| Description | The illuminometer is used wherever a light check is necessary or recommended. The external light sensor of the illuminometer can be positioned according to requirements. The sensor cable has an extended length of approx. 1.5 metres. Different work or production projects require different lighting The illuminometer is used wherever a light check is necessary or recommended. The external light sensor of the illuminometer can be positioned according to requirements. The sensor cable has an extended length of approx. 1.5 metres. Different work or production projects require different lighting conditions.
Measuring ranges:
- 40 / 400 / 4000 / 40000 / 400000 lux
-
Measuring units: Lux or footcandles
-
Measuring accuracy: ± 3 %
-
Accuracy geared towards LED white light especially for LEDs
-
MIN- / MAX- / AVG-HOLD
-
2.5 measurements per second
-
Internal memory: 99 measured values
... Read More | The PCE-ATP 1-KIT with 100 swabs included is used to quickly and easily check the cleanliness of surfaces. The Hygiene Tester displays a measurement result on the large LC display after only 10 seconds. The Hygiene Tester's internal memory stores up to 10,000 measured data sets with time and date. The PCE-ATP 1-KIT with 100 swabs included is used to quickly and easily check the cleanliness of surfaces. The Hygiene Tester displays a measurement result on the large LC display after only 10 seconds. The Hygiene Tester's internal memory stores up to 10,000 measured data sets with time and date. The PCE-ATP 1 with the associated PCE-ATP SwapPens, allows a quick detection of food or microbiological residues on all surfaces in contact with the product as an effectiveness test of cleaning and disinfection measures. Quantitative determination of intracellular and extracellular adenosine triphosphate (ATP) is performed in the portable PCE-ATP 1. The measured data from the Hygiene Tester can be stored and further processed after the measurement. The Hygiene Tester is used in the hygiene control in pharmacy, medicine, gastronomy, wholesalers and more.... Read More | CO2 analyser with data memory for 5000 measuring points / Temperature, humidity / Export of the saved measurement data in CSV format / Battery and mains operation /
1/4 inch tripod mount / Measuring range (CO²) 0 ... 9999 ppm, (CO) 0 ... 1000 ppm
The CO2 analyser has a measuring range of 0 ... 9999CO2 analyser with data memory for 5000 measuring points / Temperature, humidity / Export of the saved measurement data in CSV format / Battery and mains operation /
1/4 inch tripod mount / Measuring range (CO²) 0 ... 9999 ppm, (CO) 0 ... 1000 ppm
The CO2 analyser has a measuring range of 0 ... 9999 ppm. In addition to the carbon dioxide measurement, the air quality detector also has a carbon monoxide (CO) sensor with a measuring range of 0 ... 1000 ppm and a temperature and humidity sensor. The air quality detector already covers a large range of measuring tasks. The air quality detector is therefore used, for example, in occupational safety to check the climatic conditions in office workplaces.... Read More | Laboratory for liquids up to 5 litres / Stirring speed up to 1600 rpm / 1 stirring position / Stirring plate - acrylic glass / Compact
The Laboratory is a compact and powerful laboratory device for the efficient mixing of liquids. With an adjustable stirring speed of 200 to 1600 rpm, it is ideal Laboratory for liquids up to 5 litres / Stirring speed up to 1600 rpm / 1 stirring position / Stirring plate - acrylic glass / Compact
The Laboratory is a compact and powerful laboratory device for the efficient mixing of liquids. With an adjustable stirring speed of 200 to 1600 rpm, it is ideal for volumes of up to 5 liters. The robust stirring plate made of acrylic glass with dimensions of 173 × 180 mm provides a stable work surface.
The Laboratory is driven by a brushless motor, which guarantees particularly quiet and low-maintenance operation. The stirring rod supplied measures 8 mm in diameter and is 30 mm long - ideal for a wide range of everyday laboratory applications. With a power consumption of just 10 watts, the Laboratory is also extremely energy-efficient. Power is supplied flexibly via 100 to 240V AC at 50/60 Hz.
Typical areas of application are chemical and biological laboratories, research facilities and industrial processes where reliable and uniform mixing is required.... Read More | Portable 100 lpm aerosol hygiene monitoring device for airborne microbial, microbiological, bacterial, mold, fungi and virus analysis
PCE-AS1 is an air sampling meter used to assess microbiological pollution and monitor hygiene. Designed for use in hospitals, clean rooms and food and beverage, Portable 100 lpm aerosol hygiene monitoring device for airborne microbial, microbiological, bacterial, mold, fungi and virus analysis
PCE-AS1 is an air sampling meter used to assess microbiological pollution and monitor hygiene. Designed for use in hospitals, clean rooms and food and beverage, cosmetics and pharmaceutical production facilities, the PCE-AS1 air sampler meets the latest requirements for devices used for airborne microbial analysis. Optional ISO calibration lab certificate as an accessory.... Read More |