magnetic Field Detector can be used to determine the relative magnetic permeability µr of materials and construction parts in the range between 1,000 and 5,000. Magnetic permeability, also known as magnetic conductivity, indicates how strongly a material can be magnetized. This Magnetometer / Magnetic Field Detector is ideal for material testing - especially for ferromagnetic material testing - in order to provide precise data for material testing NDT (non-destructive testing).
Areas of application include quality control of stainless steels, non-destructive material testing of construction parts, material selection for electron and ion physics equipment as well as for nuclear resonance devices, or the detection of material changes in highly stressed parts. The Magnetometer / Magnetic Field Detector has a graphic LCD touch panel with innovative user guidance and a resolution of 320 × 480 pixels.
The Magnetometer / Magnetic Field Detector supports all areas of permeability measurement with a flexible measured value memory, a combined digital and analogue display and peak value measurement. You can transfer the data to a Windows PC as well as to an Android or iOS app via the wireless interface. The Magnetometer / Magnetic Field Detector can be connected to an external power source in continuous operation via the USB interface.
You can check the accuracy of the measurement at any time using the calibration standard supplied with the permeability measuring device. The standard calibration standard has a value of µr ˜ 1.35. Calibration standards with reference values of µr ˜ 1.03 and µr ˜ 1.11 are also available.... Read More | Moisture Meter with one sensor / Measuring mode: fast, normal or continuous / Sample temperature / Practical case for mobile use
The portable Moisture Meter enables the precise determination of water activity (aw) in various products. It measures water activity in the range from 0 to 1.0000 aw and Moisture Meter with one sensor / Measuring mode: fast, normal or continuous / Sample temperature / Practical case for mobile use
The portable Moisture Meter enables the precise determination of water activity (aw) in various products. It measures water activity in the range from 0 to 1.0000 aw and temperatures from -10 to 50°C / 14 ... 122°F. The aw value indicates the proportion of free, unbound water in organic products such as foodstuffs or pharmaceuticals and is referred to as water activity. This value is crucial for assessing the shelf life and quality of products, as it influences the growth of microorganisms, molds and yeasts. In contrast to the total moisture content of a product, the Aw value is largely responsible for microbial stability.
The Moisture Meter delivers highly accurate results within just 3 to 5 minutes and works with precise sensors that ensure an accuracy of ± 0.015 aw in the temperature range of 10 to 30°C / 50 ... 86°F. It has three different measurement modes: normal mode, fast mode and continuous display mode. Calibration can be performed with one or more points (two, three or four points). The 2.8" TFT colour display ensures clear and intuitive operation, while the portable design and supplied instrument case allow flexible use in the field.
The device also offers extensive data management functions and can store up to 5,030 data records. The measurement results can be easily transferred to the software and output via the micro USB port. Power is supplied either via a 5V USB cable or four AA batteries, making it ideal for different environments and longer test times. Typical applications for the Moisture Meter include quality control in the food industry, pharmaceutical production processes, food and drug research institutes, the cosmetics industry, animal feed production, biological research centers, inspection and quarantine services and other laboratory analyses, for example in the tobacco and paper industries.
In addition to the sensor and the sample holder, the scope of delivery includes ten measuring beakers, the software, a USB cable, operating instructions and a practical carrying case. With the Moisture Meter, users receive a high-quality, portable measuring device for fast and precise determination of water activity, which is characterised by user-friendliness, versatile application options and maximum measuring accuracy.... Read More |