| Description | Replacement soldering tips for the PCE-ESI 100 (set of 3)
Chisel tip (flat, bevelled – for larger solder joints) Tapered tip / pointed tip (tapering to a point – for precision work) Flat tip (wider, straight-cut) | Our robust socket square inserts are specially designed for use with impact wrenches and are ideal for demanding bolting applications. The range covers thread sizes from M16 to M48 and offers the right wrench sizes for a wide variety of applications.
These high-quality socket square inserts impress Our robust socket square inserts are specially designed for use with impact wrenches and are ideal for demanding bolting applications. The range covers thread sizes from M16 to M48 and offers the right wrench sizes for a wide variety of applications.
These high-quality socket square inserts impress with their high load-bearing capacity, precise fit, and long service life – perfect for professional use in industry and assembly.... Read More | The Health & Safety is ideal for precisely determining the electrical resistance of materials and surfaces in electronics manufacturing, ESD protection, laboratories and quality control. It is used to reliably determine whether a material is conductive, static dissipative or insulating, thus making The Health & Safety is ideal for precisely determining the electrical resistance of materials and surfaces in electronics manufacturing, ESD protection, laboratories and quality control. It is used to reliably determine whether a material is conductive, static dissipative or insulating, thus making a decisive contribution to the prevention of electrostatic discharge. Thanks to its compact design and ease of use, the device is ideal for both mobile use and stationary measurements and also serves as an ESD measuring device and electrostatic measuring device. Our measuring device covers a wide measuring range from 10³ ? to 10¹? ? and offers a measuring accuracy of 1 decade. The maximum display value is 20 G?; values above this indicate that the measuring range has been exceeded. The temperature measuring range is 0 ... 50°C / 32 °F ... 122°F with a deviation of ±2°C / ±3.6°F. An automatic switch-off after approximately five minutes ensures energy-saving operation, while the integrated backlight and data hold function allow for convenient reading of the measured values.
This Health & Safety has an easy-to-read 2.2-inch LCD display showing temperature, resistance, battery status and measurement mode. Three easy-to-use buttons control all functions, such as power on/off, temperature unit switching and data hold. Power is supplied by a 9 V block battery, allowing the Health & Safety to be operated independently of the mains. The Health & Safety also allows measurements to be taken on irregularly shaped objects and provides a clear evaluation of the measurement results: Values from 10³ to 10? ? indicate conductive materials, 10? to 10¹¹ ? indicate static dissipative properties, and from 10¹² ? onwards, surfaces are considered insulating. The device thus provides a quick and precise assessment of electrostatic properties and ensures greater safety and quality in sensitive production environments.
This measuring device is ideal for specialists in electronics manufacturing, ESD officers, technicians, engineers, testing laboratories and anyone who needs to check surfaces for electrical conductivity. As an ESD measuring device and electrostatic measuring device, it also provides reliable support in complying with electrostatic protection measures.... Read More | The illuminometer is used wherever a light check is necessary or recommended. The external light sensor of the illuminometer can be positioned according to requirements. The sensor cable has an extended length of approx. 1.5 metres. Different work or production projects require different lighting The illuminometer is used wherever a light check is necessary or recommended. The external light sensor of the illuminometer can be positioned according to requirements. The sensor cable has an extended length of approx. 1.5 metres. Different work or production projects require different lighting conditions.
Measuring ranges:
- 40 / 400 / 4000 / 40000 / 400000 lux
-
Measuring units: Lux or footcandles
-
Measuring accuracy: ± 3 %
-
Accuracy geared towards LED white light especially for LEDs
-
MIN- / MAX- / AVG-HOLD
-
2.5 measurements per second
-
Internal memory: 99 measured values
... Read More | The Light Sensor is ideal for monitoring light intensities in greenhouses, industrial facilities or smart farming systems, enabling precise control of lighting and energy use. The Light Sensor detects light intensities from 0 to 65,535 lx and delivers the measured values via a digital RS-485 Modbus The Light Sensor is ideal for monitoring light intensities in greenhouses, industrial facilities or smart farming systems, enabling precise control of lighting and energy use. The Light Sensor detects light intensities from 0 to 65,535 lx and delivers the measured values via a digital RS-485 Modbus RTU output. The accuracy is ±7% FS at 25°C / 77°F, the response time is ?1 s, the supply voltage is 10 to 30V DC, and the robust, moisture-protected housing allows for indoor and outdoor use.
The Light Sensor is primarily used by greenhouse operators, environmental researchers, and companies in the smart farming sector, as well as industrial plants that want to reliably monitor light intensities and implement automated controls.... Read More |